Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Surgical Instruments”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Innovations in eye surgery.

The field of ophthalmology has undergone revolutionary changes during the past few decades. Advancements in understanding the pathophysiology of eye diseases, superior surgical instrumentation and surgeon skills, and cotreatment with medical therapies have enhanced outcomes. The geriatric population, preferentially affected by these illnesses, has seen a meaningful visual benefit from these surgical innovations. Most importantly, these improvements have led to increases in quality-of-life measures and mental and physical well-being of aging patients.

Aged↗

Mechanical peritoneal retraction as a replacement for carbon dioxide pneumoperitoneum.

A fan retractor and a mechanical lifting arm were developed to achieve planar displacement of the anterior abdominal wall for gasless laparoscopic procedures. The technique permits the use of conventional open surgical instruments as well as laparoscopic tools through minilaparotomy incisions. It also potentially addresses the technical constraints imposed by pneumoperitoneum, and physiologic concerns regarding carbon dioxide insufflation. Gynecologic, general surgical, and trauma procedures were performed in 104 patients, with successful completion of 86.5%. Continued application is necessary to delineate the full range of benefits of laparoscopy without insufflation.

Equipment Design↗

Endoscopic endonasal transsphenoidal surgery.

The endoscopic endonasal transsphenoidal approach is a minimally invasive surgical technique for the removal of sellar and parasellar lesions. The procedure is performed via an anterior sphenoidotomy. The two main characteristics of the endoscopic approach, when compared with the standard microsurgical operation, arise from the use of the endoscope as a unique optical device and from the absence of a transsphenoidal retractor. More convenient straight surgical instruments are employed, whereas bayonet-shaped tools are used in the microsurgical procedure, to avoid any interference with the light beam generated by the microscope. The standard surgical technique is composed of three main time phases: the nasal, sphenoid, and sellar phase. During the nasal phase, the scope is introduced through the chosen nostril and advanced up to the sphenoethmoid recess, where the sphenoidotomy is performed. The sphenoid phase consists of the detachment of the nasal septum from the sphenoid rostrum, the anterior sphenoidotomy, removal of the sphenoid septum or septa, and identification of the landmarks inside the sphenoid sinus. In the sellar phase, an opening of the sellar floor is performed for removal of the lesion. A wide view of the sellar environment is obtained through angled scopes to detect eventual tumor remnants. The procedure ends with the reconstruction of the sella and removal of the endoscope from the nostril, without any postoperative nasal packing.

Adenoma↗

Nonendoscopic placement and use of percutaneous gastrostomy tubes in pigs (Sus scrofa domestica).

Swine have supplanted dogs and other large animal species in many biomedical applications and have become the model of choice for numerous areas of research. Anatomic, behavioral, and handling concerns often require pigs to be surgically instrumented for many procedures. Oral dosing in pigs can be accomplished by feeding substances in a palatable substrate, temporarily placing an oral or nasal gastric tube, or permanent surgical placement of an esophagostomy or gastrostomy tube. Oral and nasal gastric tube placement is difficult in conscious, unrestrained animals and is suitable only for short-term enteral access. Placing esophagostomy and gastrostomy tubes is suitable for long-term enteral access and allows easy and rapid administration of substances directly into the stomach. However, these methods frequently require major surgical manipulation for placement. Nonendoscopic percutaneous gastrostomy tube placement is used in companion animals to establish permanent or temporary enteral access. We successfully have adapted this procedure in swine as a method for short-term enteral access. This technique has several advantages over the traditional surgical method for gastrostomy tube placement. It is minimally invasive, results in less animal pain and distress, requires less procedural and recovery time, and is inexpensive. Disadvantages include the potential for splenic entrapment, splenic penetration, perforation of the esophagus, and other complications related to misplacement of the tube or applicator. This paper describes the equipment, technique, and potential complications for placing a nonendoscopic percutaneous gastrostomy tube in swine.

Animal Welfare↗

[Twist-guided thread control: a technique for faster and atraumatic continuous sutures].

A simple technique by twisting the thread in clockwise or counter clockwise direction before tightening the suture can help to produce a regular vascular suture line. In a blinded experiment with 60 vascular anastomosis it was proved that the time needed for suture can be reduced by 15%, and that traumatic touch with surgical instruments can be diminished by 63%.

Anastomosis, Surgical↗

[Gasless laparoscopic cholecystectomy. Our experience with 130 cases compared with 450 cases treated with the CO2 technique].

Alongside the technique based on the creation of an abdominal cavity for surgery following the introduction of gas (usually CO2) into the peritoneal cavity, a new method has been developed. This involves the use of an atraumatic mechanical lifting device connected to the same abdominal wall (gasless laparoscopy). The authors report a technique that uses an inflatable cushion inserted into the abdomen through a periumbilical incision. The cushion is connected to an external motorized hydraulic jack fixed to the operating table, fitted with an electric motor and friction gear. Between May 1991 and June 1998, 580 patients underwent laparoscopic cholecystectomy. Since December 1995 a total of 130 patients have undergone surgery using gasless laparoscopy. Shoulder pain and pain in the upper abdominal quadrant were no longer reported; pain was present in 70% of the patients operated using the CO2 technique. There was also a marked reduction in the anesthesiological risks, above all in elderly patients with cardiopulmonary insufficiency. Surgical manoeuvres are made easier owing to the possibility of using traditional surgical instruments. Washing and continuous aspiration allow a good control of intraoperative hemostasis, and reduce the phenomenon of lens misting without the risk of losing pneumoperitoneum. Less visibility of the surgical field was reported, particularly in obese patients, above all because of the reduced diaphragmatic distension and the lack of displacement of the intestinal loops. In the authors' opinion the gasless technique is suitable above all in patients affected by cardiopulmonary disorders in whom hypercapnia might represent a significant operating risk.

Carbon Dioxide↗

An evaluation of the AbTox Plazlyte Sterilization System.

OBJECTIVE: To evaluate the efficacy of the AbTox Plazlyte Sterilization System against selected microbial species using inoculated carriers and surgical instruments. SETTING: The microbiology laboratory of a 700-bed adult tertiary-care hospital. DESIGN: The study was conducted in two phases. In phase 1, microorganisms were inoculated to various metal, paper, plastic, and glass carriers, as well as surgical equipment, and processed in cycle II of the AbTox sterilizer. Phase 2 compared AbTox cycle III with ethylene oxide sterilization using stainless steel washers, penicylinders, and surgical equipment. In both phases, cultures of equipment and carriers were obtained after processing. The phenotypic profiles and antibiograms of positive cultures were compared to the original inoculate to rule out the possibility of contamination. RESULTS: Of a total of 350 paper carriers, 375 metal washers, and 234 pieces of equipment processed in cycle II and using trypticase soy broth as the inoculating medium, 123 metal washers (32%) and 8 instruments (3%) failed to be sterilized. Similar failures were noted with cycle III. The presence of either salt or protein adversely affected the system's ability to sterilize in either cycle. CONCLUSION: Further studies are needed to evaluate the extent to which salt or organic material compromise low-temperature gas-plasma sterilization. Meanwhile, users should exercise caution and use care in the cleaning of instruments that will be processed in the plasma-based sterilization technologies.

Adult↗

A review of lacrimal drainage surgery.

The advent of improved silicone intubation sets, increased understanding of lacrimal and nasal anatomy and physiology, and refinements in surgical instrumentation and technique have led to higher success rates in lacrimal surgery. Recent clinical studies, combined with new techniques in canalicular reconstruction, have helped identify which patients will benefit from surgical intervention and which techniques are indicated. Fortunately, this has greatly reduced the number of CDCRs necessary.

Dacryocystorhinostomy↗

100-minute retroperitoneoscopic radical nephrectomy: a new retroperitoneal approach with a hand assisted method.

PURPOSE: A new approach for retroperitoneoscopic radical nephrectomy is introduced. The point of our surgical method is the application of a combination of hand assistance and pure laparoscopic procedures with appropriate surgical steps via the retroperitoneal approach. In our early series we had good surgical results and we completed radical nephrectomy in about 100 minutes using this procedure. MATERIALS AND METHODS: A total of 20 consecutive patients with renal cell carcinoma (cT1-2) who were operated on with this surgical method were analyzed. Surgical procedures occurred in 5 steps. In step 1 the retroperitoneal space was created manually from a pararectal incision at the umbilicus level. In step 2 the lateroconal fascia was incised and the renal hilar area was exposed with hand assistance. In step 3 hilar dissection was performed by pure laparoscopic procedure with another surgical instrument inserted from the hand device. Step 4 involved the application of hand assistance again for the quick mobilization of the kidney and adrenal gland. In step 5 the intact surgical specimen was retrieved from the hand device. RESULTS: Mean operative time and estimated blood loss were 103 +/- 21 minutes (range 70 to 145) and 49 +/- 85 ml (range 5 to 360), respectively. Mean days to oral intake and ambulation were 1.0 and 1.1, respectively. Operative times of the steps of hilar dissection and mobilization of the kidney and adrenal were shorter than in other series performed by standard retroperitoneoscopic radical nephrectomy. Major complications were not experienced. At this point, no metastasis has been experienced. CONCLUSIONS: Our surgical method may have the benefits of the retroperitoneal approach and hand assistance. The retroperitoneoscopic hand assisted method may be another important option in the 3 major approaches for laparoscopic radical nephrectomy, although longer-term followup is clearly required.

Adult↗

Soft tissue surgery using radiowave techniques.

Numerous types of soft tissue surgical procedures can be performed using radiowave techniques. The Ellman International Surgitron is a versatile surgical instrument capable of making incisions, excisions, dessication, and coagulation. It converts electrical current into controlled energy in the radiowave frequency of the electromagnetic spectrum. Surgeons can then choose from three surgical currents based on the results they desire.

Adult↗

Management of a broken needle at the time of laparoscopic burch.

Loss of surgical instrumentation in endoscopic procedures poses problems not faced in traditional surgery. We describe the breakage and subsequent recovery of a 2-mm segment of needle from an Autosuture Endostitch device (U.S. Surgical) during a laparoscopic Burch urethropexy.

Carcinoma↗

Sutureless end-to-end bowel anastomosis using Nd:YAG and water-soluble intraluminal stent.

Sutureless end-to-end intestinal anastomoses were successfully constructed in 20 rabbits. A water-soluble intraluminal stent was used to approximate the tissue edges, and the anastomotic seam was lased with 1.06 microns neodymium:YAG (Nd:YAG) laser energy supplied through a hand-held 600-microns gas-cooled noncontact optical fiber. A continuous 5-watt wave of power was applied over periods ranging from 46 to 92 seconds to produce the tissue blanching and shrinkage that indicated a satisfactory tissue weld. Integrity, degree of tissue reaction, and bursting pressures of the anastomoses were compared to those of anastomoses constructed using standard sutured techniques. The results of the two methods were equivalent at 1 to 3 days, but the laser-fused enteric anastomoses showed less inflammatory reaction and greater bursting pressures at 7 and 14 days. Application of a variety of proteinaceous solutions including extracellular matrix materials and epidermal growth factors prior to lasing failed to augment wound healing. We conclude that lasers show promise as reconstructive, in addition to ablative, surgical instruments.

Anastomosis, Surgical↗

[Indications for and limitations of minimally invasive cardiac surgery with the lower ministernotomy approach].

The chief benefits of small skin incisions are reduced patient discomfort, accelerated recovery, and cosmetic satisfaction without compromising the quality of surgery. Since April 1997, the lower ministernotomy approach without femoral cannulation has been performed in 43 patients in the authors' institutions. The indications for this approach were initial single valve surgery and secundum-type atrial septal defect. Cases of aortic valve regurgitation that could be repaired, and aortic stenosis that necessitated annular enlargement were excluded. Among patients with mitral valve disease, those with chronic atrial fibrillation were excluded frpm undergoing the Maze procedure and those reguiring chordal reconstruction for anterior leaflet were also excluded. Mitral valve repair for mitral regurgitation was performed in 8 patients, and open mitral commissurotomy in 2. Mitral valve replacement was performed in 3 patients and aortic valve replacement in 13. Closure of an atrial septal defect was carried out in 18 cases. An approximately 10-cm median skin incision was made, and a ministernotomy with a lower semitransverse division (inverted L-shape) was carried out. Cardiopulmonary bypass was initiated with ascending aortic cannulation and right-angled venous cannulae in the superior and inferior vena cava for mitral valve disease. Single venous cannulae from the right atrial appendage was used for aortic valve disease. Surgery was performed with mild hypothermia and intermittent tepid blood cardioplegia with diltiazem. A rigid 30-degree angle scope held by a videoscope holder with a flexible arm was used for mitral valve surgery. There were one hospital death due to perioperative myocardial infarction and pulmonary embolism. There was one reopening for bleeding which resulted in methicillin-resistant Staphylococcus aureus mediastinitis. However, the patients was discharged after rectal muscle flap repair. There was one reoperation for mitral valve repair due to hemolysis. The improvement of surgical instruments and materials will further facilitate this procedure.

Adult↗

[Surgery in superficial skin lesions (II of III). Procedure: technique preparation].

The authors make a detailed presentation about the steps to follow to ensure the patient is comfortable and that the execution of this technique is correct. The authors review the most important aspects, including asepsis and anesthesia, to prepare a wound for suturing and to make preparations for surgery. They also provide a brief description of the necessary surgical instruments and their characteristics.

Dermatologic Surgical Procedures↗

Navigation in diagnosis and therapy.

Image-guided navigation for surgery and other therapeutic interventions has grown in importance in recent years. During image-guided navigation a target is detected, localized and characterized for diagnosis and therapy. Thus, images are used to select, plan, guide and evaluate therapy, thereby reducing invasiveness and improving outcomes. A shift from traditional open surgery to less-invasive image-guided surgery will continue to impact the surgical marketplace. Increases in the speed and capacity of computers and computer networks have enabled image-guided interventions. Key elements in image navigation systems are pre-operative 3D imaging (or real-time image acquisition), a graphical display and interactive input devices, such as surgical instruments with light emitting diodes (LEDs). CT and MRI, 3D imaging devices, are commonplace today and 3D images are useful in complex interventions such as radiation oncology and surgery. For example, integrated surgical imaging workstations can be used for frameless stereotaxy during neurosurgical interventions. In addition, imaging systems are being expanded to include decision aids in diagnosis and treatment. Electronic atlases, such as Voxel Man or others derived from the Visible Human Project, combine a set of image data with non-image knowledge such as anatomic labels. Robot assistants and magnetic guidance technology are being developed for minimally invasive surgery and other therapeutic interventions. Major progress is expected at the interface between the disciplines of radiology and surgery where imaging, intervention and informatics converge.

Diagnosis, Computer-Assisted↗

Bacterial strike-through of re-usable surgical drapes: the effect of different wetting agents.

Wound contamination and the resultant postoperative infection is a major problem in all forms of surgery. Air contamination, gloves, surgical instruments and drapes have all been investigated as sources of wound contamination. We investigated the effect of different wetting agents on strike-through rate of bacteria through re-usable polyester/cotton surgical drapes using a newly described method. Within 30 min bacterial strike-through of dry surgical drapes occurs. Wetting drapes with blood or normal saline enhances the strike-through rate of bacteria. Wetting drapes with iodine or chlorhexidine diminishes, but does not stop, bacterial strike-through. The use of re-usable polyester/cotton drapes is a potential source of wound contamination especially when wetted with blood or normal saline.

Bacteria↗

Rapid prototyping of temporal bone for surgical training and medical education.

OBJECTIVE: The skills of ear surgery are best developed by dissecting a temporal bone. However, only a limited number of trainees can be afforded this opportunity because of the scarcity of available bones. The aim of this study was to investigate the validity of a prototype temporal bone model for surgical training and education. MATERIAL AND METHODS: A simulated 3D model of a human temporal bone was made using a selective laser sintering method. The powder layers were laser-fused based on detailed CT data and accumulated to create a 3D structure. Conventional surgical instruments were used to dissect the model under a microscope. RESULTS: The model was as hard as real bone and surface structures were accurately reproduced. The model could be shaved using a surgical drill, burr and suction irrigator in the same way as a real bone. The malleus and incus were reproduced. The semicircular canals and the oval and round window niches were identified. Cavity structures, such as the semicircular canal, vestibule, antrum and air cells, were filled with powder which had to be removed using a pick and suction irrigator during dissection. A magnified model was useful for educating medical students. CONCLUSION: This prototype 3D model made using selective laser sintering serves as a good educational tool for middle ear surgery.

Humans↗