Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Porosity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Microporous silicon and biosensor development: structural analysis, electrical characterisation and biocapacity evaluation.

An investigation of the fabrication of microporous silicon (MPS) layers as a material for the development of an electrolyte insulator semiconductor (EIS) capacitance sensor has been performed. The goal was to create a high surface area substrate for the immobilisation of biorecognition elements. Structural analysis of MPS layers as a function of key etch parameters, namely implant type (p or n), implant dose, hydrofluoric acid (HF) etch concentration and current density has been performed using scanning electron microscopy (SEM). It was possible to image porous layers with average pore diameter as low as 4 nm. n-type silicon samples had larger pore networks than p-type samples and reducing the silicon resistivity led to a reduction in the pores per microm2. It was found that increasing the HF etch concentration reduced the average pore diameter and increased the pores per microm2. Increasing the current density at which the etch was performed has the same effect. Understanding the effect of these parameters allows the MPS layer to be tuned to match specifications for optimum biocapacity. Different MPS layers were electrically characterised using capacitance-voltage and capacitance-frequency sweeps, in order to determine the effect of porosity on increases in surface area. The measured capacitance increased with increasing pores per microm2. p-type silicon with a boron implant in the back of the wafer, which had been etched in 25% HF in ethanol at a current density of 75 mA/cm2 yielded the highest capacitance signal per unit area. The effect of porosity and pore size on the biocapacity of the samples was also determined. For avidin immobilisation, with pores sizes above 5 nm, as the porosity increased the biocapacity increased. MPS fabricated in p-type silicon with a front and back implant etched in 25% HF at a current density of 25 mA/cm2 was used for the capacitance detection of synthetic oligonucleotides.

Biosensing Techniques↗

Comprehensive pore structure characterization of silica monoliths with controlled mesopore size and macropore size by nitrogen sorption, mercury porosimetry, transmission electron microscopy and inverse size exclusion chromatography.

The porosity of monolithic silica columns is measured by using different analytical methods. Two sets of monoliths were prepared with a given mesopore diameter of 10 and 25 nm, respectively and with gradated macropore diameters between 1.8 and 7.5 microm. After preparing the two sets of monolithic silica columns with different macro- and mesopores the internal, external and total porosity of these columns are determined by inverse size-exclusion chromatography (ISEC) using polystyrene samples of narrow molecular size distribution and known average molecular weight. The ISEC data from the 4.6 mm analytical monolithic silica columns are used to determine the structural properties of monolithic silica capillaries (100 microm I.D.) prepared as a third set of samples. The ISEC results illustrate a multimodal mesopore structure (mesopores are pores with stagnant zones) of the monoliths. It is found by ISEC that the ratio of the different types of pores is dependent on the change in diameter of the macropores (serve as flow-through pores). The porosity data achieved from the mercury penetration measurement and nitrogen adsorption as well of scanning electron microscopy (SEM) and transmission electron microscopy (TEM) pictures are correlated with the results we calculated from the ISEC measurements. The ISEC results, namely the multimodal pore structure of the monoliths, reported in several publications, are not confirmed analyzing the pore structures of the different silica monoliths using all other analytical methods.

Adsorption↗

The effect of ceramic and porous fillers on the mechanical properties of experimental dental composites.

OBJECTIVES: The purpose of this study was to investigate the effect of ceramic fillers (containing leucite crystals) and their porosity on the mechanical properties of a new experimental dental composite in order to compare with the properties of composites containing conventional glass fillers. METHODS: In this study, experimental composites were prepared by mixing the silane-treated fillers with monomers. Experimental composites were divided into four groups according to their filler type, amount and porosity. The monomers were composed of 70% Bis-GMA and 30% TEGDMA by weight for all groups. Glass and leucite-containing-ceramic were prepared as different filler types. In order to make fillers porous, leucite-containing-ceramic fillers were treated with HF acid. Camphorquinone and DMAEMA were used as photo initiator system. Post-curing was done for all groups before mechanical testing. Degree of Conversion of composites was measured using FTIR spectroscopy. The diametral tensile strength (DTS), flexural strength and flexural modulus were measured and compared among the groups. RESULTS: The results showed that the stronger and more porous filler has a positive effect on flexural strength. Porosity of filler increased flexural strength significantly. No significant difference was found in DTS tests among the groups. Flexural modulus was affected and increased by using ceramic fillers. The type of the filler affected the DC of the composite and DC increased by post-curing. SIGNIFICANCE: Flexural strength is one of the most important properties of restorative dental materials. Higher flexural strength can be achieved by stronger and more porous fillers. Investigation into the effect of filler on dental material properties would be beneficial in the development of restorative dental material.

Aluminum Silicates↗

"Apparent" Young's elastic modulus and radial recovery for some tableted pharmaceutical excipients.

The effects of compact size and of powder particle size on the determination of "apparent" compressive Young's modulus of elasticity, E, were evaluated, for three pharmaceutical excipients (Microcrystalline cellulose, MCC, Calcium hydrogen phosphate dihydrate, CHPD, and pregelatinized starch, PGS) differing in deformational behaviour during compression. One- and two-compact (composite) specimens were employed and the equations of Spriggs [J. Am. Ceram. Soc. 44 (1961) 628] and Phani & Niyogi [J. Mater. Sci. 22 (1987) 257] were employed for prediction of E, at zero and 0.15 porosity (E(0) and E(0.15)). It was found that E(0) and E(0.15) are affected by the particle size, in the case of PGS, but by the compact size and assembly in the case of MCC and CHPD. Reduction in E(0) and E(0.15) values for two-compact assembly corresponded to large and medium compact size only of MCC and CHPD, while specimen assembly was not affecting significantly the experimental data if small compacts of MCC and CHPD or any size compacts of PGS were used. The exponent f of the Phani and Niyogi equation has been considered as parameter of pore structure and particle morphology. It was significantly affected by the compact size of all the excipients, by the two-compact assembly of MCC and CHPD and by the particle size of CHPD and PGS. Absence of significant particle size effect on the parameter f, for the case of MCC is attributed to the elongated particle shape, while the highly significant one for the case of PGS is explained by the extensive elasto-plastic deformation during compression, which is greatly dependent on the grain size. Values of the % radial elastic recovery (%RR), at porosity 0 and 0.15, were determined and correlation of the experimental data was attempted to Young's modulus (E). A simple linear equation is proposed for prediction of Young's modulus, E, from %RR, at least in the porosity range between 0.1 and 0.3 (representative of commercial pharmaceutical tablets), but use of %RR instead to E is applicable only under many limitations.

Calcium Phosphates↗

Particle size distribution and evolution in tablet structure during and after compaction.

The objective of this study was to investigate the effect of the distribution in size of free-flowing particles for the evolution in tablet structure and tablet strength. For sucrose and sodium chloride, three powders of different size distributions were prepared by mixing predetermined quantities of particle size fractions. For paracetamol, three batches with varying particle size distributions were prepared by crystallisation. The powders were formed into tablets. Tablet porosity and tensile strength were determined directly after compaction and after short-term storage at two different relative humidities. Tablets were also formed after admixture of a lubricant (magnesium stearate) and the tablet tensile strength was determined. For the test materials used in this study, the spread in particle size had no influence on the evolution in tablet porosity and tensile strength during compression. However, the spread in particle size had a significant and complex influence on the short-term post-compaction increase in tablet tensile strength. The effect of the spread was related to the instability mechanism and the presence of lubricant. It is concluded that the distribution in size of free-flowing particles is not critical for the tablet porosity but may give significant effects on tablet tensile strength due to a post-compaction reaction.

Acetaminophen↗

Factors affecting the characteristics of rapidly disintegrating tablets in the mouth prepared by the crystalline transition of amorphous sucrose.

The aim of this study is to investigate the factors affecting the characteristics of rapidly disintegrating tablets containing an amorphous ingredient prepared by crystalline transition method (CTM) under various storage conditions. Effect of storage conditions and formulating ratio of amorphous sucrose on the characteristic changes (tensile strength, porosity, and disintegration time) of the rapidly disintegrating tablets was studied. The storage conditions of different temperature and humidity affected the rate of crystalline transition and the increase in the tablet tensile strength. The faster crystalline transition resulted in a faster rate of increase in the tablet tensile strength. Regarding the effect of the formulating ratio of amorphous sucrose, in the case of 20-100%, the tensile strength after storage as a function of the porosity could be plotted on the same curve. For tablets containing 100% amorphous sucrose, the tablets with different porosity changed to almost the same structure due to the crystalline transition. Hence, the higher formulating ratio of amorphous sucrose provided the longer disintegration time in the mouth. Therefore, we concluded that the formulating ratio of 10-20% of the amorphous sucrose in the tablet is suitable for the rapidly disintegrating tablet in the mouth when prepared by CTM.

Crystallization↗

Predictions of tensile strength of binary tablets using linear and power law mixing rules.

There has recently been an increased interest in predicting the tensile strength of binary tablets from the properties of the individual components. In this paper, measurements are reported for tensile strength of tablets compressed from single-component and binary powder mixtures of lactose with microcrystalline cellulose (MCC), and lactose with two types of silicified microcrystalline cellulose (SMCC and SMCC-HD), which are different in compressibility. Measurements show the tensile strength increases with the relative density for single powders, and both with the relative density and the mass fraction of cellulose in the mixtures. It was also observed, for binary mixtures compacted at 50 and 150 MPa, that there was a slight variation in porosity with the mass fraction of celluloses. The predictions of the tensile strength of binary tablets from the characteristics of the single-components was analysed with the extended Ryshkewitch-Duckworth model by assuming both linear and power law mixing rules for the determination of the parameters "tensile strength at zero porosity and bonding capacity constant". As consequence, four models were analysed and compared with measurements using criteria based on the standard deviation from the mean values. Results showed a good prediction using a linear mixing rule combined with the power law. However, as the predictions of these models depend on the powders and the porosity range for the characterization of single-components, none of them can be systematically considered as being the best to predict binary behaviour from data for individual powders.

Cellulose↗

Hibernating bears as a model for preventing disuse osteoporosis.

The hibernating bear is an excellent model for disuse osteoporosis in humans because it is a naturally occurring large animal model. Furthermore, bears and humans have similar lower limb skeletal morphology, and bears walk plantigrade like humans. Black bears (Ursus americanus) may not develop disuse osteoporosis during long periods of disuse (i.e. hibernation) because they maintain osteoblastic bone formation during hibernation. As a consequence, bone volume, mineral content, porosity, and strength are not adversely affected by annual periods of disuse. In fact, cortical bone bending strength has been shown to increase with age in hibernating black bears without a significant change in porosity. Other animals require remobilization periods 2-3 times longer than the immobilization period to recover the bone lost during disuse. Our findings support the hypothesis that black bears, which hibernate for as long as 5-7 months annually, have evolved biological mechanisms to mitigate the adverse effects of disuse on bone porosity and strength.

Aging↗

Transport of radon gas into a tunnel at Yucca Mountain--estimating large-scale fractured tuff hydraulic properties and implications for the operation of the ventilation system.

Radon gas concentrations have been monitored as part of the operation of a tunnel (the Exploratory Studies Facility-ESF) at Yucca Mountain to ensure worker safety. The objective of this study was to examine the potential use of the radon data to estimate large-scale formation properties of fractured tuffs. This objective was examined by developing a numerical model, based upon the characteristics of the ESF and the Topopah Spring welded (TSw) tuff unit, capable of predicting radon concentrations for prescribed ventilation conditions. The model was used to address two specific issues. First, it was used to estimate the permeability and porosity of the fractures in the TSw at the length scale of the ESF and extending tens of meters into the TSw, which surrounds the ESF. Second, the model was used to understand the mechanism leading to radon concentrations exceeding a specified level within the ESF. The mechanism controlling radon concentrations in the ESF is a function of atmospheric barometric fluctuations being propagated down the ESF along with ventilated air flow and the slight suction induced by the ventilation exhaust fans at the South Portal of the ESF. These pressure fluctuations are dampened in the TSw fracture continuum according to its permeability and porosity. Consequently, as the barometric pressure in the ESF drops rapidly, formation gases from the TSw are pulled into the ESF, resulting in an increase in radon concentrations. Model calibration to both radon concentrations measured in the ESF and gas-phase pressure fluctuations in the TSw yielded concurrent estimates of TSw fracture permeability and porosity of 1 x 10(-11) m2 and 0.00034, respectively. The calibrated model was then used as a design tool to predict the effect of adjusting the current ventilation-system operation strategy for reducing the probability of radon gas concentrations exceeding a specified level.

Air Movements↗

Interpretation of injection-withdrawal tracer experiments conducted between two wells in a large single fracture.

Tracer experiments conducted using a flow field established by injecting water into one borehole and withdrawing water from another are often used to establish connections and investigate dispersion in fractured rock. As a result of uncertainty in the uniqueness of existing models used for interpretation, this method has not been widely used to investigate more general transport processes including matrix diffusion or advective solute exchange between mobile and immobile zones of fluid. To explore the utility of the injection-withdrawal method as a general investigative tool and with the intent to resolve the transport processes in a discrete fracture, two tracer experiments were conducted using the injection-withdrawal configuration. The experiments were conducted in a fracture which has a large aperture (>500 microm) and horizontally pervades a dolostone formation. One experiment was conducted in the direction of the hydraulic gradient and the other in the direction opposite to the natural gradient. Two tracers having significantly different values of the free-water diffusion coefficient were used. To interpret the experiments, a hybrid numerical-analytical model was developed which accounts for the arcuate shape of the flow field, advection-dispersion in the fracture, diffusion into the matrix adjacent to the fracture, and the presence of natural flow in the fracture. The model was verified by comparison to a fully analytical solution and to a well-known finite-element model. Interpretation of the tracer experiments showed that when only one tracer, advection-dispersion, and matrix diffusion are considered, non-unique results were obtained. However, by using multiple tracers and by accounting for the presence of natural flow in the fracture, unique interpretations were obtained in which a single value of matrix porosity was estimated from the results of both experiments. The estimate of porosity agrees well with independent measurements of porosity obtained from core samples. This suggests that: (i) the injection-withdrawal method is a viable tool for the investigation of general transport processes provided all relevant experimental conditions are considered and multiple conservative tracers are used; and (ii) for the conditions of the experiments conducted in this study, the dominant mechanism for exchange of solute between the fracture and surrounding medium is matrix diffusion.

Diffusion↗

Evolution of clog formation with time in columns permeated with synthetic landfill leachate.

Laboratory column tests conducted to gain insight regarding the biological and chemical clogging mechanisms in a porous medium are presented. To seed the porous medium with landfill bacteria, a mixture of Keele Valley Landfill and synthetic leachate permeated through the column under anaerobic conditions for the first 9 days of operation. After this, 100% synthetic leachate was used. The synthetic leachate approximated Keele Valley Landfill leachate in chemical composition but contained negligible suspended solids and bacteria compared with real leachate. The removal of volatile fatty acids (VFAs), primarily acetate, in leachate as it passed through the medium was highly correlated with the precipitation of calcium carbonate (CaCO(3(s))) from solution. The columns experienced a decrease in drainable porosity from an initial value of about 0.38 to less than 0.1 after steady state chemical oxygen demand (COD) removal, resulting in a five-order magnitude decrease in hydraulic conductivity. The decrease in drainable porosity prior to steady state COD removal was primarily due to the growth of a biofilm on the medium surface. After steady state COD removal, calcium precipitation was at least equally responsible for the decrease in drainable porosity as biofilm growth. Clog composition analyses showed that CaCO(3(s)) was the dominant clog constituent and that 99% of the carbonate in the clog material was bound to calcium.

Acetates↗

Investigation of gas production and entrapment in granular iron medium.

A method for measuring gas entrapment in granular iron (Fe0) was developed and used to estimate the impact of gas production on porosity loss during the treatment of a high NO3- groundwater (up to approximately 10 mM). Over the 400-d study period the trapped gas in laboratory columns was small, with a maximum measured at 1.3% pore volume. Low levels of dissolved H2(g) were measured (up to 0.07+/-0.02 M). Free moving gas bubbles were not observed. Thus, porosity loss, which was determined by tracer tests to be 25-30%, is not accounted for by residual gas trapped in the iron. The removal of aqueous species (i.e., NO3-, Ca, and carbonate alkalinity) indicates that mineral precipitation contributed more significantly to porosity loss than did the trapped gases. Using the stoichiometric reactions between Fe0 and NO3-, an average corrosion rate of 1.7 mmol kg-1 d-1 was derived for the test granular iron. This rate is 10 times greater than Fe0 oxidation by H2O alone, based on H2 gas production. NO3- ion rather than H2O was the major oxidant in the groundwater in the absence of molecular O2. The N-mass balance [e.g., N2g and NH4+ and NO3-] suggests that abiotic reduction of NO3- dominated at the start of Fe0 treatment, whereas N2 production became more important once the microbial activity began. These laboratory results closely predict N2 gas production in a separated large column experiment that was operated for approximately 2 yr in the field, where a maximum of approximately 600 ml d-1 gas volumes was detected, of which 99.5% (v/v) was N2. We conclude that NO3- suppressed the production of H2(g) by competing with water for Fe0 oxidation, especially at the beginning of water treatment when Fe0 is highly reactive. Depends on the groundwater composition, gas venting may be necessary in maintaining PRB performance in the field.

Adsorption↗

The effect of a biofilm on solute diffusion in fractured porous media.

At sites in fractured rock where contamination has been exposed to the rock matrix for extended periods of time, the amount of contaminant mass residing in the matrix can be considerable. Even though it may be possible to diminish concentrations by the advection of clean water through the fracture features, back diffusion from mass held in the matrix will lead to a continuing source of contamination. In such an event, the development of a biofilm (a thin film of microbial mass) on the wall of the fractures may act to limit or prevent the back diffusion process. The objective of this preliminary study is to explore the influence imparted by the presence of a biofilm on the process of matrix diffusion. The investigation was conducted using radial diffusion cells constructed from rock core in which biofilm growth was stimulated in a central reservoir. Once biofilms were developed, forward diffusion experiments were conducted in which a conservative solute migrated from the central reservoir into the intact rock sample. Diffusion experiments were performed in a total of 11 diffusion cell pairs where biofilm growth was stimulated in one member of the pair and inhibited in the other. The effect of the presence of a biofilm on tracer diffusion was determined by comparison of the diffusion curves produced by each cell pair. A semi-analytical model that accounts for the presence of a biofilm was used to investigate the effect of the biofilm on mass transfer due to changes in the effective porosity, effective diffusion coefficient, and the depth of penetration of the biofilm into the intact rock. The results show that the biofilm acted to plug the rock matrix, rather than forming a discrete layer on the reservoir surface. The reduction in effective porosity due to the biofilm ranged from 6% to 52% with the majority of the samples in the 30% to 50% range. Based on the present results, with more efficient biofilm stimulation, it is reasonable to assume that a more complete plugging of the microcrack porosity might be possible, leaving a much thicker and efficient barrier than could be achieved via a surface biofilm.

Biofilms↗

Xenon NMR measurements of permeability and tortuosity in reservoir rocks.

In this work we present measurements of permeability, effective porosity and tortuosity on a variety of rock samples using NMR/MRI of thermal and laser-polarized gas. Permeability and effective porosity are measured simultaneously using MRI to monitor the inflow of laser-polarized xenon into the rock core. Tortuosity is determined from measurements of the time-dependent diffusion coefficient using thermal xenon in sealed samples. The initial results from a limited number of rocks indicate inverse correlations between tortuosity and both effective porosity and permeability. Further studies to widen the number of types of rocks studied may eventually aid in explaining the poorly understood connection between permeability and tortuosity of rock cores.

Geological Phenomena↗

NMR relaxometry and imaging of water absorbed in biodegradable polymer scaffolds.

Porous substrates made of poly(3-hydroxybutyrate-3-hydroxyvalerate) (PHBHV) were prepared by a particulate leaching method. After removing the salt by extraction in water, proton nuclear magnetic resonance (NMR) relaxometry and imaging were performed on sets of PHBHV substrates immersed in phosphate-buffered solution during 3 months at different time points. Polarized optical microscopy studies were performed on thin sections, 25 and 5 mum, of the PHBHV samples. The results of NMR relaxometry showed two (1)H nuclei populations, well distinguishable on the free induction decay (FID), due to the different decay time constants, a factor of 10(2) apart. Thus, it was possible to separate the two populations, giving separate distributions of T(1) relaxation times. One population could be associated with water protons in the pores and the other to macromolecular protons. The distributions of T(1) and T(2) of the water proton shifted to lower values with increasing immersion time to a constant value after 30 days. The results obtained by NMR imaging showed an initial increase in the apparent porosity, reaching a plateau after 25 days of immersion. This increase is attributed mainly to the absorption of water in the microporosity as supported by the results of the relaxometry measurements and shown by scanning electron microscopy. The average porosity measured by NMR imaging at the plateau, 78+/-3%, is slightly higher than that determined by optical microscopy, 73+/-9%, which may be due to the fact that the latter method did not resolve the microporosity. Overall, the results suggest that at early stages after immersing the scaffolds in the aqueous medium, first 30 days approximately, NMR imaging could underestimate the porosity of the substrate.

Absorption↗

Bone microstructure and elastic tissue properties are reflected in QUS axial transmission measurements.

Accurate clinical interpretation of the sound velocity derived from axial transmission devices requires a detailed understanding of the propagation phenomena involved and of the bone factors that have an impact on measurements. In the low megahertz range, ultrasonic propagation in cortical bone depends on anisotropic elastic tissue properties, porosity and the cortical geometry (e.g., thickness). We investigated 10 human radius samples from a previous biaxial transmission study using a 50-MHz scanning acoustic microscope (SAM) and synchrotron radiation microcomputed tomography. The relationships between low-frequency axial transmission sound speed at 1 and 2 MHz, structural properties (cortical width Ct.Wi, porosity, Haversian canal density and material properties (acoustic impedance, mineral density) on site-matched cross-sections were investigated. Significant linear multivariate regression models (1 MHz: R(2) = 0.84, p < 10(-4), root-mean-square error (RMSE) = 38 m/s, 2 MHz: R(2) = 0.65, p < 10(-4), RMSE = 48 m/s) were found for the combination of Ct.Wi with porosity and impedance. A new model was derived that accounts for the nonlinear dispersion relation with Ct.Wi and predicts axial transmission velocities measured at different ultrasonic frequencies (R(2) = 0.69, p < 10(-4), RMSE = 52 m/s).

Aged↗

Effect of DO concentration on biofilm structure and membrane filterability in submerged membrane bioreactor.

The structures of biofilms deposited on the membrane surface under different dissolved oxygen (DO) conditions were characterized to identify its relation to membrane filterability in membrane bioreactors (MBR). The rate of membrane fouling for the low DO (LDO) reactor was 7.5 times faster than that for the high DO (HDO) reactor. Even though the biofilm deposited on the membrane surface in the HDO was thicker than in the LDO at the operating terminated (TMP reached 30 Kpa), biofilm resistance in both reactors were similar. Exactly, specific cake resistance of the HDO was lower than that of the LDO. Difference in biofilm characteristics as a result of different DO level was main factor affecting biofouling for both MBRs. The number of small particles ranging from 2-5mum in the biofilm as well as in the bulk solution for the LDO was greater than those for the HDO. The small particles in the bulk solution of the LDO more preferentially deposited on the membrane surface than those of HDO did. Hence, the biofilm porosity in the LDO (0.65) was smaller than that in HDO (0.85). The reduced porosity of LDO biofilm resulted in lower filterability than the HDO. The porosity data obtained from analysis of images of biofilm using confocal scanning laser microscopy (CLSM) was verified in terms of specific cake resistance (alpha) by comparing the experimentally measured values with the semi-theoretically computed values.

Biofilms↗

Comparison of titanium and cobalt-chromium removable partial denture clasps.

STATEMENT OF PROBLEM: The use of titanium alloys for removable partial dentures is an increasingly popular application. While the flexibility of titanium would allow for cast clasps to be placed in deeper undercuts than advisable with cobalt-chromium, it is possible that the retentive forces of the titanium clasp might not maintain sufficient retention after repeated flexing of the clasp arm during insertion and removal of the partial denture. PURPOSE: This study assessed the characteristics of cast clasps made of titanium and titanium alloys to determine whether these materials are suitable alternatives for removable partial denture applications. MATERIAL AND METHODS: Removable partial denture clasps at two undercut depths were fabricated from commercially pure titanium, titanium alloy (Ti-6A1-4V), and cobalt-chromium. Loss of retention force was measured as the clasps underwent 3 years of simulated clinical use. The data were subjected to ANOVA and Scheffé's tests to determine differences. Evidence of casting defects and porosity was evaluated by radiographic examination and nonparametric statistics. SEM microscopy was used to observe surface characteristics that were described qualitatively. RESULTS: For the 0.75 mm undercut specimens, there was less loss of retention for clasps made from pure titanium and titanium alloy than for cobalt-chromium clasps. Porosity was more apparent in the pure titanium and titanium alloy clasps than in those made from cobalt-chromium, but the amount of porosity did not correspond to evidence of fractures or permanent deformation. CONCLUSIONS: The long-term retentive resiliency of the pure titanium and titanium alloy clasps suggests that these materials are suitable for removable partial dentures.

Alloys↗