Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AUSCULTATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Tricuspid regurgitation in children: a pulsed Doppler, contrast echocardiographic and angiographic comparison.

Thirty-one children with congenital heart disease were examined for tricuspid regurgitation by four methods: (1) auscultation, (2) pulsed Doppler echocardiography, (3) saline contrast echocardiography, and (4) right ventricular angiography. Tricuspid regurgitation was detected in three children by auscultation, in 20 by pulsed Doppler echocardiography, in 21 by saline contrast echocardiography, and in 20 by right ventricular angiography. To determine the prevalence of tricuspid regurgitation in children suspected of having congenital heart disease, we reviewed 5417 Doppler echocardiograms performed between 1983 and 1985. Tricuspid regurgitation was detected in 399 of 4670 children (8.5%) with congenital heart disease and in 26 of 106 newborns (25%) with respiratory distress. By comparison, tricuspid regurgitation was detected in only 19 of 641 (3%) normal children. Tricuspid regurgitation is uncommon in normal children, but its incidence in children with congenital heart disease and/or respiratory distress is high.

Adolescent↗

A comparison of two time intervals for the ausculated acceleration test.

OBJECTIVE: Interest in an inexpensive, easy-to-administer antenatal screening test that did not rely on the use of electronic fetal monitoring led to development of the fetoscope administered auscultated acceleration test (AAT) in the late 1980s. More recent efforts have been directed toward providing those who may use the AAT with important information about the most effective and clinically appropriate AAT procedures. The purpose of this study was to determine the screening test validity performance of two AAT time intervals--6 minutes and 10 minutes. METHODS: Two auscultated acceleration tests (AAT6 and AAT10) were simultaneously performed using different time intervals on 205 women with high-risk pregnancies undergoing simultaneous nonstress tests (NSTS) who were referred to a tertiary care unit for antepartum testing. Standard measurements of screening test validity were calculated for each test in the prediction of selected perinatal outcomes. NST findings were included for comparative purposes. RESULTS: The AAT6 yielded an overall higher specificity as compared with the AAT10 at the expense of a slightly lower sensitivity for most perinatal outcomes; these differences were not significant at the .05 level. Relative risk ratios were similar for the AAT6 and AAT10 for both fetal distress and neonatal morbidity, with both AAT being a more effective predictor of neonatal morbidity than for fetal distress. Both tests yielded better sensitivity when compared with NST. CONCLUSIONS: Even though there was a nonsignificant trend toward higher sensitivities and lower specificities for the 10-minute AAT, this study showed that the differences in prediction of perinatal outcomes between the 6-minute and 10-minute AAT were minimal. In view of the added labor required for the 10-minute AAT in the absence of enhanced screening test validity, the 6-minute AAT is clinically preferred. This study has prompted new research questions for the continued development of the AAT as a low-technology fetal assessment technique with potential usefulness by midwives and their colleagues in a variety of settings worldwide.

Female↗

Labor and delivery nurses' attitudes toward intermittent fetal monitoring.

Fetal monitoring is a routine procedure overseen by labor and delivery nurses and upon which they exert considerable influence. There is a discrepancy, however, between the type of fetal monitoring routinely used and the evidence provided by current research and professional organization recommendations. This study provides the first look at labor and delivery nurses' attitudes toward fetal monitoring in more than 20 years. A descriptive, correlational study was conducted at five southeastern Michigan hospitals to evaluate attitudes toward intermittent fetal monitoring and the effect of selected demographic variables on their attitudes. Of the labor and delivery nurses who participated (N = 145), 72.4% agreed that intermittent fetal monitoring should be the standard of care. Although 87% of the respondents stated that they were willing to provide intermittent monitoring, 53.9% indicated that nurse/patient ratios were a problem in providing this service. Nurses' attitudes were significantly influenced by education level (P = .004), and 48% were unsure about current research findings related to intermittent auscultation. Nurses have a positive attitude toward intermittent monitoring, although safe nurse/patient ratios and clear policies need to be addressed. Lack of knowledge regarding the current evidence and other barriers may contribute to intermittent auscultation not being used routinely, despite the fact that its use for women of low obstetrical risk is supported by current research and professional organizations.

Adult↗

Cervical accelerometry in preterm infants.

The objective of this study was to develop a method to use digital signal processing (DSP) technology to describe quantitatively and statistically swallow-associated sounds in preterm infants and to use this method to analyze changes as infants mature. Twelve recordings of accelerometric and physiological data on bottle-feeding preterm infants between 32 and 39 weeks' postmenstrual age (PMA) were analyzed. Cervical auscultation was performed using an accelerometer attached over the larynx. Acoustic data were recorded and graphically displayed using DSP software. Initial discrete sounds (IDSs) were identified and used to construct an average waveform from which a 'variance index' (VI) was calculated for each infant. The shape of the IDS waveforms became progressively more uniform with advancing PMA, as indicated by a significant inverse correlation between VI and PMA (r=0.739; p=0.006). DSP technology facilitated the development of a new method to quantitatively analyze feeding in preterm infants. This method provides an elegant tool to track maturation of infant feeding and assessing feeding readiness. This technique makes the interpretation of cervical auscultation data less subjective by replacing the verbal description of the sounds of feeding with quantitative numeric values. It is anticipated that this method can be automated to facilitate further the analysis of cervical accelerometry data.

Acoustics↗

Clinical test to confirm tracheal intubation: a new method to confirm endotracheal intubation in the absence of capnography.

BACKGROUND AND OBJECTIVE: Advancing an uncut endotracheal tube into the right main bronchus produces unilateral breath sounds. We wanted to test the validity of using this method to distinguish oesophageal from tracheal intubation. METHODS: Forty-two patients were randomized into two groups. The first group was randomized to receive an endotracheal tube that was advanced into the right main bronchus. The second group of patients had their tracheas intubated as normal and then a second endotracheal tube was placed in the oesophagus. Blinded observers were then asked to decide by auscultation if the patients had unilateral breath sounds or not and if they were bronchial and therefore to decide if endotracheal intubation had occurred. RESULTS: Ninety-one per cent of patients (95% CI 0.71-0.99) intubated in the right main bronchus were correctly identified by unilateral breath sounds confirming the usefulness of this test. CONCLUSIONS: Advancing an endotracheal tube into the right main bronchus and auscultation of unilateral breath sounds is a useful way of confirming tracheal intubation.

Adolescent↗

Localization of TMJ sounds to side.

Differential diagnosis depends in cases with disk displacement on accurate identification of sound source. Mistakes may occur when clicking from one temporomandibular joint (TMJ) is heard on both sides of the head at auscultation and neither examiner nor patient, is sure about side. The hypothesis was that the head tissues affect spectral characteristics of TMJ sounds and that differences due to different positioning of sensors can be used in localization of source. The aim was to compare bilateral electronic recordings of unilateral TMJ sounds to obtain and compare attenuation, phase shift and time delay. Recordings were made from 12 subjects with unilateral clicking. Small electret condenser microphones, bandwidth 40-20 000 Hz, were placed at the openings of the auditory canals and the sounds were recorded at a sampling rate of 48 000 Hz. The head tissues acted as a filter causing a frequency dependent attenuation and phase shift. There was a time difference between the ipsi- and the contra lateral recordings, the latter always having a longer delay time (range 0.2-1.2 ms, group mean 0.68 ms, s.d. 0.292 ms). In conclusion, spectral analysis of bilateral electronic TMJ sound recordings is of diagnostic value when bilateral clicking is heard at auscultation and can help to avoid diagnosing a silent joint as clicking.

Adult↗

[Current trends in phonoarthrography].

The detection of sounds from the human body for diagnostic purposes has a long history. In the respiratory and circulatory systems such auscultation is a precise science yielding much useful information. The detection and interpretation of joint sounds, however, has been much less successful in its development. In this paper we outline the history of joint auscultation, of phonoarthrography, and of their modern equivalent: vibration arthrography. The relative merits of acoustic and vibration based systems are discussed and these are illustrated with data from simultaneous recordings of several joint phenomena. Finally, we concluded that the future of phonoarthrography as a clinical test is based on its further development using accelerometers rather than microphones as detectors.

Auscultation↗

Respiratory rates of Indian infants under 2 months of age.

There are few data from developing countries, including India, on the normal range of the respiratory rate (RR) recorded by observation. To determine the normal range of RR in infants up to 8 weeks of age and to define tachypnoea, we studied 100 healthy infants, 50 of normal birthweight and 50 of low birthweight) at 1, 2, 4, 6 and 8 weeks of age. The RR was recorded by observation and auscultation simultaneously for 60 seconds on each visit when the baby was either asleep or awake and content. The median RRs ranged between 42 and 43 breaths/min in infants of normal birthweight and 40 and 44 breaths/min. in low birthweight infants. Inter-age variability up to 8 weeks of age was very slight and statistically insignificant. Only 2-10% of the infants at any given age had a RR > or = 60/min. At all ages, RR by observation was higher than that by auscultation (p < 0.001). Neither birthweight nor gender significantly influenced the RR. When awake, infants had significantly higher RRs than when asleep. The RR extrapolated from a 15-second breath count was significantly lower (p < 0.05-0.01), whereas results from 30-second counts were similar to 60-second counts. Our data endorse the use of a RR > or = 60 breaths/min. counted for 1 minute as a cut-off to define tachypnoea in infants < 2 months of age.

Auscultation↗

Measurement of arterial closing pressure.

It has been suggested that certain artifacts in blood pressure measurement by auscultation stem from stiffness of the tissues underneath the pressure cuff, resulting in a component of cuff pressure being required to overcome resistance to brachial artery collapse. This paper describes a technique for measuring the pressure required to collapse a segment of the brachial artery which has been isolated from central arterial pressure. This measurement is termed the arterial closing pressure. In a study of eleven elderly subjects, the artery collapsed spontaneously (zero closing pressure) after being isolated from central pressure in seven subjects. The remaining four required external pressures ranging from 4.6 to 10.7 kPa (35 to 81 mmHg) in order to collapse the artery. Thus arterial closing pressure may frequently be a significant fraction of arterial blood pressure in the elderly population, and may contribute to error in the measurement of blood pressure by auscultation. Arterial closing pressure may be a useful tool for investigating the origin of differences between indirect and direct blood pressure measurements, and also in the investigation of spontaneous arterial closure.

Aged↗

Effectiveness of telemedicine in the outpatient pulmonary clinic.

BACKGROUND: Over the past several years, there has been a resurgence of interest in telemedicine. Despite this renewed interest, some health care providers remain skeptical regarding the effectiveness of telemedicine for the delivery of health care. OBJECTIVE: The objective of this prospective, crossover study was to determine if there was any difference between care delivered using video conferencing-based telemedicine technology and that given by a traditional face-to-face encounter in a pulmonary medicine clinic. METHODS: Two pulmonologists sequentially examined 40 individuals via video conferencing-based telemedicine technology and by the traditional face-to-face method. Two additional pulmonologists, in a blinded fashion, compared the results for consistency in the history, examination with focus on auscultation of the lungs, diagnostic impression, and evaluation and treatment plans. RESULTS: Evaluation of patients by telemedicine was as effective as the traditional mode. The telemedicine physician and the physician examining the patient in the traditional manner were able to elicit the same key complaints and hear the same adventitious sounds on auscultation of the lungs. CONCLUSION: Telemedicine can enable the provision of high-quality care in a pulmonary clinic setting.

Adult↗

Effect of positioning on recorded lung sound intensities in subjects without pulmonary dysfunction.

BACKGROUND AND PURPOSE: Physical therapists often use positioning to assist in the reexpansion of collapsed lung segments. An increase in lung sound intensity on auscultation is considered indicative of lung expansion. This study was designed to examine whether clinical interpretation of auscultatory findings is warranted. SUBJECTS: The subjects (5 male, 6 female) were young physical therapist students without pulmonary dysfunction (mean age=20.4 years, mean height=166.3 cm, mean weight=57.5 kg). Subjects with lung disease were excluded because pulmonary pathology is difficult to standardize. METHODS: Lung sounds electronically recorded over the posterior chest wall of subjects in sitting and side-lying positions were compared. Measures included peak intensity, frequency at maximum power, and median frequency. RESULTS: In the sitting position, inspiratory sounds recorded over the left posterior chest wall were louder than those recorded on the right side. In the side-lying positions, the sound intensity recorded from the dependent chest wall was louder than that recorded from the nondependent chest wall. In side-lying positions, the upper hemithorax is "nondependent," and the side in contact with the bed is "dependent." Sound intensities recorded over both posterior chest walls in the sitting position were louder than those recorded over the same lung area in the nondependent side-lying position. There was no difference in the sound intensity recorded between the sitting and dependent side-lying postures. CONCLUSION AND DISCUSSION: When comparative auscultation of the chest wall is used by physical therapists to assess the adequacy of pulmonary ventilation, patient posture and regional differences in breath sound intensity can influence clinical interpretation.

Adult↗

The effect of halothane on the amplitude and frequency characteristics of heart sounds in children.

UNLABELLED: Although continuous auscultation has been used during surgery as a monitor of cardiac function for many years, the effect of anesthetics on heart sounds has never been quantified. We determined the root mean squared amplitude and frequency characteristics (peak frequency, spectral edge, and power ratios) of the first (S1) and second (S2) heart sounds in 19 healthy children during induction of anesthesia with halothane. In all patients, halothane decreased the amplitude of S1 (R2 = 0.87 +/- 0.12) and S2 (R2 = 0.66 +/- 0.33) and the high-frequency components (>80 Hz) of these sounds. These changes were clearly audible and preceded decreases in heart rate and blood pressure. The spectral edge decreased for S1 in 18 patients (R2 = 0.73 +/- 0.24) and for S2 in 13 patients (R2 = 0.58 +/- 0.25). Peak frequency did not change. The rapidity with which myocardial depression and its associated changes in heart sound characteristics occurred confirms that continuous auscultation of heart sounds is a useful clinical tool for hemodynamic monitoring of anesthetized infants and children. IMPLICATIONS: Heart sound characteristics can be used to monitor cardiac function during halothane anesthesia in children. The changes occur rapidly and precede noticeable changes in heart rate and blood pressure.

Age Factors↗

What is known about methods of correctly placing gastric tubes in adults and children.

An abdominal radiograph is considered the "gold standard" for determining the position of flexible small-bore nasogastric/orogastric tubes. However, placement must be checked frequently while a tube is in place, and the summative radiation risk of multiple radiographs, as well as their expense, make the development of adequate bedside placement-locating methods imperative. Several methods of detecting tube placement have been investigated in adults, including: aspirating gastric contents and measuring the pH, bilirubin, pepsin, and trypsin levels; examining the visual characteristics of aspirate; placing the proximal end of the tube under water and observing for bubbles in synchrony with expirations; measuring the carbon dioxide level at the proximal end of the nasogastric/orogastric tube; auscultation for a gurgling sound over the epigastrium or left upper quadrant of the abdomen; and measuring the length from the nose/mouth to the proximal end of the tube. Many researchers have already concluded simple auscultation is not a reliable method to assess tube position because injection of air into the tracheobronchial tree or into the pleural space can produce a sound indistinguishable from that produced by injecting air into the gastrointestinal tract. In adults, only pH and bilirubin of aspirate have been shown both to reliably predict tube position and to have inexpensive simple bedside tests. In children, only pH of aspirate has been shown to be reliable. Research on gastric tube placement in children is relatively new because children are challenging to study in that they are considered a vulnerable population. This review of the literature includes results of both adult and pediatric studies. Tube placement error rates varied from 1.9% to 89.5% in adults and between 20.9% and 43.5% in children.

Adult↗

Historical controversy in health technology assessment: the case of electronic fetal monitoring.

Electronic fetal monitoring (EFM) was introduced in the late 1950s as an alternative to traditional auscultation by stethoscope or fetoscope in the management of labor and delivery. The new technology was seen as a valuable tool in the prevention of cerebral palsy and other adverse fetal outcomes and diffused rapidly into clinical practice. In the late 1970s, some scepticism began to be voiced about the evidence for the effectiveness of EFM. The authors published a systematic review of the evidence in 1979 that concluded that there was insufficient evidence for the effectiveness of the routine use of EFM and a clear rise in the cesarean delivery rate associated with its use. The analysis was based on a thorough review of approximately 600 books and articles, but focused heavily on the evidence of four randomized clinical trials (RCTs) that had been published. An economic analysis further underscored the importance of this issue. The report was met with harsh ad hominem criticism from clinicians both in public venues and in the medical literature. Subsequently, additional RCTs were conducted and other analyzes were published, and in 1987 the American College of Obstetricians and Gynecologists recommended that auscultation was an acceptable alternative to EFM in routine labor and delivery. Yet, today EFM continues to be the standard of practice, used in 80% of labors in this country. The most important conclusion drawn from this experience is the need to evaluate new technologies before their widespread diffusion into clinical practice.

Attitude of Health Personnel↗

Hemodynamic correlates of the third heart sound and systolic time intervals.

Bedside diagnostic tools remain important in the care of patients with heart failure. Over the past two centuries, cardiac auscultation and phonocardiography have been essential in understanding cardiac pathophysiology and caring for patients with heart disease. Diastolic heart sounds (S3 and S4) and systolic time intervals have been particularly useful in this regard. Unfortunately, auscultation skills have declined considerably, and systolic time intervals have traditionally required carotid pulse tracings. Newer technology allows the automated detection of heart sounds and measurement of systolic time intervals in a simple, inexpensive, noninvasive system. Using the newer system, the authors present data on the hemodynamic correlates of the S3 and abnormal systolic time intervals. These data serve as the foundation for using the system to better understand the test characteristics and pathophysiology of the S3 and systolic time intervals, and help to define their use in improving the bedside diagnosis and management of patients with heart failure.

Female↗

Air embolism in hip surgery.

The hearts of 49 patients undergoing hip-replacement surgery were auscultated and the characteristic sounds of air emboli were heard in 15 of them--30% of the total. This finding was confirmed in the later patients by the use of an ultrasonic transducer to detect air emboli. Routine auscultation of the heart during the insertion of acrylic bone cement and prosthesis is recommended.

Aged↗

Assessing the position of the tracheal tube. The reliability of different methods.

Various methods have been developed to confirm proper intubation of the trachea. This blind, randomised study evaluates some of these quantitatively and qualitatively. Forty patients had both their trachea and oesophagus intubated. A procedure that included auscultation of the upper abdomen and lungs was 100% reliable independent of which tube was ventilated. Auscultation of the lungs resulted in a wrong conclusion in 15% (6-30, 95% confidence limits) of the cases when the oesophagus was ventilated: the sounds were misinterpretated as normal breath sounds. Suction on the tubes with a 60-ml syringe was also a reliable test. Other methods assessed were observation for condensation of water vapor, and abnormal movements of the upper abdomen; these were unreliable.

Anesthesia, General↗

Pre-operative detection of valvular heart disease by anaesthetists.

We prospectively estimated the prevalence of heart murmurs in 2522 consecutive adult non-cardiac surgery patients during pre-operative evaluation. Factors that contribute to the detection of a heart murmur were identified, and echocardiography was used to evaluate to what extent a murmur reflected presence of valvular heart disease. A cardiac murmur was detected in 106 patients (prevalence 4.2%, 95% CI: 3.5-5.1%). Multivariable logistic regression analyses showed that age and general physical impression were independently associated with detecting a murmur (p-values < 0.01). In 83 (79%) of the patients with a murmur, an echocardiographic diagnosis was available: 39% had aortic valve abnormalities, 24% had mitral valve regurgitation, 7% had other valvular heart disease and 30% did not have any abnormality. Thus, 58 of the 83 patients had valvular heart disease (positive predictive value using routine cardiac auscultation for diagnosing VHD: 70%, 95% CI: 59-79%). Murmurs in patients younger than 40 years never reflected valvular heart disease. Pre-operative cardiac auscultation seems only reasonable in patients aged 40 years or older. Subsequent echocardiography in these selected patients is necessary.

Adult↗