Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyethylene”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Problematic sites of third body embedment in polyethylene for total hip wear acceleration.

A computational model was developed to identify the sites of third body particle embedment in a total hip acetabular component surface that are most problematic in terms of roughening the overpassing regions of the femoral head counterface, leading in turn to most severely accelerated polyethylene wear. The analytical approach used was to calculate loci of acetabular sites that, during the gait cycle, overpass previously documented regions of kinetically most critical femoral head roughening. Instantaneous local contact stress and sliding distance were postulated as factors contributing to the severity of the femoral head scratching/roughening which would be expected, due to otherwise-similar particles embedded along each such acetabular overpass locus. The computational results showed that the location of debris embedment was a potent determinant of the amount of polyethylene wear acceleration expected. The data also showed that the supero-lateral aspect of the acetabular cup is consistently and by far the most problematic area for third body particle embedment.

Acetabulum↗

Modification of polysulfone membranes with polyethylene glycol and lignosulfate: electrical characterization by impedance spectroscopy measurements.

Two sets of composite membranes having an asymmetric sulfonated polysulfone membrane as support layer have been obtained and electrically characterized (membranes SPS-PEG and PA-LIGS). The skin layer of the membrane SPS-PEG contains different percentages of polyethylene glycol in the casting solution (5, 25, 40, and 60 wt%), while lignosulfonate was used for manufacturing PA-LIGS membranes (5, 10, 20, and 40 wt%). Membrane electrical characterization was done by means of impedance spectroscopy (IS) measurements, which were carried out with the membranes in contact with NaCl solutions at different concentrations (10(-3) < or = c(M) < or = 5x10(-2)). Electrical resistance and equivalent capacitance of the different membrane samples were determined from IS plots by using equivalent circuits as models. Results show a clear decrease in the membrane electrical resistance as a result of both polysulfone sulfonation and the increase of the concentration of modifying substances, although a kind of limit concentration was obtained for both polyethylene glycol and lignosulfonate (40 and 20%, respectively). Results also show a decrease of around 90% in electrical resistance due to polysulfone sulfonation, while the value of the dielectric constant (hydrated state) clearly increases.

Electric Impedance↗

Physical characterizations of microemulsion systems using tocopheryl polyethylene glycol 1000 succinate (TPGS) as a surfactant for the oral delivery of protein drugs.

Attempts were to develop microemulsion systems using medium chain triglyceride, deionized water, and TPGS as surfactant for the oral delivery of protein drugs or poorly water-soluble drugs. Phase diagrams were constructed to elucidate the phase behavior of systems composed of Captex 300 and water with D-alpha-tocopheryl polyethylene glycol 1000 succinate (TPGS) as main surfactant, polysorbates (Tween 20, Tween 40, Tween 60 and Tween 80) as adjuvant surfactants, and polyethylene glycols (PEG 400 and PEG 600) and polyols (ethanediol, 1,2-propanediol, 1,3-propanediol, 1,3-butanediol, 1,4-butanediol and glycerin) as cosurfactants. The ratios of TPGS to Tweens, PEGs or polyols (K(m)) were set at 4/1, 2/1, 1/1, 1/2, and 1/4. The phase diagram for H(2)O/Captex 300/TPGS system reveals that when TPGS was used as a sole surfactant, it is not capable of producing isotropic solutions of water and oil over a wide range of the compositions. H(2)O/Captex 300/TPGS/Tweens systems with various K(m), regardless of the adjuvant surfactant used were capable of producing an isotropic phase. The extension of microemulsion phase and the presence and extension of the gel phase were found to be dependent on the surfactant mixture. The phase diagrams of H(2)O/Captex 300/TPGS systems using polyols as cosurfactants demonstrate that the types of polyols have a slight effect on the region of existence of the microemulsions. Comparison between the isotropic regions for the polyols system reveals that as the relative concentration of polyols increase, the isotropic region decrease in size. This decrease is towards the S(mix)-water axis indicating that as the relative concentration of polyols increases the maximum amount of oil solubilized decreases. The gel region decreased in size with the increase of polyols weight ratio. All polyols do not solubilized Captex 300 without using TPGS as surfactant.

Chemical Phenomena↗

Enhanced anticancer efficacy of alpha-tocopheryl succinate by conjugation with polyethylene glycol.

Alpha-tocopheryl polyethylene glycol succinate (TPGS) has been used to enhance the bioavailability of poorly absorbed drugs and as a vehicle for drug delivery systems. In response to recent reports that alpha-tocopheryl succinate (TOS) acts as an anticancer agent, we investigated whether its polyethylene glycol (PEG) conjugate, TPGS, also possesses anticancer activity. TPGS inhibited the growth of human lung carcinoma cells implanted in nude mice, and in an in vitro cell culture, even more potently than TOS. The time-dependent uptake of TPGS into cells did not differ from that of TOS, indicating that the enhanced antitumor efficacy of TPGS was not due to its increased uptake into cells. Compared with TOS, TPGS was more effective at inducing apoptosis and the generation of reactive oxygen species, suggesting that the superior anticancer efficacy of TPGS is associated with its increased ability to induce apoptosis. Our data suggest that further studies assessing the potential usefulness of TPGS in cancer therapeutics are warranted, since its use as a vehicle in the formulation of anticancer drugs may provide an effective way to improve their therapeutic efficacy.

Animals↗

Heat Loss Prevention (HeLP) in the delivery room: A randomized controlled trial of polyethylene occlusive skin wrapping in very preterm infants.

OBJECTIVES: To determine if polyethylene occlusive skin wrapping of very preterm infants prevents heat loss after delivery better than conventional drying and to evaluate if any benefit is sustained after wrap removal. STUDY DESIGN: This was a randomized controlled trial of infants <28 weeks' gestation. The experimental group was wrapped from the neck down. Only the head was dried. Control infants were dried completely. Rectal temperatures were compared on admission to the neonatal intensive care unit immediately after wrap removal and 1 hour later. RESULTS: Of 55 infants randomly assigned (28 wrap, 27 control), 2 died in the delivery room and 53 completed the study. Wrapped infants had a higher mean rectal admission temperature, 36.5 degrees C (SD, 0.8 degrees C), compared with 35.6 degrees C (SD, 1.3 degrees C) in control infants ( P = .002). One hour later, mean rectal temperatures were similar in both groups (36.6 degrees C, SD, 0.7 degrees C vs 36.4 degrees C, SD, 0.9 degrees C, P = .4). Size at birth was an important determinant of heat loss: Mean rectal admission temperature increased by 0.21 degrees C (95% CI, 0.04 to 0.4) with each 100-g increase in birth weight. CONCLUSIONS: Polyethylene occlusive skin wrapping prevents rather than delays heat loss at delivery in very preterm infants.

Apgar Score↗

A case of dissociation of polyethylene from its metal baseplate in a "one piece" compression-moulded AGC tibial component.

The Anatomic Graduated Component (AGC) total knee arthroplasty is a commonly used prosthesis with good long-term results. This longevity is thought to be due to the technique of manufacture of the polyethylene and its "one piece" design reducing backside wear. Despite the perception of the AGC tibial component being a monobloc, we report a case of dissociation of the polyethylene from the baseplate.

Arthroplasty, Replacement, Knee↗

Primary peg placement in evisceration with the spherical porous polyethylene orbital implant.

PURPOSE: To determine the efficacy of primary placement of a motility coupling post (MCP) in evisceration with the porous polyethylene (PP) implant. DESIGN: Retrospective noncomparative, interventional case series. PARTICIPANTS: Twenty patients undergoing evisceration. METHODS: A modified evisceration technique with porous polyethylene implants was performed, in which an MCP was placed primarily during the initial surgery. All patients were observed postoperatively for a minimum of 3 months. MAIN OUTCOME MEASURES: Socket motility, final position of the MCP in the orbit, patient satisfaction. RESULTS: At the last follow-up visit, an acceptable range of motility was attained in all patients. Nineteen patients had a centrally positioned MCP, and all patients were pleased with the cosmetic outcome and the range of motility achieved. Minor complications were noted, including a malpositioned MCP (n = 1) and poor motility in upgaze (n = 8). CONCLUSIONS: Primary peg placement at the time of evisceration with the PP implant is a promising technique with relatively minor complications so far, but properly constructed studies are required prospectively to compare motility with the MCP versus nonpegged implants.

Adolescent↗

Open windrow composting of polymers: an investigation into the operational issues of composting polyethylene (PE).

This paper investigates the operational issues surrounding the open windrow composting of degradable polyethylene sacks. Areas for consideration were the impact of degradable polyethylene sacks on the composting process, the quality of the finished compost product, and how the use of sacks influenced the on-site processing. These factors were investigated through determining the amount of polymer residue and chemical contaminants in the finished compost product and the daily monitoring of windrow temperature profiles. Site and practical handling considerations of accepting an organic waste contained within PE sacks are also discussed. Statistical analysis of the windrow temperature profiles has led to the development of a model that can help to predict the expected trends in the temperature profiles of open compost windrows where the organic waste is kerbside collected using a degradable PE sack.

Biodegradation, Environmental↗

Comparison of single rubber-nylon balloon and double polyethylene balloon valvuloplasty in 94 patients with rheumatic mitral stenosis.

To compare the single rubber-nylon balloon and double polyethylene balloon techniques, 94 patients with rheumatic mitral stenosis underwent percutaneous transseptal balloon mitral valvuloplasty between November 1985 and September 1988. The single balloon technique was used in 73 patients and the double balloon technique was used in 21. The two groups were similar in age, weight, severity of the lesion, and cardiac functional status. The mean mitral valve diastolic gradient decreased from 17.9 +/- 6.5 to 2.9 +/- 3.1 mm Hg (p less than 0.001), 18.5 +/- 6.7 to 5.8 +/- 3.1 mm Hg (p less than 0.001), and 18.1 +/- 5.9 to 3.2 +/- 3.7 mm Hg (p less than 0.001) in the single balloon group, double balloon group, and the entire series, respectively. The final mitral diastolic gradient in the single balloon group was lower than in the double balloon group (p less than 0.05). Complications in the single balloon group were lower than in the double balloon group. Additional advantages of single over double balloon technique were easier maneuverability and higher success rate. The initial and long-term follow-up results confirmed the earlier impressions that percutaneous transseptal balloon mitral valvuloplasty is an effective and safe nonsurgical method of treatment for rheumatic mitral stenosis, and the single rubber-nylon balloon technique is at least as effective as, if not superior to, the double polyethylene balloon technique.

Adolescent↗

[Composite, non-resorbable parietal prosthesis with polyethylene terephtalate-polyurethane (HI-TEX PARP NT): prevention of intraperitoneal adhesions. Experimental study in rabbits].

The authors report an experimental study in the rabbit with a new composite non absorbable mesh in Polyethylene Terephtalate-Polyurethane used for incisional hernia repair in intraperitoneal positioning. This new mesh has one permeable side in polyethylene terephtalate for rapid tissue fixation and another side in polyruethane, hydrophob in order to avoid cell penetration. Eighteen rabbits were operated. A wound was created in aponeurose, muscle and peritoneal abdominal wall. The mesh was placed in intraperitoneal positioning and was taken off at 4, 9 and 13 months for histologic examination and electronic microscopical examination. Tolerance, adhesion, tissular reaction and neoperitoneum formation have been studied. All the meshes were well integrated and without sepsis. In 18% of cases small and monocclusive intraperitoneal adhesions were found. This new composite mesh in intraperitoneal positioning gave good results at medium-term in the rabbit. It's an attractive alternative for incision hernias repair with intraperitoneal mesh.

Abdominal Muscles↗

Beneficial effect of polyethylene glycol in lung preservation: early evaluation by proton nuclear magnetic resonance spectroscopy.

BACKGROUND: Proton nuclear magnetic resonance spectroscopy can be used to measure organic molecules in biological fluids. In this study, proton nuclear magnetic resonance spectroscopy of bronchoalveolar lavage was assessed to detect cellular damage in lung transplants. Also we evaluated a polyethylene glycol solution in lung preservation. METHODS: An isolated perfused and working pig lung was used to assess initial pulmonary function after in situ cold flush and cold storage for 6 hours in three preservation solutions: (1) Euro-Collins solution, (2) University of Wisconsin solution, and (3) low potassium solution with polyethylene glycol (PEG). Pulmonary vascular resistance and partial pressure of arterial oxygen were measured during reperfusion. Bronchoalveolar lavage was studied by proton nuclear magnetic resonance spectroscopy and a histologic study of the lungs was done at the harvest after ischemia and after reperfusion. RESULTS: Partial pressure of arterial oxygen and pulmonary vascular resistance were significantly better in PEG compared with Euro-Collins solution (p = 0.011). Interstitial edema was significantly higher in Euro-Collins solution (2.4 +/- 0.24; p = 0.02) and University of Wisconsin solution (2.7 +/- 0.20; p = 0.0003) than PEG (2 +/- 0.16). Mitochondria scale was better in PEG (8.1 +/- 0.46) than in Euro-Collins solution (6.2 +/- 0.37; p = 0.0001) or University of Wisconsin solution (5.6 +/- 1.36; p = 0.0046). In bronchoalveolar lavage proton nuclear magnetic resonance spectroscopy spectra, lactate, pyruvate, citrate, and acetate were only detected after reperfusion, with a significantly reduced production of acetate in PEG. Pyruvate was reduced at the limit of significance in PEG versus University of Wisconsin solution. CONCLUSIONS: Proton nuclear magnetic resonance spectroscopy seems to be a simple and suitable method for assessment of early injury to the lung transplant. In this experimental study, PEG preserved the lung better than University of Wisconsin solution and Euro-Collins solution in both the proton nuclear magnetic resonance spectroscopy study as well as the physiologic study.

Animals↗

A prospective blinded randomized trial comparing oral sodium phosphate and polyethylene glycol solutions for bowel preparation prior to barium enema.

PURPOSE: A prospective blinded randomized trial to compare oral sodium phosphate (NaP) solution with polyethylene glycol (PEG) preparations as bowel preparation prior to barium enema examination. PATIENTS AND METHODS: One hundred and ten patients consented to take part and each patient was randomly assigned to receive either NaP (Oral Fleet Prep) or PEG (Lyteprep). The barium enemas were reviewed by two radiologists blinded to the type of bowel preparation the patient had received. The colon was divided into six segments and each segment was assessed for the amount of stool and water present, the adequacy of coating, the ability to exclude inflammatory bowel disease and the presence of polyps. A score of 0-3 (failure to good) was assigned per segment on each of these criteria. RESULTS: The average individual score for the NaP group was 89.2. The average individual score for the PEG group was 88.81. No significant difference was found in the quality of bowel cleansing between the two agents. In particular there was no significant difference in the scores for water retention (two-tailed P = 0.748) and the difference for the quality of coating was considered not quite significant (two-tailed P = 0.0818). CONCLUSION: Oral sodium phosphate cleans the colon as well as polyethylene glycol solutions. The use of NaP will result in significant cost savings and improved patient compliance.

Adolescent↗

Polyethylene stent blockage: a porcine model.

BACKGROUND: Endoscopic insertion of biliary stents is a useful treatment for obstructive jaundice resulting from unresectable tumors of the pancreas and biliary tree. The main drawback is the recurrence of jaundice due to clogging. The aim of this study was to establish an experimental model of polyethylene stent clogging in large white pigs. METHODS: A straight polyethylene stent of 5F (group I), 7F (group II) or 10F size (group III) was inserted in the common bile duct. Animals were killed at 2 months, or earlier if physical signs suggesting stent clogging occurred. Chemicophysical analysis of stent deposition combined stereomicroscopy and identification of the contents by means of Fourrier transform infrared spectroscopy. Bacteriologic analyses included identification of aerobic and anaerobic bacteria and measurement of beta-glucuronidase, lecithinase and lipase activities. RESULTS: Physical signs suggesting stent obstruction or death occurred in 8 of 8 animals in group I, 11 of 12 in group II, and 2 of 8 in group III (p < 0.001). The proportion of mucoprotein in the stent contents tended to fall with increasing stent diameter (mean 82%, 58% and 47% for 5F, 7F and 10F, respectively), whereas wheat starch and calcium bilirubinate content increased with increasing stent diameter (9% and 4%, 18% and 10%, and 29% and 23% for 5F, 7 F, and 10F, respectively), although none of these differences were statistically significant. A variety of bacteria were cultured from the stent deposits, including anaerobic strains. Clostridium species were associated with the highest enzyme activities. CONCLUSIONS: In this model the major component of early stent deposits was mucoprotein, and numerous aerobic and anaerobic bacteria were isolated. Formation of calcium bilirubinate was a late phenomenon and poorly related to bacterial enzymatic activities.

Animals↗

Prospective randomized trial comparing Tannenbaum Teflon and standard polyethylene stents in distal malignant biliary stenosis.

BACKGROUND: Our aim was to compare the clinical efficacy of the Tannenbaum (TB) biliary prostheses, a recently designed Teflon stent without side holes, with the Cotton-Huibregtse (CH) polyethylene stent. METHODS: Fifty-seven patients (26 men, mean age 75.5 years) with unresectable malignant tumors and distal biliary stenosis were included (38 pancreatic head cancer, 17 cholangiocarcinoma, 2 ampullary cancer). Patients were prospectively randomized to have a 10F, 7 cm long TB (29 patients) or CH (28 patients) stent inserted endoscopically. Four patients (2 TB and 2 CH) were excluded: 3 because of the failure of stent insertion and 1 because of a protocol violation. The patients were evaluated clinically and, if necessary, with biochemical tests every month until death or until they needed surgery for symptoms of gastric outlet obstruction. When occlusion or dislocation occurred, the stent was replaced with one of the same type. Cumulative stent patency and patient survival were estimated with the Kaplan-Meier life-table analysis and compared by log-rank chi-square test. RESULTS: The two groups were comparable in mean age, gender, and diagnosis. The patients were followed for a mean of 145.5 days (range 24 to 613); by the end of the study 47 patients (81%) had died or developed symptoms of gastric outlet obstruction. Median survival was 88 days (range 24 to 613) in the TB group and 75.6 days (23 to 486) in the CH group. Stent exchange (occlusion 16, dislocation 3) was necessary for 5 patients in the TB group and 7 in the CH group. No statistical difference was found on comparing the mean duration of function of the first, second, and third stents (analysis of variance, p = 0.80). The median duration of stent function was 96 days (range 11 to 613) in the TB group and 75.5 days (range 23 to 323) in the CH group. No significant difference was found in either survival time (p = 0.48) or stent patency (p = 0.12). CONCLUSION: This study found no significant advantage of the Tannenbaum prostheses over the standard polyethylene stent in the palliation for patients with distal malignant biliary stenosis with regard to survival or length of stent patency.

Aged↗

Comparison of a new sulfate-free polyethylene glycol electrolyte lavage solution versus a standard solution for colonoscopy cleansing.

A new sulfate-free polyethylene glycol electrolyte lavage solution (SF-ELS) for colonoscopy was formulated to taste better and have less net water and electrolyte secretion and absorption than a standard polyethylene glycolelectrolyte lavage solution (PEG-ELS). At two centers, 157 patients were prospectively randomized to receive SF-ELS or PEG-ELS to assess adequacy of preparation, patient tolerance, weight changes, and various hematologic and biochemical parameters. Physician assessment of colon cleansing showed no difference between those patients receiving SF-ELS (N = 74) or PEG-ELS (N = 78). Eighty-two percent of all preps were found to be "clinically acceptable." Subjects receiving SF-ELS had significantly less fullness and cramps, while PEG-ELS subjects reported less nausea. There was no difference between groups for vomiting, overall discomfort, or willingness to repeat the preparation received. Eighty percent of all patients would repeat the randomized cleansing methods. There were no clinically significant changes in weight or assessed laboratory parameters, with the exception of potassium where PEG-ELS patients had an mean decrease of 0.22 mEq/liter vs. 0.01 mEq/liter for SF-ELS (p less than or equal to 0.01). Patient taste questionnaires in those patients expressing a preference showed a preference for SF-ELS (76.6%) over PEG-ELS (23.4%) (p less than or equal to 0.001). Thirty-two (22.5%) of total respondents indicated no preference. We conclude that SF-ELS when compared with PEG-ELS is similarly a safe and effective method of colon cleansing for colonoscopy that is well tolerated. Patients prefer the taste of the new solution.

Colonoscopy↗

Palatability of a new solution compared with standard polyethylene glycol solution for gastrointestinal lavage.

The salty unpleasant taste of the standard polyethylene glycol electrolyte lavage solution constitutes a major drawback, which limits patient compliance. Recently, a new low-sodium cleansing solution was described and introduced as a major advance, allegedly providing a distinctly better taste and improving compliance. We compared the taste of both solutions, seeking a possible preference applying a double-blind randomized design. Twenty-eight healthy volunteers tasted one of the two solutions without a direct comparison. Both solutions were found to have a similar palatability and an equal salty taste. A different group of 50 volunteers compared the two solutions. Twenty-one preferred the standard solution, 25 preferred the new solution (not significant), and 4 subjects had no preference. Among the subjects basing their preference on the saltiness of the solutions, 18 estimated the standard solution to taste more salty than the new low sodium solution, while 18 volunteers found the new solution to taste more salty than the standard solution. This study does not confirm a taste preference for the new low-salt polyethylene glycol electrolyte lavage solution as compared with the standard solution for colonic cleansing. The difference in the salt concentrations of the two solutions could not regularly be distinguished by a group of healthy volunteers.

Adult↗

Alterations in pancreatic ductal morphology following polyethylene pancreatic stent therapy.

BACKGROUND: Polyethylene stents placed in the main pancreatic duct induce morphologic alterations that may resemble chronic pancreatitis. METHODS: We reviewed the sequential pancreatograms of stented patients who had long-term follow-up after stent removal. RESULTS: Forty patients (66%) had a normal baseline pancreatogram, whereas 21 (34%) showed changes of chronic pancreatitis. In 49 of 61 patients (80.3%), one or more had new morphologic changes immediately after stent withdrawal graded as mild (69%), moderate (29%), or severe (2%). Changes included ductal irregularity (49%), narrowing (35.5%), and side branch change (15.5%). Sixteen of the 21 patients (76.1%) with an abnormal baseline pancreatogram had worsening of the baseline abnormality or additional changes while stented, whereas 33 of 40 (82.5%) with a normal baseline developed new morphologic changes. Correlation of stent-induced changes with stent size, length, patency at removal, and duration of stenting failed to show an association. Twenty-five patients with stent-induced changes had a follow-up pancreatogram at a mean of 192 days (10 to 740) after stent removal. There was complete resolution of the changes in 64%, partial resolution in 32%, and no improvement in 5%. CONCLUSION: Morphologic changes induced by polyethylene pancreatic duct stents occurred in 80% of patients. More than one third of these changes did not resolve during the follow-up period. Because of concern over stent-induced fibrosis, the use of pancreatic stents should remain largely experimental.

Follow-Up Studies↗

The role of backside polishing, cup angle, and polyethylene thickness on the contact stresses in metal-backed acetabular components.

Mechanical interactions between the polyethylene liner and the metal-backing play an important role in the load transfer and debris-generation mechanisms of an acetabular component. Insert thickness, cup orientation, and insert-shell interface conditions affect the resulting contact stresses at the articulating and backside surfaces of the polyethylene component. The objective of this study was to determine the variation in contact stresses on a hemispherical acetabular component as a function of the friction coefficient of the line-shell interface, the thickness of the insert, and the load application angle. Three-dimensional finite element models of a metal-backed acetabular component with liner thicknesses of 3-12 mm were developed. The insert-shell interface was modeled as either matte or highly polished, and the load angle of the joint reaction force was changed from 36 to 63 degrees with respect to the dome. We found that the contact stresses at the articulating and backside surfaces of the insert were relatively insensitive to changes in the coefficient of friction at the insert-shell interface (resulting in approximately 1-10% variation in contact stress), when compared to the effect of changing the insert's thickness (approximately 80% variation in contact stress) or changing the direction of the joint reaction force (approximately 20% variation in contact stress). The results of this study suggest that polishing the metal at the insert-shell interface does not substantially change the contact stresses at either surface of the component. Of the design variables available for selective modification by either the surgeon or the engineer, insert thickness and shell orientation play a greater role in determining the magnitude of the resulting contact stresses.

Acetabulum↗