Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Atrial Flutter”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Flecainide acetate in atrial flutter and fibrillation. The arrhythmogenic effects.

The arrhythmogenic effects of flecainide in atrial fibrillation and flutter were assessed in a consecutive material of 100 patients without severe heart failure (NYHA class I or II). Severe arrhythmogenic events occurred in 9% (4-16%) of the patients: within the first 5 days of treatment in seven patients, and in two patients after 60 and 240 days of flecainide treatment. Patients with proarrhythmic events tended to be older and to have a longer QRS duration. Following flecainide therapy conversion to sinus rhythm was achieved in 21 of 43 patients (49%) with atrial fibrillation and in 10 of 29 (34%) with atrial flutter. It is concluded that flecainide, although an effective antiarrhythmic drug, has potential proarrhythmic effects and therefore cautious use of this drug is mandatory.

Aged↗

Clinical study regarding the anatomical structures of the right atrial isthmus using intra-cardiac echocardiography: implication for catheter ablation of common atrial flutter.

BACKGROUND: The construction of complete bi-directional block in the isthmus (ITH) between the tricuspid annulus and inferior vena cava by radiofrequency energy (RF) applications is sometimes hampered due to anatomical problems such as a thick isthmus or aneurysmal pouch in patients with common atrial flutter (AFL). METHODS AND RESULTS: Fifteen patients were referred for RF ablation of AFL. The anatomical thickness of the right atrial ITH, diameter of the right atrium and thickness of the right atrial free wall were determined using intracardiac echocardiography (ICE), along with the endocardial electrogram recordings at the ITH. RF was applied at the ITH to create a transmural incision to treat the AFL. A significant parallel relationship between the maximum amplitude of the atrial electrogram and the thickness of the ITH, was observed. When the maximum amplitude of the atrial electrogram at the ITH exceeded 1.5 mV, the thickness at the ITH was approximately larger than 5 mm. CONCLUSIONS: Using ICE, the precise measurement of the anatomical structures in the heart, including the ITH, was feasible. From the amplitude of the atrial electrogram, a deduction of the thickness at the ITH was possible, which is indispensable information for the appropriate selection of the RF devices.

Adult↗

Acute results of transvenous cryoablation of supraventricular tachycardia (atrial fibrillation, atrial flutter, Wolff-Parkinson-White syndrome, atrioventricular nodal reentry tachycardia).

INTRODUCTION: Radiofrequency (RF) catheter ablation currently is used for treatment of cardiac arrhythmias. Although the success rate is high for almost all supraventricular tachycardias (SVT), this technique has some drawbacks, especially when pulmonary veins (PV) are targeted for treatment of atrial fibrillation (AF). Additionally, new techniques for isolation of the PVs have the drawback that they can be used only for PV isolation and not for routine treatment of other SVTs. The aim of this study was to report on the safety and efficacy of a new cryoablation system for treatment of all SVTs. METHODS AND RESULTS: Forty-nine patients with SVT (38 men; age 48 years, range 23-76) were enrolled in the study. Five patients were withdrawn from the study before they underwent cryoablation. The remaining 44 patients were treated with cryoablation (22 AF, 15 atrial flutter, 3 accessory pathway, 2 AV nodal reentrant tachycardia, 1 AV junction ablation for permanent AF, 1 atrial tachycardia). Cryoablation was performed with the CryoCor cryoablation system, which uses a precooling system and N2O as a refrigerant. The number of freezes applied varied according to the index arrhythmia treated. Successful isolation of PVs was performed in 20 of (96%) 21 AF patients and 53 of 55 veins. The overall acute success was 98% (43/44). Fifty-three PVs were isolated (2.5/patient). The success rate was 100% (23/23) for right-sided procedures. The average and nadir temperatures reached in right-sided and left-sided procedures were -77 degrees C and -80 degrees C and -75 degrees C and -78 degrees C, respectively. No acute PV stenosis was seen. CONCLUSION: This novel cryoablation system appears to be safe and can successfully treat different types of SVTs, including AF. Isolation of PVs is possible without producing stenosis. Despite the high blood flow in the right atrial isthmus and PVs, bidirectional conduction block can be achieved.

Adult↗

Catheter ablation of typical atrial flutter: a randomized comparison of 2 methods for determining complete bidirectional isthmus block.

BACKGROUND: Complete bidirectional isthmus conduction block (CBIB) was initially assessed by sequential detailed activation mapping at both sides of the ablation line during proximal coronary sinus and anteroinferior right atrium pacing. Mapping only the ablation line ("on-site" atrial potential analysis) was recently reported as a means of CBIB identification. The study was designed to compare these 2 techniques prospectively regarding the diagnosis of CBIB. METHODS AND RESULTS: In 76 consecutive patients (mean age, 63.4+/-10.5 years), typical atrial flutter ablation was performed using either the activation mapping technique (group I) or on-site atrial potential analysis (group II). Criteria for CBIB using on-site atrial potential analysis was the recording of parallel, widely spaced double atrial potentials along the ablation line. The CBIB criterion was retrospectively searched using the alternative technique at the end of the procedure. In successful patients, the mean radiofrequency delivery duration was longer in group II (845+/-776 versus 534+/-363 s; P:=0.03). On-site, clear-cut, widely spaced double atrial potentials and activation mapping suggesting CBIB were concomitantly observed in only 47 patients (54%), and ambiguous/atypical double potentials were recorded in 31 patients (39%). CONCLUSIONS: Although feasible, the on-site atrial potential analysis seemed to be inferior to the classic activation mapping technique, mainly because of the ambiguity of electrogram interpretation along the ablation line. However, when combined with the activation mapping technique, it provided additional information regarding isthmus conduction properties in some cases. Therefore, optimally, both methods should be used concomitantly.

Aged↗

Evaluation of transisthmus conduction interval in predicting bidirectional block after ablation of typical atrial flutter.

OBJECTIVE: To determine whether the extent of prolongation of the transisthmus interval after ablation predicts complete bidirectional block. METHODS: Since 1996 to 2002, 30 consecutive patients underwent ablation procedures for isthmus-dependent atrial flutter. There were 23 males and 7 females [mean age (47.85 +/- 9.35) years]. With the use of fluoroscopic view of anatomy, radiofrequency ablation was performed during coronary sinus pacing at a cycle length of 600 ms. RESULTS: Bidirectional block was achieved with ablation in 29 (97%) of 30 patients. The transisthmus intervals before ablation and after complete transisthmus block were (73.82 +/- 13.01) ms and (140.47 +/- 20.48) ms, respectively, in the clockwise direction (P < 0.0001), and (77.63 +/- 8.36) ms and (138.17 +/- 15.55) ms, respectively, in the counterclockwise direction (P < 0.0001). A period of incomplete isthmus block was observed during 17 (58%) of the 29 ablation procedures. The clockwise transisthmus intervals during incomplete block [(107.65 +/- 21.33) ms] were (45.5 +/- 8.7)% longer than the baseline transisthmus intervals. An increase in the transisthmus interval by > or = 50% in both directions after ablation predicted complete bidirectional block with 100.0% sensitivity and 83.3% specificity. The positive and negative predictive values were 90.6% and 100.0%, respectively. The diagnostic accuracy of a > or = 50% prolongation in the transisthmus interval was 83.3%. CONCLUSION: The analysis of transisthmus interval is a valuable method for determining complete bidirectional isthmus block.

Atrial Flutter↗

[Characteristic electrocardiographic procedures of isthmic-dependent atrial flutter; influence of clinical and echocardiographic procedures].

The appearance of the F waves on the ECG is considered to be related to the type of circuit of the anti-clockwise flutters and the clockwise isthmic-dependant flutters. In the authors' experience, the usual ECG description of these two types of flutter is not always observed. This study was undertaken to analyse the different appearances of anti-clockwise and clockwise flutters and to try and explain the reasons for these differences. Over a 4 year period, 139 patients with an ECG of atrial flutter required electro-physiological studies and echocardiography of the 156 flutters analysed: 130 were anti-clockwise and 26 clockwise. Three types of anti-clockwise flutter were observed: type 1 with exclusively negative F waves in the inferior leads: type 2 and 3 with negative F waves in the inferior leads and a small (type 2) or large (type 3) positive terminal components. The types 2 and 3 were associated with a higher incidence of left atrial dilatation, cardiac disease and atrial fibrillation than type 1. Two types of clockwise flutter were observed: type 1 with positive notched F waves in the inferior leads with a return to the iso-electric line and type 2 with wide F waves in the inferior leads with two components, predominantly positive and negative, without return to the iso-electric line. There are different ECG appearances of anti-clockwise and clockwise flutter which seem to be correlated with structural cardiac abnormalities. The anti-clockwise flutters with a positive terminal component of the F waves in the inferior leads corresponds to a subgroup with a high probability of cardiac disease and left atrial dilatation.

Atrial Flutter↗

Relationship between surface electrocardiogram characteristics and endocardial activation sequence in patients with typical atrial flutter.

OBJECTIVES: The relationships that exist between endocardial and surface electrocardiogram (ECG) activity in patients with AFl have not been satisfactorily delineated. The aim of the study was to determine the relationships that exist between the atrial endocardial activity and the surface ECG in patients with atrial flutter (AFl). METHODS: In 40 patients with AFl, a 64-electrode basket catheter (BC) was deployed in the right atrium (RA). A decapolar catheter was inserted into the coronary sinus (CS) to record from the left atrium. The temporal relationship between endocardial and surface ECG activity was determined by means of electronic calipers. RESULTS: In counterclockwise AFl, the activation of the lateral wall of RA coincided with the positive deflections in lead I, V1 and V6 and the upstroke component in inferior leads. Plateau duration in lead III (121 +/- 27 ms) correlated strongly with isthmus conduction time (117 +/- 23 ms) (r = 0.91). Septal and left atrial conduction coincided with negative components in lead I, inferior leads and V6 and positive deflections in leads aVL and V1. In clockwise AFl, the F wave was notched in all ECG leads. The first component resulted from the activation of the septum and posterior wall of the RA. The second component was coincident with activity recorded in CS electrograms. The interval between the two deflections (60 +/- 18 ms) correlated strongly with interatrial conduction time (57 +/- 19 ms) (r = 0.84). Interatrial conduction interval was prolonged during AFl as compared to sinus rhythm (60 +/- 18 ms vs 43 +/- 13 ms, p = 0.04). Activation of the lateral wall of RA coincided with the negative components in lead I, inferior leads and V6. CONCLUSIONS: The electrical activity in surface ECG closely correlates with conduction in specific parts of the atria. Polarity of the F wave in an ECG lead is determined by a resultant of opposing activities from the lateral wall of the RA and the left atrium.

Aged↗

Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8- or 10-mm electrode catheters and a high-output radiofrequency energy generator: results of a multicenter safety and efficacy study.

OBJECTIVES: We studied the safety and efficacy of atrial flutter (AFL) ablation using 8- or 10-mm electrode catheters and a 100-W radiofrequency (RF) generator. BACKGROUND: Large-tip electrode catheters may be more effective for ablation of AFL. METHODS: There were 169 patients (age 61 +/- 12 years). Short-term end points were bidirectional isthmus block and no inducible AFL. After ablation, patients were seen at one, three, and six months, with event monitoring performed weekly and for any symptoms. Three quality-of-life (QOL) surveys were completed during follow-up. RESULTS: Short-term success was achieved in 158 patients (93%), with 12 +/- 11 RF applications. The efficacy of 8- and 10-mm electrodes was similar (p = NS). The number of RF applications (10 +/- 8 vs. 14 +/- 8) and ablation time (0.5 +/- 0.4 h vs. 0.8 +/- 0.6 h) were less with the 10- versus 8-mm electrode, respectively (p < 0.01). Of 158 patients with short-term success, 42 patients were not evaluated for success at six months because of study exclusions. Of 116 patients with short-term success evaluated at six months, 112 (97%) patients had no AFL recurrence. Of those without AFL recurrence at six months, 95% and 93% remained free of symptoms at 12 and 24 months, respectively. Ablation of AFL improved QOL scores (p < 0.05) and reduced anti-arrhythmic and rate-control drug use (p < 0.05). Complications occurred in 6 (3.6%) of 169 patients, but there were no deaths. CONCLUSIONS: Ablation of AFL with 8- or 10-mm electrode catheters and a high-power RF generator was safe and effective and improved QOL. The number and duration of RF applications were lower with 10- versus 8-mm electrode catheters.

Aged↗

Acceleration of ventricular response to atrial flutter after intravenous adenosine.

Adenosine may be of therapeutic and diagnostic value in the emergency management of arrhythmias. It causes transient atrioventricular nodal block and thus ends paroxysmal supraventricular tachycardias that involve the atrioventricular node. Also, it may uncover underlying atrial arrhythmias by slowing the ventricular response. Its duration of action is brief and serious adverse effects have not been reported. A 12 year old patient with atrial flutter is presented, in whom intravenous adenosine was followed by acceleration of the heart rate to a potentially dangerous arrhythmia.

Adenosine↗

Monitoring the local electrogram at the ablation site during radiofrequency application for common atrial flutter.

Recent studies have suggested that the attenuation of the local electrogram amplitude recorded from the ablation electrode during radiofrequency (RF) application predicts lesion growth. This study examined the time course of local electrogram amplitude during ongoing RF delivery in patients with common atrial flutter (AFl). In 71 patients with AFl. RF energy was applied to the anatomical isthmus. Termination of AFl was noted during 68 of 625 applications of RF energy. The changes in local atrial electrogram amplitude observed at all successful sites were analyzed. With increasing duration of the RF delivery, the electrogram amplitude decreased exponentially to reach a steady state within a mean duration of 17+/-3 sec, which was significantly longer than that of the steady-state temperature. The average decrease in the amplitude was 67+/-13%. In 16 patients in whom an increase in the power of RF energy had resulted in AFl termination, there was a dose-response relationship between the power and the amplitude decrease. The decrease in local electrogram amplitude appears to be a reliable marker for the efficacy of tissue heating and may be useful as an endpoint for individual applications. Local electrogram monitoring may offer an optimal energy strategy in AFl ablation.

Atrial Flutter↗

Atrial flutter followed by sick sinus syndrome as presenting symptoms of B-cell malignant non-Hodgkin lymphoma involving the heart.

A case of non-Hodgkin lymphoma involving the heart is described; the patient suffered for atrial flutter, followed by sick sinus syndrome for one year before diagnosis was made. Although it is not possible to demonstrate primary cardiac onset, the clinical history is highly suggestive. Most recent cases described occurred in immunodeficient patients. Interestingly our patient showed no evidence of immunodeficiency. Our patient received conventional chemotherapy followed by radiotherapy, obtaining complete remission without complications, and remains in this condition after a 3-year follow-up. The patient's good condition may be responsible for this successful outcome.

Atrial Flutter↗

Long-term results of hybrid therapy in patients with atrial fibrillation who develop atrial flutter during flecainide infusion.

The flecainide infusion test has been proposed to screen candidates for hybrid pharmacological and ablation therapy. We report the long-term follow-up of 154 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who developed atrial flutter (AFL) during flecainide infusion (IC AFL), treated with inferior vena cava-tricuspid annulus isthmus catheter ablation and oral flecainide (hybrid therapy). Over a mean of 54.1 +/- 13.1 months 82 patients (53%) remained free of AF and AFL. Flecainide was discontinued because of adverse effects in 6 patients (4%). A history of persistent AF, and the documentation of >/=1 spontaneous AFL episode before the flecainide test were independent predictors of successful hybrid therapy. In patients with paroxysmal AF without documented spontaneous AFL, the long-term efficacy of hybrid therapy was 38.5% (P = 0.03). The flecainide infusion test reliably detects candidates for hybrid therapy. The efficacy of this therapy is maintained over the long-term with a high patient compliance.

Anti-Arrhythmia Agents↗

Primary closed cooled tip ablation of typical atrial flutter in comparison to conventional radiofrequency ablation.

The purpose of this prospective, non-randomized study was to investigate the effectiveness of cooled radiofrequency ablation (cRFA) compared with conventional radio-frequency application (RFA) for ablation of typical atrial flutter (AF). Methods Isthmus ablation was carried out using a system with a circulating fluid path through the ablation tip to control tip temperature in 100 patients with AF. Thirty consecutive AF patients underwent conventional RFA. The number of applications for cRFA was 13.7 +/- 6.9 and for RFA 24.0 +/- 14-5 (P<0.0007) at powers between 35 and 50 W and a tip temperature range of 38-43 degrees C. Ablation duration and fluoroscopy time were 9-9 +/- 4.9 and 22-8 +/- 10.7 min for cRFA, respectively. In contrast, for RFA, ablation duration and fluoroscopy time were 20-6 +/- 14.2 (P<0.0001) and 27.4 +/- 12.7 min, respectively. In 93% of the cooled tip group and in 80% of the control group bi-directional block was confirmed. At 6-months follow-up, recurrence rates were 9 in the cooled-tip group and 7 in the control group, corresponding 10.4% and 25.9%. There were no significant complications. Compared with RFA, cRFA requires lower application numbers. Recurrence rates are low and the overall success rate is high.

Adult↗

Improvement in left ventricular systolic function after successful radiofrequency His bundle ablation for drug refractory, chronic atrial fibrillation and recurrent atrial flutter.

Incessant supraventricular tachyarrhythmia may lead to a reversible impairment of left ventricular (LV) function. This issue was investigated in 10 patients (aged 64 +/- 13 years) who underwent radiofrequency His bundle ablation for control of drug refractory, chronic atrial fibrillation (n = 9) and recurrent atrial flutter (n = 1). LV function was assessed by 2-dimensional guided M-mode echocardiography within 24 hours (baseline) and 49 +/- 18 days (follow-up) after successful ablation, both during VVI pacing at 70 beats/min. Fractional shortening increased from 28 +/- 9% at baseline to 35 +/- 8% at follow-up (p = 0.006). This increase in fractional shortening was due to a significant reduction of end-systolic diameter from 41 +/- 10 to 36 +/- 10 mm (p = 0.02), whereas there was no appreciable change in end-diastolic diameter (56 +/- 7 to 55 +/- 10 mm; p = 0.5). These changes were substantially greater in patients with baseline impairment of LV function (fractional shortening less than 27%). Fractional shortening increased by 12% (p = 0.14) in patients with normal LV function (n = 5) and by 44% (p = 0.02) in those with impaired LV function at baseline (n = 5). The greater increase in fractional shortening in patients with preexisting LV impairment was due to a more pronounced decline in end-systolic dimensions (-11.9%; p = 0.08) compared with that of patients with normal LV function at baseline (-9.21%; p = 0.2). End-diastolic diameter showed no significant change in either group (-3.53% [p = 0.8] and -0.58% [p = 0.4]).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Radiofrequency catheter ablation of Type 1 atrial flutter using a large-tip electrode catheter and high-power radiofrequency energy generator.

Recent studies have demonstrated a high degree of efficacy of 8 mm electrode-tipped or saline-irrigated-tip catheters for ablation of atrial flutter (AFL). These catheters have a theoretical advantage as they produce a large ablation lesion. However, large-tip ablation catheters have a larger surface area and require a higher power radiofrequency (RF) generator with up to 100 W capacity to produce adequate ablation temperatures (50-60 degrees C). The potential advantages of a large-tip ablation catheter and high-power RF generator include the need for fewer energy applications, shorter procedure and fluoroscopy times, and greater efficacy. Therefore, the safety and efficacy of AFL ablation using 8 or 10 mm electrode catheters and a 100-W RF generator was studied using the Boston Scientific, Inc., EPT-1000 XP cardiac ablation system. There were 169 patients, aged 61 +/- 12 years involved. Acute end points were bidirectional isthmus block and no inducible AFL. Following ablation, patients were seen at 1, 3 and 6 months, with event monitoring performed weekly and for any symptoms. Three quality of life surveys were completed during follow-up. Acute success was achieved in 158 patients (93%), with 12 +/- 11 RF energy applications. The efficacy of 8 and 10 mm electrodes did not differ significantly. The number of RF energy applications (10 +/- 8 vs. 14 +/- 8) and ablation time (0.5 +/- 0.4 vs. 0.8 +/- 0.6 h) were less with 10 mm compared with 8 mm electrodes (p < 0.01). Of 158 patients with acute success, 42 were not evaluated at 6 months due to study exclusions. Of the 116 patients evaluated at 6 months, 112 (97%) had no AFL recurrence. Of those without AFL recurrence at 6 months, 95 and 93% were free of symptoms at 12 and 24 months, respectively. Ablation of AFL improved quality of life scores (p < 0.05) and reduced anti-arrhythmic and rate control drug use (p < 0.05). Complications occurred in six out of 169 patients (3.6%) but there were no deaths. It was concluded that ablation of AFL with 8 or 10 mm electrode catheters and a high-power RF generator was safe, effective and improved quality of life. The number and duration of RF applications was lower with 10 mm compared with 8 mm electrode catheters.

Atrial Flutter↗

Successful management of atrial flutter in a newborn with verapamil.

Verapamil has become a popular antiarrhythmic drug for the acute management of supraventricular tachycardia in infants and children. A full-term, 1-hour-old infant presented with supraventricular tachycardia and hypotension that did not respond to vagal maneuvers and direct current cardioversion. After intravenous verapamil, the heart rate slowed and the underlying rhythm was atrial flutter.

Atrial Flutter↗

Case report: severe skin burn at the site of the indifferent electrode after radiofrequency catheter ablation of typical atrial flutter.

Although radiofrequency (RF) catheter ablation has been shown to be an effective treatment strategy in patients with supraventricular tachycardia, RF ablation may lead to potentially serious complications. We describe a case of a 65-year old man who was transferred for catheter ablation of typical atrial flutter. 21 RF applications (mean energy: 81+/-9 watts) were applied in the temperature-controlled mode (70 degrees C) between a 8-mm tip electrode and an indifferent electrode using a high-power RF generator (100 watts) until bi-directional atrial isthmus block was achieved. After the procedure, a third-degree skin burn (10x2 cm) was observed at the lateral edge of the adhesive indifferent electrode whereas the medial edge of the electrode was not fully attached to the skin surface. This case is one out of 1128 ablation procedures (0.09 %) at our institution using a high-power RF generator. The present study demonstrates a severe skin burn induced by mal-attachment of an indifferent electrode during RF ablation. Long RF energy application times, high-power settings, and heavy sedation may have contributed to the observed severity of skin damage.

Aged↗