Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Separation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Separation of opiate alkaloids by electrokinetic chromatography with sulfated-cyclodextrin as a pseudo-stationary phase.

The separation of six related opiate alkaloids (morphine, thebaine, 10-hydroxythebaine, codeine, oripavine and laudanine) was studied using sulfated-cyclodextrin (s-CD) as a cation-exchange pseudo-stationary phase. Cation-exchange interactions between the cationic analytes and the anionic s-CD (7-11 mol of sulfate groups per mole CD) were found to bethe predominant mechanism, allowing the separations to be performed at low pH where the opiates are protonated and exhibit very similar mobilities. The concentrations of the s-CD and the competing ion (Na+ or Mg2+) in the electrolyte were used to govern the extent of the ion-exchange interactions. Interactions with the sulfated-cyclodextrin differed for each analyte, with oripavine exhibiting the strongest interaction and 10-thebaine and laudanine showing the weakest interactions. Despite the very similar structures of the analytes, these differences resulted in significant changes in separation selectivity. The separation was modelled using a migration equation derived from first principles and based on ion-exchange interactions between the s-CD and the opiates. Constants within the model were obtained by non-linear regression using a small subset of experimentally determined migration times. These constants related to the ion-exchange affinities of the s-CD for the various opiates. When the model was used to predict migration times under other experimental conditions, a very good correlation was obtained between observed and predicted mobilities (r2=0.996). Optimisation of the system was performed using the normalised resolution product and minimum resolution criteria and this process provided two optimised separations, each exhibiting a different separation selectivity.

Alkaloids↗

Co-eluent effect in partition chromatography. Rhamnose-xylose separation with strong and weak cation-exchangers in aqueous ethanol.

The effect of ethanol in aqueous eluent on the chromatographic separation was studied at 298 K. Two sugars, L-rhamnose and D-xylose, were separated by using strong and weak cation-exchangers as a stationary phase. The ionic form of the resins was Na+ or Ca2+. The separations were carried out with sugar feed concentrations up to 35 wt% and with both low (about 1%) and high (about 10%) feed volume to bed volume ratios. The separation of the sugars was improved by adding ethanol into the eluent. The separation was also significantly enhanced when the weak cation-exchangers with the greatest affinity for water were used instead of strong cation-exchangers as a separation medium for the sugars having different hydrophilicities. The experimental data were successfully explained with a rate-based column model, which accounted for the volume changes of the stationary phase. A thermodynamic sorption model was utilized in column calculations.

Adsorption↗

Role of buffer concentration and applied voltage in obtaining a good separation in planar electrochromatography.

Planar electrochromatography is performed by applying an electric field across a thin layer chromatography (TLC) plate. In addition to electroosmotic flow in the axial direction, there is also flow to the surface of the TLC layer, and this can substantially degrade the quality of separation. This effect is offset by Joule heating which causes evaporation of liquid from the layer surface, and which under some conditions causes degradation of separation quality by excessive drying of the layer. It is shown that pH, buffer concentration, and applied voltage control the balance between liquid being driven to the surface and liquid evaporating from the surface due to Joule heating. Conditions are discussed which result in good separation quality, or in separations degraded by either excessive wetting or drying of the layer. The above separations were performed at constant voltage. A chromatogram is presented that shows that a good separation is also obtained at constant power, i.e. under conditions where there is a constant amount of Joule heating.

Buffers↗

Determination of the interconversion energy barrier of enantiomers by separation methods.

Separation methods have become versatile tools for the determination of kinetic activation parameters and energy barriers to interconversion of isomers and enantiomers in the last 20 years. New computer-aided evaluation systems allow the on-line determination of these data after separating minute amount of pure compounds or mixture of isomers or enantiomers, respectively. Both dynamic interconversion during the separation process as well as static stopped-flow techniques have been applied to determine the kinetic activation parameters and interconversion energy barriers by separation methods. The use of (1) combinations of batchwise kinetic studies with enantioselective separations, (2) a continuous flow model, (3) a comparison of real chromatograms with simulated ones, (4) stopped-flow techniques, (5) stochastic methods, (6) approximation functions and (7) deconvolution methods, for the determination of interconversion energy barriers by separation methods is summarized in detail.

Kinetics↗

Simultaneous separation of inorganic anions and cations by using anion-exchange and cation-exchange columns connected in tandem in ion chromatography.

Inorganic anions and cations in environmental waters were determined by ion chromatography. Stationary and mobile phases were examined for the simultaneous separation of both anions and cations. Cations detection by UV detection requires a mobile phase with a UV absorbing additive, which indirectly visualizes cations as negative peaks. Simultaneous separation of anions and cations were achieved when using an eluent that consists of inorganic acid with weak basic amino acid as additives. It was convenient to separate both anions and cations by coupling anion-exchange and cation-exchange columns in tandem. The order of the separation columns connected affected the elution profiles. When the eluent comprises of multiple anions and a single cation, the anion-exchange column should be connected in the upper stream, whereas when the eluent comprises multiple cations and a single anion, the cation-exchange column should be connected in the upper stream. Use of switching valves also allowed simultaneous separation of anions and cations in a single chromatographic run. In the present work, operating conditions were optimized for the simultaneous separation of anions and cations.

Anion Exchange Resins↗

The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis.

The use of mass spectrometry based on atmospheric pressure ionisation techniques (atmospheric pressure chemical ionisation, APCI, and electrospray ionisation, ESI) for speciation analysis is reviewed with emphasis on the literature published in and after 1999. This report accounts for the increasing interest that atmospheric pressure ionisation techniques, and in particular ESI, have found in the past years for qualitative and quantitative speciation analysis. In contrast to element-selective detectors, organic mass spectrometric techniques provide information on the intact metal species which can be used for the identification of unknown species (particularly with MS-MS detection) or the confirmation of the actual presence of species in a given sample. Due to the complexity of real samples, it is inevitable in all but the simplest cases to couple atmospheric pressure MS detection to a separation technique. Separation in the liquid phase (capillary electrophoresis or liquid chromatography in reversed phase, ion chromatographic or size-exclusion mode) is particularly suitable since the available techniques cover a very wide range of analyte polarities and molecular mass. Moreover, derivatisation can normally be avoided in liquid-phase separation. Particularly in complex environmental or biological samples, separation in one dimension is not sufficient for obtaining adequate resolution for all relevant species. In this case, multi-dimensional separation, based on orthogonal separation techniques, has proven successful. ESI-MS is also often used in parallel with inductively coupled plasma MS detection. This review is structured in two parts. In the first, the fundamentals of atmospheric pressure ionisation techniques are briefly reviewed. The second part of the review discusses recent applications including redox species, use of ESI-MS for structural elucidation of metal complexes, characterisation and quantification of small organometallic species with relevance to environment, health and food. Particular attention is given to the characterisation of biomolecules and metalloproteins (metallothioneins and phytochelatins) and to the investigation of the interaction of metals and biomolecules. Particularly in the latter field, ESI-MS is the ideal technique due to the softness of the ionisation process which allows to assume that the detected gas-phase ions are a true representation of the ions or ion-biomolecule complexes prevalent in solution. It is particularly this field, important to biochemistry, physiology and medical chemistry, where we can expect significant developments also in the future.

Atmospheric Pressure↗

Protein separation by nonsynchronous coil planet centrifuge with aqueous-aqueous polymer phase systems.

Counter-current chromatographic separation of proteins was performed using a rotary-seal-free nonsynchronous coil planet centrifuge (CPC) fabricated in our laboratory. This apparatus has a unique feature that allows a freely adjustable rotational rate of the coiled separation column at a given revolution speed. The separation was performed using a set of stable proteins including cytochrome c, myoglobin and lysozyme with two different types of aqueous-aqueous polymer phase systems, i.e., PEG (polyethylene glycol) 1000-dibasic potassium phosphate, and PEG 8000-dextran T500 in 5 mM potassium phosphate buffer. Using a set of multilayer coiled columns prepared from 0.8 mm I.D. PTFE tubing with different volumes (11, 24, 39 ml), the effect of the column capacity on the partition efficiency was investigated under a given set of experimental conditions. Among these experiments, the best separation of proteins was attained using the 39 ml capacity column with a 12.5% (w/w) PEG 1000-12.5% (w/w) dibasic potassium phosphate system at 10 rpm of coil rotation under 800 rpm. With lower phase mobile at 0.2 ml/min in the head-to-tail elution, the resolution between cytochrome c and myoglobin was 1.6 and that between myoglobin and lysozyme, 1.9. With upper phase mobile in the head-to-tail elution, the resolution between lysozyme and myoglobin peaks was 1.5. In these two separations, the stationary phase retention was 35.0 and 33.3%, respectively. Further studies were carried out using a pair of eccentric coil assemblies with 0.8 mm I.D. PTFE tubing at a total capacity of 20 ml. A comparable resolution was obtained using both lower and upper phases as a mobile phase in a head-to-tail elution. The results of our studies demonstrate that the nonsynchronous CPC is useful for protein separation with aqueous-aqueous polymer phase systems.

Centrifugation↗

Capillary electrophoretic separation of heparin oligosaccharides under conditions amenable to mass spectrometric detection.

A capillary electrophoresis method for the separation of high-molecular-mass heparin oligosaccharides compatible with mass spectral detection was developed. Structurally defined heparin oligosaccharides ranging in size from tetrasaccharide to tetradecasaccharide were used to optimize the conditions. Applying normal and reversed polarity modes, these oligosaccharides were separated by CE under various conditions. Ammonium hydrogencarbonate (30 mM at pH 8.50) used as the running electrolyte system gave good separation efficiency and resolution in the normal polarity mode. Application of this method to the separation of complicated heparin oligosaccharide mixtures required the addition of electrolyte additives. Ammonium hydrogencarbonate (30 mM), containing triethylamine (10 mM), was useful for the separation of complex oligosaccharide mixtures. Run-to-run and day-to-day precision and limits of detection were established for these separations.

Electrophoresis, Capillary↗

Fast DNA separations using poly(ethylene oxide) in non-denaturing medium with temperature programming.

We demonstrated fast DNA separations in low viscosity entangled solutions with a temperature gradient in a non-denaturing separation medium. The separations were carried out in a solution of commercially available poly(ethylene oxide) (PEO) [1 x Tris(hydroxymethyl)aminomethane borate buffer, without urea] with a temperature gradient of 2 degrees C/min. The performance was compared with that of a solution of PEO with urea at ambient temperature. We found that the former condition gives sufficient resolution for accurate base calling and that in general, it gave better separation for fragments larger than 450 base pairs (bp). Most importantly, the separation speed approaches 30 bp/min. In addition, we describe a simple yet reliable gel preparation protocol for such separations.

Base Sequence↗

Supercritical fluids in separation science--the dreams, the reality and the future.

The last 20 years have seen an intense interest in the use of supercritical fluids in separation science. This started with the introduction of commercial instruments first for packed and then for capillary chromatography and it looked as if this would be a technique to rival gas-liquid chromatography and HPLC. The activity developed quite rapidly into packed column supercritical fluid separations then into supercritical fluid extraction. However, in recent years there has been a decline in publications. These later techniques continue to be used but are now principally applied to a limited group of applications where they offer significant advantages over alternative techniques. This review looks back over this period and analyses how these methods were developed and the fluids, detectors and applications that were examined. It suggests why many of the initial applications have vanished and why the initial apparent promise was not fulfilled. The rise and fall of supercritical fluids represents a lesson in the way analysts approach new techniques and how we might view other new separation developments at the end of this millennium. The review looks forward to the future of supercritical fluids and their role at the end of the first century of separation science. Probably the most important idea that supercritical fluids have brought to separation science is a recognition that there is unity in the separation methods and that a continuum exists from gases to liquids.

Chromatography↗

Anion-exchange separation and determination of bisphosphonates and related analytes by post-column indirect fluorescence detection.

Bisphosphonic acids and their salts can be detected after their liquid chromatographic separation by post-column indirect fluorescence detection (IFD). After separation the analyte is combined with the highly fluorescent Al(3+)-morin (2',3,4',5,7-pentahydroxyflavone) solution and fluorescence decreases because of the formation of the nonfluorescent Al(3+)-bisphosphonate complex. The decrease in fluorescence is proportional to the amount of bisphosphonate present. Separation of the multivalent anionic bisphosphonate analytes from other anions and sample matrix is achieved on a strong base anion-exchange column with a strong, basic eluent. The post-column reaction variables, which influence IFD, are identified and optimized for the detection of the bisphosphonates after separation on the anion exchanger. The method is selective, since only a few anions will undergo a reaction with the Al(3+)-morin solution, and sensitive, detection limit for difluoromethylene bisphosphonate, F2MDP, is 4 ng for S/N = 3. The separation-IFD method can be applied to the determination of bisphosphonates, such as F2MDP, ethane-1-hydroxy-1,1-bisphosphonic acid, dichloromethylene bisphosphonic acid, 4-amino-1-hydroxybutane-1,1-bisphosphonic acid, in biological samples. The separation-IFD method is also applicable to the detection of inositol phosphate anions.

Chromatography, Ion Exchange↗

Migration behavior and separation of benzenediamines, aminophenols and benzenediols by capillary zone electrophoresis.

The migration behavior and separation of five benzendiamines, five aminophenols and three benzenediols were investigated in capillary zone electrophoresis. The results indicate that benzendiamines and aminophenols are optimally separated with a phosphate buffer at pH 5, whereas benzenediol isomers are best separated at pH about 12. The addition of surfactant monomers of tetradecyltrimethylammonium bromide to a phosphate buffer at pH 5 under the conditions of reversed electroosmotic flow is effective for separating these dye intermediates, except for the separation of 1,2-benzenediol from 1,3-benzenediol. The addition of sodium tetraborate as an electrolyte modifier is effective in the separation of 1,2-benzenediol from 1,3-benzenediol, but the latter comigrates with the 1,4-benzenediol isomer at pH 5.0. The electrophoretic mobility of ionized analytes can be described with Offord's equation, and the migration order depends on their ratios of charge to mass. In addition, the pKa values of these analytes in 50 mM phosphate buffer are reported.

Aminophenols↗

Separation of isomeric naphthalenesulphonic acids by micro high-performance liquid chromatography with mobile phases containing cyclodextrin.

Aromatic sulphonic acids are important dye intermediates and the determination of the individual isomers after their preparation by sulphonation of the parent aromatic hydrocarbon is important for the monitoring of the dye production process. For this purpose, either reversed-phase chromatography with mobile phases containing strong electrolytes as additives or capillary zone electrophoresis with working electrolytes containing cyclodextrins can be used to separate and determine not only individual sulphonation products with various numbers of sulphonic groups, but also various isomeric di- and trisulphonic acids. However, the separation of some isomers using either of the two techniques is not fully satisfactory. In the present work, HPLC with mobile phases containing cyclodextrins was employed to improve previously achieved separations of aromatic sulphonic acids. Because of the high cost of cyclodextrin, microcolumn HPLC with diode-array detection on the columns prepared in laboratory by supercritical fluid packing technique was employed for this purpose. Capillary columns packed with various octadecyl silica gel materials were compared and their stability and efficiency were found suitable for the separation of the compounds tested. The selectivity of separation of some isomers improved significantly with respect to the previous methods. Procedures were designed for separation and analytical control of technological processes producing dye intermediates.

Chromatography, High Pressure Liquid↗

Separation of enantiomers by capillary electrophoresis-mass spectrometry employing a partial filling technique with a chiral crown ether.

Enantiomer separations were performed by capillary electrophoresis-mass spectrometry (CE-MS) with (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid (18C6H4) as a chiral selector. In order to prevent the introduction of the nonvolatile chiral, selector, 18C6H4, into the nozzle of the CE-MS interface and/or the orifice plate, a partial filling technique was employed in this study. By the partial filling technique, the contamination caused by the nonvolatile chiral selector was avoided not only during the analysis but also during the washing of capillary with the separation solution prior to the run. Several racemic compounds having a primary amino group were successfully separated. Racemic 3-aminopyrrolidine and racemic alpha-amino-epsilon-caprolactam have no strong UV absorption, but such compounds were detected with a high sensitivity by MS detection. In this paper, the effects of the length of separation zone and those of the 18C6H4 concentration were described. As the length of the separation zone was longer or as the concentration of 18C6H4 was higher, the enantiomer resolution was enhanced more and more. However, the optimization of 18C6H4 concentration was practically enough to obtain the baseline separation.

Electrophoresis, Capillary↗

Amnion-chorion separation after 17 weeks' gestation.

OBJECTIVE: To evaluate the cause of and perinatal outcomes of amnion-chorion separation that is apparent sonographically after 17 weeks' gestation. METHODS: We searched our ultrasound database over 7 years for information on pregnant women who had live fetuses and complete separation between amnion and chorion that persisted beyond 17 weeks' gestation. For inclusion in the study, the women had to have amnion separated from chorion on at least three sides of the gestational sac. Medical records were reviewed for whether women had amniocenteses, results of the amniocenteses, and outcomes of the pregnancies. RESULTS: Of 15 pregnant women with live fetuses, ten had amniocenteses before identification of amnion-chorion separation and five did not. Three had fetuses with Down syndrome, two of whom had amnion-chorion separation evident before amniocentesis, and all three had other sonographic findings suggestive of aneuploidy. Three fetuses died. The other pregnancies were complicated by one or more adverse events, including two fetuses with growth restriction, five preterm deliveries, two with oligohydramnios, and one with abruptio placentae. Five infants were delivered at term and are alive and well. Overall, ten of 15 pregnancies resulted in live newborns, one of whom had Down syndrome. CONCLUSION: Complete amnion-chorion separation that persisted after 17 weeks' gestation is associated with a variety of adverse perinatal outcomes, including aneuploidy.

Extraembryonic Membranes↗

Effect of maternal separation on feeding behavior of rats in later life.

Effects of maternal separation on feeding behavior, particularly on rebound hyperphagia, in adult rats were examined. Time-restricted scheduled feeding (2 h per day for 6 days), was given at the age of 3, 6, 9 or 12 weeks in rats that were maternal separated from postnatal days (PD) 1-21 and control rats. Following the time-restricted scheduled feeding, rats were fed freely for 24 h (rebound hyperphagia). Body weight, daily normal food consumption and food consumption during time-restricted scheduled feeding and rebound hyperphagia were measured. Body weight of 3-week-old maternally separated rats were less than those of control rats. There was no significant difference in normal daily food consumption. Food consumption during rebound hyperphagia was significantly increased in 6- to 9-week-old female maternally separated rats, but there was no difference observed in males. Postnatal maternal separation enhanced rebound hyperphagia of female rats in later life. These results indicate that postnatal maternal separation made rats more vulnerable to the development of abnormal feeding behavior in response to food restriction in later life.

Aging↗

Juvenile friends, behavior, and immune responses to separation in bonnet macaque infants.

Individual differences in the response to maternal separation in nonhuman primate infants have been attributed to (among other variables) presence or absence of processes that may model social support in humans. Alternative attachments to other members of the social group buffer the infant against a depressive response to maternal separation. This hypothesis was tested in a group of bonnet macaques by manipulating the presence or absence of alternative juvenile attachment figures (friends) during separation. Infants who retained such attachments showed fewer behavioral evidences of depression when separated from their mothers. These infants without friends also showed changes in lymphocyte activation by mitogens or natural cytotoxicity that were not evident in the infants with juvenile friends. Across all separated infants, natural cytotoxicity was positively correlated with juvenile affiliative behavior directed toward the infants during the separation. These results support the hypothesis that social support, available from alternative attachments, can modulate the response to loss, and can account for some of the individual differences seen in these responses.

Animals↗

Conjunction and linear non-separability effects in visual shape encoding.

Four visual search experiments are reported which used simple 2D shapes varying on the global dimensions of aspect ratio/curvature or aspect ratio/tapering. Results indicate serial self-terminating search in all conditions. Most importantly, search rates are markedly modulated by the particular forms of structural relations existing between the targets and their distractors. Thus, single-feature targets with shape properties that are linearly separable from those of their distractors yield markedly faster search rates than linearly separable targets made of a conjunction of distractor features. In addition, linearly separable single-feature targets are searched at a much faster rate than single-feature targets which are not linearly separable. Follow-up experiments demonstrate that these conjunction and linear non-separability effects cannot be attributed to pairwise target-distractor discriminability differences across conditions. The main conclusions are that the shapes used are parsed according to elementary features in visual encoding, and that a linear discrimination mechanism is available which permits fast visual search rates if a single-feature target is linearly separable from its distractors.

Adult↗