Total hip arthroplasty performed with insertion of the femoral component with cement and the acetabular component without cement. Ten to thirteen-year results.

Fifty-two consecutive primary total hip arthroplasties were performed in forty-seven unselected patients by one surgeon. The prosthesis included a hemispherical porous-coated acetabular component, inserted without cement and with the use of screws through three peripheral flanges, and a femoral component, inserted with a so-called second-generation cementing technique. No patient was lost to radiographic follow-up, and the clinical result was known for all patients. The average age at the time of the index operation was fifty-seven years (range, twenty-nine to seventy-nine years). Four patients (four hips) who died were last examined less than ten years postoperatively (the minimum follow-up period for this study) and one hip was revised, leaving forty-seven non-revised hips in forty-two surviving patients who were followed for at least ten years. The duration of clinical follow-up of these forty-two patients averaged 12.3 years (range, 10.8 to 13.3 years), and the duration of radiographic follow-up averaged 12.1 years (range, 10.0 to 13.0 years). One (2 per cent) of the original fifty-two hips was revised for late recurrent dislocation, without loosening, 9.7 years after the index arthroplasty. The rate of dislocation was relatively high (13 per cent; seven hips), and we believed it to be related to the shallow-chamfer acetabular design combined with the small femoral head. At the time of the latest follow-up, no femoral component was loose. One (2 per cent) of the fifty-two acetabular components was loose according to radiographic criteria, but the hip functioned well (Harris hip score, 94 points) 12.4 years after the index arthroplasty. Pelvic osteolysis developed in one hip (2 per cent); femoral osteolysis, in eight (15 per cent); and distal femoral osteolysis, in three (6 per cent). The average Harris hip score for the forty-seven non-revised hips increased from 48 points (range, 26 to 63 points) preoperatively to 89 points (range, 67 to 100 points) at the time of the most recent follow-up. Forty (85 per cent) of the forty-seven hips had a good or excellent result, whereas five (11 per cent) had a fair result (score, 74 to 79 points) and two (4 per cent) had a poor result (score, 67 and 69 points). The hybrid primary total hip arthroplasty resulted in very good clinical function at ten to thirteen years, although the rate of dislocation was high.

Acetabulum↗

Total hip arthroplasty with porous-coated prostheses fixed without cement in patients who are sixty-five years of age or older.

We reviewed the results of 212 total hip arthroplasties performed without cement in 203 unselected, consecutive patients who were sixty-five years of age or older. The outcome was known for 196 hips, thirty-seven of which had been followed until the death of the patient and 159 of which had been followed for a minimum of five years. A reoperation was done in 4 percent (seven) of the 196 hips. These reoperations included one revision because of loosening of the stem and five revisions of the cup. Three of the acetabular revisions were done because of fracture due to polyethylene wear; one, because of recurrent dislocation; and one, because of polyethylene wear and a fracture due to lysis. In the seventh reoperation, a cup and stem were exchanged because of infection. The probability that a hip prosthesis would survive twelve years without a reoperation was 0.92 (95 percent confidence interval, 0.85 to 0.99). We evaluated the clinical results for 152 patients who had not had a reoperation and had been followed for at least five years (mean, 8.5 years; range, five to fourteen years). Of these patients, thirteen (9 percent) had pain that limited activity: five (3 percent) had pain in the thigh (four patients) or groin (one patient), and eight (5 percent) had trochanteric pain and tenderness. One hundred and forty-four (95 percent) of the patients noted an improvement in overall function, and 149 (98 percent) reported satisfaction with the outcome. One hundred and thirty-five hips that were not revised were followed radiographically for at least five years (mean, 8.2 years; range, five to fourteen years). In this group, osteolysis was observed in three hips (2 percent); loosening of the cup, in three (2 percent); and loosening of the stem, in one (1 percent). Stress-shielding was seen on the two-year postoperative radiographs of forty-five (26 percent) of the 174 hips that were followed for at least that duration. The prevalence of osteolysis, loosening of a component, and reoperations was no greater in this subgroup than in the overall group. These results indicate that total hip arthroplasty without cement can be successful in older patients. This study also provides a reference for comparison with the results of total hip arthroplasty performed with cement and those of so-called hybrid total hip arthroplasty (an acetabular component fixed without cement and a femoral component fixed with cement) in patients who are sixty-five years of age or older.

Aged↗

Prospective analysis of preoperative and intraoperative investigations for the diagnosis of infection at the sites of two hundred and two revision total hip arthroplasties.

BACKGROUND: Total hip arthroplasty is a commonly performed procedure in the United States and Canada that is associated with a definite risk of postoperative infection. Moreover, diagnosing an infection after total hip arthroplasty can present a challenge as there are no preoperative tests that are consistently sensitive and specific for infection in patients who need a revision arthroplasty. The present prospective study was performed to evaluate a variety of investigations for the diagnosis of infection at the site of a previous arthroplasty in order to determine if any combination of diagnostic studies could be used to determine which patients are at risk for a postoperative wound infection. METHODS: We prospectively analyzed the preoperative and intraoperative investigations used for the diagnosis of infection in 178 patients who had a total of 202 revision hip replacements. Clinical data were collected preoperatively. Investigations to determine the presence or absence of infection included a white blood-cell count, measurement of the erythrocyte sedimentation rate, measurement of the level of C-reactive protein, preoperative aspiration of the joint, intraoperative gram-staining and culture of periprosthetic tissue, a white blood-cell count in synovial fluid, and examination of intraoperative frozen sections. Frozen sections were analyzed in a blinded fashion without knowledge of clinical or laboratory data. Patients receiving antibiotics at the time of aspiration or collection of specimens for intraoperative culture were excluded from the analysis of those investigations, regardless of the results of the cultures. A positive result (suggestive of infection) was clearly defined for each of the investigations. RESULTS: Thirty-five hips (17 percent) were determined to be infected on the basis of clinical findings and positive results, according to the defined criteria, of investigations. With inflammatory conditions excluded, the sensitivity, specificity, positive predictive value, and negative predictive value were 0.82, 0.85, 0.58, and 0.95, respectively, for the erythrocyte sedimentation rate and 0.96, 0.92, 0.74, and 0.99, respectively, for the level of C-reactive protein. All patients who had a periprosthetic infection had an elevated erythrocyte sedimentation rate or level of C-reactive protein, but not always both. When patients who were receiving antibiotics were excluded, the results of aspiration of the joint were 0.86 for sensitivity, 0.94 for specificity, 0.67 for the positive predictive value, and 0.98 for the negative predictive value. Intraoperative studies revealed sensitivities, specificities, positive predictive values, and negative predictive values of 0.19, 0.98, 0.63, and 0.89, respectively, for gram-staining of specimens of the most inflamed-appearing tissue; 0.36, 0.99, 0.91, and 0.90, respectively, for the white bloodcell count in synovial fluid; and 0.89, 0.85, 0.52, and 0.98, respectively, for a neutrophil count in synovial fluid of more than 80 percent. The sensitivity, specificity, positive predictive value, and negative predictive value were 0.80, 0.94, 0.74, and 0.96, respectively, for the frozen sections and 0.94, 0.97, 0.77, and 0.99, respectively, for the intraoperative cultures. CONCLUSIONS: The combination of a normal erythrocyte sedimentation rate and C-reactive protein level is reliable for predicting the absence of infection. Aspiration should be used when the erythrocyte sedimentation rate or the C-reactive protein level is elevated or when a clinical suspicion of infection remains. We found the gram stain to be unreliable. Examination of intraoperative frozen sections is useful in equivocal cases or when hematological markers may be falsely elevated because of an inflammatory or other condition.

Aged↗

The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee arthroplasty. A prospective, randomized, multicenter study.

BACKGROUND: Total knee arthroplasty is associated with major postoperative blood loss of approximately 800 to 1200 milliliters, and blood transfusion is frequently required. With the increased concern about the risks of blood transfusion, various methods of blood conservation in orthopaedic surgery have been studied. The most appropriate solution, however, is to reduce the loss of blood during and after an operation. The present prospective, controlled, randomized study was designed to evaluate the hemostatic efficacy of the use of fibrin tissue adhesive in patients managed with total knee arthroplasty. METHODS: Fifty-eight patients who were scheduled to have a total knee arthroplasty were randomly divided into two groups: a control group, in which the standard means of hemostasis were applied, and a treatment group, in which the standard means to control local bleeding were applied and a fibrin tissue adhesive was sprayed on the internal aspects of the operative field before skin closure. All operations were performed in a bloodless field with use of a pneumatic tourniquet. All patients received low-molecular-weight heparin as thromboprophylaxis twelve hours before the operation and every twelve hours postoperatively. Blood loss during the operation was evaluated by measuring the volume in the suction apparatus and by estimating the amount of lost blood in the swabs at the end of the operation. The apparent postoperative lost blood was determined by measuring the volume in the suction-drain bottles. All blood transfusions were recorded. RESULTS: The mean apparent postoperative blood loss (and standard deviation) in the fibrin-tissue-adhesive group was 360+/-287.7 milliliters compared with 878+/-403.0 milliliters in the control group, with a mean difference of 518 milliliters (p<0.001). The decrease in the level of hemoglobin was 25+/-10 grams per liter in the treatment group compared with 37+/-12 grams per liter in the control group (p<0.001). Sixteen patients (55 percent) in the control group required a blood transfusion and eight (28 percent) required two units of blood, whereas only five (17 percent) of the patients in the fibrin-tissue-adhesive group required a blood transfusion and only one (3 percent) required two units (p = 0.004). The number of adverse events was comparable between the two groups. None of the adverse events were considered to be related to the use of fibrin tissue adhesive. One death, which was due to massive pulmonary embolism, was reported in the control group. No seroconversion was reported at three and six months after the operation. CONCLUSION: The use of fibrin tissue adhesive in total knee arthroplasty seems to be an effective and safe means with which to reduce blood loss and blood-transfusion requirements. Furthermore, the importance of these findings was enhanced by a significant reduction in blood loss, in the postoperative decrease in the level of hemoglobin, and in blood-transfusion requirements despite preoperative thromboprophylaxis with low-molecular-weight heparin.

Aged↗

Pelvic discontinuity in revision total hip arthroplasty.

BACKGROUND: Pelvic discontinuity is a distinct form of bone loss, occurring in association with total hip arthroplasty, in which the superior aspect of the pelvis is separated from the inferior aspect because of bone loss or a fracture through the acetabulum. The purpose of this study was to describe the population of patients who are at risk for this condition, to identify the characteristic radiographic features associated with it, and to report the results of revision total hip arthroplasty for the treatment of pelvic discontinuity. METHODS: The cases of all twenty-seven patients (thirty-one hips) who were identified as having a pelvic discontinuity at the time of a reoperation for a failed hip arthroplasty at one institution were reviewed retrospectively, and demographic information was collected. The preoperative radiographs and the operative notes were reviewed, and the postoperative results and complications were recorded. RESULTS: Pelvic discontinuity was identified in association with thirty-one (0.9 percent) of 3505 acetabular revisions. The mean age of the patients was sixty-one years (range, thirty-eight to eighty years). Twenty-eight hips were in women, and three were in men. Women (p < 0.001) and patients who had rheumatoid arthritis (p = 0.003) had a significantly increased risk of pelvic discontinuity. The radiographic findings included a visible fracture line through the anterior and posterior columns, medial translation of the inferior aspect of the hemipelvis relative to the superior aspect (seen as a break in Kohler's line), and rotation of the inferior aspect of the hemipelvis relative to the superior aspect (seen as asymmetry of the obturator rings) on a true anteroposterior radiograph. Two patients died within two years after the revision, and two had a resection arthroplasty for the treatment of the pelvic discontinuity; thus, twenty-seven hips were reconstructed and were eligible for follow-up at least two years after the operation. A number of different methods were used for reconstruction, but the results were best in patients who did not have severe segmental acetabular bone loss (type IVa [a satisfactory result in three of three hips]) and poorer in those who had severe segmental or combined segmental and cavitary bone loss (type IVb [a satisfactory result in ten of nineteen hips]) and in those who previously had been treated with irradiation to the pelvis (type IVc [a satisfactory result in three of five hips]). Nine of the twenty-seven hips needed another operation: four, because of aseptic loosening of the acetabular component; four, because of recurrent dislocation; and one, because of deep infection. Excluding three hips that were revised early because of infection or dislocation, a mechanically stable construct (that is, a stable socket and a possibly or definitely healed discontinuity) was obtained in seventeen of twenty-four hips. CONCLUSIONS: Pelvic discontinuity is uncommon, and treatment is associated with a high rate of complications. For hips with type-IVa bone loss and selected hips with type-IVb defects, in which a socket inserted without cement can be satisfactorily supported by native bone, we prefer to use a posterior column plate to stabilize the pelvis and a porous-coated socket inserted without cement. For most hips with type-IVb and type-IVc bone loss, we prefer to use particulate bone graft or a single structural bone graft protected with an antiprotrusion cage.

Acetabulum↗

Primary total hip arthroplasty with use of the modular S-ROM prosthesis. Four to seven-year clinical and radiographic results.

BACKGROUND: A multicenter retrospective study was conducted to determine the clinical and radiographic results of primary total hip arthroplasty with insertion of the S-ROM modular femoral stem without cement in a series of patients who had been followed for four to seven years. Four centers participated in the study, with one contributing surgeon at each center. METHODS: Two hundred and eight consecutive patients who had a total hip arthroplasty with implantation of the S-ROM femoral prosthesis at one of the four centers during the study period were identified. Twenty-nine patients were lost to follow-up or had incomplete radiographic data, and twenty patients died from causes unrelated to the index arthroplasty. The remaining 159 patients formed the basis of this study. Sixteen of these patients had a bilateral procedure, resulting in 175 hips with complete clinical and radiographic data. The average age of the patients at the time of the index operation was fifty-nine years (range, twenty-two to ninety-three years). The duration of clinical follow-up averaged 5.3 years (range, four to 7.8 years), and the duration of radiographic follow-up averaged 4.9 years (range, four to 7.3 years). RESULTS: One patient (0.6 percent) had a failed femoral component, which was evidenced by progressive subsidence and lack of bone ingrowth. In addition, two patients (1 percent) had a revision of the acetabular component. The average Harris hip score increased from 35 points (range, 10 to 76 points) preoperatively to 91 points (range, 52 to 100 points) at the most recent follow-up examination. The radiographic evaluation revealed that 172 hips (98 percent) had stable bone ingrowth, two hips (1 percent) had stable fibrous ingrowth, and one hip (0.6 percent) had unstable fibrous ingrowth. Periprosthetic osteolytic lesions were noted in twelve hips (7 percent). The lesions were observed in the femur in eight hips, in the acetabulum in two hips, and in both the femur and the acetabulum in two hips. All femoral osteolytic lesions were localized within the greater trochanter or the proximal-medial portion of the femoral neck. No osteolytic lesions were evident distal to the stem-sleeve junction. CONCLUSIONS: Use of the modular S-ROM femoral prosthesis yielded excellent intermediate-term outcomes with respect to standard radiographic and clinical criteria. The issue regarding the theoretical increase in the rate of osteolysis due to metal debris generated at the modular femoral stem-sleeve junction was specifically addressed. We found that the rate of osteolysis in this series was not notably higher than that in other series reported in the orthopaedic literature. Although many possible factors may influence the rate of osteolysis in total hip arthroplasty, this finding suggests that the potential increase in osteolysis theoretically associated with this modular femoral implant was not observed at intermediate-term follow-up. Although longer follow-up is warranted so that the potential for osteolysis can be evaluated fully, no osteolytic lesions were evident distal to the stem-sleeve interface at the time of intermediate-term follow-up. This finding suggests that there is a circumferential seal at the modular junction of the stem that prevents the distal egress of wear debris.

Adult↗

Charnley total hip arthroplasty with cement. Minimum twenty-five-year follow-up.

BACKGROUND: This report presents the results of the senior author's initial twenty-five-year experience with the use of Charnley total hip arthroplasty with cement. The purpose of this paper was to evaluate the long-term results of total hip arthroplasty. METHODS: Between July 1970 and April 1972, the senior author (R. C. J.) performed 330 Charnley total hip replacements with cement using a hand-packing cement technique in 262 patients. Fifty-one patients (sixty-two hips) who were alive at least twenty-five years post-operatively were evaluated from a clinical standpoint with use of a standard-terminology questionnaire. The average age of this group at the time of surgery was fifty-six years (range, thirty-five to seventy-one years) compared with sixty-five years (range, twenty-one to eighty-nine years) for the entire group. All patients were evaluated for radiographic changes at the time of their most recent follow-up. Of the fifty-one patients (sixty-two hips) who were alive at least twenty-five years postoperatively, thirty-one (thirty-six hips) had a follow-up radiograph made at a minimum of twenty-five years after the surgery. The average duration of radiographic follow-up for the fifty-one patients was 22.7 years (range, two to twenty-seven years). RESULTS: Of the sixty-two hips in the fifty-one patients who were alive at least twenty-five years postoperatively, fourteen (23 percent) had been revised. Three (5 percent) had the revision because of loosening with infection; eleven (18 percent), because of aseptic loosening; and none, because of dislocation. The prevalence of revision due to aseptic loosening of the acetabular component in all 316 hips (excluding those that were lost to follow-up or that were revised for infection or dislocation) was 6 percent (eighteen hips), whereas the prevalence in the fifty-nine hips (excluding the three revised for infection) in the patients who were alive at least twenty-five years after the arthroplasty was 15 percent (nine hips). The prevalence of revision because of aseptic loosening of the femoral component in all 316 hips was 3 percent (nine hips), and the prevalence in the fifty-nine hips in the living patients was 7 percent (four hips). In the group of living patients, osteolysis occurred in Gruen zone 1 or 7 in thirty-three hips and in Gruen zones 2 through 6 in two hips. Ballooning acetabular osteolysis occurred in five hips. Of the 327 hips for which the outcome was known after a minimum of twenty-five years, 295 (90 percent) had retained the original implants until the patient died or until the most recent follow-up examination. Of the sixty-two hips in patients who lived for at least twenty-five years after the surgery, forty-eight (77 percent) had retained the original prosthesis. CONCLUSIONS: Our follow-up study at twenty-five years following Charnley total hip arthroplasty with cement demonstrates the durability of the results of the procedure. These results should provide a means for comparison with the results of newer cementing techniques as well as those associated with newer cemented and cementless hip designs.

Aged↗

The reliability and validity of the self-reported patient-specific index for total hip arthroplasty.

BACKGROUND: The Patient-Specific Index is unique in that it reflects how individual patients weigh concerns in rating the outcome of total hip arthroplasty. The Patient-Specific Index was originally administered by an interviewer, which is not always feasible and can be costly. The purposes of the present study were (1) to create a self-reported version of the Patient-Specific Index, (2) to determine the reliability of this new self-reported version, and (3) to determine the relationship between the scores on the new self-reported version and those on the original interviewer-administered version. METHODS: A self-reported version of the Patient-Specific Index was developed, and a pilot test was performed on ten patients. Patients who were scheduled for a total hip arthroplasty or who had recently had a total hip arthroplasty were eligible for the reliability and validity testing. A copy of the new self-reported Patient-Specific Index was mailed to the patients, and they completed it independently. The patients' ratings of the importance and severity of twenty-four concerns prior to total hip arthroplasty were added together to create a summary Patient-Specific Index score. To determine test-retest reliability, patients completed the self-reported Patient-Specific Index a second time, two weeks later. To determine criterion validity, participants also completed the interviewer-administered Patient-Specific Index. RESULTS: Fifty-five patients completed the study. The random-effects intraclass correlation test-retest coefficient was 0.79 (greater than 0.75 represents excellent reliability). The mean Patient-Specific Index scores on the self-reported version and on the interviewer-administered version were 173 and 165 points, respectively (Student t test, p = 0.45). The self-reported Patient-Specific Index was concordant with the interviewer-administered Patient-Specific Index (intraclass correlation coefficient, 0.78). CONCLUSIONS: We concluded that a self-reported version of the Patient-Specific Index, which focuses on the concerns of individuals, is reliable and has criterion validity compared with an interviewer-administered version.

Activities of Daily Living↗

Acetabular revision after failed total hip arthroplasty in patients with congenital hip dislocation and dysplasia. Results after a mean of 8.6 years.

BACKGROUND: Revision of a total hip arthroplasty in a patient who has had congenital hip dysplasia or dislocation is often more difficult than a standard revision operation. The purpose of this study was to assess the efficacy and complications of use of a cementless hemispherical acetabular component for revision of an acetabular component of a failed total hip replacement in patients whose initial problem was arthritis secondary to congenital dislocation or dysplasia. The mean duration of follow-up was approximately eight years. METHODS: We reviewed a consecutive series of sixty-one hips in fifty-three patients who underwent a cementless acetabular revision with use of a hemispherical acetabular component, with or without concurrent femoral revision. Data were collected prospectively. The mean age of the patients at the time of the index operation was fifty-six years. A mean of 1.9 ipsilateral hip operations had been performed previously. Thirty-nine hips (64 percent) had a so-called high hip center prior to the index revision. With one exception, the uncemented acetabular component was fixed with screws. Fifty-one acetabular components were placed with so-called line-to-line fit, and ten were oversized by one to three millimeters. In thirty-eight hips, the femoral component was revised as well. Twenty-nine femora were reconstructed with use of a cemented device, and nine were revised with an uncemented patch-porous-coated femoral stem (a stem on which the porous coating appears in patches). RESULTS: Four patients (five hips) died prior to the five-year minimum follow-up interval. With the exception of one hip treated with resection arthroplasty because of deep infection, none of the hips in these deceased patients had been revised or had a loose component. One living patient (one hip) had a resection arthroplasty, and one additional patient (two hips) had both stable acetabular components rerevised at the time of femoral rerevision at another institution because of loosening and osteolysis. One patient refused to return for follow-up, but the components had not been revised. The remaining fifty-two hips in forty-six patients were followed for a mean of 8.6 years (range, 5.0 to 12.7 years). The mean Harris hip score was 80 points (range, 56 to 100 points) at the time of the latest follow-up. No acetabular component had been revised, although two had migrated. No other acetabular component was loose according to our radiographic criteria. Thus, the mechanical failure rate on the acetabular side was 3 percent (two of sixty-one) for the entire series and 4 percent (two of fifty-two) for the patients who had been followed for a mean of 8.6 years. On the femoral side, the mechanical failure rate was 3 percent (one of twenty-nine) for the cemented stems and six of nine for the uncemented patch-porous-coated stems. CONCLUSIONS: Of the approaches used in this difficult series of patients requiring revision, the hybrid arthroplasty (a cementless acetabular component and a cemented femoral component) yielded overall good results after an intermediate duration of follow-up.

Acetabulum↗

A randomized trial of controlled-release oxycodone during inpatient rehabilitation following unilateral total knee arthroplasty.

BACKGROUND: Reliance on "as-needed" analgesia following total knee arthroplasty may lead to inadequate control of pain and delayed recovery of function. Preemptive use of controlled-release opioids may improve pain control, accelerate recovery, and reduce the need for inpatient rehabilitative services. This study was designed to determine whether controlled-release opioids enhance post-arthroplasty pain control and facilitate functional recovery during rehabilitation. METHODS: Fifty-nine patients admitted for inpatient rehabilitation following unilateral total knee arthroplasty were randomized to receive OxyContin (controlled-release oxycodone) (twenty-nine patients) or a placebo (thirty patients) every twelve hours. Both groups could receive on-request, immediate-release oxycodone (5 mg every four hours). The dose of study medication was increased on the basis of the frequency of requests for immediate-release oxycodone. Measures of interest included pain ratings as determined with a visual-analog scale, changes in the range of motion of the knee and quadriceps strength, and improvements in selected Functional Independence Measure scores during the first eight physical therapy sessions. The duration of the hospital stay for rehabilitation also was compared between the two groups. RESULTS: Baseline demographic, clinical, and functional characteristics were similar between the OxyContin and placebo groups. Compared with the placebo group, the patients who received OxyContin reported significantly less pain as well as significantly greater range of motion of the knee (passive motion, p = 0.036; active motion, p< 0.001) and quadriceps strength (p = 0.001) by the eighth physical therapy session. The patients who received OxyContin also were discharged from the rehabilitation hospital at an average of 2.3 days earlier than the patients in the placebo group (p = 0.013). CONCLUSIONS: Preemptive use of controlled-release oxycodone during rehabilitation following total knee arthroplasty leads to improved pain control, more rapid functional recovery, and a reduced need for inpatient rehabilitative services.

Aged↗

Posterior cruciate ligament-retaining total knee arthroplasty in patients with rheumatoid arthritis.

BACKGROUND: Although initial reports on posterior cruciate ligament-retaining total knee arthroplasty in patients with rheumatoid arthritis have been encouraging, a high rate of late instability necessitating revision has been reported recently. The purpose of the present prospective study was to analyze the results of posterior cruciate ligament-retaining total knee arthroplasty in patients with rheumatoid arthritis. METHODS: Seventy-two posterior cruciate ligament-retaining total knee arthroplasties in fifty-one patients with rheumatoid arthritis were studied prospectively. All procedures were performed with the Miller-Galante I prosthesis. Eighteen patients (twenty-four knees) died before the eight-year follow-up and one patient (two knees) was lost to follow-up, leaving forty-six knees (thirty-two patients) for review. These forty-six knees were evaluated clinically (with particular attention to posterior instability) and radiographically at annual intervals for a mean of 10.5 years (range, eight to fourteen years). RESULTS: Forty-four (95%) of forty-six knees had a good or excellent result at a mean of 10.5 years. However, nine (13%) of the original seventy-two knees had revision of the implant, with six of the revisions performed because of failure of a metal-backed patellar component. The rate of survival at ten years was 93% 4% with femoral or tibial revision for any reason as the end point and 81% 5% with any reoperation as the end point. There was no aseptic loosening in any knee. Posterior instability was identified clinically and/or radiographically in two (2.8%) of the original seventy-two knees; both unstable knees were in the same patient. CONCLUSION: Posterior cruciate ligament-retaining total knee arthroplasty yielded satisfactory clinical and radiographic results in patients with rheumatoid arthritis at intermediate-term follow-up (mean, 10.5 years). Therefore, we believe that it remains an excellent treatment option for these patients.

Adult↗

Prophylaxis against fat and bone-marrow embolism during total hip arthroplasty reduces the incidence of postoperative deep-vein thrombosis: a controlled, randomized clinical trial.

BACKGROUND: Clinical and experimental studies have suggested that the maximum risk of thrombogenesis occurs during, rather than after, total hip arthroplasty. With use of conventional cementing techniques, insertion of a femoral component results in marrow embolization of tissue thromboplastin into the veins of the proximal part of the femur, leading to activation of the clotting cascade and thrombogenesis. We hypothesized that an operative technique designed for the prevention of fat and bone-marrow embolism can also reduce the incidence of postoperative deep-vein thrombosis and pulmonary embolism. METHODS: A total of 130 consecutive patients with osteoarthritis who were to have a primary total hip arthroplasty were randomly assigned to one of two groups. One group consisted of sixty-five patients (sixty-five hips) who had the femoral component inserted with our standard cementing technique without use of a bone vacuum, and the other group included sixty-five patients (sixty-five hips) who had the femoral component cemented with use of a bone-vacuum technique. In the hips managed with the bone vacuum, suction (-800 mbar) was applied to a drainage cannula placed along the linea aspera of the femur in order to prevent an increase in intramedullary pressure during the insertion of the stem. We measured the incidence of intraoperative fat and bone-marrow embolism with use of echocardiography and a transesophageal probe and the incidence of deep-vein thrombosis with use of serial duplex ultrasonography on the day before the operation and on postoperative days 4, 14, and 45. All patients were managed with prolonged pharmacological prophylaxis (low-molecular-weight heparin) against deep-vein thrombosis. RESULTS: The control group had significantly more severe and prolonged echocardiographic embolic events than did the group managed with the bone-vacuum technique (p < 0.05). A cascade of fine echogenic particles or embolic masses with a diameter of < or =5 mm was observed during the insertion of the stem in fifty-nine hips (91%) in which our standard cementing technique was used and in ten hips (15%) in which the bone-vacuum cementing technique was used. Deep-vein thrombosis was detected on postoperative day 4 in twelve patients (18%) in the control group and in two patients (3%) in the group managed with the bone-vacuum technique; the difference was significant (p < 0.05). CONCLUSIONS: Intraoperative prophylaxis against fat and bone-marrow embolism during total hip arthroplasty with cement can reduce the incidence of postoperative deep-vein thrombosis. We now use the bone-vacuum technique routinely in all total hip arthroplasties performed with cement.

Arthroplasty, Replacement, Hip↗

Impact of cost reduction programs on short-term patient outcome and hospital cost of total knee arthroplasty.

BACKGROUND: During the 1990s, cost reduction programs were developed to decrease the hospital cost of total knee arthroplasty. The purpose of this study was to evaluate the impact of hospital cost reduction programs for total knee arthroplasty on patient outcome at our hospital. METHODS: We evaluated 159 patients who had undergone unilateral primary total knee arthroplasty for the treatment of osteoarthritis at the Lahey Clinic. The results of fifty-six knee replacements performed in 1992 without a clinical pathway or a knee-implant standardization program (the control group) were compared with the results of 103 knee replacements performed in 1995 with a clinical pathway and a knee-implant standardization program (the study group). Before the operation, the two patient populations were similar in terms of age, pain score on a visual analog scale, and clinical knee scores; the groups were also similar with regard to the surgical approach and the time in the operating room. The minimum duration of follow-up was eight years for the control group and five years for the study group. RESULTS: All patients in both groups had excellent relief of pain and improvement in function. There were no differences in clinical outcome between the patient groups. The rate of patient satisfaction was 98% in the control group and 99% in the study group. Implementation of the clinical pathway was associated with a reduction in the average length of the stay in the hospital from 6.79 days in 1992 to 4.16 days in 1995. Implementation of the knee-implant standardization program was associated with increased use of all-polyethylene tibial components in 1995. Hospital cost adjusted for medical inflation was reduced 19% with the implementation of the clinical pathway and the knee-implant standardization program. CONCLUSIONS: The clinical pathway and the knee-implant standardization program reduced resource utilization and hospital cost for total knee arthroplasty without affecting short-term patient outcome in our hospital. Orthopaedic surgeons should carefully evaluate cost reduction programs, which may affect their patients, in order to maintain high-quality orthopaedic care and consistently successful patient outcomes.

Aged↗

Total knee arthroplasty in limbs affected by poliomyelitis.

BACKGROUND: Little information is available regarding the results and complications of total knee arthroplasty in limbs affected by poliomyelitis with severe knee degeneration. METHODS: We performed a retrospective chart and radiograph review of patients with a history of poliomyelitis involving a limb that subsequently underwent primary total knee arthroplasty between 1970 and 2000. Sixteen total knee arthroplasties were performed in limbs affected by poliomyelitis in fifteen patients. Eleven patients were followed for a minimum of two years, one (two knees) died before the minimum two-year follow-up could be completed, and three were followed for less than two years. No patient was lost to follow-up. RESULTS: There were two periprosthetic fractures, one peroneal nerve palsy, one avulsion of the patellar tendon, and four cases of recurrent instability. These complications were related to the poor bone quality, valgus deformity, patella baja, poor musculature, and attenuated soft tissues commonly found in knees affected by poliomyelitis. Knee Society pain and knee scores were improved postoperatively for all nine knees with a two-year follow-up that had had at least antigravity quadriceps strength prior to surgery. However, Knee Society function scores remained at 0 or worsened for six of the eleven knees followed for at least two years, including those with less than antigravity strength, and four of the nine knees with at least antigravity strength. None of the prostheses loosened. CONCLUSIONS: Pain and knee scores improved following total knee arthroplasty in patients with a history of poliomyelitis and antigravity quadriceps strength, but there was less pain relief in patients with less than antigravity quadriceps strength. Recurrence of instability and progressive functional deterioration is possible in all knees affected by poliomyelitis that have undergone total knee replacement, but they appear to occur more commonly in more severely affected knees.

Aged↗

Reconstruction of a ruptured patellar tendon with achilles tendon allograft following total knee arthroplasty.

BACKGROUND: Rupture of the patellar tendon after total knee arthroplasty is a rare and debilitating complication. Proper surgical management of this condition remains controversial. The purpose of this study was to review the results of reconstruction of a ruptured patellar tendon with an Achilles tendon allograft following total knee arthroplasty. METHODS: We reviewed our experience with the use of a fresh-frozen Achilles tendon allograft with an attached calcaneal bone graft to restore extensor function in nine patients with patellar tendon rupture following total knee arthroplasty (five primary and four revision). All patients were examined clinically and radiographically at an average of twenty-eight months. RESULTS: The average knee and functional scores improved from 26 and 14 points, respectively, before the surgery to 81 and 53 points after the surgery. The average extensor lag decreased from 44 degrees preoperatively to 3 degrees postoperatively, and the average range of motion of the knee increased from 88 degrees to 107 degrees. Two grafts failed in the early postoperative period. Both were repaired successfully. Radiographs showed an average proximal patellar migration of 17.8 mm, which did not appear to affect extensor function. CONCLUSIONS: This short-term follow-up study showed that once an Achilles allograft has healed, it can serve as a reliable reconstruction of a ruptured patellar tendon following total knee arthroplasty. This technique may be particularly suited for patients in whom the extensor mechanism was compromised by multiple prior operations. Continued follow-up is necessary to determine the long-term durability of these results.

Achilles Tendon↗

Effect of baseline functional status and pain on outcomes of total hip arthroplasty.

BACKGROUND: It is unknown whether there is an optimal time for surgery-that is, whether waiting until a patient has greater disability results in a worse outcome. We examined the effect of baseline status on the outcome of total hip arthroplasty to determine if such a relationship existed. METHODS: All Medicare patients undergoing total hip arthroplasty for osteoarthritis in twelve states were identified by the fiscal intermediary beginning in October 1994 and continuing for approximately eight months; 1640 eligible patients were identified. Consenting patients were surveyed within two months after the procedure and again at twelve months after the procedure, and their medical records were reviewed. The baseline survey, completed by 1120 patients, included items regarding the level of activity, the presence and severity of pain with walking, the need for assistance for walking, the distance that the patient could walk, and whether the patient could perform Instrumental Activities of Daily Living (IADLs). Data on comorbid diagnoses were collected from the medical records. RESULTS: Patients with pain during walking at baseline were more likely to have pain at one year than those without pain at baseline (21% compared with 9%; p < 0.05). Patients who needed assistance with walking at baseline were more likely to need assistance at one year than those who did not need assistance at baseline (38% compared with 15%; p < 0.01). Similar results were seen with regard to the need for assistance with housework (39% compared with 18%; p < 0.01) and grocery shopping (37% compared with 14%; p < 0.01) and, to a lesser extent, for overall participation in moderate activity (17% compared with 10%; p < 0.01). These results persisted after controlling for comorbidities in a multiple regression equation. However, the worse a patient's preoperative status, the more he or she gained in all four measures (p < 0.01). CONCLUSIONS: The findings of the present study suggest that the worse a patient's preoperative status, the more he or she may benefit from total hip arthroplasty. However, our findings also suggest that patients who have a worse preoperative status may not have as good an outcome as those who have a better preoperative status. Patients and physicians should consider these findings when discussing the timing of total hip arthroplasty.

Aged↗

Total hip arthroplasty in diastrophic dysplasia.

BACKGROUND: Diastrophic dysplasia results in severe disproportionate growth failure, multiple joint deformities, and early osteoarthritis of the hips. Mortality is increased in early childhood, but thereafter life expectancy is normal. Because of severe flexion deformities, resting pain, and diminished movements of the hip joints, total hip arthroplasty is indicated at an early age. The purpose of our study was to evaluate prospectively the midterm results of total hip arthroplasty in a consecutive series of patients with diastrophic dysplasia. METHODS: Between 1982 and 1996, forty-one total hip replacements were performed in twenty-four consecutive patients with diastrophic dysplasia (mean age, forty-one years) at our hospital. The patients were followed prospectively for a minimum of five years with clinical examination, determination of Harris hip scores, and radiographs. Twenty-two patients (thirty-eight hips) were examined clinically and radiographically at the time of follow-up, and the remaining two patients (three hips) were contacted only by telephone. The mean duration of follow-up was 7.8 years. RESULTS: The mean Harris hip score increased from 44 points (range, 25 to 66 points) before the operation to 70 points (range, 37 to 89 points) at the final follow-up examination (p < 0.001). Ten complications (24%) were recorded. Five (12%) of the forty-one hips required revision because of aseptic loosening of the acetabular component at a mean of 9.4 years after the primary operation. No revisions were due to aseptic failure of the femoral component. CONCLUSIONS: Implant survival was good and the Harris hip scores increased significantly after total hip arthroplasty in patients with diastrophic dysplasia. However, shortening femoral osteotomy and transposition of the greater trochanter, adductor and flexor tenotomies, and modification of the femoral stem were frequently needed. Total hip arthroplasty is recommended for patients with diastrophic dysplasia and severe degeneration of the hip joints, even for those who are relatively young. LEVEL OF EVIDENCE: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

Adult↗

Shoulder arthroplasty for the treatment of postinfectious glenohumeral arthritis.

BACKGROUND: Currently, no studies on shoulder arthroplasty after a previous infection of the shoulder have been published, as far as we know. The purpose of this study was to evaluate the rates of reinfection and the clinical results after shoulder arthroplasty for the treatment of postinfectious glenohumeral arthritis. METHODS: Between 1975 and 2000, thirteen patients with a history of infection of the shoulder that resulted in severe glenohumeral arthritis underwent shoulder arthroplasty. One patient who had been followed for less than two years was excluded. Therefore, twelve shoulders that had been followed for a minimum of two years (mean, 9.7 years) or until the time of revision surgery were included in the study. Complications, clinical results (pain, satisfaction, and range of motion), and radiographic results were documented at the time of the latest follow-up. RESULTS: No patient in this study had had a known reinfection at the time of the latest follow-up. Overall pain scores improved from 4.8 to 2.5 points after implantation of a prosthesis. Eight of the twelve patients had no pain or mild or moderate pain only after vigorous activity. The mean shoulder abduction improved from 75 degrees to 117 degrees, and the mean external rotation improved from 13 degrees to 36 degrees. Subjectively, only six of the twelve patients rated the result as much better or better. The results in the eight patients who underwent a full rehabilitation program were better than those in the four patients who underwent a limited-goals rehabilitation program. CONCLUSION: Shoulder arthroplasty for the treatment of the sequelae of an infected shoulder can be performed with a low risk of reinfection. While overall pain and motion can be expected to improve, unsatisfactory clinical results that are related to the destructive effects of the initial infection are not uncommon.