Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

A microfluidic chip based sequential injection system with trapped droplet liquid-liquid extraction and chemiluminescence detection.

A microfluidic chip-based sequential injection system with trapped droplet liquid-liquid extraction preconcentration and chemiluminescence detection was developed for achieving high sensitivity with low reagent and sample consumption. The microfabricated glass lab-chip had a 35 mm long extraction channel, with 134 shrunken opening rectangular recesses (L 100 microm x W 50 microm x D 25 microm) arrayed within a 1 mm length on both sides of the middle section of the channel. Ketonic peroxyoxalate ester solution was filled in the recesses forming organic droplets, and keeping the aqueous sample solution flowing continuously in the extraction channel; analytes were transferred from the aqueous phase into the droplets through molecular diffusion. After liquid-liquid extraction preconcentration, catalyst and hydrogen peroxide solutions were introduced into the channel, and mixed with analytes and peroxyoxalate ester to emit chemiluminescence light. The performance of the system was tested using butyl rhodamine B, yielding a precision of 4% RSD (n = 5) and a detection limit of 10(-9) M. Within a 17 min analytical cycle, the consumptions of sample and peroxyoxalate solutions were 2.7 microL and 160 nL, respectively.

Journal Article↗

Disposable real-time microPCR device: lab-on-a-chip at a low cost.

We have designed, fabricated and tested a real-time micro polymerase chain reaction (microPCR) system. It consists of a microscope glass cover slip placed on top of a micromachined silicon chip integrated with a heater and a temperature sensor. A single microL of a sample containing DNA was placed on the glass and encapsulated with mineral oil to prevent the evaporation of water, thus forming a virtual reaction chamber (VRC). The PCR chip required half a second to heat up from 72 to 94 degrees C and two seconds to cool from 94 to 55 degrees C, corresponding to a cooling rate of -20 K s(-1). The real-time PCR yield was determined by a fluorescence method. The melting curve analysis method as well as capillary electrophoresis was performed to determine the purity of the PCR product. As the glass slip is disposable, cross-contamination from sample to sample is eliminated. The total cost of running the PCR is given by the value of the cover slip and its treatment.

Costs and Cost Analysis↗

A bio-barcode assay for on-chip attomolar-sensitivity protein detection.

Functionalized nanoparticles hold great promise in realizing highly sensitive and selective biodetection. We report a single disposable chip which is capable of carrying out a multi-step process that employs nanoparticles--a bio-barcode assay (BCA) for single protein marker detection. To illustrate the capability of the system, we tested for the presence of prostate specific antigen (PSA) in buffer solution and goat serum. Detection was accomplished at PSA concentrations as low as 500 aM. This corresponds to only 300 copies of protein analytes using 1 microL total sample volume. We established that the on-chip BCA for PSA detection offers four orders of magnitude higher sensitivity compared to commercially available ELISA-based PSA tests.

Animals↗

High-speed fabrication of patterned colloidal photonic structures in centrifugal microfluidic chips.

In this paper, we report a rapid and facile method for fabricating colloidal photonic crystals inside microchannels of radially symmetric microfluidic chips which were made using soft-lithography. As the suspension of monodisperse silica or polystyrene latex spheres was driven to flow through the channels under the action of centrifugal force, the colloidal spheres were quickly assembled into face centered cubic arrangement which had a few photonic stop bands. The soft-microfluidic channels and cells confined the colloidal crystals into designed patterns. The optical reflectance was modulated by the refractive-index mismatch between the colloidal particles and the solvent in the interstices between the particles. Therefore, the present microfluidic chips with built-in colloidal photonic crystals can be used as in-situ optofluidic microsensors for high throughput screening or light filters in integrated adaptive optical devices.

Colloids↗

Compact fluorescence detection using in-fiber microchannels-its potential for lab-on-a-chip applications.

This paper reports a compact and practical fluorescence sensor using an in-fiber microchannel. A blue LED, a multimode PMMA or silica fiber and a mini-PMT were used as an excitation source, a light guide and a fluorescence detector, respectively. Microfluidic channels of 100 microm width and 210 microm depth were fabricated in the optical fibers using a direct-write CO(2) laser system. The experimental results show that the sensor has high sensitivity, able to detect 0.005 microg L(-1) of fluorescein in the PBS solution, and the results are reproducible. The results also show that the silica fiber sensor has better sensitivity than that of the PMMA fiber sensor. This could be due to the fouling effect of the frosty layer formed at the microchannel made within the PMMA fiber. It is believed that this fiber sensor has the potential to be integrated into microfluidic chips for lab-on-a-chip applications.

Fluorescein↗

A high-performance elastomeric patch clamp chip.

Ion channels play key roles in cell physiology and underlie a broad spectrum of disorders. To this day, the gold standard for studying ion channels is the patch clamp technique. Patch clamping involves careful positioning of a fine-tipped glass micropipette onto the surface of the cell to form a high-resistance (>1 Gohms) seal ("gigaseal"), a procedure that is laborious, vibration-sensitive, and not easily amenable to automation. In addition, the solution inside the pipette cannot be easily exchanged. Recently reported patch clamp chips offer the potential of increased throughput, but to date the overall per-cell performance of most designs has been very low when compared to pipettes, and/or the fabrication process is prohibitively expensive. Here we demonstrate a replica-molded elastomeric patch clamp chip incorporating nanofabricated constrictions, which delivers high-stability gigaseals, with success rates comparable to those of pipettes, using rat basophilic leukemia (RBL) cells. The high stability enables exchanges of both the extracellular and intracellular solution during whole-cell recordings. In a sample of 103 experiments, 66 cells (64%) were successfully immobilized at the patch aperture; 38 cells (58% of immobilized cells, 37% of all cells) were successfully gigasealed; and 25 cells (65% of gigasealed cells, 34% of immobilized cells, 24% of all cells) were successfully perforated for whole-cell access. In the last group of 27 experiments, 79% of the cells could be immobilized, of which 68% could be gigasealed and 46% perforated for whole-cell access, indicating that dexterity is important.

Animals↗

The Artificial Synapse Chip: a flexible retinal interface based on directed retinal cell growth and neurotransmitter stimulation.

The Artificial Synapse Chip is an evolving design for a flexible retinal interface that aims to improve visual resolution of an electronic retinal prosthesis by addressing cells individually and mimicking the physiological stimulation achieved in synaptic transmission. We describe three novel approaches employed in the development of the Artificial Synapse Chip: (i) micropatterned substrates to direct retinal cell neurite growth to individual stimulation sites; (ii) a prototype retinal interface based on localized neurotransmitter delivery; and (iii) the use of soft materials to fabricate these devices. By patterning the growth of cells to individual stimulation sites, we can improve the selectivity of stimulation and decrease the associated power requirements. Moreover, we have microfabricated a neurotransmitter delivery system based on a 5- micro m aperture in a 500-nm-thick silicon nitride membrane overlying a microfluidic channel. This device can release neurotransmitter volumes as small as 2 pL, demonstrating the possibility of chemical-based prostheses. Finally, we have fabricated and implanted an equivalent device using soft flexible materials that conform to the retinal tissue more effectively. As many of the current retinal prosthesis devices use hard materials and electrical excitation at a lower resolution, our approach may provide more physiologic retinal stimulation.

Animals↗

Proteomic classification of pancreatic adenocarcinoma tissue using protein chip technology.

BACKGROUND & AIMS: Pancreatic adenocarcinoma is a most devastating cancer that presents late and is rapidly progressive. This study aimed to identify unique, tissue-specific protein biomarkers capable of differentiating pancreatic adenocarcinoma (PC) from adjacent uninvolved pancreatic tissue (AP), benign pancreatic disease (B), and nonmalignant tumor tissue (NM). METHODS: Tissue samples representing PC (n = 31), AP (n = 44), and B (n = 19) tissue were analyzed on hydrophobic protein chip arrays by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry. Training models were developed using logistic regression and validated using the 10-fold cross-validation approach. RESULTS: The hydrophobic protein chip array revealed 13 protein peaks differentially expressed between PC and AP (receiver operating characteristic [ROC] area under the curve [AUC], 0.64-0.85), 8 between PC and B (ROC AUC, 0.67-0.78), and 12 between PC and NM tissue (ROC AUC, 0.63-0.81). Logistic regression and cross-validation identified overlapping panels of peaks to develop a training model that distinguished PC from AP (77.4% sensitivity, 84.1% specificity), B (83.9% sensitivity, 78.9% specificity), and NM tissue (58.1% sensitivity, 90.5% specificity). The final panels selected correctly classified 80.6% of PC and 88.6% of AP samples (ROC AUC, 0.92), 93.5% of PC and 89.5% of B samples (ROC AUC, 0.99), and 71.0% of PC and 92.1% of NM samples (ROC AUC, 0.91). CONCLUSIONS: This study used surface-enhanced laser desorption/ionization time-of-flight mass spectrometry to discover a number of protein panels that can distinguish effectively between pancreatic adenocarcinoma, benign, and adjacent pancreatic tissue. Identification of these proteins will add to our understanding of the biology of pancreatic cancer. Furthermore, these protein panels may have important diagnostic implications.

Adenocarcinoma↗

[Interdisciplinary management of complex chronic ulcers using vacuum assisted closure therapy and "buried chip skin grafts"].

HISTORY AND ADMISSION FINDINGS: We report the case of a 68-year-old female patient who was admitted to the hospital with deranged blood sugar levels in a septic condition. Due to complex chronic ulcerations of both feet she was intended for major amputation of both limbs. Clinical findings on admission were a diabetic foot syndrome with stage D IV ulcerations according to the Wagner and Armstrong classification, partially visible tendons and phlegmon of the lower leg. INVESTIGATIONS AND CLINICAL COURSE: Vascular diagnostic revealed arterial occlusive disease in the lower legs without chance of reconstruction. Enterococcus faecalis and Staphylococcus aureus were extracted in swabs from ulcers. After correction of metabolic status and antibiotic treatment radical débridement of all ulcers was carried out and vacuum assisted closure therapy (V.A.C.) was initiated. All wounds showed good granulation tissue after four cycles of V.A.C.-therapy. Interdisciplinary treatment with a plastic surgeon was initiated to accelerate epithelial closure. Using the "Buried Skin Chip" technique in combination with V.A.C.-therapy epithelialisation was completed within four weeks. The patient recovered well and was fully independent on discharge. DISCUSSION AND CONCLUSION: A goal-oriented interdisciplinary setting can achieve preservation of extremities even in septic patients. The combination of buried skin chip grafts and V.A.C.-therapy may be a feasible and promising procedure to achieve accelerated wound closure in those patients.

Aged↗

Localized chemical release from an artificial synapse chip.

A device that releases chemical compounds in small volumes and at multiple, well defined locations would be a powerful tool for clinical therapeutics and biological research. Many biomedical devices such as neurotransmitter-based prostheses or drug delivery devices require precise release of chemical compounds. Additionally, the ability to control chemical gradients will have applications in basic research such as studies of cell microenvironments, stem cell niches, metaplasia, or chemotaxis. We present such a device with repeatable delivery of chemical compounds at multiple locations on a chip surface. Using electroosmosis to drive flow through microfluidic channels, we pulse minute quantities of a bradykinin solution through four 5-microm apertures onto PC12 cells and show stimulation of individual cells using a Ca(2+)-sensitive fluorescent dye. We also present basic computational results with experimental verification of both fluid ejection and fluid withdrawal by imaging pH changes by using a fluorescent dye. This "artificial synapse chip" is a prototype neural interface that introduces a new paradigm for neural stimulation, with eventual application in treating macular degeneration and other neurological disorders.

Animals↗

The Anopheles gambiae detoxification chip: a highly specific microarray to study metabolic-based insecticide resistance in malaria vectors.

Metabolic pathways play an important role in insecticide resistance, but the full spectra of the genes involved in resistance has not been established. We constructed a microarray containing unique fragments from 230 Anopheles gambiae genes putatively involved in insecticide metabolism [cytochrome P450s (P450s), GSTs, and carboxylesterases and redox genes, partners of the P450 oxidative metabolic complex, and various controls]. We used this detox chip to monitor the expression of the detoxifying genes in insecticide resistant and susceptible An. gambiae laboratory strains. Five genes were strongly up-regulated in the dichlorodiphenyltrichloroethane-resistant strain ZAN/U. These genes included the GST GSTE2, which has previously been implicated in dichlorodiphenyltrichloroethane resistance, two P450s, and two peroxidase genes. GSTE2 was also elevated in the pyrethroid-resistant RSP strain. In addition, the P450 CYP325A3, belonging to a class not previously associated with insecticide resistance, was expressed at statistically higher levels in this strain. The applications of this detox chip and its potential contribution to malaria vector insecticide resistance management programs are discussed.

Anopheles↗

Ultra-high-speed DNA fragment separations using microfabricated capillary array electrophoresis chips.

Capillary electrophoresis arrays have been fabricated on planar glass substrates by photolithographic masking and chemical etching techniques. The photolithographically defined channel patterns were etched in a glass substrate, and then capillaries were formed by thermally bonding the etched substrate to a second glass slide. High-resolution electrophoretic separations of phi X174 Hae III DNA restriction fragments have been performed with these chips using a hydroxyethyl cellulose sieving matrix in the channels. DNA fragments were fluorescently labeled with dye in the running buffer and detected with a laser-excited, confocal fluorescence system. The effects of variations in the electric field, procedures for injection, and sizes of separation and injection channels (ranging from 30 to 120 microns) have been explored. By use of channels with an effective length of only 3.5 cm, separations of phi X174 Hae II DNA fragments from approximately 70 to 1000 bp are complete in only 120 sec. We have also demonstrated high-speed sizing of PCR-amplified HLA-DQ alpha alleles. This work establishes methods for high-speed, high-throughput DNA separations on capillary array electrophoresis chips.

Cellulose↗

The chaperone-associated ubiquitin ligase CHIP is able to target p53 for proteasomal degradation.

The cellular level of the tumor suppressor p53 is tightly regulated through induced degradation via the ubiquitin/proteasome system. The ubiquitin ligase Mdm2 plays a pivotal role in stimulating p53 turnover. However, recently additional ubiquitin ligases have been identified that participate in the degradation of the tumor suppressor. Apparently, multiple degradation pathways are employed to ensure proper destruction of p53. Here we show that the chaperone-associated ubiquitin ligase CHIP is able to induce the proteasomal degradation of p53. CHIP-induced degradation was observed for mutant p53, which was previously shown to associate with the chaperones Hsc70 and Hsp90, and for the wild-type form of the tumor suppressor. Our data reveal that mutant and wild-type p53 transiently associate with molecular chaperones and can be diverted onto a degradation pathway through this association.

Cell Line↗

Identification of VCP/p97, carboxyl terminus of Hsp70-interacting protein (CHIP), and amphiphysin II interaction partners using membrane-based human proteome arrays.

Proteins mediate their biological function through interactions with other proteins. Therefore, the systematic identification and characterization of protein-protein interactions have become a powerful proteomic strategy to understand protein function and comprehensive cellular regulatory networks. For the screening of valosin-containing protein, carboxyl terminus of Hsp70-interacting protein (CHIP), and amphiphysin II interaction partners, we utilized a membrane-based array technology that allows the identification of human protein-protein interactions with crude bacterial cell extracts. Many novel interaction pairs such as valosin-containing protein/autocrine motility factor receptor, CHIP/caytaxin, or amphiphysin II/DLP4 were identified and subsequently confirmed by pull-down, two-hybrid and co-immunoprecipitation experiments. In addition, assays were performed to validate the interactions functionally. CHIP e.g. was found to efficiently polyubiquitinate caytaxin in vitro, suggesting that it might influence caytaxin degradation in vivo. Using peptide arrays, we also identified the binding motifs in the proteins DLP4, XRCC4, and fructose-1,6-bisphosphatase, which are crucial for the association with the Src homology 3 domain of amphiphysin II. Together these studies indicate that our human proteome array technology permits the identification of protein-protein interactions that are functionally involved in neurodegenerative disease processes, the degradation of protein substrates, and the transport of membrane vesicles.

Adenosine Triphosphatases↗

A nonredundant human protein chip for antibody screening and serum profiling.

There is burgeoning interest in protein microarrays, but a source of thousands of nonredundant, purified proteins was not previously available. Here we show a glass chip containing 2413 nonredundant purified human fusion proteins on a polymer surface, where densities up to 1600 proteins/cm(2) on a microscope slide can be realized. In addition, the polymer coating of the glass slide enables screening of protein interactions under nondenaturing conditions. Such screenings require only 200-microl sample volumes, illustrating their potential for high-throughput applications. Here we demonstrate two applications: the characterization of antibody binding, specificity, and cross-reactivity; and profiling the antibody repertoire in body fluids, such as serum from patients with autoimmune diseases. For the first application, we have incubated these protein chips with anti-RGSHis(6), anti-GAPDH, and anti-HSP90beta antibodies. In an initial proof of principle study for the second application, we have screened serum from alopecia and arthritis patients. With analysis of large sample numbers, identification of disease-associated proteins to generate novel diagnostic markers may be possible.

Alopecia↗

Adsorption of lipase on hollow fiber membrane chips.

The amount of lipase from Mucor miehei adsorption on ultrafiltration polysulfone hollow fiber membrane chips has been determined using different lipase concentrations at three different temperatures, namely 30, 35, and 40 degrees C. It was experimentally shown that adsorption of lipase increases with temperature. The results were used to evaluate the constants found in the Langmuir adsorption isotherm model coupled with the Van't Hoff's relationship. A temperature dependence correlation for the amount of adsorbed lipase activity, alip,ads, and that present in the supernatant solution, alip,free was determined. The effect of varying the concentration on a cross-linking agent, namely, glutaraldehyde, to the membrane chips was also tested. It was found that, under the same operating conditions, the amount of lipase adsorbed on polysulfone membranes was increased dramatically after pre-treating the membrane with 1% Glutaraldehyde. However, increasing the concentration of the cross-linking agent has a low effect on the amount of lipase adsorbed.

Adsorption↗

Lead exposures during shipboard chipping and grinding paint-removal operations.

Shipboard chipping and grinding paint-removal operations were evaluated to determine personnel exposures to airborne lead concentrations. Lead concentrations found in the bulk lead-paint samples ranged from 0.0037 to 11.5% by weight. Of the personnel conducting paint removal operations, 62% were exposed at or above the Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit for lead of 50 micrograms/m3. Correlations of airborne lead concentrations and bulk lead-paint contents for chipping and grinding operations were statistically significant. Blood lead (Pb) levels were significantly higher in the follow-up blood tests when compared to the initial blood tests taken prior to paint removal. However, blood Pb levels were well below the OSHA allowable level of 40 micrograms/100 g.

Air Pollutants, Occupational↗

Human papillomavirus genotyping by the DNA chip in the cervical neoplasia.

Human papillomavirus (HPV) is implicated as an etiologic agent in neoplasitc lesions of the cervix. In this study, we used an HPV DNA chip to detect the type-specific sequence of HPV from cervical swabs in women with biopsy- proven neoplastic lesions of the cervix. Four hundred seventy-one patients were involved and classified into four groups based on the cytopathologic diagnosis: group I (normal, n = 290), group II (low-grade squamous intraepithelial lesions (SIL), n = 68), group III (high-grade SIL, n = 51), and group IV (invasive cervical cancer, n = 55). HPV detection rates were 17.6% (51 of 290), 73.5% (50 of 68), 92.2% (47 of 51), and 95.2% (59 of 62) in patients of group I to group IV, respectively. HPV-16 was the most frequent type (21.8%) in all specimens tested, and significantly increased the prevalence by advancing the grade of the cervical lesions (P < 0.01). The next frequent virus types were HPV-18 and HPV-58. The prevalence of multiple HPV infections was 37.3, 43.7, 27.7, and 28.8%, and no significant difference was detected between each group (P > 0.05). This suggests that the HPV DNA chip is a sensitive diagnostic tool for the detection of HPV in cervical specimens, and that it would provide more useful information on viral genotype and multiple HPV infections. Taken together, molecular biological data on HPV might be beneficial for the prevention and management of cervical neoplastic lesions.

Female↗