Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AIR CONDITIONING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Relation of respiratory water loss to coughing after exercise.

Exercise has been shown to result in bronchoconstriction, the extent of which is related to respiratory heat loss. Some normal subjects report coughing after exercise, and to determine whether this might also be related to respiratory heat loss, we monitored cough frequency after hyperpnea with air of varying temperature and water content in seven such subjects. Hyperpnea with fully saturated air at 37 degrees failed to provoke coughing and was not associated with heat loss or water loss. Hyperpnea with dry air at 37 degrees C resulted in more water loss (P less than 0.0005), less heat loss (P less than 0.01), and more coughing (P less than 0.001) than hyperpnea with subfreezing air. Hyperpnea with ambient air was associated with a similar cough frequency and water loss but with less heat loss (P less than 0.001) than hyperpnea with subfreezing air. There was a direct relation between cough frequency and respiratory water loss but no consistent relation between cough frequency and respiratory heat loss. This study indicates that coughing after hyperpnea with poorly conditioned air is related to the overall rate of respiratory water loss. Since strenuous exercise is associated with marked hyperpnea, coughing after exercise may also result from respiratory water loss.

Adult↗

International standards for the indoor environment.

UNLABELLED: On the international level, International Organization for Standardization (ISO), European Committee for Standardization (CEN) and American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) are writing and reviewing standards relating to the indoor environment on a regular basis. This presentation will focus on the development of standards for the indoor thermal environment and indoor air quality (ventilation). In the future, recommendations for acceptable indoor environments will be specified as classes. This allows for national differences in the requirements as well as for designing buildings for different quality levels. Several of these standards have been developed mainly by experts from Europe, North America and Japan. Are there, however, special considerations relating to South-East Asia (lifestyle, outdoor climate, economy) that are not dealt with in these standards and that will require the revision of existing standards? Critical issues are: adaptation, the effect of increased air velocity, humidity, type of indoor pollutant sources, etc. This paper will present an overview of existing methods, and discuss areas where revision of present standards or the development of new standards, are needed. PRACTICAL IMPLICATIONS: The international standards for the indoor environment provide the designer with criteria, which are internationally recognized, for the design of buildings and systems.

Air Pollution, Indoor↗

Validation of an environmental exposure unit for controlled human inhalation studies with grass pollen in patients with seasonal allergic rhinitis.

BACKGROUND: There is an increasing need for allergen inhalation systems to perform basic clinical research and test anti-allergic drugs under well-controlled conditions. This requires stability of environmental conditions like temperature and humidity, as well as allergen concentration and reproducible induction of allergic symptoms. OBJECTIVE: The aim of this study was to validate an environmental exposure unit for controlled human pollen inhalation studies in participants with seasonal allergic rhinitis. METHODS: Temperature, relative humidity, and air flow rate were kept constant with an air conditioning system. Pollen atmosphere was generated using a specially designed feeding system and monitored online by laser counter and offline using rotating rod samplers. Efficacy (total nasal symptom score, nasal air flow rate, nasal secretion) and safety (lung function) parameters were evaluated at different pollen concentrations and repeated allergen challenges. RESULTS: Temperature, humidity, and air flow rate in the environmental exposure unit remained constant within a range of <2%. The spatial distribution and the temporal stability of the pollen concentration varied only slightly over 4 h (+/-10% and <4%, respectively). Dose-dependent induction of allergic rhinitis symptoms, reduction in nasal air flow rate, and increase in nasal secretion were observed over time. These effects were reproducible from day to day. Lung function remained clinically normal at all concentrations and from day to day. CONCLUSIONS: Thus, pollen exposure in the environmental exposure unit is an effective, reproducible, safe, and suitable method for single-centre clinical studies on the efficacy of anti-allergic treatment or basic clinical research.

Adult↗

Treatment of MTBE by air stripping, carbon adsorption, and advanced oxidation: technical and economic comparison for five groundwaters.

An investigation was made of the treatability of methyl tert-butyl ether (MTBE) in five groundwaters with highly varied water quality characteristics. Air stripping, granular activated carbon (GAC) adsorption, and the O(3)/H(2)O(2) and UV/H(2)O(2) advanced oxidation processes were compared in a mobile water treatment pilot plant under a variety of process conditions. Air stripping was shown to have the lower unit treatment costs for higher flowrates (i.e., 3800L/min), although relatively tall towers were required for greater treatment requirements. At low flowrates (i.e., 38L/min), advanced oxidation provided the lowest treatment costs for four of five waters (but was ineffective for a high chemical oxygen demand water). Both the O(3)/H(2)O(2) and UV/H(2)O(2) processes were more efficient at pH 7 versus 9 due in part to increased scavenging at higher pH. GAC was examined using rapid small-scale column tests (RSSCT). GAC was effective at most conditions, although it was also the most costly alternative for most waters. The results of this study can help to provide specific guidance into process selection for treating MTBE in contaminated groundwaters.

Adsorption↗

Increased platelet and red cell counts, blood viscosity, and plasma cholesterol levels during heat stress, and mortality from coronary and cerebral thrombosis.

Recorded deaths from coronary and cerebral thrombosis rise markedly in heat waves. In a British heat wave with little or no distortion due to air-conditioning, outside temperatures of 34.6 degrees C (maximum) and 20.8 degrees C (minimum) were followed by peak mortalities from coronary and cerebral thrombosis one to two days later. Experimental exposure of volunteers to moving air at 41 degrees C for six hours caused core temperature to rise 0.84 degree C, weight to fall 1.83 kg with sweating despite access to water, heart rate to increase 32 beats per minute, and arterial pressure to fall, particularly on standing. The red blood cell count increased 9 percent, and blood viscosity increased 24 percent, mostly after the first hour. The platelet count rose 18 percent, and the platelet volume fell, mostly in the first hour. The plasma cholesterol level increased 14 percent without a change in distribution among lipoprotein fractions. The changes seem able to explain the increased mortality from arterial thrombosis in hot weather.

Adult↗

A chamberless field exposure system for ozone enrichment of short vegetation.

Only few studies have been conducted as yet which focus on the effects of rising tropospheric ozone levels on semi-natural vegetation under free-air conditions. A new technical approach was used to examine the response of calcareous grassland to ozone employing a chamberless fumigation system. Four different ozone regimes were applied (1-, 1.33-, 1.66- and 2-fold ambient air levels) with five replicates each. Ozone enrichment was carried out on circular plots of 2 m in diameter by a computer controlled exposure system. Transparent windscreens encircling each plot accelerated the mixing of ambient air and ozone released. Thus, the use of blowers could be avoided. The exposure system presented here is regarded as an appropriate technique for free-air trace gas enrichment on short vegetation avoiding microclimatic alterations known to affect plant growth and pollutant uptake. Furthermore, the chosen technical set-up was rather cost-effective. Hence, it enabled the establishment of a larger number of replications providing the basis for results of higher statistical power.

Air Pollutants↗

Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.

Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.

Aerosols↗

Influence of ventilation strategies on indoor radon concentrations based on a semiempirical model for Florida-style houses.

Measurements in a full-scale experimental facility are used to benchmark a semiempirical model for predicting indoor radon concentrations for Florida-style houses built using slab-on-grade construction. The model is developed to provide time-averaged indoor radon concentrations from quantitative relationships between the time-dependent radon entry and elimination mechanisms that have been demonstrated to be important for this style of residential construction. The model successfully predicts indoor radon concentrations in the research structure for several pressure and ventilation conditions. Parametric studies using the model illustrate how different ventilation strategies affect indoor radon concentrations. It is demonstrated that increasing house ventilation rates by increasing the effective leakage area of the house shell does not reduce indoor radon concentrations as effectively as increasing house ventilation rates by controlled duct ventilation associated with the heating, ventilating, and air conditioning system. The latter strategy provides the potential to minimize indoor radon concentrations while providing positive control over the quality of infiltration air.

Air Pollution, Indoor↗

Cold air inhalation does not affect the severity of EIB after exercise or eucapnic voluntary hyperventilation.

INTRODUCTION: Exercise-induced bronchoconstriction (EIB) is thought to result from osmotic and thermal events of air conditioning during exercise at high ventilation rates. The purpose of this study was to evaluate lung function after exercise and eucapnic voluntary hyperventilation (EVH) while breathing both room-temperature and cold-temperature dry bottled air. METHODS: Twenty-two subjects were identified as EIB probable by a fall of >or=7% in forced expiratory volume in the first second of exhalation (FEV1) using a 6-min room-temperature EVH challenge (RTEVH; 22.0 degrees C). Subjects then randomly performed three 6-min challenges: cold-temperature EVH (CTEVH; -1 degrees C), room-temperature exercise (RTEX; 22.0 degrees C), and cold-temperature exercise (CTEX; -1 degrees C), with a period of at least 48 h observed between challenges. Spirometry was performed at baseline and at 5, 10, 15, and 20 min postchallenge. RESULTS: Reasonable agreement was found between challenge modes and room-temperature and cold-temperature challenges. Postchallenge percent falls in FEV1 were -15.21, -13.80, -13.12, and -10.69 for RTEVH, CTEVH, RTEX, and CTEX, respectively. RTEVH resulted in a significantly greater percent fall in FEV1 than CTEX (P=0.048); no other differences in FEV1 were observed. CONCLUSION: Similar postchallenge percent falls in FEV1 for room- and cold-temperature EVH and exercise suggest that dryness is essential to test conditions, as cold temperature did not have an additive effect to the EIB response.

Adult↗

Aircraft measurements of nitrogen and phosphorus in and around the Lake Tahoe Basin: implications for possible sources of atmospheric pollutants to Lake Tahoe.

Atmospheric deposition of nitrogen (N) and phosphorus (P) into Lake Tahoe appears to have been a major factor responsible for the shifting of the lake's nutrient response from N-limited to P-limited. To characterize atmospheric N and P in and around the Lake Tahoe Basin during summer, samples were collected using an instrumented aircraft flown over three locations: the Sierra Nevada foothills east of Sacramento ("low-Sierra"), further east and higher in the Sierra ("mid-Sierra"), and in the Tahoe Basin. Measurements were also made within the smoke plume downwind of an intense forest fire just outside the Tahoe Basin. Samples were collected using a denuder-filter pack sampling system (DFP) and analyzed for gaseous and water-soluble particle components including HNO3/ NO3-, NH3 /NH4+, organic N (ON), total N, SRP (soluble reactive phosphate) and total P. The average total gaseous and particulate N concentrations (+/- 1sigma) measured over the low- and mid-Sierra were 660 (+/- 270) and 630 (+/- 350) nmol N/m3-air, respectively. Total airborne N concentrations in the Tahoe samples were one-half to one-fifth of these values. The forest fire plume had the highest concentration of atmospheric N (860 nmol N/m3-air) and a greater contribution of organic N (ON) to the total N compared to nonsmoky conditions. Airborne P was rarely observed over the low- and mid-Sierra but was present at low concentrations over Lake Tahoe, with average +/- 1sigma) concentrations of 2.3 +/- 2.9 and 2.8 +/- 0.8 nmol P/m3-air under typical clear air and slightly smoky air conditions, respectively. Phosphorus in the forestfire plume was present at concentrations approximately 10 times greater than over the Tahoe Basin. P in these samples included both fine and coarse particulate phosphate as well as unidentified, possibly organic, gaseous P species. Overall, our results suggest that out-of-basin emissions could be significant sources of nitrogen to Lake Tahoe during the summer and that forest fires could be important sources of both N and P.

Air Movements↗

Growth hormone response to exercise in asthmatic and normal children.

Maximal growth hormone (GH) increments following exercise were compared in asthmatic (n = 14) and normal (n = 8) children. Exercise, which consisted of 6 min ergometer cycling while breathing cold dry (CD) air, induced asthma in all asthmatic patients but not in normal subjects. Baseline plasma GH levels were similar in both groups. Following exercise, however, asthmatic patients had significantly higher mean GH increments than normal subjects (14.8 vs 4.9 ng/ml, P less than 0.025). To evaluate the possible role of bronchoconstriction in the GH response all subjects exercised again, this time while breathing warm humid (WH) air. Despite the absence of exercise-induced asthma (EIA) while breathing WH air, asthmatic patients still had significantly higher mean GH increments than normal subjects (9.2 vs 2.3 ng/ml, P less than 0.05). We conclude that some asthmatic children show excessive GH secretion after exercise regardless of inspired air conditions or the development of EIA.

Adolescent↗

Neurology of allergic inflammation and rhinitis.

Afferent nerves, derived from the trigeminal ganglion, and postganglionic autonomic nerves, derived from sympathetic and parasympathetic ganglia expressing many different neurotransmitters, innervate the nose. Reflexes that serve to optimize the air-conditioning function of the nose by altering sinus blood flow, or serve to protect the nasal mucosal surface by mucus secretion, vasodilatation, and sneezing, can be initiated by a variety of stimuli, including allergen, cold air, and chemical irritation. Activation of nasal afferent nerves can also have profound effects on respiration, heart rate, blood pressure, and airway caliber (the diving response). Dysregulation of the nerves in the nose plays an integral role in the pathogenesis of allergic rhinitis. Axon reflexes can precipitate inflammatory responses in the nose, resulting in plasma extravasation and inflammatory cell recruitment, while allergic inflammation can produce neuronal hyper-responsiveness. Targeting the neuronal dysregulation in the nose may be beneficial in treating upper airway disease.

Animals↗

A new method for the rapid determination of volatile organic compound breakthrough times for a sorbent at concentrations relevant to indoor air quality.

The use of sorbents has been proposed to remove volatile organic compounds (VOCs) present in ambient air at concentrations in the parts-per-billion (ppb) range, which is typical of indoor air quality applications. Sorbent materials, such as granular activated carbon and molecular sieves, are used to remove VOCs from gas streams in industrial applications, where VOC concentrations are typically in the parts-per-million range. A method for evaluating the VOC removal performance of sorbent materials using toluene concentrations in the ppb range is described. Breakthrough times for toluene at concentrations from 2 to 7500 ppb are presented for a hydrophobic molecular sieve at 25%) relative humidity. By increasing the ratio of challenge gas flow rate to the mass of the sorbent bed and decreasing both the mass of sorbent in the bed and the sorbent particle size, this method reduces the required experimental times by a factor of up to several hundred compared with the proposed American Society of Heating, Refrigerating, and Air-Conditioning Engineers method, ASHRAE 145P, making sorbent performance evaluation for ppb-range VOC removal more convenient. The method can be applied to screen sorbent materials for application in the removal of VOCs from indoor air.

Adsorption↗

Development of push-pull ventilation.

Push-pull ventilation (air is blown across a contaminant generation area toward an exhaust hood) can have distinct advantages over exhaust ventilation alone. It can control contaminant emission into the workplace better than exhaust only, and much less conditioned air must be exhausted so there are energy savings. This paper presents suggested push and pull flow rates for open surface tank operations such as plating. About 98% of the contaminant generated can be captured by a push-pull system using the proper flow rates.

Ethanol↗

Biodecontamination of animal rooms and heat-sensitive equipment with vaporized hydrogen peroxide.

Common methods used to decontaminate and disinfect laboratory animal areas are difficult to standardize, labor-intensive, and potentially hazardous for staff members and the environment. As an alternative to traditional methods, we tested fumigation with vaporized hydrogen peroxide by using the VHP 1000 Biodecontamination System. The design of our air-conditioning system allowed the connection of the generator to any animal room by using the ventilation piping, thus forming a closed circuit. A 3-h cycle consisting of dehumidification, conditioning, sterilization, and aeration was developed and shown to be effective. The biodecontamination process was monitored during five independent trials using chemical and biological (Bacillus stearothermophilus spores) indicators. Contact plates for testing surfaces and room air for environmental bacteria, yeasts, and fungi consistently showed fewer than 10 colony-forming units per 100 cm2 or per 1 liter air. In addition, this method proved successful with heat-sensitive equipment like the blower units of individually ventilated caging systems. Overall, the system was easy to use and very effective in biodecontaminating animal rooms and equipment in a reproducible manner. There were no signs of corrosion or functional damage after more than 10 fumigation cycles. Work load and potential health risk for staff members and the environment was negligible.

Animals↗

[Standardised environmental conditions for neurocognitive laboratories].

INTRODUCTION AND AIMS: The exploration of neurocognition in neurology departments has gone a long way from the traditional psychometric tests to the present day use of high technology methods in cognitive neurophysiology, as is the case of event related potentials. Given the increased sensitivity of these procedures, it has become absolutely essential to control the influence of environmental variables that may exert non controlled effects on the patient s response. Many neurocognitive laboratories have been set up in premises in which the spatial layout and the environmental characteristics have been determined beforehand and consequently technical staff has had to prepare these rooms in an empirical way. This gives rise to two types of drawbacks: interferences in the patient s concentration and low reproducibility of the results in other laboratories. METHOD: In this paper we present a proposed set of standardised conditions for a neurocognitive laboratory from an architectural perspective, and more specifically with regard to interior design. We outline the functional design of the premises, the conditions for workplaces where VDU computers (Video Display Units) are used and where psychometric evaluation is carried out. We also discuss the criteria to be followed when placing the laboratory within a hospital, lighting parameters, air conditioning and suggestions about psychological input. CONCLUSIONS: Although we do not seek to establish a rigid set of norms, these conditions will raise the quality of evaluations and facilitate the comparison of results because of the reduced variability from the environment.

Architecture↗

Hypoxic pulmonary vasoconstriction disappears in a rabbit model of cavopulmonary shunt.

BACKGROUND: Cavopulmonary shunt is widely known as an interim staging procedure in patients with single-ventricle physiology. However, the physiologic characteristics of the pulmonary arterial system after cavopulmonary shunt are not clearly understood. In this article, we developed a rabbit cavopulmonary shunt model and studied the morphologic changes and physiologic characteristics (namely, hypoxic pulmonary vasoconstriction) of pulmonary arteries after cavopulmonary shunt. METHODS: Male Japanese white rabbits aged 12 to 16 weeks were used for the study. In 5 rabbits, the superior vena cava was anastomosed to the right pulmonary artery in an end-to-side fashion, followed by a proximal side ligation of the right pulmonary artery (cavopulmonary shunt group). In 4 rabbits, the superior vena cava and the right pulmonary artery were dissected and clamped for 10 minutes without making a cavopulmonary shunt (sham group). Two weeks after the operation, we then measured the internal diameter of the acinar (internal diameter, 164 +/- 7 microm), the lobular (305 +/- 13 microm), and the segmental (669 +/- 16 microm) pulmonary arteries in both controlled and hypoxic conditions by using a specially designed x-ray television system. Also, morphometric measurements were made in the pulmonary arteries around the terminal bronchioles. RESULTS: Two weeks after the operation, the arterial oxygen tension under room air conditions was significantly lower in the cavopulmonary shunt group than in the sham group (68.2 +/- 2.2 mm Hg vs 91.1 +/- 1.9 mm Hg; P =.01). The baseline internal diameters in the acinar and the lobular (resistance), but not the segmental (conduit), pulmonary arteries on the anastomosed side of the cavopulmonary shunt group were significantly larger than those of pulmonary arteries on the nonanastomosed side of the cavopulmonary shunt group and the sham group. Moreover, the pulmonary arteries on the anastomosed side of the cavopulmonary shunt group did not respond to hypoxia, whereas those on the nonanastomosed side of the cavopulmonary shunt and sham groups did have local internal diameter reductions in the acinar and lobular arteries (-1.1% +/- 1.0% in the anastomosed side vs -17.7% +/- 3.5% in the nonanastomosed side vs -20.9% +/- 6.1% in the sham group; P =.03). In the morphometric studies, the internal diameter of the pulmonary artery accompanying the terminal bronchiole in the anastomosed side of the cavopulmonary shunt group was significantly larger, and the ratio of medial thickness relative to the outer diameter was smaller compared with ratios in the nonanastomosed side of the cavopulmonary shunt group and the sham group. CONCLUSIONS: We developed a rabbit cavopulmonary shunt model. In the anastomosed side of the cavopulmonary shunt group, the peripheral pulmonary arteries, which contributed greatly in regulating the pulmonary vascular resistance, had a local reduction in the basal vascular tone and no hypoxic vasoconstriction 2 weeks after the operation.

Animals↗

Waste gas exposure to sevoflurane and nitrous oxide during anaesthesia using the oesophageal-tracheal Combitube small adult.

Exposure to sevoflurane (SEV) and nitrous oxide during ventilation using a Combitube (37Fr) small adult (SA) was compared with waste gas exposure using conventional endotracheal tubes. Trace concentrations of SEV and nitrous oxide were assessed using a direct reading spectrometer during 40 gynaecological laparoscopic procedures under general anaesthesia. Measurements were made at the patients' mouth and in the anaesthetists' breathing zone. Mean (SD) concentrations of SEV and nitrous oxide measured at the patients' mouth were comparable in the Combitube SA (SEV 0.6 (0.2) p.p.m.; nitrous oxide 9.7 (8.5) p.p.m.) and endotracheal tube group (SEV 1.2 (0.8) p.p.m.; nitrous oxide 17.2 (10.6) p.p.m.). These values caused comparable contamination of the anaesthetists' breathing zone (SEV 0.6 (0.2) p.p.m. and nitrous oxide 4.3 (3.7) p.p.m. for the Combitube SA group, compared with SEV 0.5 (0.2) p.p.m. and nitrous oxide 4.1 (1.8) p.p.m. for the endotracheal tube group). We conclude that the use of the Combitube SA during positive pressure ventilation is not necessarily associated with increased waste gas exposure, especially when air conditioning and scavenging devices are available.

Adult↗