Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Endotoxin binding by charged and uncharged resins.

Cholestyramine (Dowex 1-X2), a strongly basic anion-exchange resin, has previously been shown to bind bacterial endotoxin, preventing both its toxicity and intestinal absorption. Because hemoperfusion through charged and uncharged resins is practical, a study was undertaken to test the endotoxin-binding characteristics of a number of resins. The resin to be tested was washed and swelled overnight, and 1 mg/ml of 51Cr-labeled endotoxin was added and the mixture, agitated and incubated at 37 degrees for a specific time period. In the Dowex 1 series, the 1-X2 was superior to the 1-X4 and 1-X8 in its ability to bind E. coli endotoxin, removing about 90% from solution in 15 min. Increasing mesh size seemed to offer more binding sites for each Dowex 1 resin. Activated charcoal adsorbed about 90% of the endotoxin also, but Amberlite XAD-2 showed little binding capacity. Injection of filtrate from unlabeled E. coli and S. typhosa resin-treated solution into rats, demonstrated that both Dowex 1-X2 and activated charcoal prevented the transaminase rise noted in animals injected with solutions not so treated. It is concluded that Dowex 1-X2 resin and activated charcoal efficiently remove endotoxin in vitro, and may offer a unique method for removing circulating endotoxin in vivo.

Alanine Transaminase↗

[Studies on analysis of terpene resin in imported chewing gums].

We have developed an analytical method for terpene resins in chewing gum. The fraction including terpene resins was prepared by means of hexane extraction and two silica gel column chromatography treatments (hexane and ethyl acetate) from chewing gum. The terpene resin fraction was analyzed with LC/MS and IR. The terpene resins are mixtures of polymeric pinene and/or limonene, which have a monomer molecular weight of 136. The MS spectrum of the terpene resin peak on the LC/MS total ion chromatogram showed protonated molecular ion (M + H)+ peaks at intervals of m/z 136, characteristic of a complex mixture of polyterpenes. IR spectroscopy is a suitable technique to identify the terpene resin type, ie., pinene or limonene. When the method was applied to imported chewing gum sold in Japan, terpene resins were clearly detected.

Chewing Gum↗

[Preconcentration of trace chalcophile elements by a zincon--loaded resin and its application to neutron activation analysis (author's transl)].

A chelating agent-loaded resin consisting of an anion exchange resin and zincon which has widely been employed as a specific reagent for zinc(II) and copper(II) in spectrophotometry was prepared. The adsorption behavior of some chalcophile elements was studied in detail, with respect to pH, flow rate and exchange capacity. From the results, it was confirmed that the zincon-loaded resin reacts selectively with copper(II), zinc(II), mercury(II) and lead(II) at lower pH region, and the above reaction is stoichiometric as in the case of the reaction of zincon with metal ions in aqueous solution. Furthermore, the zincon-loaded resin was applied to the selective concentration of trace amounts of chalcophile elements in natural water samples prior to neutron activation analysis. Water samples taken from the Watarase River were filtered and the pH of each filtrate was adjusted to ca. 5.5. After preconcentration was made by the column method (zincon-loaded resin: 2 x 10-4 mol/g resin, 1.0 g, 7 mm phi x 35 mm), the resin in the column was washed and dried in a desiccator. The standard material was also prepared according to the above mentioned scheme. The sample and the standard materials packed in polyethylene vials were irradiated for 40 min by a neutron flux of 5 x 10(13 n.cm-2.sec-1 in the JRR-4 of the Japan Atomic Energy Research Institute. After cooling the materials, activity measurements were made. The results were 53 ppb for copper, 0.25 ppb for mercury.

Activation Analysis↗

Effect of adding ethylene glycol dimethacrylate to resin cements: durability against thermal stress of adhesion to titanium.

The present study was conducted to examine the effect of the addition of a dimethacrylate to resin cements on bond strength between titanium and resin after thermocycling. Titanium disks, polished and treated with a phosphate monomer, were bonded to acrylic rods using two types of experimental resin cements. The cements were composed of methyl methacrylate (MMA) containing a tributylborane initiator and 0-10 wt% of ethylene glycol dimethacrylate (EGDMA) and two types of polymer component of hard poly (MMA) or soft fluoropolymer (2-6F). The bonded specimens were subjected to a thermocycling test in water and then to tensile strength testing. The addition of 5% or more dimethacrylate monomer to the two MMA-based resin cements caused a drastic decrease in bond strength to the metal after the thermocycling test. The resin prepared with soft 2-6F as a polymer component was significantly more durable than the rigid type resin based on PMMA. However, even a 1% addition of ECDMA to the 2-6F resin resulted in a significant decrease in durability.

Analysis of Variance↗

Discrimination between composite resin and teeth using fluorescence properties.

The differentiation of composite resin from teeth using fluorescence emission was investigated as basic research for the visual detection of resin filled teeth in mass dental health examinations. Fluorescence spectra were taken from extracted human maxillary central incisors and 12 types of light-cured composite resins with a maximum of 15 shades via excitation using light with wavelengths of 400-500 nm. The fluorescence intensity ratio of resin to tooth was lowest around 500 nm for all the resins. The fluorescent images were taken based on spectroscopic results, which confirmed discrimination between the resin part and the tooth in the resin filled tooth.

Color↗

[Comparison between physical properties of resin materials and those of gypsum materials for dental models and dies (author's transl)].

Setting time, water sorption, solubility, dimensional change, hardness, tensile strength, compressive strength, bending strength, and Young's modulus of resin model materials and gypsum model materials were determined. These results are following: 1) Setting time of Goldex is in general the same as that of dental plaster, and setting time of Alpha-Die and that of Dicodur are the same as densite type stone. But setting time of Rock Model is very long, that is, ten times as long as that of densite type stone. 2) Water sorption and solubility of gypsum model materials are larger than those of resin model materials. Solubility of Dicodur is larger in comparison with the other resin model materials. 3) During setting, all of gypsum model materials expand but all of resin model materials contract. The absolute values of dimensional change of Rock Model and of densite type stones are the same, but smaller compared with those of other materials. 4) The value of knoop hardness of resin model materials is between that of plaster of Paris and that of hydrocal type stones. 5) In comparison with densite type stone, resin model materials are 2.5 to 5.0 times in tensile strength, the same in compressive strength, and 1.5 to 2.3 times in bending strength. 6) Young's modulus of resin model materials is 1/3 to 1/5 as much as that of densite type stones.

Calcium Sulfate↗

On composite resin materials. Degradation, erosion and possible adverse effects in dentists.

PURPOSE: The aims of this thesis were: 1. To study the effect of water and pH on composite resin materials in vitro by assessing sorption, solubility, monomers eluted and flexural properties. 2. To study adverse effects on the skin in dentists possibly caused by acrylic resin-based materials. MATERIALS AND METHODS: Proprietary composite resin materials were used for the in vitro experiments. The tests were performed according to the ISO 4049 (1988) with the exception of McIlvaine's solution used in Study II and the storage times. The analysis of eluted monomers was performed using HPLC. The flexural properties were tested in a three-point bending equipment. The secant modulus and deflection at break were calculated for description of the viscoelastic behaviour of the material tested. To study the adverse effects on skin in dentists, a questionnaire was sent to 3500 randomly selected Swedish dentists. A response rate of 88% was achieved and the data were statistically analysed and compared with the results of two studies on skin symptoms among the general Swedish population. Dentists living in the three main cities in Sweden who had experienced hand eczema during the last 12 months were invited to a clinical examination in which a patch test was included. RESULTS: A wide range in sorption and solubility over the test period was found, with low sorption values observed for materials containing hydrophobic matrix monomers. A maximum concentration of monomers eluted was found after 7 days of storage, and TEGDMA was the main monomer released. pH affected the sorption and solubility behaviour for two of the three materials tested. The flexural strength and modulus of the composite resin material were lowered after water storage and the secant modulus and deflection at break could describe the viscoelastic behaviour. The prevalence of dry skin and hand eczema was high in dentists compared to two age-matched general population samples investigated using identical questions. The most important predictor for adult hand eczema was found to be childhood eczema. At the clinical examination, irritant contact dermatitis was the predominant diagnosis. Seven per cent reported skin symptoms when working with acrylic resin-based material but the true prevalence of hand eczema caused by acrylates was below 1%. Contact allergy was diagnosed, however, in 50% of the dentists, mainly due to other allergens such as nickel, perfumes or rubber chemicals. CONCLUSIONS: The matrix composition was shown to be important for the sorption and solubility behaviour of the composite resin materials tested and a maximum release of monomers occurred after 7 days of storage. pH affected the water sorption and solubility behaviour. Calculation of the secant modulus and the deflection at break allowed the plasticising effect of water on composite resin material to be observed. The prevalence of hand eczema was high among dentists, with irritant contact dermatitis as the predominant diagnosis. Childhood eczema was the most important predictor for adult hand eczema. The prevalence of hand eczema owing to acrylates was below 1%.

Adsorption↗

An investigation of heat transfer to the implant-bone interface related to exothermic heat generation during setting of autopolymerizing acrylic resins applied directly to an implant abutment.

Excessive heat generation at the implant-bone interface may cause bone damage and compromise osseointegration. Autopolymerizing acrylic resins are commonly used intraorally to join impression copings and suprastructure components for soldering. The effect of heat generation at the implant surface related to the exothermic setting reaction of autopolymerizing acrylic resins applied to an attached abutment was examined in vitro. Two brands of autopolymerizing acrylic resin, Duralay and GC Pattern Resin, were compared. Acrylic resin was applied to a titanium alloy abutment connected to a titanium alloy cylindric implant in varying controlled volumes, with both bulk application and brush paint-on techniques. The implant was embedded in an acrylic resin mandible in a 37 degrees C water bath. Temperature changes were recorded via embedded thermocouples at the cervical and apical of the implant surface. Analysis of variance for repeated measures was used to compare treatment groups. A mean maximum increase in temperature of 4 to 5 degrees C was seen at the implant cervical for both materials, with a maximum temperature increase of 6 degrees C. No difference between Duralay and GC Pattern Resin was seen, except for bulk application to medium-sized copper bands at the implant cervical (P < .05). No difference between the bulk and brush techniques was seen for all options, except for GC, where bulk application to medium-sized copper bands produced higher temperatures than the brush technique (P < .05). Spray coolant reduced temperatures for bulk application of both Duralay and GC (P < .05).

Acrylic Resins↗

Dynamic viscoelastic properties of models composed of posterior denture teeth and denture base resin.

The purpose of this investigation was to compare the dynamic viscoelastic properties of various models composed of denture teeth and heat-cured denture base resin. The specimens were porcelain and resin teeth mounted in denture base resin. Compressive dynamic stiffness and phase differences were measured with a viscoelastic spectrometer. Measurements of the viscoelastic frequency spectrum based on the fast Fourier transform of displacement to applied random forces were analyzed with a spectrum analyzer. The stiffness of the specimens was independent of the frequency. The stiffness of the porcelain specimens was higher than that of the resin ones measured under the same conditions. The phase lag of the specimens was dependent on the frequency. The phase lag of the porcelain specimens was lower than that of the resin ones measured under the same conditions. This study suggested that the acrylic resin teeth had greater toughness and higher shock-absorbing ability than the porcelain teeth, and that the porcelain teeth were more brittle than the acrylic resin ones, whether the teeth were isolated or in dentures.

Acrylic Resins↗

Fiber reinforced composite resin systems.

The Targis/Vectris and Sculpture/FibreKor systems were devised to create a translucent maximally reinforced resin framework for fabrication of crowns, bridges, inlays, and onlays. These materials are esthetic, have translucency similar to castable glass-ceramics such as OPC and Empress, and have fits that are reported to be acceptable in clinical and laboratory trials. These restorations rely on proper bonding to the remaining tooth structure; therefore, careful attention to detail must be paid to this part of the procedure. Cementation procedures should involve silane treatment of the cleaned abraded internal restoration surface, application of bonding agent to the restoration as well as the etched/primed tooth, and finally use of a composite resin. Each manufacturer has a recommended system which has been tested for success with its resin system. These fiber reinforced resins are somewhat different than classical composites, so not all cementation systems will necessarily work with them. Polishing of the restoration can be accomplished using diamond or alumina impregnated rubber wheels followed by diamond paste. The glass fibers can pose a health risk. They are small enough to be inhaled and deposited in the lungs, resulting in a silicosis-type problem. Therefore, if fibers are exposed and ground on, it is extremely important to wear a mask. Also, the fibers can be a skin irritant, so gloves also should be worn. If the fibers become exposed intraorally, they can cause gingival inflammation and may attract plaque. The fibers should be covered with additional composite resin. If this cannot be accomplished, the restoration should be replaced. The bulk of these restorations are formed using a particulate filled resin, similar in structure to conventional composite resins. Therefore, concerns as to wear resistance, color stability, excessive expansion/contraction, and sensitivity remain until these materials are proven in long-term clinical trials. They do hold the promise of minimizing tooth reduction and may be particularly useful in preserving sound tooth structure. Although not the primary intended use, an excellent application is long-term temporization, such as for patients requiring full mouth rehabilitation. The belleGlass/Connect, Ribbond, and GlasSpan materials rely on nonimpregnated polyethylene fibers which have mechanical properties inferior to Vectris and FibreKor. These fibers may be used to greater success as splinting materials, in provisional restorations, and in repair of complete and partial removable dentures.

Composite Resins↗

Long-term resin bond strength to zirconia ceramic.

PURPOSE: The aim of this in vitro study was to evaluate the long-term bond strength of adhesive bonding systems to yttrium-oxide-partially-stabilized zirconia ceramic (YPSZ). MATERIALS AND METHODS: Plexiglas tubes filled with resin composite were bonded to industrially manufactured zirconia ceramic disks (96% ZrO2 stabilized by 4% Y2O3). After air abrading the ceramic and ultrasonic cleansing, groups of 16 samples were bonded in an alignment apparatus using 7 different bonding methods. Subgroups of 8 bonded samples were tested for tensile strength following storage in distilled water at 37 degrees C either for 3 days or 2 years. In addition, the 2-year samples were thermocycled 37,500 times. The statistical analyses were conducted with the Kruskal-Wallis test followed by multiple pair-wise comparison of the groups using the Wilcoxon rank sum test. RESULTS: A moderate to relatively high initial bond strength was achieved by air abrasion alone, the additional use of a silane, or acrylizing the YPSZ surface in combination with a conventional bis-GMA resin composite. However, these methods failed spontaneously over storage time. The use of the bis-GMA resin composite after tribochemical silica coating of YPSZ and the use of a polyacid-modified resin composite after air abrasion of YPSZ resulted in a high initial bond strength which decreased significantly over storage time. A durable resin bond strength to YPSZ was achieved only after air abrasion of YPSZ and using one of two resin composites containing a special phosphate monomer. CONCLUSION: A durable bond strength to YPSZ was achieved only by using resin composites containing a special adhesive monomer.

Acrylates↗

Effect of eccentric load cycling on microleakage of Class V flowable and packable composite resin restorations.

Class V composite restorations are subject to the stresses that induce non-carious cervical lesions. This study evaluated the effect of eccentric oblique load on microleakage of restorations. Class V cavities were randomly prepared on the buccal surfaces of 40 recently extracted premolars and restored with composite resin according to manufacturers' directions. Teeth were randomly assigned to one of four treatment groups with 10 teeth per group: (1) flowable resin (Revolution) without load cycling; (2) packable resin (Prodigy Condensable) without load cycling; (3) flowable resin with load cycling (200,000 cycles) and (4) packable resin with load cycling (200,000 cycles). All teeth were then immersed in 2% methylene blue solution for 24 hours after thermocycling (500 cycles). Dye penetration was measured (scores 0-3). The results indicated that adding load cycling significantly increased microleakage (p < 0.05). No significant differences in microleakage were observed for flowable resin vs packable resin. Gingival margins had significantly more microleakage (p < 0.05) than occlusal margins.

Analysis of Variance↗

[Color differences between a resin cement and try-in paste].

OBJECTIVE: This study was to measure the color coincidence and difference of resin cement and its try-in paste. METHODS: 3 shades of a resin cement and its try-in paste were measured and analyzed by CIE L*a*b* on a reflection spectrophotometer. RESULTS: For shade 200, vulue of delta E* was less 1.4 in comparison between try-in paste and self-cured resin. CONCLUSION: The try-in paste of shade 200 matched the self-cured resin cement very well, but the try-in paste was lighter and more yellow than the light-cured resin cement. The resin cement of shade 100 was darker and more yellow than try-in paste; resin cement of shade 300 was lighter and more yellow than try-in paste.

Color↗

Effect of commercial acrylic resins on dimensional accuracy of the maxillary denture base.

Denture base dimensional changes were found with commercial thermocured acrylic resins. Fifteen stone cast-wax base sets were packed for routine flasking. Clássico, Vipcril, and Meliodent Multicryl acrylic resins were prepared according to manufacturer instructions. After final acrylic resin pressing, the flasks were placed in strain clamps and submitted to polymerization cycles in heat-water following manufacturer instructions. The resin bases were fixed on casts with instant adhesive and the sets laterally sectioned in the corresponding regions to the distal of canines (A), mesial of first molars (B), and posterior palatal zone (C). The gap between the stone cast and resin base was verified with a measuring microscope at five reference positions for each type of cut. The data were submitted to ANOVA and Tukey's test and a significant statistical difference between the commercial acrylic resins was shown. The pattern of distortion verified in the posterior palatal region was confirmed in the C cut with significant statistical differences among the three acrylic resins. However, there were no significant statistical differences in A and B cuts.

Acrylic Resins↗

The effect of glass fiber reinforcement on the residual monomer content of two denture base resins.

OBJECTIVE: The amount of residual monomer is one of the principal factors affecting the properties of acrylic resin denture bases. In recent years, glass fibers have been used to strengthen denture base resins. The purpose of this study was to investigate the effect of glass fiber reinforcement on the amount of residual methyl methacrylate released from two different denture base resins (heat cured and autopolymerized). METHOD AND MATERIALS: Continuous unidirectional and woven preimpregnated glass fiber reinforcements (Stick and Stick Net) were used to reinforce heat-curing and autopolymerizing denture base resins. RESULTS: The release of residual methyl methacrylate from heat-cured and autopolymerized test specimens reinforced with glass fibers was significantly higher than that from unreinforced test specimens. Stick Net glass fiber reinforcement resulted in significantly higher residual monomer release than did Stick glass fiber reinforcement. Test specimens made from heat-cured denture polymethyl methacrylate released less residual methyl methacrylate than did specimens made from autopolymerized polymethyl methacrylate. CONCLUSION: Glass fiber reinforcement increases the residual monomer content of denture base resins. The level of residual monomer ranged from 0.11% to 0.37% in heat-cured resin and from 0.18% to 0.46% in autopolymerized denture base resin.

Acrylic Resins↗

Influence of curing tip distance on resin composite Knoop hardness number, using three different light curing units.

This in vitro study evaluated the influence of curing tip distance on the Knoop Hardness Number (KHN) of a resin composite when using three different light curing units: (1) a halogen light (XL 1500 curing unit-3M), (2) a "softstart-polymerization" (Elipar Trilight curing in an exponential mode-ESPE) and (3) a PAC (Apolo 95E curing unit-DMD). The resin composite, Filtek Z250 (3M), was cured by these curing units at three light-tip distances from the resin composite: 0 mm, 6 mm and 12 mm. The resin composite specimens were flattened to their middle portion and submitted to 18 KHN measurements perspecimen. The results showed that for the Elipar Trilight unit, the hardness of the resin composite decreased as the light tip distance increased. The XL 1500 unit presented a significant decrease in hardness as the depth of cure of the resin composite increased. Apolo 95E caused a decrease in the resin composite hardness values when the depth of cure and light tip distance increased.

Analysis of Variance↗

Spent ion exchange resin-its treatment from the point of view of safe disposal.

Ion exchange process is one of the treatment methods for radioactive waste. The resin becomes no longer useful after number of cycles of usage. At the same time the regenerated resin cannot be considered as non active waste for disposal. Hence it is felt necessary that the regenerated resin is treated in a fashion so as to result in a form which can be considered as inactive material. It is possible to convert this spent resin into multivalent ionic form which are generally non leachable, thus providing the necessary properties for meeting the disposal criteria. Studies were carried out for the exchange of radioactive ions on these resins with ions like Al3+, Sn4+, Pb2+ and Fe3+ etc. The studies included leachability aspects, exchange with other active ions, thermal characteristics, compressive strength of the cement blocks loaded with the resin etc. Our studies indicated that the order of the stability of the resin with respect to properties like leachability, exchange properties etc. follow the trend as follows: Sn4+ > Pb2+ > Al3+ > Fe3+.

Compressive Strength↗

In vitro buffering properties of 3 composite resins.

AIM: A dental composite resin, Ariston pHc, has been described as having a cariostatic effect by buffering acid saliva and preventing decalcification and infiltration of restorations. The buffering effect has been reported due to the release of OH- originated from the alkaline glass embedded in the resin. The release would occur only in the presence of low salivary pH values. The aim of this in vitro investigation was to evaluate pH variations induced by Ariston pHc and 2 other composite resins (P60 and Z100). METHODS: Eighteen samples were prepared for each composite and 5 specimens of each brand were embedded in artificial saliva according to Brugirar and Mazille, at 3 different pH values. A 1(st) group of 5 specimens of each tested resin was immersed in neutral artificial saliva at pH 7.7, a 2(nd) group in acidified artificial saliva at pH 5.45 and a 3(rd) group in alkalised saliva at pH 9.25. Three other samples of each resin were immersed in tubes containing distilled water at pH 7.23 and served as controls. Twelve tubes were filled only with neutral, alkalised and acidified artificial saliva and distilled water at the above mentioned pH values. Measurements of pH modifications were taken after 1, 3, 9, 14, 31 days. RESULTS. Ariston pHc raised the pH of distilled water up to 9.59 after 1 day, and to 8.42 after 31 days. This pH modification shown by Ariston pHc in distilled water, compared to those of the other 2 composites were statistically highly significant, with p<0.001, while the pH variations of saliva containing the 3 resins were negligible, except for acidified saliva with Ariston pHc, where a slight pH enhancement with some statistical significance (p=0.04) was found. However, acidified saliva without any resin embedded was found to shift to neutrality as well. CONCLUSION: These results strongly suggest that none of the 3 tested materials can achieve an effective buffering action in vitro on low salivary pH values. However, the ability of Ariston pHc to raise the pH in distilled water, and to a lesser degree in acidified saliva, suggests that an in vivo buffering effect cannot be excluded.

Buffers↗