Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SCINTILLATION COUNTER”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Standardisation of 89Sr using three different methods.

Three independent methods were used to standardise a 89Sr solution within the frame of an international comparison organised by BIPM/CCRI(II): 4pi liquid scintillation (LS) spectrometry, based on the CIEMAT/NIST efficiency tracing method, and direct activity measurements with a windowless 4pi CsI(Tl)-sandwich spectrometer and a 4pi pressurised gas proportional counter. Quantitative solid point-like sources were prepared paying special attention during the source drying phase. The impurities in the original solution were measured and corrected for in the results of all three methods. The activity concentration of 89Sr was found to be 26.21 +/- 0.08 kBq g(-1). A new half-life value for 89Sr of 50.61 +/- 0.05 days was determined from the LS measurements. The measurement methods, including the impurity measurements, are described and the results compared. considering the advantages and disadvantages of each method.

Journal Article↗

[Development of high-sensitivity radio gas chromatography--specific characteristics of a long path internal gas flow proportional counter (author's transl)].

A long path internal gas flow proportional counter was devised was to be used as a high sensitivity detector for radio gas chromatography, and its performance characteristics were investigated. The long path counter tube used for this detector has a sufficiently long passage in comparison with the diameter. The counter tube for general use is made of brass or copper tube 1 cm in diameter, 100 cm in length with a mirror finish on all internal surface, and the center electrode is of tungsten wire 0.05 mm in diameter. For actual use, several of these counter tubes are connected in series in assembly to hold the total volume of a gas sample in the counting system over a desired counting period. Thus this flow detector as an integral type one and gives directly a counting rate. Experiments showed that the dynamic counting efficiencies of tritium and carbon-14 were about 90% and equal to the static counting efficiencies. Furthermore, with this detector, the counting rate does not appear to be affected by minor variations of the effective inner volume of the counter tube and the flow rate of counting gas.

Carbon Radioisotopes↗

A technical analysis of an intraoperative radiation detection probe.

A technical evaluation was made of a commercial intraoperative radiation probe. This device utilizes a CsI (T1) scintillation detector and light pipe arrangement to count gamma radiation in vivo. After determining the optimal window and threshold setting, additional evaluations included linearity, distance response function, detector dead time, counter reproducibility, detector sensitivity, angular resolution, and energy resolution. Detector dead time (21.2 microseconds) was found to be characteristic of a nonparalysable system. Activity response for each radionuclide was linear (R = 0.99) both with and without collimation. Energy resolution, 25% at 210 keV, was not sufficient to separate the two photons (172 and 247 keV) emitted by 111In. Detector sensitivity was 1136 and 626 counts per s per microcurie of 111In and 99mTc, respectively. The mean effective distance from the face of the uncollimated probe to the crystal was determined to be 2.03 cm in air.

Antibodies↗

Identification of an unusual gamma counter fault using Trigg's technique for trend detection.

A simultaneous deterioration in performance of several radioimmunoassays suggested that equipment was malfunctioning. Replicate counts from an automated gamma counter showed unacceptable variation during a 24-hour period; this variation was detected using Trigg's technique, a sensitive method for trend analysis, and was not identified by the usual laboratory testing procedures. A defective capacitor was found in the voltage stabilisation unit in the gamma counter, which probably made it responsive to small variations in the power supply to the laboratory. It is suggested that the analysis of replicate counts using Trigg's technique is a valuable test of gamma counter function which should become routine.

Analysis of Variance↗

Standardization of 134Cs by three methods.

The nuclide 34Cs decays by beta-emission followed by gamma-deexcitation to 134Ba with a half-life T(1/2) = 2.065 a. It has been standardized by three methods: liquid scintillation counting (LSC), 4pi beta-gamma coincidence counting and 4pi gamma counting. In the LSC measurements, the CIEMAT/NIST method was used to calculate the efficiency. For the coincidence measurements, a conventional 4pi beta (proportional counter)-gamma(NaI) system was used. For the 4pi gamma standardization, a well-type Nal(Tl) detector was modeled with the Monte Carlo package PENELOPE, and the counting efficiency obtained by calculation. Results of the three methods agree within 0.65%.

Journal Article↗

Study of the influence of the LS-cocktail composition for the standardisation of radionuclides using the TDCR model.

The influence of the LS-cocktail on the value of the ionisation quenching kB factor was investigated. Sets of 3H and 63Ni standard sources in some commercial and home-made scintillators of different compositions were prepared and measured using the TDCR method. The Birks kB factor was determined for each LS-cocktail and the results are discussed. A model of anisotropy of the triple counter caused by PM-tubes defocusing was applied for calculation.

Journal Article↗

Implementation of the TDCR liquid scintillation method at CNEA-LMR, Argentina.

During the last two years, a triple-to-double coincidence ratio (TDCR) system was assembled and adjusted at the CNEA-LMR, Argentina. The new counting system will add complementary capabilities to the absolute measurements section of the CNEA-LMR. This work describes its implementation and validation. Several checks and a set of beta-emitting standard solutions were used in order to perform the validation experiments. In preliminary measurements, a 3H LNHB solution with reference activity concentration of (119.7+/-0.9) kBq/g on 11 November 2003 was used. The CNEA-LMR TDCR counter gave, at the same reference date, an activity concentration of (120+/-1) kBq/g. Results and improvements are presented in detail. Concerning the asymmetry of the system, the quantum efficiency of the three photomultiplier tubes was studied for different operating conditions of the focusing voltage. The counter also includes an automatic system to change the efficiency by defocusing the photomultipliers and on the other hand, it was coupled to a HPGe detector to also measure beta-gamma coincidences.

Algorithms↗

Standardization of 222Rn by LSC and comparison with alpha- and gamma-spectrometry.

Liquid scintillation counting (LSC) was used for the measurement of 222Rn in equilibrium with its daughters, with detection efficiency close to 5. The appropriate corrections were considered, including one related to the probability that the 165-micros half-life 214Po decays during the dead time of the counter initiated by the disintegration of his parent nuclide, 214Bi. The dead-time determination of a commercial LS counter is also presented using a 222Rn standard source. The LSC 222Rn sources were prepared by transfer of 222Rn produced by a solid 226Ra source into LSC cocktail frozen at 77K, flame-sealed afterwards. They were measured using the LNHB triple coincidence counter with adjustable extending-type dead-time unit, between 8 and 100 micros; two different procedures were used to calculate an effective dead time and then to deduce the counting rate extrapolated to zero dead-time value. The LSC results were compared with those obtained by cryogenic alpha-particle spectrometry (LNHB system) and by gamma-ray spectrometry for the same radon source in the LSC vial; the geometry transfer coefficient was calculated using the ETNA software. Measurement results and uncertainties are discussed.

Algorithms↗

Analysis of the neutron component at high altitude mountains using active and passive measurement devices.

The European Council directive 96/29/Euratom requires dosimetric precautions if the effective dose exceeds 1 mSv/a. On an average, this value is exceeded by aircrew members. Roughly half of the radiation exposure at flight altitudes is caused by cosmic ray-induced neutrons. Active (6LiI(Eu)-scintillator) and passive (TLDs) Bonner sphere spectrometers were used to determine the neutron energy spectra atop Mt. Sonnblick (3105 m) and Mt. Kitzsteinhorn (3029 m). Further measurements in a mixed radiation field at CERN as well as in a proton beam of 62 MeV at Paul Scherrer Institute, Switzerland, confirmed that not only neutrons but also charged particles contribute to the readings of active detectors, whereas TLD-600 and TLD-700 in pair allow the determination of the thermal neutron flux. Unfolding of the detector data obtained atop both mountains shows two relative maxima around 1 MeV and 85 MeV, which have to be considered for the assessment of the biologically relevant dose equivalent. By convoluting the spectra with appropriate conversion functions the neutron dose equivalent rate was determined to be 150 +/- 15 nSv/h. The total dose equivalent rate determined by the HTR-method was 210 +/- 15 nSv/h. The results are in good agreement with LET-spectrometer and Sievert counter measurements carried out simultaneously.

Aerospace Medicine↗

The assay of iodine-123.

Compounds labeled with 123I are becoming more common in scintillation imaging due to the convenient combination of the 13.3-hr half-life and the 159-keV gamma radiation. Here attention is drawn to the particularly large summing effects observed when 123I is counted in a well counter. These could lead to errors in the assay of doses if the analyzer windows used are too narrow.

Iodine Radioisotopes↗