Aspects of panoramic radiography in general dental practice.

OBJECTIVES: To gather information on the types of panoramic x-ray equipment used in NHS dental practice and whether dentists satisfy the legal requirements for safety, to determine which practice personnel take panoramic radiographs and to assess the prevalence of the practice of 'routine' panoramic radiography among NHS dentists. DESIGN: Postal questionnaire survey of general dental practitioners carried out during 1997 in selected FHSAs in England and Wales. RESULTS: 542 dentists returned the questionnaire, a 73.3% response. Panoramic x-ray equipment ranged in age from 27 years old to new, with 42.2% exceeding 10 years in age. The overwhelming majority of GDPs satisfied the requirement for regular maintenance and surveying of equipment. Almost all dentists (95.9%) performed a history and clinical examination prior to panoramic radiography but 42% practised 'routine screening' of new adult patients. A substantial proportion (36.7%) of dentists used unqualified personnel to take panoramic radiographs. CONCLUSIONS: While some aspects of this study give reassurance about the prevalence of good practice, widespread panoramic screening and using unqualified staff to take radiographs causes concern. These findings have implications for educators and for those involved in maintaining clinical standards.

Adult↗

Trabecular bone pattern of the mandible. Comparison of panoramic radiography with computed tomography.

OBJECTIVES: To analyse the possible correlation between the trabecular bone pattern of the edentulous mandible visualized by panoramic radiography and the bone mineral density (BMD) measured by computed tomography (CT). METHODS: Panoramic radiography and CT were performed on 28 patients with edentulous mandibles. The trabecular bone pattern of 47 regions on the panoramic radiographs was classified into one of five grades. BMD was measured within circular regions of interest on the axial CT images in the corresponding trabecular area. The gradings were correlated with the CT values using one-way analysis of variance. RESULTS: There was a significant correlation between the grade of the trabecular bone pattern and the BMD (P < 0.0001). CONCLUSION: The proposed classification for the trabecular bone pattern on panoramic radiographs might be a useful aid for the evaluation of the edentulous mandible prior to implant placement.

Adult↗

Digital radiography and caries diagnosis.

Direct digital acquisition of intra-oral radiographs has been possible only in the last decade. Several studies have shown that, theoretically, there are a number of advantages of direct digital radiography compared with conventional film. Laboratory as well as controlled clinical studies are needed to determine whether new digital imaging systems alter diagnosis, treatment and prognosis compared with conventional methods. Most studies so far have evaluated their diagnostic performance only in laboratory settings. This review concentrates on what evidence we have for the diagnostic efficacy of digital systems for caries detection. Digital systems are compared with film and those studies which have evaluated the effects on diagnostic accuracy of contrast and edge enhancement, image size, variations in radiation dose and image compression are reviewed together with the use of automated image analysis for caries diagnosis. Digital intra-oral radiographic systems seem to be as accurate as the currently available dental films for the detection of caries. Sensitivities are relatively high (0.6-0.8) for detection of occlusal lesions into dentine with false positive fractions of 5-10%. A radiolucency in dentine is recognised as a good predictor for demineralisation. Radiography is of no value for the detection of initial (enamel) occlusal lesions. For detection of approximal dentinal lesions, sensitivities, specificities as well as the predictive values are fair, but are very poor for lesions known to be confined to enamel. Very little documented information exists, however, on the utilization of digital systems in the clinic. It is not known whether dose is actually reduced with the storage phosphor system, or whether collimator size is adjusted to fit sensor size in the CCD-based systems. There is no evidence that the number of retakes have been reduced. It is not known how many images are needed with the various CCD systems when compared with a conventional bitewing, nor how stable these systems are in the daily clinical use or whether proper cross-infection control can be maintained in relation to scanning the storage phosphor plates and the sensors and the cable. There is only sparse evidence that the enhancement facilities are used when interpreting images, and none that this has changed working practices or treatment decisions. The economic consequences for the patient, dentist and society require examination.

Contrast Media↗

Cleidocranial dysplasia: radiological appearances on dental panoramic radiography.

OBJECTIVE: To report the effectiveness of dental panoramic radiography in identifying features pathognomonic for cleidocranial dysplasia. METHODS: Panoramic radiographs of nine male Caucasian patients with cleidocranial dysplasia are analysed. RESULTS: In addition to the established dental complications of failure of eruption of the permanent dentition and multiple supernumerary teeth, morphological abnormalities of the maxilla and mandible, particularly in the ascending ramus and coronoid process were present. CONCLUSION: Dental panoramic radiography is a valuable adjunct in confirming the diagnosis of cleidocranial dysplasia.

Adolescent↗

A comparison of the diagnostic utility of two image receptors for panoramic radiography.

OBJECTIVE: To compare the diagnostic utility of two screen-film systems for panoramic radiography, one based on green and the other on ultraviolet light. MATERIALS AND METHODS: Two hundred consecutive adult patients with teeth in all four quadrants requiring panoramic radiographs were randomly allocated to one of two groups. One group was imaged with OGA L (CEA AB, Strängnäs, Sweden) film using Lanex Regular (Eastman Kodak, Rochester, NY, USA) screens (the Lanex group). The other group was imaged using Ultra-Vision (Dupont UK Limited, Hertfordshire, UK) film and screens (the Ultra-vision group). Two different panoramic machines were used, a Planmeca (Planmeca OY, Helsinki, Finland) and Cranex (Soredex Orion Corporation, Helsinki, Finland). The radiographs were evaluated by two radiographers for overall quality and any faults recorded. Two dental radiologists evaluated the crestal and apical areas of every standing tooth on a 4-point scale. The likelihood of getting a high-quality image with the different films was modelled using logistic regression, adjusting for the radiologist and the area of the tooth being examined. Inter- and intra-examiner agreement was calculated using Kappa and weighted Kappa where appropriate. RESULTS: The radiographers recorded no significant differences in positioning errors between the two groups of film. However, the films produced on the Cranex were less likely to be recorded as excellent. The radiologists' interexaminer agreement for the lower molars and upper incisors was only moderate at best (kappa = 0.56). No significant differences were found between the likelihood of the two types of film providing a high-quality image. Crestal areas were more likely to be scored well than apical areas. CONCLUSION: There were no differences in ease of discerning apical and crestal areas between the two screen-film systems. There was only poor to moderate agreement between the two radiologists. Ultra-Vision can be recommended as an alternative to existing rare earth systems for panoramic radiography.

Adult↗

Optimisation of patient doses in programmable dental panoramic radiography.

OBJECTIVES: To estimate the radiation-related risk associated with twelve imaging programs available on the Orthophos (Siemens, Erlangen, Germany) dental panoramic radiography unit. METHODS: Organ absorbed doses for each program were measured using a Rando anthropomorphic phantom loaded with thermoluminescent dosemeters. Effective dose (E) was calculated in two ways; first, using the method recommended by the International Commission on Radiological Protection, which excludes the salivary glands (designated Eexc), and second, with its inclusion (designated Einc). Organ and effective doses were both used to compare the various imaging programs. RESULTS: In 11 of the 12 programs studied the salivary glands received the highest individual organ dose, and Einc was found to be up to double Eexc. When the image was restricted to the dentition (program 2) organ doses were lower than for the complete jaws (program 1) by up to 85%, and Eexc and Einc reduced by about one half. When programs 2 and 6 (to image the temporomandibular joints) are used in place of program 1, the former combination provides more image information at an equivalent risk. CONCLUSIONS: The value of E in panoramic radiography depends on the inclusion of the salivary glands in the calculation and the magnitude of the dose.

Absorption↗

Paediatric absorbed doses from rotational panoramic radiography.

OBJECTIVES: To determine the paediatric doses in rotational panoramic radiography with film/screen and photostimulable phosphor receptors. STUDY DESIGN: A paediatric anthropomorphic head and neck phantom was used. Absorbed doses were measured for two panoramic systems, the Orthophos (Sirona Dental Systems, Bensheim, Germany) and the PM 2002 CC (Planmeca Oy, Helsinki, Finland), with and without programmable child settings, using both screen/film and photostimulable phosphor receptors. RESULTS: Absorbed doses to the eye ranged from 5 to 24 micro Gy. Doses to the dental arches with the Orthophos unit ranged from 50 to 555 micro Gy with the adult and from 27 to 436 micro Gy with the child program; using the PM 2002 CC unit, doses ranged from 56 to 1040 micro Gy using the adult settings, and from 60 to 890 micro Gy with the paediatric settings. The paediatric exposure settings reduced doses at most locations for both panoramic systems. The highest doses were measured near the rotational axes of the X-ray beam. Paediatric settings with the Orthophos P10 resulted in the dose reduction more than 50% to the thyroid but not with the PM 2002 CC. When lower kVcp or mA settings were used, absorbed doses were effectively reduced for all combinations of machines, programs and detectors. CONCLUSIONS: Specific program settings for children reduced the absorbed doses from panoramic radiography irrespective of the machine or receptor used.

Absorption↗

A comparison of the effective dose from scanography with periapical radiography.

OBJECTIVES: To compare organ and effective doses from analogue scanographic and periapical radiography. METHODS: Thermoluminescent dosimeters (TLD-700) were inserted in the parotid glands (bilateral), submandibular glands (bilateral) and bone marrow (left ascending ramus) of three human cadavers. Dosimeters were also attached to the skin, thyroid gland and lens of both eyes. Central, left lateral and left posterior scanograms were obtained with a Cranex Tome (Soredex, Helsinki, Finland) multimodal imaging system. A similar procedure was applied for periapical radiographs of the midline, left lateral and left molar regions using E-speed film both with and without rectangular collimation. Organ and effective doses were calculated for scanograms and periapical radiographs. RESULTS: The effective doses for the scanograms were 0.001 mSv (central), 0.011 mSv (lateral) and 0.015 mSv (posterior). The effective doses for periapical radiographs were 0.001 mSv (anterior), 0.001 mSv (lateral) and 0.003 mSv (posterior) for rectangular collimation and 0.001 mSv (anterior), 0.002 mSv (lateral) and 0.005 mSv (posterior) for round collimation. CONCLUSIONS: When a larger area of the upper or lower jaw needs to be visualised, scanograms might be considered as an alternative to periapical radiography since the effective dose is lower.

Bone Marrow↗

Survey of radiography and radiation protection in general dental practice in Uganda.

OBJECTIVES: To carry out the first survey in Uganda of all dentists and all public health dental officers (PHDO) to assess the status of dental radiography and radiation protection. METHODS: All 74 dentists and 76 PHDOs in Uganda were sent a postal questionnaire including 33 questions relating to various demographic details, radiographic equipment and radiographic techniques, including processing and radiation protection. A second questionnaire was sent to non-respondents after 3 months. RESULTS: Eighty-two per cent of dentists responded and 83% of PHDOs. Seventy per cent of the dentists and 100% of the PHDOs were trained in Uganda. Seventy-five per cent of the dentists and 30% of the PHDOs had access to one of the approximately 30 X-ray machines in the country. The majority of the equipment did not comply with current recommendations in Europe. Fifty-one per cent of dentists used machines with mechanical timers, 28% used machines with no visual warning signal and 17% used equipment with no audible warning signal. Most of the equipment was over 30 years old and only 15% of dentists knew when the equipment was last serviced. The most relevant finding of the surveys was the level of 'don't know' responses to many questions from both groups. CONCLUSIONS: The lack of knowledge regarding dental radiography and radiation protection plus the condition of most equipment in Uganda is a matter of concern. Standards of care are considerably lower than in developed countries requiring improved undergraduate training, provision of postgraduate courses and Ugandan governmental or international financial assistance.

Adult↗

Artifacts due to movement in rotational panoramic radiography.

Image quality due to movement of the patient during the exposure is a common problem in conventional radiography. The resulting artifacts in the image are characteristic and easily identifiable blurring. The unique mechanics of image production and the prolonged exposure time used in rotational panoramic radiography can cause very different disturbances in the diagnostic image. The illustrations presented here are extreme examples of such artifacts, selected for clear illustration in a printed image. The challenge to the clinician is to identify the full spectrum of such distortions, from the obvious ones to the much more subtle effects of similar minor distortions that may not be so easily recognized as artifacts.

Head↗

The effect of vertical and horizontal head positioning in panoramic radiography on mesiodistal tooth angulations.

The purposes of this study were to examine the effect of potentially common patient positioning errors in panoramic radiography on imaged mesiodistal tooth angulations and to compare these results with the imaged mesiodistal tooth angulations present at an idealized head position. A human skull served as the matrix into which a constructed typodont testing device was fixed according to anteroposterior and vertical cephalometric normals. The skull was then repeatedly imaged and repositioned five times at each of the following five head positions: ideal head position, 5 degrees right, 5 degrees left, 5 degrees up, and 5 degrees down. The images were scanned and digitized with custom software to determine the image mesiodistal tooth angulations. Results revealed that the majority of image angles from the five head positions were statistically significantly different than image angles from the idealized head position. Maxillary teeth were more sensitive to 5 degrees up/down head rotation, with 5 degrees up causing mesial projection and 5 degrees down causing distal projection of maxillary roots. Mandibular anterior teeth were more sensitive to 5 degrees right/left head rotation, with the projected mesiodistal angular difference between 5 degrees right and 5 degrees left rotation ranging from 4.0 degrees to 22.3 degrees. Maxillary teeth were relatively unaffected by 5 degrees right/left head rotation, and mandibular teeth were relatively unaffected by 5 degrees up/down head rotation. It was concluded that the clinical assessment of mesiodistal tooth angulation with panoramic radiography should be approached with extreme caution with an understanding of the inherent image distortions that can be further complicated by the potential for aberrant head positioning.

Cephalometry↗

A comparative study of a digital radiography system.

The present study aimed to examine the efficiency of a new digital radiography system that was installed in the Royal Adelaide Hospital in September 1997, as compared to the existing conventional radiography system. A total of 55 examinations were observed over a 3-week period in January, and these consisted of 18 digital and 10 conventional chest examinations, and 27 conventional orthopaedic examinations. These were combined with 18 digital orthopaedic examinations recorded from a prior study. Total examination time was broken into several components, of which reporting time was of the most interest. The mean reporting times for digital and conventional chest examinations were 17 and 25 min, respectively, a significant (P < 0.1) 8-min difference. The orthopaedic examinations revealed mean reporting times of 8 and 26 min for digital and conventional systems, respectively; a significant (P < 0.001) 18-min difference. These results demonstrate that the digital system is a faster, more efficient system for the reporting of X-rays.

Data Collection↗

A time-motion study of digital radiography at implementation.

With increasing budgetary restraints on the health system, it is apparent that the main contribution that radiology departments can make to significant cost reduction in hospitals is to decrease the length of time between requesting an X-ray examination and receiving the report (and images). Digital radiography (DR) was introduced into the Radiology Department at the Royal Adelaide Hospital as a pilot project to research the cost-benefits and efficiency of the system, and to determine future directions for planning a digital department. The business plan developed prior to implementation of this pilot project predicted a saving of one bed-day per inpatient when a fully digital department with a picture archiving and communication system (PACS) is installed. This initial study comparing DR and conventional radiography (convR) provides baseline data and shows encouraging results for more rapid transmission of reports to clinicians.

Cost-Benefit Analysis↗

[ROC analysis in post-processing of image data in digital thoracic radiography].

PURPOSE: To examine the extent to which digital luminescence radiography (DLR) can be used for the imaging of pulmonary nodules and interstitial lung disease in chest radiography without any loss of image quality. Additionally: to examine whether post-processing of image data can optimise the recognizability of varied image details. MATERIALS AND METHODS: Detail perceptibility studies were performed on an anthropomorphic thorax phantom with simulated nodules and small linear and reticular details. Under standard conditions, digital luminescence radiographs were obtained in 7 different image modes, and these were compared with a 200-speed screen-film system. The detection of these systems was evaluated in an ROC analysis on the basis of 19,200 individual observations. RESULTS: Edge enhancement or application of high-frequency-enhancing small filter kernels (S 5) slightly improves the detection of linear structures; however, the illustration of nodular details is markedly reduced. Larger filter kernels (S 20, S 40) make a definitive detection possible--not only of circular, but also of linear details. CONCLUSIONS: Storage phosphor radiographs are equal to the tested analog screen-film-system. The optimization of post-processing can be helpful in the prevention of routine multiple documentations.

Adult↗

[Digital radiography in thoracic diagnosis].

Technologies and performance of digital projection radiography are reviewed. Storage phosphor imaging plates can be used in existing diagnostic equipment and the resulting digital images permit the recognition of fine interstitial changes, if a high frequency edge enhancement is performed. While a generalized enhancement of low and medium spatial frequencies and a grey scale reversal do not improve the detectability of pulmonary nodules, selective enhancement of low frequencies in the mediastinal and retro-diaphragmatic areas may well improve diagnostic performance. Dose can be reduced if the resulting signal-to-noise ratio is adequate for diagnosis. Further dose savings can be achieved by the reduced number of retakes. Dual energy techniques improve the detectability and differential diagnosis of pulmonary nodules. The further development of picture archiving and communication systems (PACS) will turn the digital projection radiography into the method of choice for the diagnosis of chest disease.

Humans↗

[Clinical results of dual-energy radiography in thoracic studies].

Dual energy methods permit the reconstruction of either soft tissue or calcium density structures. The value of the technique is demonstrated in 220 patients. Demonstration of the thoracic organs without superimposition of the skeleton improves the recognition of pulmonary lesions. Opacities related to ribs no longer simulate pulmonary lesions. The mediastinal borders are demonstrated more clearly by double spectrum radiography than by any other radiographic method. Soft tissue calcification can be shown with a high degree of sensitivity. Skeletal changes which may be obscured by overlapping soft tissue shadows on conventional radiography can also be diagnosed by this technique.

Humans↗

[Digital radiography. Experiences with the SP system].

Digital radiography which would have to replace conventional radiography with equal or improved quality is the still missing link in the development of a fully digital imaging department of the future. Various attempts have been made to close this gap. This article describes the SP system, a large area detecting digital imaging system, originally designed by Fuji. Its components are the imaging plate, coated with a stimulable phosphor (SP), which is used like a conventional film-screen cassette, a laser-based image reader, the image processor and a laser-based image printer. After a six months' test in hospital routine, the advantages, shortcomings and possible improvements are discussed.

Analog-Digital Conversion↗

Validity of a set of clinical criteria to rule out injury to the cervical spine in patients with blunt trauma. National Emergency X-Radiography Utilization Study Group.

BACKGROUND: Because clinicians fear missing occult cervical-spine injuries, they obtain cervical radiographs for nearly all patients who present with blunt trauma. Previous research suggests that a set of clinical criteria (decision instrument) can identify patients who have an extremely low probability of injury and who consequently have no need for imaging studies. METHODS: We conducted a prospective, observational study of such a decision instrument at 21 centers across the United States. The decision instrument required patients to meet five criteria in order to be classified as having a low probability of injury: no midline cervical tenderness, no focal neurologic deficit, normal alertness, no intoxication, and no painful, distracting injury. We examined the performance of the decision rule in 34,069 patients who underwent radiography of the cervical spine after blunt trauma. RESULTS: The decision instrument identified all but 8 of the 818 patients who had cervical-spine injury (sensitivity, 99.0 percent [95 percent confidence interval, 98.0 to 99.6 percent]). The negative predictive value was 99.8 percent (95 percent confidence interval, 99.6 to 100 percent), the specificity was 12.9 percent, and the positive predictive value was 2.7 percent. Only two of the patients classified as unlikely to have an injury according to the decision instrument met the preset definition of a clinically significant injury (sensitivity, 99.6 percent [95 percent confidence interval, 98.6 to 100 percent]; negative predictive value, 99.9 percent [95 percent confidence interval, 99.8 to 100 percent]; specificity, 12.9 percent; positive predictive value, 1.9 percent), and only one of these two patients received surgical treatment. According to the results of assessment with the decision instrument, radiographic imaging could have been avoided in the cases of 4309 (12.6 percent) of the 34,069 evaluated patients. CONCLUSIONS: A simple decision instrument based on clinical criteria can help physicians to identify reliably the patients who need radiography of the cervical spine after blunt trauma. Application of this instrument could reduce the use of imaging in such patients.

Cervical Vertebrae↗