Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Records”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Comparison of ERGs recorded with skin and corneal-contact electrodes in normal children and adults.

PURPOSE: Compare electroretinogram (ERG) responses to full-field stimuli recorded with corneal-contact and skin electrodes in healthy children and adults. METHOD: ERGs were recorded independently in two laboratories in children (aged 4-14 years) and adults (aged 20-62 years). A Burian-Allen (BA) electrode were used to test both children and adults in one laboratory. A Gold Foil (GF) electrode was used to test adults and skin electrodes to test children and adults in the other laboratory. Responses were recorded to full-field stimuli similar to those specified in the ISCEV Standard. Dark-adapted responses were also recorded over a 5 log unit range of stimulus energies. RESULTS: All ISCEV rod and cone responses were recorded in every subject with skin electrodes as well as with eye-contact electrodes. BA and GF amplitudes and latencies were similar for the majority of ISCEV responses. The waveform morphology of rod and cone skin electrode responses was similar to corneal electrode responses in children and adults. GF electrode responses were on average 4 to 5 times larger than skin electrode responses recorded in the same laboratory. After scaling skin electrode responses by 4.5 the distribution of response amplitudes was found to be similar to that for the eye-contact electrodes in both children and adults. Dark-adapted responses were recorded to all stimulus intensities in every subject with each type of electrode. B-wave S-R functions were evaluated by fitting the Naka-Rushton equation. Vmax was similar for BA and GF electrode responses and this was about 4 times greater than for skin electrode responses. Log (sigma) was similar for GF and skin electrodes but these differed significantly from the BA electrode. Vmax and log(sigma) were similar in adults and children for BA and skin electrode responses. CONCLUSION: ERGs to full-field stimuli can be recorded successfully with either eye-contact or skin electrodes.

Adolescent↗

The value of nasopharyngeal recording in psychiatric patients.

The utility of nasopharyngeal (NP) recording in psychiatry is controversial. To assess its value, 302 NP recordings from patients with psychiatric illnesses were reviewed. Among the 81 patients whose electroencephalograms (EEGs) demonstrated spikes or sharp waves, 10 patients (12%) were found to have epileptic foci at the mesiobasal temporal region recorded exclusively by NP leads. However, all of these recordings showed additional independent epileptic foci detected by scalp electrodes. Five patients (6%) had epileptic discharges simultaneously recorded from NP and scalp electrodes. No recording showed all epileptic discharges to be exclusively recorded by NP leads. These findings suggest that although NP recording may not be absolutely required to determine if an EEG contains epileptiform discharges, in a psychiatric population, it may be useful to detect additional epileptic foci at the mesiobasal temporal region.

Electrodes↗

Pseudo-on-line fast response microvessel dimensions video graphic recorder with electrical signal output.

The present article describes a new method of microvessel dimensions measurement in which a writing oscilloscope is used to continuously and graphically record the microvessel video signal from television microscopy at a fast rate of 50 records per second. Dimensions of interest, such as the microvessel red blood cell flux diameter, are then easily marked out manually from the graphic records and a dynamic electrical signal proportional to the dimensions is generated. The signal is then recorded on one channel of a multichannel voltage recorder and is synchronised with other experimental signals which have previously been recorded on-line during the experiment. The result is that the dimension signal appears to have been recorded on-line during the experiment as well. This is desirable for electronic signal correlation and processing. This method is useful when poor experimental conditions, commonly encountered, make automatic recording of microvessel dimension unsatisfactory and manual inspection and processing become necessary.

Animals↗

Intraoperative evoked potential monitoring of the spinal cord: enhanced stability of cortical recordings.

Intraoperative EP monitoring of spinal cord function depends upon a quickly obtained, reproducible EP. The records must be obtained in a hostile environment where artifacts and other sources of electrical noise cannot easily be eliminated: records are obtained continuously without interrupting the surgery. We studied EP reproducibility by measuring cortical EP amplitude range and latency range within individual patients. Reproducibility was enhanced by several changes in the stimulus and recording parameters: (1) Bipolar recording near the vertex (Cz-Pz, E1-E2) eliminated a significant amount of the artifacts and random variations seen in referential recordings. Bipolar recordings sacrifice some amplitude but the improved reproducibility is worthwhile. (2) Restricted filters (especially 30-3000 Hz) improve reproducibility still further, compared to the traditional open filters (1-1000 Hz). (3) Fast stimulation rates improve monitoring up to rates of about 5 stimuli/sec. At even faster rates too much amplitude attenuation usually occurs. Using these techniques stable intraoperative EPs were recorded from all 115 patients except those in whom EPs were abnormal even before surgery. Advantages and disadvantages compared to epidural recording techniques were discussed. Several further observations were made, including (1) monitoring could be done equally as well with stimulation either at the peroneal or at the posterior tibial nerve; (2) balanced nitrous oxide and narcotic anesthesia did attenuate EPs by about 60%, although this is not so much as to interfere seriously with monitoring.

Adolescent↗

Epidurally recorded cervical somatosensory evoked potential in humans.

Three slow wave components, P10, N13 and P18, can be seen in the cervical somatosensory evoked potential (CSEP) in response to median nerve stimulation recorded by an electrode in the epidural space at the dorsal aspect of the cervical spinal cord referenced to an electrode at the suprasternal notch. In the region of high CSEP amplitude, which extends over several cervical segments, the peak-to-peak amplitude is more than 10 microV, permitting observation of the CSEP slow waves in single, unaveraged records. The CSEP to finger nerve stimulation had a similar wave form and the same latencies (referred to the Erb's potential) as the CSEP to median nerve stimulation. The P10 activity is of presynaptic origin; it is generated in the brachial plexus, spinal roots and terminal branches of the primary sensory fibers. The N13 slow wave is of postsynaptic origin; however, the small wave on the ascending phase of this main postsynaptic component represents superimposed presynaptic activity. In bipolar epidural recordings, 3-5 fast waves are superimposed on the slow CSEP waves, which are of lower amplitude than the slow waves in unipolar recordings. The fast waves show a slight but progressive delay at the more rostral recording sites and are present even with high frequency stimulation, presumably reflecting activity in long ascending tracts. The surface recorded CSEP to median nerve stimulation is 4-7 times lower in amplitude than the CSEP in unipolar epidural recordings. The small wave on the ascending phase of N13 and the N13 peak of the unipolar epidural recordings had the same latencies as the surface N11 and N13 peaks.

Adolescent↗

Differential effects of spinalization on discharge patterns and discharge rates of simultaneously recorded nociceptive and non-nociceptive spinal dorsal horn neurons.

Recordings were made simultaneously from 2-5 neurons at the same site in the lumbar spinal dorsal horn of pentobarbital-anesthetized rats. Neurons were classified as low-threshold (LT) or multireceptive (MR) according to their responses to non-noxious mechanical or noxious radiant heat stimuli of the skin. At the same recording sites neurons could be encountered which belong to different classes and/or which had mechanoreceptive fields which did not overlap. Cold blocks of the upper or lower thoracic cord or transsections of the upper cervical cord were made to evaluate the effects of spinalization on both the rate and pattern of background activity and/or noxious heat-evoked responses of different dorsal horn neurons under identical experimental conditions. At 24 of 27 recording sites, spinalization had qualitatively or quantitatively different effects on the rate of background activity of simultaneously recorded neurons. Interspike interval (ISI) means of background activity were significantly reduced in 29 of 65 (44.6%) neurons, prolonged in 23 of 65 (35.4%) neurons, or unchanged in 13 of 65 (20%) neurons. MR neurons displayed a significantly higher incidence of decreased background activity 17 of 45 (37.8%) and a lower incidence of increased background activity (18 of 45, 40%) during spinalization than the LT neurons from which 1 of 12 (8.3%) decreased and 8 of 12 (66.6%) increased background activity. Almost all (95.4%) neurons changed their discharge patterns after spinalization. At 9 of 27 recording sites, the discharge patterns of simultaneously recorded neurons were affected differently by spinalization as revealed by the coefficient of dispersion of the interspike intervals (ISI), indicating changes in the tendency to discharge action potential in clusters (bursts). At the same recording sites the level of noxious heat-evoked responses of simultaneously recorded MR neurons was also differentially affected by spinalization. Nociceptive responses were significantly enhanced in 19 of 37 (51.4%) neurons (137.8 +/- 142.6% of control, mean +/- SD), reduced in 13 of 37 neurons (35.1%) (by 58.9 +/- 20.9%) and/or unchanged in 5 of 37 (13.5%) neurons. It is concluded that no general 'tone' of descending antinociception exists and that tonic descending excitatory and inhibitory systems may be active simultaneously modulating both the level and pattern of neuronal discharges.

Animals↗

Surface intraoral genioglossus EMG recording technique for kinesiologic studies.

Electromyographic (EMG) recordings from intraoral genioglossus surface electrodes were compared to fine-wire recordings of the left genioglossus muscle during selected activities that involved (1) rest, (2) tongue protrusion without resistance, (3) isometric tongue protrusion, (4) jaw opening without resistance, (5) isometric jaw opening, and (6) swallowing. Right and left lateral protrusions of the tongue were evaluated also. Recordings from both surface and fine-wire configurations showed similar onset times, relative amplitude changes, and cessation times of EMG activity during unresisted tongue protrusion and isometric tongue protrusion. Swallowing EMG activity occurred somewhat earlier and was longer in duration in the surface electrode recordings than the fine-wire recordings; however, maximum amplitudes occurred at similar times. Neither type of electrode recorded significant EMG activity during jaw opening or isometric jaw opening. These findings support the validity of recording EMG activity of the genioglossus muscle by surface recording electrodes supported by an acrylic appliance. The development of such an appliance may be an important biofeedback tool to control genioglossus activity during such activities as tongue thrusting.

Adult↗

Frequency of recording of diabetes on U.S. death certificates: analysis of the 1986 National Mortality Followback Survey.

We used data from the 1986 National Mortality Followback Survey to estimate the frequency of recording of diabetes on death certificates and to determine factors associated with recording of diabetes among decedents aged 25 years and older who died in the U.S. in 1986. Among 2766 decedents for whom a history of diabetes was provided by a personal informant, diabetes was recorded on an estimated 38.2% of death certificates and was listed as the underlying cause of death on an estimated 9.6%. The frequency of recording of diabetes was strongly related to age and duration of diabetes--among those aged 25-44 years who had had diabetes for 15 or more years, the frequency of recording was 71.9%. When other listed causes of death included conditions that may have been related to diabetes, such as cardiovascular disease, diabetes was recorded between 45 and 70% of the time, depending on the other causes. Diabetes is usually not recorded on death certificates, and the likelihood of recording is related to decedent characteristics, particularly age, duration of diabetes, and co-morbidity.

Adult↗

Severe bradyarrhythmias in patients with sleep apnoea: the effect of continuous positive airway pressure treatment: a long-term evaluation using an insertable loop recorder.

AIM: In this new era of insertable loop recorders, we studied obstructive sleep apnoea-hypopnoea syndrome (OSAHS) patients in order to evaluate their arrhythmias and the beneficial effect of Continuous Positive Airway Pressure treatment (CPAP), over a long-term period. METHODS AND RESULTS: We enrolled 23 patients (16 men, 50 +/- 11 years) with moderate and severe OSAHS. In all patients, an insertable loop recorder capable of monitoring the heart rhythm for 16 months was implanted. Cardiac pauses >3 s and bradycardic episodes <40 bpm during a 2-month period before, and for 14 months after, the CPAP application, were noted. In each period, the patients underwent two 24-h Holter recordings. Before treatment, 11 patients (47%) revealed severe cardiac rhythm disturbances, mostly nocturnal. Holter recordings showed disturbances in only 3 (13%) patients (P=0.039), those in whom the insertable loop device had recorded frequent episodes. Eight weeks after the initiation of treatment, the total number of the recorded episodes tended to decrease while, during the last 6 months of the follow-up, no episodes were recorded. CONCLUSION: Approximately half of OSAHS patients evidence severe cardiac rhythm disturbances, which are significantly reduced by CPAP. Holter recordings seem unable to precisely describe the incidence of severe brady-arrhythmias and the effect of treatment.

Bradycardia↗

Digital implantable loop recorders in the investigation of syncope in children: benefits and limitations.

BACKGROUND: Conventional diagnostic methods for detecting arrhythmogenic causes of syncope in children are poor. Digital implantable loop recorders are of proven value in adults. OBJECTIVES: The purpose of this study was to evaluate digital implantable loop recorders in the investigation of syncope in children. METHODS: We reviewed the clinical and technical records of 18 consecutive patients (6 female and 12 male; age <or=16 years) who received an implantable loop recorder from 1999 to 2005. RESULTS: Median age at implantation was 11.3 years (range 4.6-16.5 years). Median duration of the device in situ was 18 months (range 5-36 months). Median time to diagnosis was 6 months (range 1 day to 17 months). Two patients had a congenital heart defect. Ten children (56%) had an event, 9 (50%) of whom had diagnostic information; 5 (28%) had profound bradycardia or asystole; 2 (11%) had polymorphic ventricular tachycardia (VT); and 1 child had supraventricular tachycardia. One patient died, but the automatically activated recording was recorded over again after death. One child had sinus rhythm during syncope. One child with polymorphic VT had no auto-activation on two occasions, and the third activation was triggered by asystole after VT terminated. Sixteen patients (89%) had false-positive activations as a result of either artifact or sinus tachycardia. CONCLUSION: The digital implantable loop recorder is a useful diagnostic modality in children with unexplained syncope. However, the automatic detection algorithm is imperfect, missing genuine polymorphic VT and frequently interpreting muscle tremors as VT. Because of continuous overwriting by automatic detection, genuine arrhythmias may be over-recorded by artifact.

Adolescent↗

Evaluating the reliability of recorded fluid balance to approximate body weight change in patients undergoing cardiac surgery.

OBJECTIVES: The objective of this study was to investigate body weight change in adult patients undergoing cardiac surgery and to assess the accuracy of conventional recorded fluid balance charting methods to reflect this change in body weight. DESIGN: This was a descriptive study. SETTING: This study was conducted at the cardiac care unit and medical-surgical intensive care unit (ICU) of a private hospital in Melbourne, Australia. SUBJECTS: The subjects were 32 adult patients who underwent cardiac surgical procedures. Twenty-six were male, and the mean age was 67 years (range 36-84 years). Twenty-three patients underwent coronary artery bypass graft surgery, and nine patients underwent heart valve repair or replacement+/-coronary artery bypass graft surgery between December 2003 and May 2004. OUTCOME MEASURES: The measures were recorded fluid balance for the perioperative period together with body weight measurements from the night before surgery and immediately on discharge from the ICU. An additional body weight measurement on the seventh postoperative day provided a trajectory of body weight gain or loss for the period of hospitalization after surgery. A retrospective medical history audit and an HV-CS digital chair scale (A&D Mercury Pty Ltd, Victoria, Australia) were used to collect the data. RESULTS: Analysis revealed that 30 patients increased their body weight from the night before surgery until discharge from the ICU. The mean weight gain was 3.34 kg (standard deviation [SD] 1.17, 95% confidence interval 2.70-3.98, P<.001). The average preoperative body weight was 80.97 kg (SD 16.79), whereas the average ICU postoperative weight was 83.94 kg (SD 16.15). Twenty-six patients (81.25%) had returned to, or were below, their preoperative weight by their seventh postoperative day (M 2.96 kg, SD 2.24 kg, P<.05). The average recorded fluid balance during the perioperative period was +1.56 L (SD 2.59 L, P<.001) with a difference of 1.39 kg between the recorded fluid balance and measured body weight change. Three patients (9.75%) met the criteria for accurate recorded fluid balance, and eight patients (25%) experienced a net difference in the opposite direction between recorded fluid balance and body weight change during the perioperative period. CONCLUSION: Body weight in patients who undergo cardiac surgery was found to fluctuate over the perioperative period. Use of recorded fluid balance to reflect change in body weight for patients undergoing cardiac surgery was deemed unreliable. Further investigation of body weight change and scrutiny of conventional recorded fluid balance charting methods for patients who undergo cardiac surgery is needed.

Adult↗

Employing ICA and SOM for spike sorting of multielectrode recordings from CNS.

For classification of action potential shapes in multineuron recordings, we present a spike sorting system employing independent component analysis (ICA) and an unsupervised artificial neural network (Kohonen's self-organizing map, SOM). We focus on how ICA in the first stage of the spike sorting system can be used to address specific problems arising in recordings using multielectrode arrays in the CNS. Using real data recorded from the pontine nuclei in rats and simulated data, we evaluate the performance of several ICA algorithms to remove cross-talk between electrodes using data from continuous recording (or simulation). When using cut-out data, the standard format of extracellular spike recordings, new problems emerge and robust algorithms are needed. We demonstrate that several ICA algorithms show a good performance on cut-out data from multielectrode array recordings (simulated and real data). In tetrode recordings the same neuron is purposely recorded by several electrodes simultaneously and we show, how independent component analysis can be used in this case to identify redundant information and hence to compress relevant information, improving subsequent clustering of a SOM.

Action Potentials↗

Simultaneous recording of laser-evoked brain potentials and continuous, high-field functional magnetic resonance imaging in humans.

Simultaneous recording of event-related electroencephalographic (EEG) and functional magnetic resonance imaging (fMRI) responses has the potential to provide information on how the human brain reacts to an external stimulus with unique spatial and temporal resolution. However, in most studies combining the two techniques, the acquisition of functional MR images has been interleaved with the recording of evoked potentials. In this study we investigated the feasibility of recording pain-related evoked potentials during continuous and simultaneous collection of blood oxygen level-dependent (BOLD) functional MR images at 3 T. Brain potentials were elicited by selective stimulation of cutaneous Adelta and C nociceptors using brief radiant laser pulses (laser-evoked potentials, LEPs). MR-induced artifacts on EEG data were removed using a novel algorithm. Latencies, amplitudes, and scalp distribution of LEPs recorded during fMRI were not significantly different from those recorded in a control session outside of the MR scanner using the same equipment and experimental design. Stability tests confirmed that MR-image quality was not impaired by the evoked potential recording, beyond signal loss related to magnetic susceptibility differences local to the electrodes. fMRI results were consistent with our previous studies of brain activity in response to nociceptive stimulation. These results demonstrate the feasibility of recording reliable pain-related LEPs and fMRI responses simultaneously. Because LEPs collected during fMRI and those collected in a control session show remarkable similarity, for many experimental designs the integration of LEP and fMRI data collected in separate, single-modality acquisitions may be appropriate. Truly simultaneous recording of LEPs and fMRI is still desirable in specific experimental conditions, such as single-trial, learning, and pharmacological studies.

Adult↗

Can optical recordings of membrane potential be used to screen for drug-induced action potential prolongation in single cardiac myocytes?

INTRODUCTION: Potential-sensitive dyes have primarily been used to optically record action potentials (APs) in whole heart tissue. Using these dyes to record drug-induced changes in AP morphology of isolated cardiac myocytes could provide an opportunity to develop medium throughout assays for the pharmaceutical industry. Ideally, this requires that the dye has a consistent and rapid response to membrane potential, is insensitive to movement, and does not itself affect AP morphology. MATERIALS AND METHODS: We recorded the AP from isolated adult guinea-pig ventricular myocytes optically using di-8-ANEPPS in a single-excitation dual-emission ratiometric system, either separately in electrically field stimulated myocytes, or simultaneously with an electrical AP recorded with a patch electrode in the whole-cell bridge mode. The ratio of di-8-ANEPPS fluorescence signal was calibrated against membrane potential using a switch-clamp to voltage clamp the myocyte. RESULTS: Our data show that the ratio of the optical signals emitted at 560/620 nm is linearly related to voltage over the voltage range of an AP, producing a change in ratio of 7.5% per 100 mV, is unaffected by cell movement and is identical to the AP recorded simultaneously with a patch electrode. However, the APD90 recorded optically in myocytes loaded with di-8-ANEPPS was significantly longer than in unloaded myocytes recorded with a patch electrode (355.6+/-13.5 vs. 296.2+/-16.2 ms; p<0.01). Despite this effect, the apparent IC50 for cisapride, which prolongs the AP by blocking IKr, was not significantly different whether determined optically or with a patch electrode (91+/-46 vs. 81+/-20 nM). DISCUSSION: These data show that the optical AP recorded ratiometrically using di-8-ANEPPS from a single ventricular myocyte accurately follows the action potential morphology. This technique can be used to estimate the AP prolonging effects of a compound, although di-8-ANEPPS itself prolongs APD90. Optical dyes require less technical skills and are less invasive than conventional electrophysiological techniques and, when coupled to ventricular myocytes, decreases animal usage and facilitates higher throughput assays.

Action Potentials↗

Evaluation of different recording parameters to establish a standard for flash electroretinography in rodents.

Different electrodes and stimulus protocols commonly used for electroretinography in rodent eyes were compared for convenience of use, degree of damage to corneal epithelium, and for magnitude of amplitude, reproducibility, left versus right eye accuracy, and reliability of recorded parameters of the flash electroretinogram (ERG). Adult C57BL/6 pigmented mice and albino Wistar rats were used to determine scotopic ERGs in response to Ganzfeld or strobe-light stimulation and light-adapted (photopic) ERGs recorded from both eyes at the same time. Test-retest data were used for statistical analyses to compare a monopolar gold-wire contact lens electrode (CLE), a cotton-wick silver-silver chloride electrode (CSCE), a DTL fiber electrode (DTLE), and a circular stainless steel wire electrode (SSE). Corneas were evaluated for abrasion after ERG recordings using fluorescein staining and also for the time taken, ease of insertion, and re-insertions required for the different electrodes. Compared to CSCE, DTLE, and SSE, the ERG potentials recorded by CLE had significantly larger scotopic amplitudes and oscillatory potentials under strobe or Ganzfeld stimulation and for light-adapted ERG b-wave amplitudes in both mice and rats. In analyzing test-retest data of scotopic ERG a-wave and b-wave amplitudes, the intraclass correlation coefficient showed the best agreement for the CLE (range 0.61-0.94) compared to the SSE (0.13-0.77), DTLE (0.02-0.69), and CSCE (0.12-0.51). In mice and rats, logistic regression analyses revealed significant correlations for amplitudes of most scotopic ERG parameters between contralateral eyes obtained with CLE and for some ERG components recorded by SSE. When comparing ERG amplitudes for stimulation by strobe or Ganzfeld, the difference was least with the CLE compared to DTLE, CSCE, or SSE. The time taken to insert the four different electrodes was greatest for the CLE in both mice and rats. The extent of corneal abrasion resulting from electrode use in mice was largest for the SSE followed by the CLE. However, in rats there was almost no corneal damage after ERG recordings with the CLE. Because of the stability of eye contact, the CLE allows ERGs to be determined over a longer recording session. Recording of scotopic and photopic (light-adapted) ERGs in rodents with monopolar gold-wire contact lens electrodes provides greater amplitudes and higher reproducibility when compared to other commonly used corneal electrodes. These electrodes are significantly better overall than others that were evaluated and should be considered for a standard protocol to monitor retinal function in rodent eyes.

Analysis of Variance↗

Single-cell recording from the brain of freely moving monkeys.

Single-cell recording from the brain of non-human primates has traditionally been performed in monkeys seated in a primate chair. However, this arrangement makes long-term recordings difficult, causes stress that may confound the data, and prevents the manifestation of natural behaviors. Extending our previous neurophysiological studies in non-human primates (Ludvig et al. Brain Res. Protocols 2000;5:75-85), we have developed a method for recording the electrical activity of single hippocampal neurons in freely moving squirrel monkeys (Saimiri sciureus). The recording sessions lasted for up to 6 h, during which the monkeys moved freely around on the walls and the floor of a large test chamber and collected food pellets. Stable action potential waveforms were readily kept throughout the sessions. The following factors proved to be critical in this study: (a) selecting squirrel monkeys for the experiments, (b) using a driveable bundle of microwires for the recordings, (c) using a special recording cable, (d) implanting the microwires into the brain without causing neurological deficits, and (e) running the recording sessions in a special test chamber. The described method allows long-term extracellular recordings from the brain of non-human primates, without the stress of chairing, during a wide range of natural behaviors. Using this model, new insights can be obtained into the unique firing repertoire of the neurons of the primate brain.

Animals↗

Effects of recording media composition on the responses of Nafion-coated carbon fiber microelectrodes measured using high-speed chronoamperometry.

The present study concerns methodological issues of electrochemical recordings using Nafion-coated 30 microm diameter single carbon fiber microelectrodes for high-speed chronoamperometric measurements of biogenic amines. First, the single carbon fiber microelectrodes were coated with Nafion and dried at 85 vs. 200 degrees C and their recording properties were determined. Second, the effects of shifts in solution pH, ionic strength, changes in recording solution levels of Ca(2+) or Mg(2+) and temperature on the recording characteristics and sensitivity of Nafion-coated high temperature dried (200 degrees C) single carbon fiber microelectrodes for measures of dopamine were studied. These studies showed that the high temperature drying of the Nafion produced a microelectrode with better recording properties: higher selectivity for cations versus anions, increased differences between the reduction and oxidation current ratios for the identification of dopamine versus serotonin, and more rapid response times. In addition, these studies demonstrated that the chronoamperometric recordings were insensitive to small changes in pH and divalent cations such as Ca(2+) or Mg(2+). However, increases in ionic strength decreased the sensitivity of the microelectrodes, while increases in temperature produced increases in the sensitivity of the microelectrodes for biogenic amines. These data support that Nafion-coated high temperature (200 degrees C) dried microelectrodes have enhanced recording properties as compared to microelectrodes, which are coated with Nafion and dried at 85 degrees C. In addition, high-speed chronoamperometric recordings of biogenic amines are not affected by solution changes in divalent cations (Ca(2+) or Mg(2+)).

Animals↗

Motor unit action potentials recorded with concentric electrodes: physiologic implications.

Computer simulations of concentric needle electrode recording characteristics assume a hemisphere spatial recording territory for the electrode's core with the cannula shielding electrical activity arising from those muscle fibers located behind the cannula with respect to the electrode's core. It is also believed that the motor unit action potential's (MUAP) duration is generated by the number of muscle fibers within the electrode's hemispherical recording territory. This presumption suggests that rotating the needle will necessarily alter the number of muscle fibers within the hemispherical recording territory and hence lead to an alteration in MUAP duration. Comparisons were performed for different needle orientations with documentation of no statistically significant alteration in MUAP duration. Additionally, referential recording montages with the concentric needle electrode revealed that the electrode's core records MUAPs with durations comparable to those detected by the cannula. These findings strongly suggest that the recording territory of the concentric needle electrode, with respect to MUAP duration, is not a hemisphere but a sphere encompassing most if not all of the MUAP's muscle fibers in a manner similar to that of a monopolar needle. These findings have significant implications regarding presently used MUAP simulation techniques and require a reconceptualization of how the concentric needle electrode records electrical activity within a volume conductor.

Action Potentials↗