Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “intercept”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Ethanol effects on delayed spatial matching as modeled by a negative exponential forgetting function.

Performance on delayed matching-to-position as a function of ethanol was investigated in rats and dose effects assessed by fitting an exponential decay model of forgetting to signal detection sensitivity scores. Three ethanol doses (0.25, 0.50, and 0.75 g/kg) and one isovolume saline control were examined. For further comparison, one dose of chlordiazepoxide (CDP; 5 mg/kg) and its saline control were also given. Forgetting functions were reasonably well described by the decay model under all treatment conditions. In addition, the functions's decay constant (-b) proved to be differentially sensitive to both drug and dose effects. Reduced decay estimates were obtained following the two lowest ethanol doses, the reduction being statistically significant for the 0.25 g/kg dose. In contrast, the function estimate of initial sensitivity, the intercept parameter (SI0), was not significantly affected by ethanol. Consistent with the low-dose ethanol effects, CDP significantly decreased the value of the decay parameter while leaving the intercept parameter unaffected. But unlike ethanol, the variance accounted for by the model for the individual data was less following CDP administration. Drug effects were interpreted using the exponential decay model of forgetting, and the results suggest independent discriminative control over SI0 and b. The significant effect of the low-dose sedative-hypnotics upon b, with no attendant effects upon SI0, is suggested to result from enhanced, spontaneous, delay interval mediation.

Animals↗

All out anaerobic capacity tests on cycle ergometers. A comparative study on men and women.

We have studied the effects of the braking force on the results of an anaerobic capacity test derived from the Wingate test (an all out 45 s exercise on a Monark 864 cycle ergometer against a given force at the fastest velocity from the beginning to the end of the test). Seven men and seven women participated in the study and performed a total of 63 all-out tests against different braking forces. The same subjects performed a force-velocity test on the same cycle ergometer. Since the relationship between force and velocity is approximately linear for peak velocities between 100 and 200 rev X min-1 (Pérès et al. 1981a, b; Nadeau et al. 1983; Vandewalle et al. 1983) we characterized each subject by three parameters: P0 (the intercept of the force-velocity regression line with the force axis), V0 (the intercept of the regression line with the velocity axis) and Wmax (maximal power). The relationship between force and mean power was parabolic for the all-out anaerobic capacity test. In the present study the optimal force (the force giving the maximal value of mean power during an all out test) was higher for the men (approximately 1 N X kg BW-1) than the force proposed by others (0.853 N X kg BW-1 for Dotan and Bar-Or 1983). However, because of the parabolic relationship between force and mean power, the mean power which corresponds to the optimal force was approximately the same in both studies.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Short-term regulation of arterial pressure and the calculation of open-loop gain in the intact anesthetized dog.

Open-loop gain of the short-term systemic pressure regulation was determined under closed-loop conditions in the closed chest anesthetized dog (n = 5). For this purpose, cardiac output and mean systemic pressure were varied by ventricular pacing after the production of complete heart block. From the pressure-flow data resistance gain (the ratio of peripheral resistance change to pressure change in the steady state) was obtained by means of a simple model. The value of this gain was automatically estimated by fitting the pressure-flow relation described by the model to the experimental data. The model allows the pressure-flow relation to be straight or curved with or without a zero-flow pressure intercept. The best fit was obtained when the pressure-flow curve was convex to the pressure axis and had no intercept. When the model was linearized about the control values of pressure and flow (operating point), open-loop gain could be calculated from resistance gain. Its averaged value in the control condition, 1.63 +/- 0.45, is in agreement with values found by other investigators in open-loop conditions. During vasoconstriction open-loop gain, at the (new) operating point, increased to 2.51 +/- 0.51; during vasodilation it decreased to 1.17 +/- 0.27. Open-loop gain about an operating point thus can be determined in the intact animal from measurements of mean pressure and mean flow in the steady state.

Animals↗

Influence of angular velocity and movement frequency on development of fatigue in repeated isokinetic knee extensions.

Six sedentary students, six orienteers, and six soccer players were each subjected to 15 tests, comprising 120 s of repeated, maximal isokinetic knee extensions. The tests differed with respect to movement velocity (30 degrees.s-1, 120 degrees.s-1, and 300 degrees.s-1), and movement frequency (5 at each velocity). At a certain velocity, a rectilinear relationship was found between muscular performance intensity (expressed either as average power output or as exercise time ratio) and development of fatigue (expressed either as an absolute or as a fractional decline in work output). Significant inter-velocity differences existed between the slopes of these lines at some combinations of performance and fatigue expressions. Only tendencies towards a difference in x-intercept values were found. This x-intercept value can be taken as a measure of the greatest attainable intensity level of performance without the development of fatigue. This suggestion is valuable both in basic physiological research, and as a possible criterion for optimization of muscular performance. At a given exercise time ratio, increasing movement velocity produced increasing fatigue. However, at a given muscular power output--above 15 W approximately--fatigue developed to a greater extent at the low velocity than at the two higher ones, which did not differ significantly. Substantial individual variation was seen in the positions of the low-, medium-, and high-velocity lines. These variations did not depend on the training background. This implies that the validity of using single-velocity, single-frequency tests in determining isokinetic endurance is doubtful.

Adult↗

Automated measurement of lipoprotein(a) by immunoturbidimetric analysis.

Immunoturbidimetric analysis of lipoprotein(a) in plasma or serum was developed for use on the Roche COBAS FARA II and COBAS MIRA clinical chemistry analyzers. The components of the assay are: (1) buffer consisting of 2.25% polyethylene glycol in phosphate-buffered saline, 0.2% gelatin, and a surfactant; (2) fractionated goat anti-human lipoprotein(a) IgG; (3) five standards with lipoprotein(a) concentrations ranging from 0.05 to 1.0 g/l; (4) two controls with concentrations of approximately 0.2 and 0.5 g/l. The analyzer delivers sample and buffer, incubates the reaction mixture at 37 degrees C for 5 min, delivers neat lipoprotein(a) antibody, and incubates for an additional 10 min. The lipoprotein(a) concentration of samples is calculated by the COBAS DENS (Data Evaluation for Non-linear Standard Curves) option by fitting the standard curve values to a four-parameter logit-log curve model. Total imprecision results (CV%) for the FARA II and MIRA were under 11% (NCCLS protocol EP5-T). The assay is linear beyond the highest calibrator to 2.6 g/l. No interference was observed for plasminogen up to 2.3 g/l, apolipoprotein B up to 4.36 g/l, hemoglobin up to 10 g/l, bilirubin up to 4.0 g/l, and triglycerides up to 4.36 g/l. Comparison with a double monoclonal ELISA used at the Northwest Lipid Research Laboratories yielded: R = 0.970, slope = 1.013, and y-intercept = 0.00009 (n = 37). Comparison with a commercially available ELISA kit for lipoprotein(a) yielded: r = 0.987, slope = 1.243, and y-intercept = 0.024 (n = 40). This assay provides rapid, accurate, and precise screening of lipoprotein(a) in serum or plasma.

Antibody Formation↗

Stereological estimates of nuclear volume in normal mucosa and carcinoma in situ of the human urinary bladder.

The nuclear volume of the epithelial cells in the human urinary bladder mucosa has been estimated using point sampled intercepts in vertical sections (local vertical windows). The study included 27 specimens: ten from normal bladder mucosa, five from inflamed mucosa, seven from mucosa with flat grade II lesions and five from mucosa with flat grade III lesions. After standard fixation, embedding, sectioning and haematoxylin-eosin staining an unbiased estimate of the mean volume of nuclei sampled with a chance proportion to the volume = vV = pi/3 x (l0)3 was calculated using a frame for orientating the linear test probe in vertical sections. Here l0 is the length of the intercept through a test point hitting a nucleus measured in a random direction through the test point. The weighted mean nuclear volume of bladder mucosa with grade II and grade III lesions (537 microns 3 and 494 microns 3 respectively) was significantly larger than the weighted mean nuclear volume of normal (133 microns 3) and inflamed bladder mucosa (182 microns 3). This simple and fast estimation of nuclear volume seems to provide objective data useful in discriminating between neoplastic and non-neoplastic lesions of the bladder mucosa.

Carcinoma in Situ↗

Comparisons of the time-activity curves of the cardiac blood pool and liver uptake by 99mTc-GSA dynamic SPECT and measured 99mTc-GSA blood concentrations.

OBJECTIVES: The aim of this study was to determine the time-activity curve in the cardiac and hepatic region by 99mTc-GSA dynamic SPECT which is clinically used in liver scintigraphy and evaluate the temporal changes in the consistency and errors at the absolute scale using the regression equation of changes in the blood concentration of 99mTc-GSA. METHODS: In 11 patients who underwent 99mTc-GSA dynamic SPECT over the 30 min period after IV injection, the percentages of activity in the collected blood and in the blood pool estimated by dynamic SPECT were determined as the plasma clearance by blood collection and as the blood clearance by cardiac pooling. Extrahepatic uptake, expressesd as 100--(% uptake in the liver by dynamic SPECT (%)) was calculated as the blood clearance by the liver. The regression equation (Y = Y0 + Ae(-alphat)) was determined from the changes in the counts, expressed as a percent. Percent errors and the differences in the Y-intercept (Y0), coefficient (A) and slope (alpha) on the regression curve were compared. RESULTS: Blood pool clearance gradually exceeded the measured plasma clearance. The clearance by the liver started from a very low initial value and gradually became equal to that of plasma clearance over the first 15 minutes and exceeded it over the second 15 minutes. The Y-intercept was significantly higher in the blood pool clearance than that in the measured plasma clearance (p < 0.001), and the coefficient was significantly lower in the former than the latter (p < 0.001). The coefficient and slope were significantly lower in the hepatic clearance than the plasma clearance (p < 0.001, p < 0.005). CONCLUSION: The time-activity curve of the blood pool showed a tendency towards overestimation in the second half of the examination, probably due to scatter effect from the liver. The time-activity curve of liver uptake showed a tendency towards overestimation in the first half of the examination, probably due to the high concentration in the hepatic blood pool, and underestimation in the second half.

Adult↗

Sandwich-type enzyme immunoassay for human chorionic gonadotropin.

We have developed a sandwich-type enzyme immunoassay for human chorionic gonadotropin (hCG), in which antibody Fab'-beta-D-galactosidase complex and an antibody-immobilized silicone rubber solid phase were used. Despite the fact this assay system crossreacted about 40% with human luteinizing hormone (LH) that contains an immunologically very similar subunit to that of hCG, it proved to be highly sensitive with hCG measurable at levels as low as 0.3 mIU per assay tube. Using 25 microliter of urine sample, hCG levels in serum (10-1000 mlU/ml) or in urine (3-300 mlU/ml) could be determine with the same degree of precision as in radioimmunoassay without sample interference with the assay. The coefficients of variation in within-run, and between-run were 9.2-13.3%, and 4.2-18.8%, respectively. Values obtained with enzyme immunoassay correlate well with those of radioimmunoassay (r = 0.961, slope = 1.129, y-intercept = 3.7 mlU/ml for 35 serum samples) and hemagglutination assay (r = 0.954, slope = 0.951, y-intercept = 1.8 mlU/ml for 88 urine samples).

Chorionic Gonadotropin↗

Aortic pressure-diameter relation in patients with non-insulin dependent diabetes mellitus: new insights.

AIMS/HYPOTHESIS: Type II (non-insulin-dependent) diabetes mellitus is associated with macrovascular disease. Therefore, we investigated the aortic elastic properties by a new method in patients with diabetes and control patients matched with them. METHODS: Patients with Type II diabetes (n = 20) and control patients without diabetes (n = 21) were enrolled in the study. All patients had coronary artery disease. Instantaneous aortic diameter was measured by an intravascular catheter developed in our institution. Instantaneous aortic pressure was measured simultaneously at the same aortic level with a catheter-tip micromanometer. Thus, aortic pressure-diameter loops were obtained and slope and intercept were calculated. Aortic distensibility, stiffness constant and energy loss were also calculated. RESULTS: The mean age and the heart rate were similar in the two groups. The pulsatile changes in aortic diameter were greater in the control group (0.94 +/- 0.4 vs 1.28 +/- 0.4 mm, p < 0.01). The stiffness of the aortic wall was greater in diabetic patients as indicated from the following variables: the distensibility was less in patients with diabetes (1.16 +/- 0.6 vs 1.95 +/- 0.9 cm2 x dyne(-1) x 10(-6), p <0.01); the slope was greater (113.4 +/- 120.1 vs 51.61 +/- 3.3 mmHg/mm, p < 0.01) and the intercept was less in diabetic patients (-2301.9 +/- 2692.9 vs -1114.45 +/- 295.6 mmHg, p < 0.01); the stiffness constant was greater in patients with diabetes (1.66 +/- 1.8 vs 0.77 +/- 0.8 mm(-1), p < 0.03). Aortic energy loss was, however, similar between the groups. CONCLUSION/INTERPRETATION: In patients with non-insulin dependent diabetes aortic elastic properties, evaluated by pressure-diameter relation, are impaired. This could play an important part in the development of vascular complications related to diabetes.

Aorta, Thoracic↗

Comparison of aqua regia and HNO3-H(2)O(2) procedures for extraction of Tl and some other elements from soils.

The relationship between aqua regia (ISO 11466) and HNO(3)-H(2)O(2) (ISO/CD 20279) extraction procedures for atomic emission spectrometric (ICP/OES and ICP/MS) determinations of Tl, P, Mn, Fe, Mg, Ca, Sr, Al, K, As, Bi, Zn, Pb, Co, Cd, Ni, V, Be, Cu and Cr was investigated. Soil samples (155) representing areas with different contents of the elements were selected for the comparison. Tl was the element of the highest interest and therefore the sampling sites were chosen to achieve as wide range of Tl contents as possible. Both extraction procedures are comparable in results (differences lower than 10% for the most of the elements) for all the tested elements. Statistically non-significant differences between the two extraction procedures were found for P, Zn, V and K (the slope was very close to 1 and the intercept included zero). Statistically significant values of intercepts were found for Fe, Al, Ca, Cd, Sr and Ni. Significantly higher results for aqua regia were found for Cu (12%), Pb (17%), Mn (11%) and lower results by aqua regia were found for Mg (4%), As (13%), Co (20%), Be (11%), Cr (4%) and Bi (6%). The results for Tl, the element of the highest interest, after HNO(3)-H(2)O(2) extraction procedure, were approximately 6% higher than the results after aqua regia extraction. Content of Tl in the soil samples was from 0.08 to 2.8 mg kg(-1). A highly significant linear relationship was found (R(2)=0.97).

Journal Article↗

Grip forces when passing an object to a partner.

The goal of the present study was to investigate how grip forces are applied when transferring stable control of an object from one person to another. We asked how grip forces would be modified by the passer to (1) control for inertial forces as the object was transported toward the receiver and (2) control for the impending perturbation when the receiver made contact with the object. Twelve volunteers worked in pairs during this experiment. One partner, playing the role of passer, transported an object with embedded load cells forward or held the object at an interception location. The second partner, playing the role of receiver, waited at an interception location or reached toward the passed object. Kinematic results indicated that while passers performed a stereotypical movement, receivers were sensitive to the motion of the object as they reached to make contact. Grip force results indicated that passers' grip forces and grip/load force ratios were variable on a trial-to-trial basis, suggesting that a refined internal model of the passing task was not achieved within the timeframe of the experiment. Furthermore, a decoupling of the temporal and magnitude characteristics of the grip and inertial forces was noted in conditions where passers transported the object toward the receiver. During object transfer, it was noted that passers used visual feedback-based anticipatory control to precisely time initial grip force release, while somatosensory control was used by both the passer and receiver to precisely coordinate transfer rate.

Adolescent↗

High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements.

A high-resolution magnetic resonance imaging (MRI) protocol, together with specialized image processing techniques, was applied to the quantitative measurement of age-related changes in calcaneal trabecular structure. The reproducibility of the technique was assessed and the annual rates of change for several trabecular structure parameters were measured. The MR-derived trabecular parameters were compared with calcaneal bone mineral density (BMD), measured by dual X-ray absorptiometry (DXA) in the same subjects. Sagittal MR images were acquired at 1.5 T in 23 healthy women (mean age: 49.3 +/- 16.6 [SD]), using a three-dimensional gradient echo sequence. Image analysis procedures included internal gray-scale calibration, bone and marrow segmentation, and run-length methods. Three trabecular structure parameters, apparent bone volume (ABV/TV), intercept thickness (I.Th), and intercept separation (I.Sp) were calculated from the MR images. The short- and long-term precision errors (mean %CV) of these measured parameters were in the ranges 1-2% and 3-6%, respectively. Linear regression of the trabecular structure parameters vs. age showed significant correlation: ABV/TV (r2 = 33.7%, P < 0.0037), I.Th (r2 = 26.6%, P < 0.0118), I.Sp (r2 = 28.9%, P < 0.0081). These trends with age were also expressed as annual rates of change: ABV/TV (-0.52%/year), I.Th (-0.33%/year), and I.Sp (0.59%/year). Linear regression analysis also showed significant correlation between the MR-derived trabecular structure parameters and calcaneal BMD values. Although a larger group of subjects is needed to better define the age-related changes in trabecular structure parameters and their relation to BMD, these preliminary results demonstrate that high-resolution MRI may potentially be useful for the quantitative assessment of trabecular structure.

Absorptiometry, Photon↗

The effect of trabecular structure on DXA-based predictions of bovine bone failure.

The objective of this study was to determine the influence of structural organization on the relationship between clinically assessed bone mineral density (BMD) and strength of trabecular bone. Accurate assessment of bone strength or fracture risk is a critical need as the population ages and the incidence of fractures increases. While ex vivo tests have demonstrated that BMD measured with dual-energy X-ray absorptiometry (DXA) correlates with failure load of whole bones, it is also known that the strength of trabecular bone cannot be explained by density alone. Cylindrical cores of bovine trabecular bone, harvested in a variety of orientations, were scanned with DXA to determine density, assessed with micro-MRI (magnetic resonance imaging) to measure orientation, and then loaded them to failure in bending. Measures of trabecular architecture included the angle between the specimen longitudinal (Z) axis and the principal material axis, the maximum mean intercept length (MILmax), the mean intercept length in the specimen primary axis (MILz), the degree of anisotropy, and the ratio between MILz and the length of the principal material axis. MILz was strongly associated with failure stress (r2 = 0.85, P < 0.001). BMD was also moderately associated with failure stress (r2 = 0.44, P = 0.004). Using a stepwise linear multiple regression analysis, the strongest predictor of failure stress was a combination of BMD, angle, and MILz (R2 = 0.91). When only longitudinal specimens were analyzed, the strongest predictor of failure stress was a combination of BMD and angle (R2 = 0.95). Therefore, trabecular orientation plays a significant and important role in failure of trabecular bone. Accounting for this may improve the associations between DXA-based density measures and patient fractures.

Absorptiometry, Photon↗

Semi-automatic segmentation of gated blood pool emission tomographic images by watersheds:application to the determination of right and left ejection fractions.

Tomographic multi-gated blood pool scintigraphy (TMUGA) is a widely available method which permits simultaneous assessment of right and left ventricular ejection fractions. However, the widespread clinical use of this technique is impeded by the lack of segmentation methods dedicated to an automatic analysis of ventricular activities. In this study we evaluated how a watershed algorithm succeeds in providing semi-automatic segmentation of ventricular activities in order to measure right and left ejection fractions by TMUGA. The left ejection fractions of 30 patients were evaluated both with TMUGA and with planar multi-gated blood pool scintigraphy (PMUGA). Likewise, the right ejection fractions of 25 patients were evaluated with first-pass scintigraphy (FP) and with TMUGA. The watershed algorithm was applied to the reconstructed slices in order to group together the voxels whose activity came from one specific cardiac cavity. First, the results of the watershed algorithm were compared with manual drawing around left and right ventricles. Left ejection fractions evaluated by TMUGA with the watershed procedure were not significantly different (p=0. 30) from manual outlines whereas a small but significant difference was found for right ejection fractions (p=0.004). Then right and left ejection fractions evaluated by TMUGA (with the semi-automatic segmentation procedure) were compared with the results obtained by FP or PMUGA. Left ventricular ejection fractions evaluated by TMUGA showed an excellent correlation with those evaluated by PMUGA (r=0. 93; SEE=5.93%; slope=0.99; intercept = 4.17%). The measurements of these ejection fractions were significantly higher with TMUGA than with PMUGA (P<0.01). The interoperator variability for the measurement of left ejection fractions by TMUGA was 4.6%. Right ventricular ejection fractions evaluated by TMUGA showed a good correlation with those evaluated by FP (r = 0.81; SEE = 6.68%; slope = 1.00; intercept = 0.85%) and were not significantly different (P = 0.42). The interoperator variability with TMUGA was 6.7% for the right ventricle. Thus, the watershed algorithm proposed is an efficient segmentation tool for the semi-automatic analysis of right and left ventricular ejection fractions by TMUGA. Further studies are necessary to check whether this procedure can be used to evaluate ventricular volumes and cardiac outflow.

Algorithms↗

Regional lean body mass and resting energy expenditure in non-obese adults.

OBJECTIVE: To study the effect of regional lean body mass (LBM) on resting energy expenditure (REE). Design Cross-sectional study in a homogenous group of 26 young healthy non-obese subjects. METHODS: Regional body composition was assessed by dual-energy X-ray absorptiometry (DEXA). REE was measured by indirect calorimetry. RESULTS: REE showed positive relationships with whole body LBM (LBMb; r=0.89) as well as with regional LBM (LBMtrunk = LBMt, r = 0.88, and LBMarms+legs = LBMe for LBMextremities, r = 0.89) with non-zero intercepts (between 1.86 and 2.83 MJ/d). REE per kg LBMb falls as LBMb increases (r = 0.77). By contrast, REE adjusted for regional distribution of LBM (i. e. the ratio of LBMt to LBMe) increases as LBMb increases (r = 0.91) showing a near-zero intercept (i. e. 0.048 MJ/d). Adjusting REE for LBMb as well as for the ratio of LBMt to LBMe can be used for comparison between subjects. CONCLUSIONS: Our data suggest that regional distribution of LBM is a determinant of REE. Assessment of LBMt and LBMe by DEXA provides a possibility to adjust for the non-linearity of REE on LBMb.

Absorptiometry, Photon↗

Skinfold thickness versus isotope dilution for body fat assessment during simulated microgravity: results from three bed-rest campaigns in men and women with and without countermeasures.

Because body composition is altered during head-down bed rest (HDBR), body mass can not be used as an index of energy balance. Consequently diet allowances should not be based on body mass evolution but on fat mass changes. Though criticized, skinfold thickness (ST) is the costless, easiest and fastest method to use for such an objective. The aim of this study was to compare the percentage of body fat (%BF) estimated by ST with the isotope dilution of H2 18O. We compiled data from three HDBR campaigns, one on women (n=8) in November 1998 and two on the same men (n=8) in December 1997 (without countermeasure) and January 1998 (with thigh-cuffs countermeasure), according to a crossover design. Body composition was assessed before and after 6 days of HDBR. %BF was derived from the biceps, triceps, sub-scapular and sup-iliac ST according to Durnin and Wormersly (1974). Fat-free mass was measured on the same day by H2 18O dilution and fat mass was calculated by the difference with body mass and expressed as a percentage. Based on precision tests, the minimum measurable change by ST was 1.1%BF for single measurement point. Both intercepts (F (4,30)=0.89, P=0.45) and slopes (F (4,30)=0.74; P=0.57) of the ST versus dilution relationships were not affected by the periods (December vs January), experimental conditions (control vs HDBR vs HDBR + thigh cuffs) or sex allowing the derivation of a common relationship %BF(st)=0.94 x %BF(dil) (F (1,47)=97.9, P<0.0001; non-significant intercept excluded) with a bias between methods of -1.7+/-2.0 %BF (95% CI: -5.8, 2.4 %BF). ST can be used to measure %BF during HDBR provided great care is placed on training and changes are higher than 1.1 %BF. If the method can be applied for in-flight energy balance monitoring given the high observed energy deficit, a tight monitoring of the individual nutritional status as needed during simulation appears, however, dubious based on this solely method.

Adiposity↗

Proton efflux in human skeletal muscle during recovery from exercise.

In recovery from exercise, phosphocreatine resynthesis results in the net generation of protons, while the net efflux of protons restores pH to resting values. Because proton efflux rate declines as pH increases, it appears to have an approximately linear pH-dependence. We set out to examine this in detail using recovery data from human calf muscle. Proton efflux rates were calculated from changes in pH and phosphocreatine concentration, measured by 31P magnetic resonance spectroscopy, after incremental dynamic exercise to exhaustion. Results were collected post hoc into five groups on the basis of end-exercise pH. Proton efflux rates declined approximately exponentially with time. These were rather similar in all groups, even when pH changes were small, so that the apparent rate constant (the ratio of efflux rate to pH change) varied widely. However, all groups showed a consistent pattern of decrease with time; the halftimes of both proton efflux rate and the apparent rate constant were longer at lower pH. At each time-point, proton efflux rates showed a significant pH-dependence [slope 17 (3) mmol x l(-1) x min(-1) x pH unit(-1) at the start of recovery, mean (SEM)], but also a significant intercept at resting pH [16 (3) mmol x l(-1) x min(-1) at the start of recovery]. The intercept and the slope both decreased with time, with halftimes of 0.37 (0.06) and 1.4 (0.4) min, respectively. We conclude that over a wide range of end-exercise pH, net proton efflux during recovery comprises pH-dependent and pH-independent components, both of which decline with time. Comparison with other data in the literature suggests that lactate/proton cotransport can be only a small component of this initial recovery proton efflux.

Adult↗

Leaf display and photosynthesis of tree seedlings in a cool-temperate deciduous broadleaf forest understorey.

To examine a possible convergence in leaf photosynthetic characteristics and leaf display responses to light environment in seedlings of three canopy and two shrub tree species in understorey of cool-temperate deciduous broadleaf forest, relationships between light environment, leaf orientation and leaf light-photosynthetic response were measured. Light capture of the seedlings (17-24 individuals with 2-12 leaves for each species) was assessed with a three dimensional geometric modeling program Y-plant. Leaf photosynthetic characteristics of the five species were found to have acclimated to the understorey light environment, i.e., low light compensation point and high apparent quantum yield. In addition, light-saturated photosynthetic rates were higher in seedlings inhabiting microsites with higher light availability. Efficiencies of light capture and carbon gain of the leaf display were evaluated by simulating the directionalities of light capture and daily photosynthesis for each seedling using hemispherical canopy photography. The results showed that most of the seedlings orientated their leaves in a way to increase the daily photosynthesis during the direct light periods (sunflecks) rather than maximize daily photosynthesis by diffuse light. Simulations also showed that daily photosynthesis would increase only 10% of that on actual leaf display when the leaves orientated to maximize the diffuse light interception. Simulations in which leaf orientations were varied showed that when the leaf display fully maximized direct light interception, the time that leaves were exposed to excessive photon flux density of >800 mumol photons m(-2) s(-1) were doubled. The understorey seedlings studied responded to the given light environments in a way to maximize the efficiency of acquisition and use of light during their short (approximately 3 month) seasonal growth period.

Computer Simulation↗