Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

A simple and rapid in situ preconcentration method for trace ammonia nitrogen in environmental water samples using a solid-phase extraction followed by spectrophotometric determination.

A simple and rapid in situ preconcentration method for the spectrophotometric determination of trace ammonia nitrogen in environmental water samples has been developed based on solid-phase extraction using a small column packed with octadecyl group-bonded silica gel (Sep-Pak C18 cartridge). A water sample was taken into a graduated syringe for easy and simple operation and prevention of contamination immediately after sample collection. Ammonia in the sample was reacted with hypochlorite and thymol to be converted into indothymol blue; then the formed indothymol blue was collected as an ion pair between indothymol blue and tetrabutylammonium ion on a Sep-Pak C18 cartridge. The indothymol blue on the cartridge was stable for 4 days. The retained indothymol blue was easily eluted with a mixture of methanol and 0.01 mol/l sodium hydroxide solution. The color intensity due to the indothymol blue was spectrophotometrically measured at 725 nm. The proposed method was successfully applied to environmental water samples such as river water.

Ammonia↗

Multiresidue method for the gas chromatographic determination of pesticides in honey after solid-phase extraction cleanup.

A new multiresidue method is described for the determination of pesticides in honey. The method involves dissolution of the honey in a methanol-water mixture, followed by solid-phase extraction cleanup and gas chromatographic determination. Twenty-six pesticides used on flowering field crops, on flowering fruit and vegetables, or as acaricides to control Varroa jacobsoni in beehives are determined by the method. Recoveries from honey, spiked at 0.02-1.6 mg/kg, ranged from 85 to 127% with a relative standard deviation (RSD) of 2-16%, except for the RSD of 27% for captan at 0.05 mg/kg.

Chromatography, Gas↗

Determination of carbofuran and its metabolites in rice paddy water by using solid phase extraction and liquid chromatography.

A procedure for the determination of carbofuran and its metabolites (carbamate and phenolic) in rice paddy water is described. Water samples are concentrated on a C-18 solid phase extraction (SPE) column and eluted with methanol-water. The eluate is analyzed by reverse-phase liquid chromatography (LC) and measured by a wavelength programmable ultraviolet (UV) detector. The limit of detection for the method is 0.4 micrograms/L. Recovery studies were carried out at levels ranging from 1 to 15 micrograms/L in both rice paddy water and distilled water; recoveries ranged from 85.9 to 112.9%.

Carbofuran↗

[Rapid identification and quantitation of barbiturates in plasma using solid-phase extraction combined with GC-FID and GC-MS method].

A rapid screening method for the quantitation and identification of 7 barbiturates in plasma is presented. The method employs solid-phase extraction at pH 3 using X-5 resin as absorbent. Identification of each barbiturate is achieved by retention time and GC-MS. Detection threshold (0.3-0.5 micrograms.ml-1 in a 0.5 ml plasma sample and 1 microliter injection volume), precision (RSD 3.46-6.41%), and linearity (r > 0.99) were satisfactory for blood level monitoring and clinical toxicological applications.

Barbiturates↗

Mechanism of peptide separations by solid phase extraction capillary electrophoresis at low pH.

A device for on-line extraction and concentration of peptides from a dilute sample matrix prior to direct capillary electrophoretic analysis is described. The technique, termed solid phase extraction capillary electrophoresis (SPE-CE), can facilitate analysis of peptides in the low nanograms per milliliter range. Peptides from a sample matrix are adsorbed on a reversed phase resin (C-8 or C-18) cartridge in-line with an uncoated fused-silica capillary and subsequently released for free zone electrophoresis by injection of an organic elutant. Unlike previous designs and commercially available packed-inlet capillaries, the device is easily constructed from common laboratory materials and is applicable to a wide range of conventional instrumentation and methods. This device and method has been developed for use in our laboratory as a stand-alone preparative technique, specifically to provide a second-dimensional orthogonal separation of biologically derived HPLC fractions of peptides in a single analysis. To this end, extensive effort was required in both device construction and method development to attain the successful separations which are reported in this study. Extractions of dilute peptide mixtures from sample injections exceeding, but not limited to, 20 times (48 microL) the capillary volume with apparent recovery greater than 80% are shown. The selectivity of extraction of individual components of a very dilute peptide mixture (31 ng/mL with 280 microL of sample injected) is presented. The ability to efficiently extract the individual peptides from the sample was found to be concentration-dependent for the individual peptide components over a 1600-field dilution of a common calibration mixture of nine model peptides. Varying the injected volume of elution buffer demonstrated the importance of minimizing the amount of buffer used to desorb peptides to maximize the resolution of individual peptides. This study highlights implementation for direct SPE-CE for peptide analysis and discusses for SPE tip-induced mechanism through which reversal in electoosmotic flow occurs.

Amino Acid Sequence↗

Solid phase extraction for an improved assay of physostigmine in biological fluids.

A simple, selective and very sensitive assay is described for the quantification of physostigmine in blood, plasma and urine. The most appropriate solid phase column was selected after a systematic investigation of nine types of phase. The conditions for solid phase extraction were optimized using [3H]physostigmine so that the overall recoveries were greater than 90%. Physostigmine was retained on alkaline treated cyanopropyl columns and eluted into the minimum volume of methanol, obviating the need for an evaporation step. Extracted samples were quantified by HPLC with a three electrode coulometric detection system. The limit of detection was 50 pg/mL for a 0.5 mL plasma sample. The precision (CV) for 0.5 mL plasma samples containing 50 pg was 8.1%. Application of the method to plasma, blood and urine samples is presented.

Chromatography↗

High-performance liquid chromatographic separation of ondansetron enantiomers in serum using a cellulose-derivatized stationary phase and solid-phase extraction.

R(-)-Ondansetron and S(+)-ondansetron in human serum were resolved and quantified using a stereospecific HPLC method. Each enantiomer and the internal standard prazosin were isolated from serum using a solid-phase extraction procedure on a cyanopropyl column. Recoveries of 97, 96 and 88% were obtained for the R(-)-enantiomer, the S(+)-enantiomer, and the internal standard, respectively. A cellulose-based chiral analytical column (Chiralcel OD) was used with a mobile phase consisting of hexane-95% ethanol-2-propanol-acetonitrile (65:25:10:1, v/v). Linear calibration curves were obtained for each enantiomer in serum in the concentration range 10-200 ng/ml. The limit of quantitation of each enantiomer was 10 ng/ml. The detection limit for each enantiomer in serum using UV detection at 216 nm was 2.5 ng/ml (signal-to-noise ratio of 3).

Cellulose↗

Determination of lomefloxacin in human plasma by solid-phase extraction and high-performance liquid chromatography with UV detection.

A high-performance liquid chromatographic method for the determination of lomefloxacin in human plasma has been developed and validated. A solid-phase extraction procedure was used to isolate lomefloxacin from the biological matrix prior to the quantitative analysis. The compound was separated on a Vydac anion-exchange column using acetonitrile-phosphate buffer (pH 7.0) as the mobile phase and quantified by measuring its UV absorbance at 280 nm. The lower limit of detection for the analyte was 0.05 micrograms ml-1. Enoxacin was used as the internal standard. The calibration graph of the method was linear from 0.1 to 10 micrograms ml-1 of lomefloxacin in human plasma. This procedure is suitable for pharmacological and pharmacokinetic studies of lomefloxacin.

Anti-Infective Agents↗

Quantitative determination of benzalkonium chloride in treated wood by solid-phase extraction followed by liquid chromatography with ultraviolet detection.

Ammoniacal copper quat (ACQ) compound wood preservative is comprised of copper and quaternary ammonium compounds with benzalkonium chloride (BAC) as the active ingredient. Solid-phase extraction (SPE) followed by liquid chromatography with ultraviolet detection (LC-UV) was developed for quantitative determination of BAC in treated wood. Five species of wood were used, Japanese cedar (Cryptomeria japonica), Japanese larch (Larix leptolepis), Yezo spruce (Picea jezoensis), Sakhalin fir (Abies sachalinensis), and western hemlock (Tsuga heterophylla). BAC used in the present study was composed of 66% C12, 33% C14 and less than 1% C16. BAC was added to each wood species (500 mg) then extracted with HCl-ethanol (20 ml) and quantitatively determined with LC-UV (262 nm). Wood extractives from the heartwood of each species, except western hemlock, interfered with quantitative determination of BAC, but SPE with an Oasis MCX cartridge was effective in preventing this. Using the present methods, BAC homologue peaks were clearly confirmed without interference. Recoveries from wood ranged from 92 to 101% and the limit of quantitation was approximately 240 microg/g wood for the C12 and C14 homologues.

Abies↗

Air sampling with Empore solid phase extraction membranes and online single-channel desorption/liquid chromatography/mass spectrometry analysis: determination of volatile and semi-volatile organophosphate esters.

A method for determining organophosphate esters in air samples using C8 Empore solid phase extraction (SPE) membranes has been developed. After the sampling the analytes trapped in the membrane are completely desorbed with methanol, using an extraction cell connected online to the organic modifier channel of a HPLC gradient pump. The addition of water to the mobile phase prior to analytical chromatography ensures that the analytes are refocused and efficiently separated. Sampling with Empore SPE membranes enables the collection of analytes in both the vapour phase and particulate matter. During the air sampling procedure no losses were observed after 24 h of sampling, yielding a total volume of 14.4 m3, even for the most volatile compound used in this investigation (trimethylphosphate). Complete desorption was observed for all the organophosphate esters and recoveries were greater than 95%, with a relative standard deviation of less than 8%. The limits of detection ranged between 0.4 and 19 pg/m3. The effect of particulate matter on the extraction efficiency was investigated in detail by spiking the membranes with reference standard material. It was also found that the SPE membranes could be stored for at least 5 days at room temperature without any evidence of loss. The efficacy of the method was verified using real samples from different common indoor environments. Interestingly, significant quantities of several phosphate esters were found in a NIST standard reference material (urban dust, SRM 1649a).

Air Pollutants↗

Simultaneous determination of the enantiomers of esmolol and its acid metabolite in human plasma by reversed phase liquid chromatography with solid-phase extraction.

A stereoselective RP-high performance liquid chromatography (HPLC) assay to determine simultaneously the enantiomers of esmolol and its acid metabolite in human plasma was developed. The method involved a solid-phase extraction and a reversed-phase chromatographic separation with UV detection (lambda = 224 nm) after chiral derivatization. 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate (GITC) was employed as a pre-column chiral derivatization reagent. The assay was linear from 0.09 to 8.0 microg/ml for each enantiomer of esmolol and 0.07-8.0 microg/ml for each enantiomer of the acid metabolite. The absolute recoveries for all enantiomers were >73%. The intra- and inter-day variations were <15%. The validated method was applied to quantify the enantiomers of esmolol and its metabolite in human plasma for hydrolysis studies.

Adrenergic beta-Antagonists↗

Determination of talinolol in human plasma using automated on-line solid phase extraction combined with atmospheric pressure chemical ionization tandem mass spectrometry.

A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.

Automation↗

Trace-level determination of polar flavour compounds in butter by solid-phase extraction and gas chromatography-mass spectrometry.

Volatile compounds are responsible for the aromas of butter. A simple technique for the determination of these components is described which is based on solid-phase extraction (SPE) after melting of the butter and separation of the aqueous phase from the fat. Volatile flavours present in the water fraction are collected by off-line SPE on cartidges packed with a copolymer sorbent. After desorption with 500 microliters of methyl acetate, 1-microliter aliquots are quantified and/or identified by gas chromatography-mass spectrometry. The procedure was tested with respect to recovery, linearity and limit of detection in real-life samples using five polar model analytes. It allows the characterisation of polar flavour compounds in butter prior to and after heat treatment at 170 degrees C. From the five model compounds, vanillin, traces of diacetyl and maltol were found to be present in the butter samples. After heat treatment 500-1000-fold increased concentration of maltol, and substantial amounts of furaneol were detected.

Benzaldehydes↗

Fifty years of solid-phase extraction in water analysis--historical development and overview.

The use of an appropriate sample handling technique is a must in an analysis of organic micropollutants in water. The efforts to use a solid phase for the recovery of analytes from a water matrix prior to their detection have a long history. Since the first experimental trials using activated carbon filters that were performed 50 years ago, solid-phase extraction (SPE) has become an established sample preparation technique. The initial experimental applications of SPE resulted in widespread use of this technique in current water analysis and also to adoption of SPE into standardized analytical methods. During the decades of its evolution, chromatographers became aware of the advantages of SPE and, despite many innovations that appeared in the last decade, new SPE developments are still expected in the future. A brief overview of 50 years of the history of the use of SPE in organic trace analysis of water is given in presented paper.

Water↗

On-line coupling of automated solid-phase extraction with high-performance liquid chromatography and electrochemical detection. Quantitation of oxidizable drugs of abuse and their metabolites in plasma and urine.

The concentration effect of automated on-line solid-phase extraction (SPE) in combination with HPLC and very sensitive electrochemical detection was employed for the determination of N-ethyl-4-hydroxy-3-methoxy-amphetamine (HMEA, the main metabolite of the ecstasy analogue MDE), delta 9-tetrahydrocannabinol (THC) and 11-nor-delta 9-tetrahydrocannabinol-carboxylic acid (THC-COOH) in plasma and urine in comparison to a previously published psilocin assay. For the SPE either CBA (functional group: carboxypropyl)- or CH (functional group: cyclohexyl)-sorbent was used. The following separation was carried out on a reversed-phase column (LiChroCart, Superspher 60 RP select B from Merck). Depending on the hydrodynamic voltammogram of the analyzed substance the oxidation potential varied from 920 mV up to 1.2 V. In spite of using high potentials, precision and accuracy were always within the accepted statistical requirements. The limits of quantitation were between 5 ng/ml (THC, THC-COOH in plasma) and 20 ng/ml (HMEA in plasma). Advantages of on-line SPE in comparison with off-line methods were less manual effort, evidently smaller volumes (< or = 400 microliters) of plasma or urine and almost always higher recovery rates (> 93%). The assays have been successfully proven with real biological samples and found suitable for use in routine analysis.

Amphetamines↗

An automatic 96-well solid phase extraction and liquid chromatography-tandem mass spectrometry method for the analysis of morphine, morphine-3-glucuronide and morphine-6-glucuronide in human plasma.

A bioanalytical method using automated sample transferring, automated solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed for morphine (MOR), and its metabolites morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) in human plasma. Samples of 0.25 ml were transferred into 96-well plate using automatic liquid handler (Multiprobe II). Automated SPE was carried out on a 96-channel programmable liquid handling workstation (Quadra 96) using a C(18) sorbent. The extract was injected onto a silica column using an aqueous-organic mobile phase. The chromatographic run time was 3.5 min per injection, with retention times of 1.5, 2.0 and 2.6 min for MOR, M6G, and M3G, respectively. The detection was by monitoring MOR at m/z 286-->152, M6G and M3G at m/z 462-->286. The deuterated internal standards were monitored at m/z 289-->152 for MOR-d(3), and m/z 465-->289 for M6G-d(3) and M3G-d(3). The standard curve range was 0.5-50 ng ml(-1) for MOR, 1.0-100 ng ml(-1) for M6G, and 10-1000 ng ml(-1) for M3G. The inter-day precision and accuracy of the quality control samples were <8% relative standard deviation (RSD) and <7% relative error (RE) for MOR, <5% RSD and <2% RE for M6G, and <2% RSD and <4% RE for M3G.

Automation↗

Solid-phase extraction of amphiphiles based on mixed hemimicelle/admicelle formation: application to the concentration of benzalkonium surfactants in sewage and river water.

The capability of surfactant-coated mineral oxides to aid the solid-phase extraction (SPE) of amphiphiles based on the formation of mixed hemimicelles/admicelles was investigated. The approach is illustrated by studying the adsolubilization of benzalkonium homologue (C(12), C(14), C(16)) surfactants (BAS) on sodium dodecyl sulfate (SDS)-coated alumina. These oppositely charged surfactants form mixed aggregates on alumina causing retention of BAS by strong hydrophobic and ionic interactions. The recovery of BAS was found quantitative and independent of the alkyl chain length under a wide range of experimental conditions (3-200 mg of SDS/g of alumina; pH 2-11; sample flow rate 3-20 mL/min, and sample loading volume 0.025-1 L). Anionic and nonionic surfactants and electrolytes did not interfere to the levels found in raw sewage. Combination of BAS adsolubilization-based SPE with liquid chromatography/electrospray ionization in positive ion mode/ion trap mass spectrometry permitted the quantification of BAS with detection limits of 4 ng/L and their identification by isolation and subsequent fragmentation in the ion trap. The approach developed was applied to the determination of BAS in raw and treated sewage and river samples. The concentrations of benzalkonium surfactants found ranged between 0.1 and 49 microg/L.

Journal Article↗

Highly sensitive and specific assay of plasma melatonin using high-performance liquid chromatography with fluorescence detection preceded by solid-phase extraction.

This paper describes a new, highly sensitive, rapid method for the determination of low levels of endogenous melatonin, the pineal and retinal hormone, in fish plasma samples. The combination of solid-phase extraction and high-performance liquid chromatography with fluorescence detection significantly improves the separation and increases the sensitivity of the assay. The proposed method may be a useful alternative to previously reported procedures. The assay should be applicable to plasma and tissue samples from other animals, including humans, with only minor modifications.

Animals↗