Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyethylene”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Characterization of polyethylene glycol-modified proteins by semi-aqueous capillary electrophoresis.

A new program to characterize polyethylene glycol-modified (PEGylated) proteins is outlined using capillary zone electrophoresis (CZE). PEGylated ribonuclease A and lysozyme were selected as examples. Five separation procedures were compared to select out the mixed buffer of acetonitrile-water (1:1, v/v) at pH 2.5 as the best to characterize the PEGylated proteins without sample pretreatment. Polyethylene oxide (PEO) with a high molecular mass of 8 x 10(6) was applied to rinse the capillary to form a dynamic coating which would decrease the undesirable proteins adsorbed to the inner wall of the silica. The electroosmotic flow (EOF) mobility of the five procedures was determined, respectively. It is found that acetonitrile is mainly responsible for the good resolution of PEGylated proteins with the help of PEO coating in the semi-aqueous system. The low EOF mobility and current in the semi-aqueous system might also have some responsibility for the high resolution. The semi-aqueous procedure described in this paper also demonstrates higher resolution of natural proteins than aqueous ones.

Electrophoresis, Capillary↗

Effect of polyethylene occlusive skin wrapping on heat loss in very low birth weight infants at delivery: a randomized trial.

OBJECTIVE: Significant evaporative heat loss in the very low birth weight infant can occur in the delivery room. We investigated the effect of polyethylene wrap applied immediately at birth (without drying) on rectal temperature measured at nursery admission. STUDY DESIGN: Sixty-two consecutive infants delivered at <32 weeks' gestation were stratified by gestational age and randomly allocated to resuscitation with polyethylene wrap. All infants were resuscitated under radiant warmers. Wraps were removed on nursery admission. Rectal temperature was taken by digital electronic thermometer. RESULTS: Fifty-nine of 62 recruited infants completed the study. Maternal temperature, delivery room temperature, transfer-incubator temperature, and time to admission were recorded. Use of occlusive wrapping resulted in a significantly higher admission rectal temperature in infants <28 weeks' gestation (difference in means = 1.9 C, P <.001). No significant difference was seen in admission rectal temperature in infants of 28 to 31 weeks' gestation (difference in means = 0.17 C, P =.47). All 5 deaths were in the nonwrap group (vs wrap, P =.04); their mean temperature was 35.1 C versus 36.5 C in survivors (P =.001). CONCLUSIONS: Occlusive wrapping of very low birth weight infants at delivery reduces postnatal temperature fall. This may result in a decreased mortality rate.

Apgar Score↗

The effect of plasma-treated polyethylene fiber on the fracture strength of polymethyl methacrylate.

The effect of a plasma-treated polyethylene fiber on the fracture strength of polymethyl methacrylate was evaluated in this study. Sixteen treated and 16 untreated polymethyl methacrylate bars were tested by use of a three-point compression loading apparatus. Under the conditions of this experiment the treated bars showed a mean fracture strength of 12.56 MPa compared with 9.81 MPa for the untreated samples. In addition to the increased fracture strength, the treated bars also demonstrated resistance to crack propagation. The bars remained in one piece, held together throughout the compression loading by the polyethylene fiber. The clinical implication of these findings is a reduced incidence of fixed provisional restoration failure.

Chemical Phenomena↗

Fracture strengths of provisional restorations reinforced with plasma-treated woven polyethylene fiber.

STATEMENT OF PROBLEM: Fracture strength of interim fixed partial prosthesis is of great concern, especially in long-span restorations or areas of heavy occlusal stress. PURPOSE: Effects of a plasma-treated woven polyethylene fiber (Ribbond) on the fracture strength of polymethyl methacrylate (Coldpac) and a resin-based two-phase curing provisional restorative material (Provipont DC) were evaluated. MATERIAL AND METHODS: A polyvinyl siloxane template was used to fabricate three-unit posterior provisional prostheses on a stainless steel die with two abutments 22 mm apart. The reinforced groups were fabricated by affixing 3 mm wide pieces of fiber treated with methyl methacrylate monomer or polyisocyanate (activator part of Provipont DC) on the occlusal surfaces of abutments. The interim materials were mixed, according to the manufacturers' specifications, and placed in the template. The template was pressed on the die and held secure until complete setting of the material occurred by light curing (Provipont DC) or autopolymerization (PMMA). The specimens were divided into 4 groups of 10 each (A, reinforced Provipont DC; B, unreinforced Provipont DC; C, reinforced PMMA; and D, unreinforced PMMA). A central compressive load force was exerted on the specimen to determine the fracture load of the restorations. RESULTS: The data revealed mean fracture loads of A, 65.59 +/- 11.27 kg; B, 46.59 +/- 14.84 kg; C, 53.46 +/- 7.76 kg; and D, 49.86 +/- 14.44 kg. CONCLUSION: Plasma-treated polyethylene reinforced PMMA restorations showed no significant increase in fracture loads when compared with unreinforced restorations (p > 0.10), whereas reinforced resin-based restorations revealed significantly higher fracture loads (p < 0.01) than the unreinforced resin-based and PMMA provisional restorations.

Bisphenol A-Glycidyl Methacrylate↗

The effect of polyethylene glycol-superoxide dismutase administration on histological damage following spermatic cord torsion.

Oxygen free radicals generated during the ischemic/reperfusion period have been suggested as a possible cause for tissue damage in different organs. In this study we address the question of whether administration of polyethylene glycol-superoxide dismutase, an oxygen free radical scavenger, can alleviate histological damage associated with testicular torsion. The study included 67 Sprague-Dawley rats. In 60 rats the left testicle was rotated 720 degrees clockwise through a scrotal incision. Torsion duration was 3 hours. Five minutes before and 5 minutes after detorsion the testicle color was evaluated and scored. The remaining 7 rats underwent a sham operation. After randomization 8,000 units per kg. polyethylene glycol-superoxide dismutase were injected intraperitoneally in the treated group 1 hour before detorsion. After 14 days histological evaluation was performed on both testicles of 58 rats (2 rats died before the evaluation). No statistically significant difference was demonstrated between the treatment (28 rats) and the control groups (30 rats). Testicular color after detorsion correlated with the histological damage.

Animals↗

[Metal serum levels in 48 patients bearing a chromium-cobalt total hip arthroplasty with a metal-on-polyethylene combination].

PURPOSE OF THE STUDY: Component wear and dissemination of wear debris, particularly with metal-on-metal combinations, is the predominant long-term complication of total hip arthroplasty. The purpose of our work was to search for metal pArticles released when using the metal-on-polyethylene combination by analyzing serum levels of chromium (Cr), cobalt (Co), nickel (Ni), and molybdium (Mo) in patients with a metal-on-polyethylene chromium-cobalt total hip arthroplasty. We compared the observed levels with those observed in a control population and studied changes as a function of signs of loosening. MATERIAL AND METHODS: During a thirty-Month period, 53 patients with degenerative hip disease underwent total hip arthroplasty. The same implant, PVL, being used for all hips. Forty-eight patients were available for analysis at a minimum follow-up of 32 Months. Results of the clinical and radiological examination of the operated hip were recorded. Serum metal levels were assayed by mass spectrometry on total blood samples. Patient activity was determined with the Devane classification and hip function with the Postel-Merle-d'Aubligné score; walking distance was recorded in kilometers. Signs of prosthetic loosening were identified on plain radiograms (AP and lateral views) searching for femoral and/or acetabular lucent lines, cement fracture, granuloma. The control group included 56 patients scheduled for total hip arthroplasty. Non-parametric statistical analysis was used to search for correlations between the clinical, radiological, and biological parameters. RESULTS: At mean 44 Months follow-up, 17% of the patients had a fair or mediocre function score and 37% had radiological signs of femoral component loosening. Serum cobalt increased significantly in the implanted group (serum cobalt >or=0.60 microg/L in 50% of patients) compared with the control group (serum cobalt >or=0.60 microg/L in 9%) (P<0.001, Mann-Whittney test). Increased serum cobalt was highest in patients with radiographic signs of loosening. This significant difference was not found for other metals. Patient activity, hip function, and follow-up were not correlated with serum levels. DISCUSSION: Serum cobalt appears to be a good biological marker of prosthetic function although intra- and inter-individual variations are influenced by assay technique, metal ion solubility, and metal dissemination in the organism. The metal-on-metal combination does not appear to be the only friction couple which increases the serum level of metal ions. Our results do not allow defining a time of latency between onset of radiographic signs and increased serum levels.

Aged↗

[Metal-metal-backed polyethylene cemented hip arthroplasty: mid-term results].

PURPOSE OF THE STUDY: Metal-on-metal bearings in total hip arthroplasty may, in theory, provide an effective answer to osteolysis in active patients. The purpose of this retrospective study was to evaluate the results of a consecutive series of Metasul total hip arthroplasties with a cemented socket. MATERIAL AND METHODS: The series was composed of 28 total hip arthroplasties in 23 patients (13 women and 10 men). The mean age at operation was 44 +/- 8.3 years (range 22-59 years). The initial diagnosis was osteoarthritis (14 hips), osteonecrosis of the femoral head (11 hips) and rheumatoid arthritis (3 hips). Cemented cups with a metal articulation surface molded into the polyethylene were used. The cup was articulated with a 28-mm metallic head. Cemented stems were used in 27 hips, whereas a hydroxyapatite coated stem was implanted in one hip. RESULTS: One hip required revision for deep infection five months postoperatively. One patient (one hip) was lost to follow-up. Twenty-six hips were evaluated at an average 31-month follow-up (range 12-47 months). All hips were rated excellent or very good. Radiographically, seven hips (27%) had a progressive acetabular radiolucent line, including three complete radiolucent lines. The latter always were located at the bone-cement interface. No implant migration was noted. In these cases, the mean socket diameter was lower than for the rest of the cohort (p < 0.001). DISCUSSION AND CONCLUSION: Progression of acetabular radiolucent lines remains of concern in this series of Metasul artificial hips. It is hypothesized that the diminution of polyethylene thickness has led to an increased rigidity of the socket, resulting in a higher rate of constraints at the bone-cement interface. Special attention must be given to these hips.

Adult↗

Ultra-high-modulus polyethylene ribbon as reinforcement for denture polymethyl methacrylate: a short communication.

OBJECTIVE: The aim of this study was to determine the effect of polyethylene fiber ribbon on the transverse strength of denture base polymer. METHODS: One or two layers of ultra-high-modulus or ultra-high-molecular weight polyethylene (UHMP) ribbon were placed into rhombic test specimens of denture base polymer. The specimens were tested with three-point-loading, and the ribbons were positioned on the tension side of the specimen. Fractured test specimens were examined with SEM. RESULTS: The transverse strength of the specimens increased slightly from the incorporation of UHMP fiber ribbons (unreinforced polymer: 91 MPa; with one ribbon layer: 118 MPa; with two ribbon layers: 125 MPa). Adherence of the UHMP fibers to the denture base polymer was poor. SIGNIFICANCE: Improvement in transverse strength of the specimens was modest although the fibers were placed into an ideal position of the specimens. This lack of improvement was due to poor adhesion of the UHMP fibers to the polymer and inadequate impregnation of the fibers with denture base resin.

Analysis of Variance↗

Thermal features of the bovine serum albumin unfolding by polyethylene glycols.

Albumin showed very poor affinity for polyethylene glycol molecular weight (Mw) 1000 (30 M(-1)) and Mw 8000 (400 M(-1)) (PEG 1000 and PEG 8000). Polyethylene glycol of low Mw favours the ionization of the tyrosine (TYR) residues of albumin. Such variation might be a consequence of the change in dielectric constant at the domain of the protein by PEG binding. PEGs of high Mws stabilize the native compact state of human albumin showing negative preferential interaction with the protein. Interaction between PEGs and albumin is thermodynamically unfavourable, and becomes even more unfavourable for denatured proteins whose surface areas are larger than those of native ones leading to a stabilization of the unfolded state, which is manifested as a lowering of the thermal transition temperature. PEG 8000 perturbs the structure of the protein surface, partially modifying the layer of water and the microenvironment of the superficial aromatic residues (tryptophan, TRP and TYR) which is in agreement with the modifications of the UV spectrum of albumin by PEG 8000 and circular dichroism (CD) spectrum at high temperatures.

Acrylamide↗

Comparison of the response of primary human peripheral blood mononuclear phagocytes from different donors to challenge with model polyethylene particles of known size and dose.

The response of primary human peripheral blood mononuclear phagocytes to challenge with polyethylene particles of known size and dose was evaluated. Particles with mean sizes of 0.21, 0.49, 4.3, 7.2, and 88 microm were co-cultured with cells for 24 h prior to the assessment of cell viability and production of the osteolytic mediators IL-1beta, IL-6, TNFalpha, GM-CSF and PGE2. All particle fractions were evaluated at particle volume (microm3) to cell number ratios of 10:1 and 100:1 which were previously identified as being the most biologically active and clinically relevant. The heterogeneity of human individuals was clearly evident both in the profile and the magnitude of the response of the donors evaluated in this study (the response of donor 5 being 2- to 15-fold lower than that of the other donors). Only the sub-micrometre particles stimulated significantly enhanced cytokine secretion at the ratios tested: mean particle sizes of 0.49 and 0.21 microm being the most biologically active. Macrophages stimulated with particles outside this size range produced considerably lower levels of mediator. These results compared favourably with the results of earlier studies, which demonstrated that particles within the phagocytosable size range (0.1-10 microm) were the most biologically active. These results, therefore, confirm earlier findings and suggest that the size and volume of polyethylene particles are critical factors in macrophage activation. Furthermore, they suggest that the heterogeneity of human individuals may be another important factor in determining implant life and could provide the basis for a valuable diagnostic tool to identify those patients most at risk of implant loosening.

Blood Donors↗

Stability of polyethylene oxide in matrix tablets prepared by hot-melt extrusion.

The thermal stability of polyethylene oxide (PEO) in sustained release tablets prepared by hot-melt extrusion was investigated. The weight average molecular weight of the polymer was studied using gel permeation chromatography. The chemical stability of PEO was found to be dependent on both the storage and processing temperature, and the molecular weight of the polymer. Storage of the polymer above its melting point significantly increased polymer degradation, and the degradation process was accelerated as the molecular weight was reduced. The thermal stability of PEO MW = 1,000,000 (PEO 1 M) in sustained release chlropheniramine maleate (CPM) tablets prepared by hot-melt extrusion was found to depend on the processing temperature and screw speed. Lower molecular weight PEO MW = 100,000 (PEO 100 K) was demonstrated to be a suitable processing aid for PEO 1 M. Incorporation of PEO 100 K reduced degradation of PEO 1 M and did not alter the release rate of CPM. Vitamin E, Vitamin E Succinate and Vitamin E TPGS were found to be suitable stabilizers for PEO, however, ascorbic acid was shown to degrade the polymer in solution. Thermal analysis demonstrated that Vitamin E Succinate and Vitamin E TPGS were dispersed at the molecular level in hot-melt extruded tablets. Solubilized Vitamin E Succinate and Vitamin E TPGS suppressed the melting point of the polyethylene oxide. Drug release rates from hot-melt extruded tablets stabilized with antioxidants were found to be dependent on the hydrophilic nature of the antioxidant.

Anti-Allergic Agents↗

Biological reaction to alumina, zirconia, titanium and polyethylene particles implanted onto murine calvaria.

Periprosthetic osteolysis is a serious problem that limits long-term survival of total hip arthroplasty. Ceramics have been introduced as a joint surface material to reduce osteolysis due to wear particles. The aim of this study is to investigate the biological reaction of ceramic particles on murine calvarial bone, in comparison with polyethylene and titanium particles. Sixty CL/BL6 mice were divided into five groups according to the materials implanted onto the murine calvariae: control, Al(2)O(3), ZrO(2), high-density polyethylene (HDP) and Ti6Al4V. One week after the implantation, each calvarial tissue was dissected and the release of proinflammatory mediators (IL-1beta, IL-6, TNF-alpha) and bone resorption were assessed. The particles of HDP and Ti6Al4V induced three and two times larger osteolytic lesions than the control, respectively. The levels of IL-1beta and IL-6 were significantly elevated in the medium subcultured with the calvariae of HDP and Ti6Al4V groups. Any particle type did not increase the levels of TNF-alpha. There were no significant differences observed in the levels of proinflammatory mediators or osteolytic area among Al(2)O(3), ZrO(2) and control groups. The inflammatory response and bone resorption induced by ceramic particles were much smaller than those induced by HDP and Ti6Al4V. These biological features suggest the biocompatibility of ceramics as a joint surface material for artificial joints.

Aluminum↗

Morphology of rod stock and compression-moulded sheets of ultra-high-molecular-weight polyethylene used in orthopaedic implants.

Compression-moulded sheets and extruded rods of ultra-high-molecular-weight polyethylene (UHMWPE) are currently used in the production of joint replacement prostheses. Crystallographic texture present in rods and sheets of UHMWPE was measured using a combination of small-angle X-ray scattering and wide-angle X-ray diffraction. Crystallographic texture can induce anisotropy in macroscopic properties of polymers, such as modulus and yield stress. Both rods and sheets of UHMWPE revealed a low but discernible degree of preferred orientation of polyethylene chains within crystallites. There was a spatial variation in crystallographic orientation in extruded rods. The direction of chain alignment within crystallites located near the outer surface of rods was orthogonal to the radial direction, whereas the chain direction was orthogonal to the axial or extrusion direction in crystallites located near the centreline of extruded rods. Crystallographic texture was spatially uniform in compression-moulded sheets with the chain direction within crystallites aligned orthogonal to the moulding direction. In both cases the induced crystallographic texture can be explained in terms of crystallization from an oriented melt.

Anisotropy↗

Biocompatibility of polyethylene terephthalate (Trevira hochfest) augmentation device in repair of the anterior cruciate ligament.

The biocompatibility of a 3 mm band made of polyethylene terephthalate (Trevira hochfest) has been tested in an experimental study within right knee joints of 60 sheep. After transsecting the anterior cruciate ligament (ACL), two randomized groups were formed. In group I, the ACL was repaired according to the Marshall technique whilst in group II an additional 3 mm polyethylene terephthalate (PET) augmentation band was implanted using the through-the-condyle (TTC) procedure. To assess the biocompatibility of the augmentation device the knee joints of both groups were punctured and the synovial fluids were analyzed before, as well as 2, 6, 16, 26, and 52 weeks after the operation. In addition, the histologic appearance of excised suprapatellar pouches and ipsilateral inguinal and popliteal lymphatic noduli were examined. Comparing both groups no significant differences were found neither before nor after the augmented and non-augmented ACL repair. No pathological increase in the total protein concentration occurred after operation and no significant differences versus the preoperative analysis were found. No synovitis signalling a decrease in the glucose concentration was observed. The cytological examination revealed no increase of the leukocyte cell count results. Within the synovial specimen neither free nor phagocytosed PET wearparticles could be detected. In groups I and II the histological appearance of excised popliteal and inguinal lymphatic noduli showed a normal result. In 25% of the PET augmented ACL repairs, a slight concentration of PET wearparticles and solitary, multinuclear giant foreign body cells could be seen in the histological preparations of suprapatellar pouches.

Animals↗

Porous polyethylene orbital implant in patients with retinoblastoma.

OBJECTIVE: The purpose of the study was to assess integration of porous polyethylene allografts in 37 anophthalmic sockets of retinoblastoma enucleations. DESIGN: A clinical review. PARTICIPANTS: Thirty-four patients (19 female, 15 male) whose age when diagnosed with retinoblastoma ranged from 1 to 72 months participated. Sixteen patients had unilateral retinoblastoma and 18 had bilateral retinoblastoma. INTERVENTION: Enucleation (3 bilateral, 31 unilateral) with implantation of a porous polyethylene (PP) sphere (16-20 mm in diameter) was performed. Of the 37 spheres, 34 were primary implants and 3 were secondary implants. In the eight patients with postimplantation exposure, the PP implant had to be removed. MAIN OUTCOME MEASURES: Data on eight sockets with exposed PP implant were measured. RESULTS: There were no implant extrusions, but conjunctival dehiscence-exposure occurred in eight patients (21.6%). In 3 of 37 sockets, the volume replacement was not good, and in 5 cases, fornices were too shallow to accommodate a well-fitting prosthesis. In all but one socket, the overall cosmesis was graded subjectively from acceptable (grade 2) to excellent (grade 3). CONCLUSIONS: Although the PP implant is a useful and a less-expensive alternative to hydroxyapatite in the porous matrix implant category, if conjunctival exposure takes place, the implant presents a serious management problem because of its nonresponsiveness to medical and surgical treatments.

Biocompatible Materials↗

Influences of preparation conditions on particle size and DNA-loading efficiency for poly(DL-lactic acid-polyethylene glycol) microspheres entrapping free DNA.

Poly-DL-lactic acid-polyethylene glycol (PELA) with different contents and different molecular weight of polyethylene glycol (PEG) was used as a DNA delivery system. DNA-loaded PELA or poly(DL-lactic acid) (PLA) microspheres were prepared by the emulsion evaporation technique, which was based on the water-in-oil-in-water solvent evaporation method. The purpose of the present work was to investigate the factors influencing particle size and DNA loading efficiency for the PELA microspheres containing free DNA. During the preparation process, different conditions were used and the resulting microspheres were characterized by particle size and DNA loading efficiency. Microspheres prepared by PELA with a PEG (molecular weight: 6000 Da) content of 6-10% obtained the highest loading efficiency and smaller particle size among other PELA copolymer and PLA homopolymer. When the solvent of the oil phase was composed of methylene chloride and ethyl acetate (1:1, v/v), the highest loading efficiency and smaller particle size were also obtained for the PELA microspheres. The presence of the surfactant in oil phase influenced both the particle size and loading efficiency. Increasing the concentration of polymer in oil phase resulted in an increase of particle size and loading efficiency for DNA-loaded PELA microspheres. The addition of a hydrophilic polymer into the internal water phase ameliorated the DNA loading efficiency and reduced the particle size. Significant influences of DNA molecular weight and structure on the particle size and loading efficiency were observed. The volume and concentration of the external water phase also influenced the particle size and loading efficiency.

DNA↗

Optimization of preparative conditions for poly-DL-lactide- polyethylene glycol microspheres with entrapped Vibrio cholera antigens.

Poly-dl-lactide-polyethylene glycol (PELA) with different contents of polyethylene glycol(PEG) were synthesized and the PEG content was estimated according to the integral height of hydrogen shown in 1H-NMR. PELA microspheres containing V. cholera antigen, outer membrane protein (OMP) were prepared by a water-in-oil-in-water (W/O/W) based on solvent evaporation procedure. Antigen microspheres with smooth surface, suitable size for oral administration (0.5-5 microm), high loading efficiency (about 60%) and low level of residual solvent (lower than 20ppm) were obtained. Microspheres prepared from PELA with PEG content of about 10% achieved the highest loading efficiency among PELA copolymers and poly-dl-lactide (PLA) homopolymer, which suggested that microspheres size, morphology and the precipitation rate of polymer showed considerable relations with OMP loading efficiency. The regulation of the solvent components of the oil phase contributes to a stable emulsion W/O, and it is concluded that the stable emulsion W/O plays a significant role in improving the protein loading efficiency of obtained microspheres. The addition of stabilizer, such as gelatin and polyvinyl alcohol, into the internal water phase before emulsification produced no significant difference in OMP entrapment and microspheres size. A higher OMP loading efficiency was achieved by adding NaCl or adjusting the pH at the iso-electric point of OMP in the external water phase. It was indicated in vitro that PELA microspheres with smaller size showed larger extent of initial release and higher release rate, whereas microspheres with the diameter of 2.17 microm showed no apparent burst effect.

Antigens, Bacterial↗

Evaluation of a new povidone-iodine-impregnated polyethylene oxide gel occlusive dressing.

Forty-five surgical wounds were closed by suture technic and then treated with either a polyethylene oxide gel (POG) dressing or a povidone-iodine-impregnated polyethylene oxide gel (PVPI-POG) dressing. In the control group with the POG dressing alone, three wound infections, representing 25% of those patients, were encountered. In the PVPI-POG dressing group no wound infections were encountered. Wound healing, in terms of reduced inflammation and faster epidermal approximation, appeared better in the PVPI-POG dressing group.

Gels↗