Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SILICONES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Removal of silicone oil from aphakia: use of a self-sealing corneal incision.

PURPOSE: To report and illustrate a modified and simple technique for silicone oil removal from aphakic eyes. DESIGN: Interventional case series. METHODS: Eighteen eyes of 18 patients who once had pars plana vitrectomy and lensectomy combined with silicone oil tamponade underwent silicone oil removal using a self-sealing corneal incision. RESULTS: All of the 18 silicone oil removal procedures performed had clear corneal incisions, which did not require suturing. CONCLUSIONS: Silicone oil can be removed successfully from aphakia using the self-sealing corneal incision under local anesthesia.

Adolescent↗

Migration of intraocular silicone into the cerebral ventricles.

PURPOSE: To report a case in which silicone oil in the eye migrated into the cerebral ventricles and the subarachnoid space. DESIGN: Observational case report. METHODS: A 62-year-old woman presented with proliferative diabetic retinopathy and tractive retinal detachment in her left eye. Par plana vitrectomy and injection of 5,000-centistoke-viscosity silicone oil were performed. Intraocular pressure was elevated after the operation and poorly controlled for 4 months. Eight months after the first operation, the patient felt dizzy. Computed tomography (CT), magnetic resonance imaging (MRI), and optical coherence tomography (OCT) scanning were performed. RESULTS: The CT imaging, MRI, and OCT showed silicone oils migrated into the sella cistena superioris and the cerebral ventricles. Follow-up examination was continued. CONCLUSION: Although silicone oil migrating into the ventricles is unusual, we suggest that every patient undergoing silicone oil tamponade with poorly controlled high intraocular pressure and optic disk atrophy should be carefully evaluated.

Brain Diseases↗

Results of silicone oil removal in patients with cytomegalovirus retinitis related retinal detachments.

PURPOSE: To evaluate the percentage and risk indicators leading to retinal redetachment in HIV (human immunodeficiency virus) patients with CMV (cytomegalovirus) retinitis related retinal detachments that were repaired with silicone oil, and then subsequently underwent oil removal. DESIGN: Retrospective, noncomparative interventional case series. METHODS: The study cohort consisted of a series of 15 eyes in 14 patients with HIV and CMV retinitis with a retinal detachment (RD) repaired with silicone oil at a single center and followed from the time of the CMV retinitis diagnosis through the time of silicone oil removal. Patient- and eye-specific data regarding demographic and clinical characteristics were collected retrospectively and statistical analyses were performed to compare differences between the eyes that had retinal detachments versus the eyes that remained attached following removal of silicone oil. RESULTS: Eight eyes (53%) redetached after a median of 4.0 months following oil removal. Cataract surgery performed at the time of oil removal was a statistically significant risk factor for redetachment (P = .01). There was a trend for lower CD4 levels to be associated with a higher risk of retinal redetachment. The use of a scleral buckle at the time of surgery (initial RD repair or at the time of oil removal) did not reduce the risk of redetachment. CONCLUSIONS: Approximately half of the eyes with CMV related retinal detachment may safely undergo oil removal. The risk factor for redetachment was simultaneous cataract extraction at the time of silicone oil removal. There was also a trend for lower CD4 levels to be associated with a higher risk of retinal redetachment.

AIDS-Related Opportunistic Infections↗

Measurement of bite force variables related to human discrimination of left-right hardness differences of silicone rubber samples placed between the incisors.

This study was designed to examine human subjects' ability to discriminate between spatially different bite pressures. We measured actual bite pressure distribution when subjects simultaneously bit two silicone rubber samples with different hardnesses using their right and left incisors. They were instructed to compare the hardness of these two rubber samples and indicate which was harder (right or left). The correct-answer rates were statistically significant at P < 0.05 for all pairs of different right and left silicone rubber hardnesses. Simultaneous bite measurements using a multiple-point sheet sensor demonstrated that the bite force, active pressure and maximum pressure point were greater for the harder silicone rubber sample. The difference between the left and right was statistically significant (P < 0.05) for all pairs with different silicone rubber hardnesses. We demonstrated for the first time that subjects could perceive and discriminate between spatially different bite pressures during a single bite with incisors. Differences of the bite force, pressure and the maximum pressure point between the right and left silicone samples should be sensory cues for spatial hardness discrimination.

Adult↗

Evaluation of mammalian cell adhesion on surface-modified porous silicon.

Porous silicon is a promising biomaterial that is non-toxic and biodegradable. Surface modification can offer control over the degradation rate and can also impart properties that promote cell adhesion. In this study, we modified the surface of porous silicon surface by ozone oxidation, silanisation or coating with collagen or serum. For each surface, topography was characterised using atomic force microscopy, wettability by water contact angle measurements, degradation in aqueous buffer by interferometric reflectance spectroscopy and surface chemistry by Fourier-transform infrared spectroscopy. The adhesion of rat pheochromocytoma (PC12) and human lens epithelial cells to these surfaces was investigated. Cells were incubated on the surfaces for 4 and 24 h, and adhesion characteristics were determined by using a fluorescent vital stain and cell counts. Collagen coated and amino silanised porous silicon promoted cell attachment for both cell lines whereas cells attached poorly to ozone oxidised and polyethylene glycol silanised surfaces. We showed that the two cell lines had different adhesion characteristics on the various surfaces at different time points. The use of the vitality assays Alamar Blue (redox based assay) and neutral red (active cellular uptake assay) with porous silicon was also investigated. We reveal incompatibilities between certain resazurin (Alamar Blue), lysosomal incorporation assays (neutral red) and porous silicon.

Animals↗

Microporous silicon and biosensor development: structural analysis, electrical characterisation and biocapacity evaluation.

An investigation of the fabrication of microporous silicon (MPS) layers as a material for the development of an electrolyte insulator semiconductor (EIS) capacitance sensor has been performed. The goal was to create a high surface area substrate for the immobilisation of biorecognition elements. Structural analysis of MPS layers as a function of key etch parameters, namely implant type (p or n), implant dose, hydrofluoric acid (HF) etch concentration and current density has been performed using scanning electron microscopy (SEM). It was possible to image porous layers with average pore diameter as low as 4 nm. n-type silicon samples had larger pore networks than p-type samples and reducing the silicon resistivity led to a reduction in the pores per microm2. It was found that increasing the HF etch concentration reduced the average pore diameter and increased the pores per microm2. Increasing the current density at which the etch was performed has the same effect. Understanding the effect of these parameters allows the MPS layer to be tuned to match specifications for optimum biocapacity. Different MPS layers were electrically characterised using capacitance-voltage and capacitance-frequency sweeps, in order to determine the effect of porosity on increases in surface area. The measured capacitance increased with increasing pores per microm2. p-type silicon with a boron implant in the back of the wafer, which had been etched in 25% HF in ethanol at a current density of 75 mA/cm2 yielded the highest capacitance signal per unit area. The effect of porosity and pore size on the biocapacity of the samples was also determined. For avidin immobilisation, with pores sizes above 5 nm, as the porosity increased the biocapacity increased. MPS fabricated in p-type silicon with a front and back implant etched in 25% HF at a current density of 25 mA/cm2 was used for the capacitance detection of synthetic oligonucleotides.

Biosensing Techniques↗

Towards a label-free optical porous silicon DNA sensor.

We report on the fabrication of an optical silicon-based label-free DNA sensor. n-Type crystalline silicon wafers have been electrochemically etched to form porous silicon layers and characterized in terms of porosity, pore distribution, surface composition and photoluminescence. Samples (0.25 cm(2)) have been cut and properly derivatized using trimethoxy-3-bromoacetamidopropylsilane in order to link single strand DNA (ss-DNA). Such a molecule is not commercially available and has been ad-hoc prepared by reacting hydrobromic acid and 3-aminopropyltrimethoxysilane in presence of 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide as coupling agent. Trimethoxy-3-bromoacetamidopropylsilane acts as a bridge anchored to the porous silicon surface through the silane group while immobilizing ss-DNA by means of the bromoacetamido moiety. We have found that derivatized samples exhibit a photoluminescence that is stable in time and is not modified after exposure to non-complementary DNA strand. On the other hand, a sensible enhancement of the light emission has been observed when the derivatized samples react with the complementary strand, showing that the specific ss-DNA/complementary DNA (c-DNA) interaction can be optically sensed without using further labeling steps. This strongly strengthens the possible role of silicon as a material for biosensors.

Biosensing Techniques↗

Study on accelerated evaluation system for release profiles of covered-rod type silicone formulation using indomethacin as a model drug.

The purpose of this study was to establish a method allowing rapid evaluation in vitro of the profiles of drug release from covered-rod type silicone formulation (CR silicone formulation), which releases drug for a prolonged period of time. Three CR silicone formulations containing indomethacin (IDM) with different release profiles were used in this study. The release of IDM was accelerated in a mixture of methanol and water (MeOH/water) compared with in phosphate-buffered saline (PBS) added by Tween 20 (PBS-based solvent). The velocity of IDM release varied depending on the composition of the MeOH/water. The change in release velocity was dependent on the solubility of IDM and the permeability of IDM through the silicone membrane. In all the tested formulations, the release rates of IDM estimated in 90% (v/v) MeOH/water were equally 14.6 times faster than those estimated in PBS-based solvent. Release of IDM from the cross-sections and lateral side evaluated by a bi-directional elution cell were accelerated in the MeOH/water in a similar degree. By introducing a common factor to shorten the time axis in all formulations, a fairly good agreement was observed between the two release profiles obtained in the accelerated MeOH/water system and the usual PBS-based solvent system. These results indicate that MeOH/water system enables to reduce the period for evaluation of profiles of drug release from CR silicone formulations in reflecting their release characteristics in usual PBS-based solvent system.

Chemistry, Pharmaceutical↗

Signal quality of biometry in silicone oil-filled eyes using partial coherence laser interferometry.

PURPOSE: To assess the practical feasibility and signal quality of axial length measurements by partial coherence laser interferometry in silicone oil-filled eyes with previous complicated vitreoretinal surgery. SETTINGS: Department of Ophthalmology, University Cologne, Cologne, Germany. METHODS: Using a Zeiss IOLMaster, axial length measurements and signal-to-noise ratios of optical biometry in silicone oil-filled eyes (n=45) and contralateral eyes without tamponade (n=41) were analyzed. RESULTS: Axial length measurements with signal-to-noise ratio > or =2 were feasible in 41 of 45 silicone oil-filled eyes (91%) and 37 of 41 eyes without tamponade (90%). Cataract, central retinal detachment, vitreous hemorrhage, and emulsified oil droplets attached to the intraocular lens were reasons for failure of partial coherence laser interferometry. The signal-to-noise ratio of the first 2 measurements was significantly smaller (P=.04) in silicone-filled eyes (4.4 +/- 2.0) than in eyes without tamponade (5.5 +/- 3.0). Axial lengths of the oil-filled eye and the contralateral eye showed a significant intraindividual correlation (P<.0001, Spearman r=0.84). CONCLUSIONS: Partial coherence laser interferometry shows good clinical practicability in silicone oil-filled eyes with previous complicated vitreoretinal surgery. Further studies are needed to assess the reliability of these measurements with regard to postoperative refraction after combined oil removal and cataract surgery.

Biometry↗

Topical anesthesia for transpupillary silicone oil removal combined with cataract surgery.

PURPOSE: To assess safety of topical anesthesia for transpupillary silicone oil removal in combination with cataract surgery. SETTING: Department of Ophthalmology Mannheim, University of Heidelberg, Mannheim, Germany. METHODS: The clinical interventional study included 37 consecutive patients having transpupillary silicone oil removal combined with cataract surgery. Without exception, surgery was carried out in topical anesthesia for all patients. During the study period, there were no patients having transpupillary silicone oil removal in another type of local anesthesia than topical anesthesia. Topical anesthesia was achieved with oxybuprocaine 0.4% eyedrops installed 4 to 5 times prior to surgery. Cataract surgery was performed using the clear cornea technique with implantation of a foldable intraocular posterior chamber lens. Silicone oil was released through a planned posterior capsulotomy during cataract surgery prior to implantation of the intraocular lens (IOL). RESULTS: For all patients, surgery could be carried out in topical anesthesia without switching to peribulbar or any other type of anesthesia. None of the patients complained about severe pain intraoperatively or postoperatively. No severe complications such as expulsive hemorrhage, luxation of the IOL, or iris incarceration were encountered in any of the surgeries. CONCLUSION: Transpupillary silicone oil through a planned posterior capsulotomy during cataract surgery may be performed in topical surgery.

Anesthesia, Local↗

Silicone implant arthroplasty in patients with idiopathic osteoarthritis of the metacarpophalangeal joint.

PURPOSE: The outcome of silicone metacarpophalangeal (MCP) joint implant arthroplasty in the osteoarthritic patient population has not been well established. Typically patients with idiopathic osteoarthritis have no history of underlying systemic disease and may respond well to treatment with MCP joint implant arthroplasty. This study examined the efficacy of silicone MCP joint implant arthroplasty for patients with idiopathic osteoarthritis for whom nonsurgical treatment had failed. METHODS: Of 14 patients (15 arthroplasties) who had silicone MCP joint implant arthroplasty for idiopathic osteoarthritis 12 (13 arthroplasties) returned for follow-up evaluation at an average of 40 months after surgery. There were 9 index finger and 4 middle finger arthroplasties. The average age at the time of surgery was 62 years. Patients completed a subjective questionnaire and were examined by a certified therapist. Range of motion and strength were recorded and the Jebsen-Taylor examination was administered to assess function. Range of motion values at final follow-up evaluation were compared with preoperative and early postoperative values. Radiographs were taken at final follow-up evaluation and compared with preoperative and early postoperative films to assess joint position, wear, and radioulnar alignment. RESULTS: At final follow-up evaluation excellent (9 patients) and good (3 patients) overall improvement were reported. Nine patients (10 implants) reported greater than 75% functional improvement. A notable increase was seen in MCP joint flexion. Grip and lateral pinch strengths were below age-matched normative data. Of the 11 patients (12 implants) who came in for follow-up evaluation 7 performed all tasks of the Jebsen-Taylor examination within the allotted time. At final follow-up evaluation all silicone implants were located and showed no signs of subluxation. Radiographic radioulnar alignment was maintained. One implant was revised at 35 months secondary to fracture. CONCLUSIONS: Silicone implant arthroplasty is a motion-sparing procedure that provides good pain relief and maintenance of function at intermediate follow-up evaluation in patients with idiopathic osteoarthritis of the MCP joint.

Aged↗

Surface calcification of a 3-piece silicone intraocular lens in a patient with asteroid hyalosis: a clinicopathologic case report.

OBJECTIVE: To illustrate the laboratory findings in a patient with bilateral asteroid hyalosis who presented with calcified deposits on a 3-piece silicone intraocular lens (IOL). DESIGN: Observational case report. METHODS: A 76-year-old diabetic woman underwent uneventful cataract surgery in 1994 with implantation of a silicone-optic polypropylene-haptic IOL in the left eye. A neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy was performed 2 years after cataract surgery, but persistent whitish deposits were observed on the posterior optic surface of the lens. Over the next 3 years, the opacification increased in the region corresponding to the capsulotomy. The IOL was explanted/exchanged. The right eye had cataract surgery in 1995. The acrylic lens implanted in this eye developed no opacities after 6 years. MAIN OUTCOME MEASURES: Gross, microscopic, and surface analyses of the explanted IOL. RESULTS: Gross and light microscopic analyses revealed the presence of confluent crustlike deposits on the central area of the posterior optic surface, as well as Nd:YAG pits. Individual spherules exhibiting a Maltese-cross pattern under polarizing light were also observed. Energy dispersive x-ray spectroscopic analyses demonstrated the composition of the confluent deposits to be similar to hydroxyapatite. CONCLUSIONS: An association between asteroid hyalosis and dystrophic calcification of IOLs has been reported only with silicone plate haptic designs. The material opacifying the 3-piece silicone lens probably was derived from the asteroid bodies or from the process that results in this vitreous condition. Clinical evaluation of other pseudophakic patients with asteroid hyalosis will confirm if this phenomenon is restricted to silicone IOLs.

Aged↗

Silicone oil emulsification in the anterior chamber after vitreoretinal surgery.

BACKGROUND: The use of silicone oil as an endotamponade for the treatment of complicated retinal detachment is common, but long-term complications can occur if the oil is not removed later. This article documents a case of emulsified silicone oil migration into the anterior chamber after vitreoretinal surgery and provides a discussion and review of common anterior segment complications from this condition. CASE REPORT: A 59-year-old man reported to the eye clinic complaining of a "growth" over his right eye that had increased in size over the last month. Slit lamp examination found a "reverse pseudohypopyon" in the right eye, which was actually emulsified silicone oil that had migrated from the posterior chamber after a previous retinal detachment repair. The patient was referred for surgical removal of this oily obstruction. Although surgical treatment was delayed for 18 months, his vision improved and his intraocular pressure was lowered through surgical and medical management. CONCLUSIONS: The use of silicone oil as an endotamponade in cases of complex retinal detachment has become common, but it also may lead to postoperative complications if it is not surgically removed later. This case highlights possible complications from the migration of emulsified silicone oil into the anterior chamber and illustrates the importance of follow-up care for every ophthalmic surgical procedure.

Anterior Chamber↗

The evaluation of microleakage and bond strength of a silicone-based resilient liner following denture base surface pretreatment.

STATEMENT OF PROBLEM: The failure of adhesion between a silicone-based resilient liner and a denture base is a significant clinical problem. PURPOSE: The purpose of this study was to examine the effects of denture base resin surface pretreatments with different chemical etchants preceding the silicone-based resilient liner application on microleakage and bond strength. The initial effects of chemical etchants on the denture base resin in terms of microstructural changes and flexural strength were also examined. MATERIAL AND METHODS: Forty-two polymethyl methacrylate (PMMA) denture base resin (Meliodent) specimens consisting of 2 plates measuring 30 x 30 x 2 mm were prepared and divided into 7 groups (n = 6). Specimen groups were treated by immersion in acetone for 30 (A30) or 45 (A45) seconds, methyl methacrylate monomer for 180 (M180) seconds, and methylene chloride for 5 (MC5), 15 (MC15) or 30 (MC30) seconds. Group C had no surface treatment and served as the control. Subsequently, an adhesive (Mollosil) and a silicone-based resilient denture liner (Mollosil) were applied to the treated surfaces, and all specimens were immersed in the radiotracer solution (thalium-201 chloride) for 24 hours. Tracer activity (x-ray counts), as a parameter of microleakage, was measured using a gamma camera. For bond-strength measurement, 84 rectangular PMMA specimens (10 x 10 x 40 mm) were surface-smoothed for bonding and treated with the different chemical etchants using the same previously described group configurations. The adhesive and the silicone-based denture liner were applied to the treated surfaces. Tensile bond-strength (MPa) was measured in a universal testing machine. Flexural strength measurement was performed with 49 PMMA specimens (65 x 10 x 3.3 mm according to ISO standard 1567) in 7 groups (n = 7), with 1 flat surface of each treated with 1 of the chemical etchants preceding adhesive application. The flexural strength (MPa) was measured using a 3-point bending test in a universal testing machine. The data were analyzed by 1-way analysis of variance and the Tukey HSD test (alpha = .05). RESULTS: Significant differences were found between the groups in terms of microleakage (P < .0001). The lowest microleakage was observed in group M180 (30,000 x-ray counts) and the highest in the control group (44,000 x-ray counts). The mean bond strength to PMMA resin ranged from 1.44 to 2.22 MPa. All treated specimens showed significantly higher bond strength than controls (P < .01). The flexural strength values all significantly differed (P < .05). All experimental specimens that had chemical surface treatments showed lower flexural strength than controls (P < .05). CONCLUSION: Treating the denture base resin surface with chemical etchants increased the bond strength of silicone-based resilient denture liner to denture base and decreased the microleakage between the 2 materials. Considering the results of both tests together, the use of methyl methacrylate monomer for 180 seconds was found to be the most effective chemical treatment.

Acid Etching, Dental↗

Candida albicans binds to saliva proteins selectively adsorbed to silicone.

Explanted voice prostheses obtained from 5 patients at the time of prosthesis replacement were consistently colonized by yeast, in particular Candida albicans. A simple, reproducible, in vitro model of C. albicans adherence to saliva-coated voice prosthesis silicone was developed. Whole saliva promoted adherence of C. albicans to silicone in a dose-dependent manner. Saliva rinses from voice prosthesis patients also promoted binding of C. albicans to silicone in vitro (mean adherence 14.9% +/- 2.8% of input C. albicans cells). This was significantly higher than C. albicans adherence to silicone in the absence of saliva (P < .001) or adherence promoted by saliva rinses from healthy volunteers (P < .005). Polyacrylamide gel electrophoresis analysis and a blot overlay adherence assay revealed that certain salivary proteins were selectively adsorbed to silicone and that C. albicans yeast cells adhered specifically to the adsorbed salivary proteins.

Adsorption↗

Silicone oil migration in the eyelid after vitrectomy for retinal detachment.

PURPOSE: To report a case of silicone oil intrusion in the upper eyelid, expressed by ptosis occurrence 19 years after surgery. METHODS: Vitrectomy followed by transscleral subretinal fluid drainage and silicone oil tamponade was performed on a 57-year-old man for retinal detachment. Nineteen years later, the patient was referred for mobile subcutaneous lumps of the upper right eyelid. Preoperative examination showed total invasion of the eyelid by silicone oil, as confirmed by pathology. RESULTS: Silicone oil leak developed through the transscleral drainage lumen and worsened with ocular hypertension. We assume that ptosis was induced by the weight of inflammatory tissue and consequently the development of a lymphoedema. CONCLUSION: We report a case of silicone ptosis. Two concomitant factors induced oil leakage: the puncture site and postoperative hypertonia.

Blepharoptosis↗

Incidence and management of cataract after retinal detachment repair with silicone oil in immune compromised patients with cytomegalovirus retinitis.

PURPOSE: To determine the incidence of and risk factors for cataract and to describe the visual outcomes of cataract surgery in eyes with cytomegalovirus-related retinal detachments repaired with silicone oil. STUDY DESIGN: Retrospective cohort study. METHODS: A prospectively generated database of all patients with cytomegalovirus retinitis examined at a single tertiary care institution was used to identify all cases of retinal detachment between October 1983 and August 1997. Data on retinal detachment repair, development of cataract, and outcomes of cataract surgery were obtained retrospectively. RESULTS: Among 904 eyes of 587 immune-compromised patients diagnosed with cytomegalovirus retinitis, 198 eyes of 155 patients developed retinal detachment. Among these, 106 eyes of 90 patients underwent retinal detachment repair with silicone oil. The Kaplan-Meier estimated median time to cataract was 1.8 months after surgery with silicone oil. The adjusted relative risk of cataract in eyes that underwent retinal detachment repair with silicone oil compared with eyes that did not was 6.74 (P <.0001). Eight of the eyes that developed cataract underwent uncomplicated cataract surgery by phacoemulsification and posterior chamber intraocular lens implantation. Among these, six eyes experienced >or=2 lines of improvement in visual acuity. All developed posterior capsule opacification a median of 7 days after cataract surgery. Four of five eyes that that underwent neodymium:yttrium-aluminum-garnet laser capsulotomy experienced >or=2 lines improvement in visual acuity. CONCLUSIONS: There is a high incidence of cataract after surgery with silicone oil tamponade for cytomegalovirus-related retinal detachment. Posterior capsule opacification occurs rapidly after cataract surgery in these patients.

AIDS-Related Opportunistic Infections↗

Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation.

PURPOSE: To report reduction in the area of anterior capsule opening at various postoperative intervals after continuous capsulorrhexis and to compare any differences in the area reduction between polymethylmethacrylate, silicone, and soft acrylic intraocular lenses. METHODS: Prospectively, 240 eyes of 240 patients undergoing phacoemulsification and intraocular lens implant surgery were randomized into three groups based on the type of intraocular lens used: polymethylmethacrylate, silicone, and soft acrylic. The area of the anterior capsule opening was quantitated, and examinations were performed at 1 week and 1, 3, and 6 months postoperatively. RESULTS: After intraocular lens implantation, the mean anterior capsule opening area 3 months postoperatively was significantly smaller than that at 1 week in all groups (polymethylmethacrylate, P = .0090; silicone, P < .0001; soft acrylic, P = .0127). Mean percentages in area reduction at both 3 and 6 months postoperatively were significantly greater than those at 1 week and 1 month (P < .0001). In comparing the three intraocular lenses at 1 week postoperatively, no statistical significance was observed regarding the anterior capsule opening area between the three groups. However, the mean anterior capsule opening areas in the polymethylmethacrylate and soft acrylic intraocular lens groups were significantly larger than those in the silicone intraocular lens group at 1 month (P = .0024), and 3 months (P = .0032), and 6 months (P = .0022) postoperatively. CONCLUSIONS: After continuous capsulorrhexis and intraocular lens implant surgery, the area of the anterior capsule opening gradually decreased for up to 3 months postoperatively. The contraction of the anterior capsule opening was greater in the silicone group than in either the polymethylmethacrylate or the soft acrylic groups.

Acrylates↗