Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pliability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Comparison of two heat-pressed all-ceramic dental materials.

OBJECTIVES: The processing route for two heat-pressed all-ceramic materials (Empress and OPC) is virtually identical. The purpose of this study was to determine the mechanical properties of both materials and determine if significant differences exist between them. METHODS: X-ray powder diffraction of the ceramics before and after processing was carried out to identify the crystal phases present. The mechanical properties of both materials were tested. Specimens were tested for hardness, fracture toughness (indentation method) and flexural strength (biaxial method). The results were statistically evaluated and tested for differences using a Mann-Whitney test. Secondary electron imaging of both materials was carried out before and after processing. RESULTS: X-ray powder diffraction revealed that OPC changes as a result of heat-pressing from being a complex mixture of crystalline oxides to a glass-ceramic. In contrast Empress is a glass-ceramic before and after processing. X-ray diffraction identified leucite as the main crystalline phase in both ceramics. The biaxial flexural strength of OPC was 153.6 (17.8) MPa and for Empress was 134.4 (11.5) MPa. The hardness of OPC was 7.28 (0.62) GPa and for Empress was 6.94 (0.79) GPa. Indentation fracture toughness of OPC was 1.36 (0.29) MPam0.5 and for Empress was 1.33 (0.08) MPam0.5. Secondary electron images show Empress to be the same before and after processing while OPC is clearly very different. Empress also appears to have a higher glass content compared with OPC. SIGNIFICANCE: The results of X-ray diffraction show that Empress is pre-cerammed whilst OPC is not. Statistical analysis revealed that no significant difference exists between the two materials for any of the mechanical properties tested at a 95% (p < 0.05) confidence level. It was concluded that no difference exists between the two materials on completion of processing.

Aluminum Silicates↗

Flexural strength optimisation of a leucite reinforced glass ceramic.

OBJECTIVES: The aims of the study were to process a ceramic material with a fine leucite particle size using hot pressing techniques, to increase the flexural strength, reliability and ease of use. METHODS: A starting glass composition of wt%; 64.2% SiO(2), 16.1% Al(2)O(3), 10.9% K(2)O, 4.3% Na(2)O, 1.7% CaO, 0.5% LiO and 0.4% TiO(2) was used to produce a leucite reinforced ceramic material. Twenty-one porcelain discs were produced by sintering the ceramic frit (group 1) and sixty-three discs by heat pressing the frit (groups 2, 3 and 4). Twenty-one Empress 1 ceramic discs were also heat pressed (group 5). Disc specimens were tested using the biaxial flexure test at a crosshead speed of 0.15mm/min and the data analysed using the Scheffé F multiple comparison test and Weibull statistics. Specimens were characterised using X-ray diffraction (XRD), secondary electron imaging and energy dispersive X-ray analysis where applicable. RESULTS: The heat pressed groups (2, 3 and 4) had higher mean biaxial flexural strengths and characteristic strength values than groups 1 and 5 (p<0.05). XRD revealed the presence of tetragonal leucite in all test groups. Fine leucite crystals, tabular platelets and minimal matrix microcracking were found in the microstructure of test groups (1-4) with a more uniform leucite distribution in the heat pressed specimen groups (2, 3 and 4), which were associated with a significant increase in the biaxial flexural strength and reliability. SIGNIFICANCE: Optimisation of the microstructure by producing a fine microstructure and controlling the distribution via the correct pressing parameters may be extremely advantageous in these systems.

Aluminum Silicates↗

A comparison of the mechanical properties of a gallium-based alloy with a spherical high-copper amalgam.

OBJECTIVES: The aim of the present study was to investigate how the mechanical properties of a palladium free gallium-based alloy (Galloy) compare with a leading spherical high-copper amalgam (Tytin). METHODS: Cylindrical specimens were mechanically condensed, according to the ISO 1559:1986 standard, to measure compressive strength, Vickers hardness, static creep and dimensional change on setting. Disc and beam shaped specimens were manually prepared to assess the diametral tensile and flexural strengths of the investigated alloys. RESULTS: The mean hardness, 1h compressive fracture strength, 24 h diametral tensile and 24h flexural strengths of Galloy were significantly lower (P<0.001) than Tytin. No significant differences in modulus of elasticity, creep, dimensional change on setting, 24 and 168 h compressive fracture strength for the two alloys were identified. SIGNIFICANCE: The significant reduction in the 1 h mean compressive fracture strength and hardness identified for Galloy compared with Tytin possibly indicate a slower setting reaction in the gallium-based alloy. Manual condensation of the gallium-based alloy produced specimens with inferior mechanical properties possibly due to the increased likelihood of introducing voids within the test specimens. Previous reports indicating poor corrosion resistance and moisture sensitivity of gallium-based alloys highlight the need for further research to investigate the effect of the oral environment on the gallium-based alloy.

Compressive Strength↗

Primary cyclization in the polymerization of bis-GMA and TEGDMA: a modeling approach to understanding the cure of dental resins.

An optimal dental restorative polymeric material would have a homogeneous cross-linking density giving it consistent mechanical strength throughout the material. When multifunctional monomers are polymerized, a pendant double bond can react intramolecularly with the radical on its propagating chain to form a loop, which results in a primary cyclization reaction. Primary cyclization does not contribute to overall network structure, causes microgel formation, and leads to heterogeneity in the polymer. Knowledge of how cure conditions control the degree of primary cyclization and cross-linking in the polymer is important in developing better dental materials. To gain more understanding about the evolving polymer network, the photopolymerization of a typical dental resin (75/25 wt% bis-GMA/TEGDMA) is modeled using a first principals approach. The overall polymerization rate behavior of 75/25 wt% bis-GMA/TEGDMA is predicted using experimentally obtained propagation and termination kinetic rate constants. The effect of chain stiffness and light intensity on the polymerization kinetics is also explored. Furthermore, the model predicts the extent of cross-linking and primary cyclization in the growing polymer network. At 45% conversion, the fraction of bis-GMA and TEGDMA pendant double bonds created that have cycled is 11 and 33%, respectively. The model shows that using a stiff monomer, like bis-GMA, in dental resins diminishes the extent of cyclization and increases the cross-linking density of the polymer. Therefore, better mechanical properties are obtained than if more flexible monomers were used.

Algorithms↗

Flexural strength of Cerec 2 machined and jointed InCeram-Alumina and InCeram-Zirconia bars.

OBJECTIVE: The flexural strength of Cerec 2 InCeram-Alumina and InCeram-Zirconia bars is evaluated. The focus of the in vitro study is to identify a jointing procedure for InCeram which may be used for producing full-ceramic fixed-partial-denture frameworks. METHODS: Six groups (n=15) of machined and jointed InCeram-Alumina (T1-T5) and InCeram-Zirconia (T6) bars (3x4x13mm(3)), respectively, were examined using a 3-point-bending test. InCeram-Alumina joint-free controls were: machined (C1), slip cast (C2, C3) and cut from the block (C4) bars. Machined joint-free InCeram-Zirconia bars were used as controls (C5). InCeram-Alumina slip was used for jointing T1-T5 and InCeram-Zirconia slip for bars T6. Bars were jointed in groups T1 and T2 using butt joint (S1), in T3 and T4 oblique (S2, S3) and in T5 and T6 rounded (S4) joint shapes. RESULTS: Two-way analysis of variance showed significant differences between materials (p<0.001) and jointing shapes (p<0.001). The rounded (S4) shape showed the highest flexural strength of 434 (65) MPa of InCeram-Alumina (T5) and 475 (54) MPa of InCeram-Zirconia (T6) bars, respectively but machined/joint-free InCeram-Alumina (511 (59) MPa, C1) and machined/joint-free InCeram-Zirconia (624 (58) MPa, C5) were significantly (p<0.01/p<0.001) stronger. No significant differences (p>0.05) were found between machined/jointed InCeram-Zirconia (475 (54) MPa, T6), joint-free InCeram-Alumina slip cast (498 (125) MPa, C2) and joint-free InCeram-Alumina machined bars (511 (59) MPa, C1). SIGNIFICANCE: Compared to conventional slip cast InCeram-Alumina the flexural strength of machined/jointed InCeram-Zirconia appears to be adequate for fixed-partial-denture frameworks.

Aluminum Oxide↗

Nondestructive estimation of the strength of dental ceramic materials.

OBJECTIVES: The aim of this study was to prove a nondestructive method to evaluate the strength of dental ceramic materials with respect to its potentiality and limitations. METHODS: The Young's moduli of 13 dental ceramic materials were determined by the resonance frequency method. Additionally, the flexural strengths of eight of these materials were evaluated by the four-point bending test. Strength values for the other five ceramic materials were taken from the literature. The Young's moduli were correlated with the strength values by Hook's law, respectively. RESULTS: Young's modulus for ceramics can be determined using a resonance frequency method. Fracture strain values of the ceramic materials tested (with the exception of Empress 2) have fracture strain values between 0.08 and 0.15%. A mean strain can be calculated (0.11%) and used with the value of Young's modulus to estimate fracture strength of ceramics. For the materials evaluated, predicted strength was within 39% of the measured values. SIGNIFICANCE: A non-destructive method to estimate strength of dental ceramic materials is possible, even though the accuracy of the predicted values is not very high. Nevertheless, the method permits new materials proposed for dental ceramic restorations to be screened for probable clinical success. Expensive and time-consuming testing would only need to be done on those materials which pass this initial criterion.

Algorithms↗

Current luting cements: marginal gap formation of composite inlay and their mechanical properties.

OBJECTIVE: The aims of this investigation were to investigate the effect of thermocycling on the marginal gap formation of composite inlays using three types of luting cements (Compolute, PermaCem, Fuji Plus, Panavia 21: as a control) and on mechanical properties of four luting cements. METHODS: The maximum marginal gap in the dentin cavity of each of ten resin inlay specimens in each group, was measured by a microscope before and after 10,000 thermocycles. The dimensional change, shear bond strength to dentin, and material and conditions for flexural strength and modulus testing were examined. RESULTS: Compolute and Panavia 21 showed marginal gaps of approximately 10 microm before thermocycling. In contrast, the gap widths after thermocycling was significantly wider. Although the gap widths of PermaCem and Fuji Plus were approximately 60-110 microm prior to thermocycling, they were significantly smaller in width after thermocycling. Statistical differences in the shear bond strength to dentin were not observed before or after thermocycling for all materials. The flexural strength and modulus were significantly increased after thermocycling compared with three products and with all four products, respectively. SIGNIFICANCE: The mechanical properties of all four luting cements were closely related to their marginal gap formations and these mechanical factors have important roles in determining their marginal gap formations.

Chi-Square Distribution↗

Water sorption and mechanical behaviour of cosmetic direct restorative materials in artificial saliva.

OBJECTIVES: To evaluate the water sorption and mechanical behaviour of a compomer in comparison with those of its nominal forerunners, a filled resin restorative material and a conventional glass ionomer cement. METHOD: Compomer (Dyract AP) (D-AP), filled resin (SureFil) (SF), and glass ionomer (ChemFlex) (CF) (all Dentsply, Addlestone, UK) restorative materials were tested. Forty bar specimens (26x1.5x1.0mm(3)) of each material were prepared according to the manufacturer's instructions and randomly distributed into eight groups: dry air (22% RH), saturated water vapour (WV) (100% RH), and five in artificial saliva (AS) at pH6, all at 37 degrees C, as well as untreated control (UC) (23 degrees C, 50% RH). Water sorption was assessed gravimetrically; flexural strength and elastic modulus were determined in three-point bend. The control group was tested at 24h; AS groups were separately tested after 0.5, 1, 3, 6 and 9 months; the other two at 9 months. RESULTS: Mass gain for SF, D-AP and CF in AS was up to 0.17%, 1.2% and 7.0%, respectively. CF showed a marked decrease of strength in AS compared with other groups, followed by a gradual slight rise to a peak at 3 months. Unlike SF and CF, whose flexural strength remained relatively stable, that of D-AP showed a sharp decline from the 1 month peak (P=6x10(-7)) after 6 months in AS. D-AP also showed a slight decline in flexural modulus from a peak, that of SF was quite stable, while CF showed no peak. The values of flexural strength for both CF and D-AP at 9 months were significantly lower in AS than WV, but SF showed no such difference. SIGNIFICANCE: Materials intended for service in the mouth must be stored in a realistic medium if the results of testing are to be interpretable. Dyract AP, a compomer, does not seem suitable for application in stress bearing areas as is currently recommended by its manufacturer. The rapid decline in flexural strength after 1 month of exposure to AS and its progressive fall in flexural modulus suggest a progressive deterioration of the material and this necessitates re-examination of the chemistry of compomers, if the behaviour is typical of the class.

Air↗

Effect of water exposure on the fracture toughness and flexure strength of a dental glass.

OBJECTIVES: The low fusing dental glass (Duceram LFC) has been advertised as presenting a superior chemical resistance and augmented strength after 16h exposure to water or 4% acetic acid. The purpose of this study was to evaluate the effect of prolonged exposure to water on two mechanical properties (fracture toughness and flexure strength) of LFC. METHODS: Disks and bars were mirror polished and annealed prior to aging in: (1) air (control), (2) water for 24h at 80 degrees C and (3) water for 8 weeks at 80 degrees C. Fracture toughness (K(Ic)) was determined by indentation fracture (IF) and indentation strength (IS) using a 19.6N Vickers indentation load. Flexure strength values were obtained from three-point bending at 0.1mm/min. Statistical analysis was performed using the Weibull distribution, Tukey and Bartlett tests (P<0.05). RESULTS: Both techniques (IS and IF) showed a significant improvement in the K of Duceram LFC after 8 weeks in water (0.88 and 1.14MPa m(0.5)) as opposed to the 24-h values both in water and air (0.77-0.78MPa m(0.5)). However, for flexure strength the Weibull characteristic (S(0)) and the m parameter did not change significantly with water storage (S(0)=90-100MPa, Weibull m =7-8). SIGNIFICANCE: The increase in toughness of Duceram LFC after aging in water is an interesting and favorable observation for a restorative material exposed to the oral environment. Nevertheless, in comparison with other contemporary ceramics, the toughness of this LFC remains in the range of soda-lime-glass or classic feldspar porcelains.

Acetic Acid↗

Fracture toughness of dental ceramics: comparison of bending and indentation method.

OBJECTIVES: The aim of this study was to compare two fracture toughness methods, the bending method on notched specimens as reference and the indentation method as comparison. Potentialities and limitations of the indentation method were analyzed. METHODS: Fracture toughness values were determined for seven dental ceramic materials on 'single-edge-v-notched beams' (bending method) as our standard method. Additionally indentation tests were done on the identical samples from the bending tests. The results were determined before and after annealing of the samples. With the reference fracture toughness results from the bending tests, the prefactor in the indentation test formula was individually adapted for each tested material. RESULTS: The individual prefactors varied between 0.0122 and 0.0253 for the specimens before annealing and between 0.0150 and 0.0267 for the annealed specimens. Subsequently the differences between the K Ic-values calculated by the ISO draft (TC 206) direction and calculated by the modified formulae with the material specific prefactors were up to 48% for unannealed and up to 33% for annealed specimens, respectively. SIGNIFICANCE: The indentation method is not an adequate tool to exactly determine the fracture toughness of an unknown ceramic material. This method can only be used for a first rough K Ic estimation.

Algorithms↗

Mechanical properties of visible light-cured resins reinforced with hydroxyapatite for dental restoration.

OBJECTIVES: The purpose of this study was to measure and analyze the mechanical properties of several composite materials designed for dental restoration. METHODS: The materials were composed of a visible light-curing monomer mixture (either Bis-GMA+TEGDMA or Bis-GMA+HEMA) as a matrix and hydroxyapatite (either microscopic or nanoscopic particles) as a reinforcing filler. The surface of the hydroxyapatite particles was modified by using a coupling agent (citric, malic, acrylic or methacrylic acid). Five specimens of 14 different composites were prepared for each mechanical test: flexural strength, Young's modulus and Vickers hardness. Mean values and standard deviations were calculated, and ANOVA and Student Newman Keuls multiple comparison tests were applied (P < 0.05). RESULTS: The addition of 50-60 wt% of hydroxyapatite particles to the unfilled monomer mixtures led to the increase of both Young's modulus and surface hardness of the material, while the flexural strength decreased. In general, when microscopic instead of nanoscopic hydroxyapatite was used as a reinforcing filler, mechanical properties were favored. The mechanical properties were also improved by adding citric, acrylic or methacrylic acid as a coupling agent. CONCLUSIONS: An adequate surface modification of the hydroxyapatite particles conferred enhanced mechanical properties to the final dental composite. Microscopic-hydroxyapatite particles are preferred to nanoscopic ones.

Acrylates↗

Dynamic and static moduli of elasticity of resin-based materials.

OBJECTIVES: The purpose of this study was to assess and compare the elastic moduli of 34 resin-based materials using a dynamic and a static method. The effect of water storage was also studied up to 6 months. METHODS: Five samples of each material were prepared according to ISO-4049. The dynamic moduli were first determined non-destructively from the fundamental period of the vibrating specimen, then the static moduli were determined by a three-point bending test. The percentages of fillers by weight were determined by ashing in air at 900 degrees C. RESULTS: Low values were obtained with flowable composites as well as with two packable resin composites. Correlations were found between the static and the dynamic modulus of elasticity (r = 0.94; p = 0.0001) as well as between the weight percentage of fillers and the moduli of elasticity (r = 0.82; p < 0.05 for static modulus and r = 0.90; p < 0.05 for the dynamic modulus) both at 24h. Water storage significantly affected both static and dynamic moduli of elasticity (ANOVA two factors; p < 0.05). SIGNIFICANCE: The low moduli of the flowable composites do not allow their use in posterior cavities under high stress. However, this does not exclude their use for minimally-invasive Class I cavities when the opposing tooth is stabilized to a large amount on the natural enamel. The Grindosonic method is very useful and simple for determining the dynamic moduli although it gives higher values than the static one. The elastic modulus evolution of resin-based materials after water storage is unpredictable since different patterns were observed as a function of time.

Analysis of Variance↗

Effect of novel filler particles on the mechanical and wear properties of dental composites.

OBJECTIVES: The purpose of this study was to investigate the method of producing pre-polymerized fused-fiber filler modified composite (PP-FFMC) particles and the effectiveness of incorporating these novel filler particles into dental composites. METHODS: Fused-fiber filler (FFF) blocks were impregnated with composite by two different methods. Three-point flexure tests were utilized to determine which was more effective. In order to assess the effect of the addition of PP-FFMC particles, two Bis-GMA/TEGDMA based conventional composite compositions were utilized as baselines, to which the novel particles were added. Mechanical and wear tests were performed to determine the fracture toughness, biaxial flexure strength, and in vitro wear of the materials. RESULTS: Mechanical testing showed that the addition of PP-FFMC particles decreased the strength and toughness of the conventional composites. Wear tests indicated that addition of the same particles improved the wear behavior of the conventional composites. SEM analysis of the fracture surfaces indicated that the PP-FFMC particles were incorporated without creating porosity, and that fracture was transgranular through the reinforcing particles. Microscopic flaws observed in the novel particles are the likely explanation for the observed strength and toughness values. SIGNIFICANCE: The results indicate that PP-FFMC particles have the potential to improve the wear properties of dental composites, however, they adversely affect the fracture behavior. Existing processing techniques for these particles, which introduce imperfections, limit their current usefulness.

Aluminum Oxide↗

Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures.

OBJECTIVE: The purpose of this study was to investigate the mechanical properties of superelastic nickel-titanium orthodontic wires under controlled stress and temperature. METHODS: Three different superelastic nickel-titanium wires were examined using differential scanning calorimetry (DSC), three-point bending test and micro X-ray diffraction (micro-XRD). The three-point bending test was carried out at constant temperature (23, 37 and 60 degrees C) and stepwise temperature changes (37-60 degrees C and to 37 degrees C) (37-2 degrees C and to 37 degrees C). Five specimens of each wire were tested. Micro-XRD spectra were measured at the tension side of the wire when the temperature changed from 37 to 60 degrees C or 2 degrees C. RESULTS: The load during the stepwise temperature changes (37-2 degrees C and to 37 degrees C) was consistent with that measured at a corresponding constant temperature. The micro XRD spectrum clearly showed that the austenite phase was transformed to martensite phase when the temperature is decreased from 37 to 2 degrees C. In a stepwise temperature change (37-60 degrees C and to 37 degrees C), the load became higher than the original load at each corresponding constant temperature. However, there was no detectable change in the micro-XRD spectrum when the temperature was increased from 37 to 60 degrees C. SIGNIFICANCE: The superelastic nickel-titanium wires exhibited complicated and unexpected mechanical properties under stepwise temperature change. This study shows the possibility of qualitative analysis using micro-XRD to understand mechanical properties of these nickel-titanium wires.

Calorimetry, Differential Scanning↗

Strength and fracture toughness of MgO-modified glass infiltrated alumina for CAD/CAM.

OBJECTIVE: This study was conducted to investigate the effect of MgO additive to Al2O3 on the flexural strength, fracture toughness of glass infiltrated alumina for CAD/CAM application. METHODS: Alumina blanks with additive of 0.5 wt% MgO were prepared via isostatic pressing and sintering at 1400 degrees C for 2h, and then alumina-glass composites were fabricated by infiltrating the molten glass into the partially sintered alumina compact. Flexural strength and fracture toughness were determined using three point bending methods and a single edge notched beam method. The mechanism of crack propagation was observed under a field emission scanning electron microscope. RESULTS: The three-point flexural strength and fracture toughness of partially sintered alumina and alumina-glass composite were 210 MPa, 1.86 MPam(1/2), and 432.2 MPa, 5.12 MPam(1/2), respectively, and they were free of shrinkage during the processing of glass infiltration. The field emission SEM micrograph indicated that indentation caused a non-planar crack propagation including crack deflection and crack bowing. SIGNIFICANCE: MgO was used as an additive to alumina to improve the strength and fracture toughness of partially sintered alumina and alumina-glass composite. The high strength and toughness are related to toughening by the distribution of alumina with uniform particle sizes, crack bowing, crack deflection and the beneficial wetting properties of the particle surface.

Aluminum Oxide↗

The effects of luting resin bond to dentin on the strength of dentin supported by indirect resin composite.

OBJECTIVES: The purpose of this study was to evaluate the effects of thickness and adhesion of three resin cements on the fracture resistance of indirect resin composite bonded to dentin. METHODS: A disk of resin composite used for indirect restorations was bonded to a disk of bovine dentin using three kinds of resin cements with various bonding procedures. The bonding procedures were planned into five groups according to the materials and methods, and subsequently subdivided into three groups according to the cement thickness (50, 150 and 500 microm) in each bonding procedure. The thickness of the resin cement and that of the resin composite disk was changed simultaneously while maintaining a total specimen thickness of 2 mm. The prepared specimens were then stored in water at 37 degrees C for 24h at which time they were trimmed to a size of 2 x 2 x 8 mm. The trimmed specimens were subjected to a three point bending test and the fracture load determined. The tensile bond strength of each bonding procedure was measured and the correlation to the fracture load evaluated. RESULTS: The fracture load was affected by the dentin bond strength. The effect of cement film thickness on the fracture load was negligible. SIGNIFICANCE: When an indirect restoration is adhered to the tooth substrate, the adhesion of the luting cement to the tooth substrate is very important for the fracture resistance of indirect resin composite.

Acid Etching, Dental↗

Development of a new photocurable composite resin with reduced curing shrinkage.

OBJECTIVE: This study was conducted to evaluate the potential of a novel trifunctional methacrylate as a component of a photocurable composite resin with reduced curing shrinkage. METHODS: Tris[4-(2'-hydroxy-3'-methacryloyloxypropoxy)phenyl]methane (TTEMA) was synthesized by reacting triphenylolmethane triglycidyl ether (TTE) with methacrylic acid in the presence of 4-(dimethylamino)pyridine. Photopolymerization reactivity and volumetric shrinkage of unfilled resins based on TTEMA were investigated by Fourier transform infrared spectroscopy and density measurements, respectively, and the results were compared with those for conventional dental monomers. A three-point bending test of the TTEMA-containing composite resin was carried out. RESULTS: TTEMA was easily prepared in a good yield of 89%. Unfilled resins of TTEMA and bis-GMA, each containing 40% TEGDMA, showed similar photopolymerization reactivity. TTEMA exhibited a very low photopolymerization shrinkage of 2.09%, and 3:2 TTEMA-TEGDMA unfilled resin revealed 10% lower shrinkage than a conventional bis-GMA system containing the same amount of TEGDMA. The flexural strength of a light-activated composite resin formulated with TTEMA is comparable to that of a bis-GMA composite resin under the same conditions. SIGNIFICANCE: TTEMA is promising for application as a photocurable dental monomer due to ease of synthesis, good polymerization reactivity, and relatively low curing shrinkage.

4-Aminopyridine↗

Effect of adhesive layer properties on stress distribution in composite restorations--a 3D finite element analysis.

OBJECTIVES: Teeth, adhesively restored with resin-based materials, were modeled by 3D-finite elements analysis that showed a premature failure during polymerization shrinkage and occlusal loading. METHODS: Simulation of Class II MOD composite restorations with a resin bonding system revealed a complex biomechanical behavior arising from the simultaneous effects of polymerization shrinkage, composite stiffness and adhesive interface strain. Due to a polymerization contraction, shrinkage stress increases with the rigidity of the composites utilised in the restoration, while the cusp movements under occlusal loading are inversely proportional to the rigidity of the composites. The adhesive layer's strain also plays a relevant role in the attenuation of the polymerization and occlusal loading stresses. RESULTS: The choice of an appropriately compliant adhesive layer, able to partially absorb the composite deformation, limits the intensity of the stress transmitted to the remaining natural tooth tissues. For adhesives and composites of different rigidities, FEM analysis allows the determination of the optimal adhesive layer thickness leading to maximum stress release while preserving the interface integrity. Application of a thin layer of a more flexible adhesive (lower elastic modulus) leads to the same stress relief as thick layers of less flexible adhesive (higher elastic modulus).

Composite Resins↗