Stepped-care, community clinic interventions to promote mammography use among low-income rural African American women.

Few studies have investigated community clinic-based interventions to promote mammography screening among rural African American women. This study randomized older low-income rural African American women who had not participated in screening in the previous 2 years to a theory-based, personalized letter or usual care; no group differences in mammography rate were evident at 6-month follow-up. Women who had not obtained a mammogram were then randomized to a tailored call delivered by community health care workers or a tailored letter. There were no group differences in mammography rates after the second 6-month follow-up. However, among women who had never had a mammogram, the tailored call was more effective in promoting mammography use. Tailored counseling may be an effective screening promotion strategy for hard-to-reach rural African American women with no history of screening. Further research into this strategy may facilitate efforts to reduce health disparities in underserved low-income rural African American populations.

Black or African American↗

Ethnic differences in decisional balance and stages of mammography adoption.

Behavioral theories developed through research with mainstream, English-speaking populations have been applied to ethnically diverse and underserved communities in the effort to eliminate disparities in early breast cancer detection. This study tests the validity of the transtheoretical model (TTM) decisional balance measure and the application of the TTM stages of change in a multiethnic, multilingual sample. A random sample of 1,463 Filipino, Latino, African American, Chinese, and White women aged 40 to 74 completed a phone survey of mammography beliefs and practices. Consistent with the TTM and independent of ethnicity, decisional balance was associated with mammography stage in all five ethnic groups when controlling for socioeconomic and other factors. In addition, having private insurance and a regular physician and being a long-time resident in the United States were positively associated with mammography maintenance. The application of the TTM for mammography is supported in a multiethnic and multilingual sample.

Adult↗

A health priorities model: application to mammography screening.

This study describes and empirically tests a health priorities model. This model predicts underuse of regular mammography screening among adult women within the larger health context in which such decisions are made. The model incorporates women's comparative illness threats, comparative importance of health behaviors, and demographic variables. A telephone survey was conducted with a sample of women (N = 887) older than 50, in 40 rural communities in the state of Washington. Logistic regression analyses showed that women who perceived themselves at low risk for getting breast cancer and/or who perceived another disease (i.e. heart attack) as an equal or greater threat than breast cancer were less likely to be regular screeners of mammography. In addition, women who perceived other health behaviors as more important than regular mammography screening were less likely to be regular screeners than those women who perceived regular mammography screening as more important. Current or anticipated health problems were not related to screening behavior. The results are discussed in light of the practical, theoretical, and empirical implications.

Aged↗

The effect of breast cancer screening messages on knowledge, attitudes, perceived risk, and mammography screening of African American women in the rural South.

PURPOSE/OBJECTIVES: To determine the effect of three types of breast cancer screening messages (positive/upbeat, neutral/cognitive, and negative/fear) on knowledge, attitudes, perceived risk for breast cancer, and mammography screening of African American women. DESIGN: Repeated measures intervention. SETTING: Three rural counties in the South. SAMPLE: 450 African American women aged 45-65 who had not received a mammogram in the past 12 months. METHODS: Following completion of pretest knowledge and attitude surveys, the women participated in a 60-minute breast health intervention session that included watching one of three videos with varied affective tones (positive/upbeat, neutral/cognitive, negative/fear). Data on knowledge, attitudes, perceived risk for breast cancer, and mammography screening were collected before, after, and 12 months following the intervention. MAIN RESEARCH VARIABLES: Knowledge, attitudes, perceived risk for breast cancer, and mammography screening. FINDINGS: No significant difference was found among video groups on mammography screening and knowledge of and attitudes about breast cancer over the three measurement periods. CONCLUSIONS: The affective tone of the educational videos did not make a difference in mammogram screening, attitudes, and knowledge of breast cancer screening. More women received a mammogram 12 months postintervention than prior to the intervention; however, the influence of the intervention on this outcome is uncertain. IMPLICATIONS FOR NURSING: Nurses and health communication experts should design interventions that foster positive attitudes, increase knowledge about breast cancer screening, and stimulate women to participate in breast cancer screening as outlined by the American Cancer Society. These interventions need to be done in the context of the cultural norms and the education levels of the target population.

Black or African American↗

Matching health messages to information-processing styles: need for cognition and mammography utilization.

The use of tailored health communications has become a favored technique for persuading individuals to engage in health behaviors, such as screening mammography. This experiment examined the impact of tailoring persuasive health communications to one aspect of individuals' information-processing styles, that of the need for cognition (NFC), the enjoyment of thinking deeply about issues. To determine whether messages matched to an individual's NFC are more influential than mismatched messages, 602 women who called the Cancer Information Service (CIS) of the National Cancer Institute were asked to participate in an experiment at the end of their service call. They were assigned randomly to receive 1 of 2 phone messages promoting mammography use and a similarly tailored pamphlet 1 month later. Messages matched to an individual's NFC were better at motivating mammography 6 months later among high-NFC women. After controlling for prior mammography utilization, age, worry, intentions, perceived norms, suggestions to get a mammogram, and marital status, the interaction between participant NFC and message type also approached statistical significance. The differential influence of these brief, tailored communications diminished after 12 months, however.

Adult↗

A phantom for the measurement of contrast detail performance in film-screen mammography.

A National Breast Cancer Screening Programme, based on X-ray mammography, has been introduced in the UK. The success of this screening programme is dependent on the production of high quality radiographs. There are various methods of assessing imaging performance in mammography, but contrast detail detectability measurements have an advantage in that the observation of radiographs is taken into consideration. The design and construction of a contrast detail phantom for the assessment of image quality in mammography is described. This phantom can be used to assess the imaging performance of mammographic film-screen combinations. The results of some measurements to verify the accuracy of the contrast predictions are presented together with some initial results of an investigation into the contrast detail performance of film-screen combinations used in mammography.

Breast Neoplasms↗

Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study.

The comparative performance of mammographic X-ray systems that use different anode/filter combinations has been assessed for screen-film and digital imaging. Monte Carlo techniques have been used to calculate average glandular dose as well as contrast and signal-to-noise ratio for imaging two test details. Five anode/filter combinations have been studied to establish the potential for dose saving or image quality improvement. For screen-film mammography, it was found that little benefit is gained by changing from a standard 28 kV molybdenum/molybdenum spectrum for breasts up to 6 cm thick. For thicker breasts, where the tube potential for the standard technique might be increased, 20% improvement in contrast can be achieved without dose penalty using molybdenum/rhodium or rhodium/rhodium spectra, whereas dose savings of more than 50% can be attained whilst maintaining contrast using tungsten/rhodium or rhodium/aluminium spectra. In digital mammography, a molybdenum/molybdenum spectrum delivers the lowest dose for a 2 cm breast, but gives the highest dose for thicker breasts. Tungsten/rhodium or rhodium/aluminium spectra provide the lowest doses at greater thicknesses. It is concluded that for screen-film mammography, molybdenum/molybdenum is the spectrum of choice for all but the thickest or most glandular breasts. In digital mammography, an alternative spectrum is preferable for breasts thicker than 2 cm.

Aluminum↗

Image quality and dose in film-screen magnification mammography.

Extended exposure times in magnification mammography are a result of the reduced X-ray tube currents required for a small focal spot. The consequences of this are the potential for reduced image quality through motion blur during exposure as well as the onset of film reciprocity law failure. Previous investigators have suggested increasing the X-ray tube potential as a practical mechanism for reducing exposure times in magnification mammography and have demonstrated negligible image quality degradation at least up to 32 kVp. This paper describes a film-screen magnification mammography study that expands upon this previous work to investigate the magnitude of the reduction of breast mean glandular dose and exposure time and the changes in subjective image quality (visibility of low contrast details in an RMI 152 phantom) with increases in tube potential between 28 kVp and 35 kVp. Measures of changes in the radiographic contrast and in the scatter-to-primary ratio (SPR) in magnification geometry as a function of tube potential were also obtained. Evidence for reciprocity law failure was also assessed. For a constant film optical density, increasing the X-ray tube potential from 28 kVp to 35 kVp reduced the mean glandular dose from 3.9 mGy to 2.7 mGy and reduced the exposure time from 3.2 s to 1.0 s. Over this range, the detection rate of fibrils and microcalcification-mimicking specks did not vary with tube potential at the 0.05 level of significance. It was found that only the low contrast mass detail detection rate at 35 kVp was significantly less than that at 28 kVp. The measured radiographic contrast decreased with tube potential and the SPR increased with tube potential. However, both changes were weak, and linear regressions determined that the 95% confidence intervals of the slopes relating both contrast and SPR with tube potential encompassed zero. It is concluded that magnification mammography performed at 34 kVp yields significant reductions in exposure time and mean glandular dose, with a detail detection capability similar to that at 28 kVp.

Breast Diseases↗

In vivo absorbed dose measurements in mammography using a new real-time luminescence technique.

A dosimetry system based on radioluminescence (RL) and optically stimulated luminescence (OSL) from carbon doped aluminium oxide (Al2O3:C) crystals was developed for in vivo absorbed dose measurements in mammography. A small cylindrical crystal of Al2O3:C (diameter 0.48 mm and length 2 mm) was coupled to the end of a 1 mm diameter optical fibre cable. Owing to their small size and characteristic shape, these probes can be placed on the body surface in the field of view during the examination, without compromising the reading of the mammogram. Our new technique was tested with a mammography unit (Siemens Mammomat 3000) and screen-film technique over a range of clinically relevant X-ray energies. The results were compared with those obtained from an ionization chamber usually used for the determination of absorbed dose in mammography. The reproducibility of measurements was around 3% (1 standard deviation) at 4.5 mGy for both RL and OSL data. The dose response was found to be linear between 4.5 mGy and 30 mGy. The energy dependence of the system is around 18% between 23 kV and 35 kV. In vivo measurements were performed during three patient examinations. It was shown that entrance and exit doses could be measured. The presence of the small probes did not significantly interfere with the diagnostic quality of the images. Entrance doses estimated by RL/OSL results agreed within 3% with entrance surface dose values calculated from the ionization chamber measurements. These results indicate a considerable potential for use in routine control and in vivo dose measurements in mammography.

Aluminum Oxide↗

A study of mean glandular dose during diagnostic mammography in Malaysia and some of the factors affecting it.

The primary objective of this study was to determine the mean glandular dose (MGD) during diagnostic mammography in Malaysia. The secondary objective was to evaluate some of the factors affecting MGD. A survey of standard MGD was performed, based upon quality control records for the period October 1999 to August 2001. This covered 30 mammography units from 9 manufacturers. MGD was also measured for a series of patients attending mammography examinations at three other mammography units. MGD per film was estimated from recorded radiographic factors, the compressed breast thickness (CBT) and X-ray unit calibration data. MGD per woman was calculated by summing the MGDs for all films, and averaging it over both breasts. 300 women drawn equally from three major ethnic groups, namely Malay, Chinese and Indian, took part in the study. The difference of MGD per woman between ethnic groups was tested for significance using non-parametric Kruskal-Wallis and median tests. The factors affecting MGD per woman were tested for significance using a multivariate analysis of variance. The MGD for the phantom was 1.23 mGy (range 0.22-2.39 mGy) while the mean patient based MGD per film was 1.54 mGy and 1.82 mGy for the craniocaudal and mediolateral oblique views, respectively. The mean MGD per woman was 3.37 mGy. It was also found that there is no significant difference in MGD per woman among the ethnic groups (p>0.05, Kruskal-Wallis test). However, on the multivariate test two factors, namely half value layer of the X-ray beam and (CBT), had a significant effect on MGD per woman (p<0.05). No significant relationships were seen between MGD per woman with respect to ethnicity, body mass index or age.

Adult↗

Dose reduction in full-field digital mammography: an anthropomorphic breast phantom study.

The aim of this study was to evaluate the potential for radiation dose reduction by using other beam qualities in full-field digital mammography (FFDM) compared with screen-film mammography (SFM). FFDM was performed using an amorphous silicon detector with a caesium iodide scintillator layer (Senographe 2000D, GE, Milwaukee, USA). SFM was performed using a state-of-the-art conventional system (Senographe DMR, GE, Milwaukee, USA) with a dedicated screen-film combination. An anthropomorphic breast phantom with superimposed microcalcifications (50-200 microm) was used to evaluate the detectability of microcalcifications. Contact mammograms and magnification views (m=1.8) performed with both the digital and the screen-film system were compared. Images were exposed automatically. Molybdenum/Molybdenum (Mo/Mo) anode-filter combination, 28 kVp and 63 mAs were selected by the automatic optimization of parameters (AOP) of the conventional system. This exposure protocol (protocol A) was also used as baseline for the digital system. Dose reduction in digital mammography was achieved by using protocol B with Mo/Rh and 31 kVp and protocol C with Rh/Rh and 32 kVp. The detectability of microcalcifications was assessed by 3 experienced readers with a confidence level ranging from 1 to 5. A receiver operating characteristic (ROC) analysis was performed. In protocol A the area under the ROC-curve (A(z)) for contact views performed by the screen-film system was 0.64 and for those performed with the FFDM system 0.68. The A(z) values were 0.74 in protocol B and 0.65 in protocol C for the digital system. For the conventional and digital magnification views A(z) values were 0.71 and 0.79, respectively. For protocol B the A(z) value was 0.81 and for protocol C it was 0.76. There is no statistically significant difference in the A(z) values for the different protocols in digital mammography and no significant difference from the screen-film system. A potential for dose reduction by using other beam qualities seems to be possible with this digital system.

Anthropometry↗

Towards in vivo TLD dosimetry in mammography.

While phantoms are used for quality control assessment of the mammography unit, in vivo dose measurements are necessary to account for the variation in size and composition of the female breast. The use of thermoluminescent dosimeters (TLDs) in mammography has been limited due to TLD visibility. The aim of this current investigation was to access the suitability of a paper-thin LiF:Mg,Cu,P TLD (GR-200F) for in vivo dosimetric mammography measurements. The visibility of GR-200F has been directly compared with LiF:Mg,Cu,P TLDs (GR-200A) using a number of commercially available phantoms. The phantoms of thickness 2-5 cm were imaged over the range of tube potentials (24-28 kVp) used clinically. Both types of TLD were placed on the surface of the phantoms allowing assessment of visibility, entrance surface dose (ESD) and field homogeneity. In vivo assessment of ESD and visibility was also carried out on a volunteer undergoing a routine mammography examination. The positions of the GR-200F TLDs were not identified either on the image of the Leeds TOR(MAM) phantom or the patient mammograms. The average ESD for the Leeds phantom was 8.8 mGy, while the patient ESD was 13 mGy. It is now possible to perform in vivo measurements with the potential of increasing the accuracy of the doses measured for women that do not conform to a standard breast thickness or density.

Breast Neoplasms↗

Measuring the performance of screening mammography in community practice with Medicare claims data.

BACKGROUND: Few studies have examined the outcomes of screening mammography in community practice, particularly the extent of false positive exams among older asymptomatic women. RESEARCH DESIGN: Subjects were female Medicare beneficiaries, age 67 or older, residing in one of eleven SEER areas, with no evidence of breast cancer. Medicare claims data were used to identify their screening mammograms over two time periods, 1993-1995 and 1996-1998, and to measure their use of follow-up diagnostic testing (diagnostic mammography, breast ultrasound and breast biopsy) within three months of the screening mammogram. RESULTS: There were significant differences among the rates of diagnostic testing for each age group (67-74; 75+ ) by year, but no clear trend toward higher or lower rates over time. Although rates of diagnostic testing differed significantly by geographic region in both time periods 1993-1995 and 1996-1998, estimates of specificity for all regions were within AHRQ clinical practice guidelines (specificity greater than 90%). Specificity significantly improved with the volume of the radiologist's practice for the latter time period (1996-1998) but not for the former (1993-1995). CONCLUSION: Medicare claims offer an accessible population-based source of data for mammography performance indicators. As such, they offer a low cost method for evaluating individual mammography practices as well as monitoring the impact of reimbursement policies, practice guidelines and laws mandating requirements for accrediting facilities.

Aged↗

Assertiveness with physicians: does it predict mammography use?.

In a prior study we found that women's self-reported assertiveness with their healthcare providers was associated with their use of mammography in a population-based cross-sectional sample of women. Women who reported being more assertive, by repeating information if they felt their doctor didn't hear them, asking their doctor to explain information they didn't understand, or reminding their doctor about screening tests, were more likely to have received a mammogram recently than those who reported being less assertive. Here we examined how women's self-reports of assertiveness predicted their use of mammography three years later. We examined this using a population-based sample of 781 women living in rural Washington State who were participating in a trial of mammography promotion. We found that assertive women were younger on average than less assertive women, but that even after controlling for age, education, income, and marital status, women who reported being assertive with their doctor in 1994 were more likely to receive regular mammograms in the next three years than those who did not (OR 2.1; CI 1.5, 2.9). If future studies also suggest that assertiveness predicts use of mammography or other preventive healthcare services, it would be valuable to examine the promotion of assertiveness as a means of improving public health.

Aged↗

News media coverage of a women's health contraversy: how newspapers and TV outlets covered a recent debate over screening mammography.

Over the past decade, there have been several highly visible debates about mammography that have captured professional, public and media attention. This paper looks at newspaper and television news coverage of a controversial research letter in The Lancet by Gøtzsche and Olsen (2001) that concluded that screening mammography did not prevent deaths from breast cancer. The news pieces examined for this project were published between October 2001 and March 2002 in one of eight U.S. newspapers or aired on one of six national or cable news networks. The six-month period was divided into one-week segments; the numbers of articles published or stories aired in each week were graphed to examine patterns. Each newspaper article and television transcript was then reviewed to identify its main content area and the amount of coverage for each major event was quantified. The highest number of newspaper articles appeared to result from several events during the end of January through the beginning of February. These events included the publication of another meta-analysis of mammography that disputed the original letter's conclusion and a full-page New York Times advertisement paid for by major medical organizations stating their continued support for mammography. The greatest amount of television news coverage was devoted to the announcement of the official federal guidelines by the Secretary of Health and Human Services in late February. We conclude by discussing how the flow of news coverage of medical controversies can potentially impact the actions and reactions of the public, the medical community and health policy makers.

Bibliometrics↗

Mammography screening services: market segments and messages.

Mammography has become a vital tool for the early detection of breast cancer. Although many organizations and health care facilities are working to educate and motivate women to take advantage of the life saving opportunity that is offered through screening mammography, only twenty percent of women who should be screened actually have the procedure performed. In order to reach women who have not been screened, it is important to learn which factors most strongly motivate those women who do choose to have a mammogram. Depth interviews with 18 women attending a mobile mammography unit were conducted to explore the decision making process of women obtaining mammography screening services and to develop a profile of prevalent emotions, attitudes, and feelings associated with receiving breast cancer screening services. Analysis of the interview transcripts revealed several important themes to which health care professionals can direct marketing and health promotion strategies.

Adult↗

Mammography rescreening among women of diverse ethnicities: patient, provider, and health care system factors.

This study identified patient, provider, and health care system factors that influenced mammography rescreening among non-insured, racial/ethnic minority women. Data were collected using a stratified-clustered random sample survey of 1,050 women of five racial/ethnic groups (Latina, Chinese, Filipina, African American, and Caucasian) and 102 primary care clinical sites. Women received screening services through two no-cost screening programs in California. Chi-square tests were used to assess bivariate associations and multiple logistic regressions were used to compute adjusted odds ratios and 95% confidence intervals. Mammography rescreening was associated with living in the United States longer; having higher education levels, better health care access, a history of breast problems, and favorable perceptions of mammography; obtaining regular Pap screening and hormone replacement therapy; having had better communication with clinicians; and attending clinics that conducted in-reach activities. This study suggests that simply removing financial barriers is not enough to improve mammography rescreening among underserved women.

Aged↗

Literacy and knowledge, attitudes and behavior about mammography in Latinas.

This cross-sectional study explored the association between functional health literacy and the knowledge, beliefs, attitudes, and behavior about mammography and self-breast examination in a sample of Latinas attending community health clinics in Philadelphia. The results show that 70% of Latinas had inadequate or marginal functional health literacy. In Latinas, functional health literacy is only weakly associated with knowledge and not associated with beliefs and attitudes about screening mammography, but is significantly associated with having ever had a mammogram. After adjusting for demographic characteristics, functional health literacy was significantly associated with having ever had a mammogram (odds ratio [OR] 1.14, 95% confidence interval [CI] 1.02-1.27). These findings suggest that Latinas with poor functional health literacy are less likely to undergo mammography. Future research should target increasing the knowledge about and rates of screening mammography in patients with low functional health literacy.

Adult↗