Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “INDEXING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Prospective evaluation of the American Urological Association symptom index and peak urinary flow rate for the followup of men with known urethral stricture disease.

PURPOSE: We prospectively evaluated the American Urological Association (AUA) symptom index and maximum urine flow for predicting urethral stricture recurrence in men with a previous diagnosis of urethral stricture disease. MATERIALS AND METHODS: Patients were recruited at our urethral stricture clinic, where all newly diagnosed and previously treated men with urethral stricture present and are treated. The AUA symptom index was completed and uroflowmetry was done. The stricture was calibrated using Jacques catheters. If an 18Fr catheter could not be passed, a retrograde urethrogram was performed. Patients were treated with filiform dilation or direct vision internal urethrotomy. Uroflowmetry was repeated when the catheter was removed 3 days later and the AUA symptom index was repeated 1 month later. RESULTS: Data on 49 patients (170 consultations) between March 2000 and August 2001 were analyzed. Average patient age was 48 years. There was a significant negative correlation of urethral diameter with AUA symptom index and of AUA symptom index with maximum urine flow as well as a significant positive correlation of urethral diameter with maximum urine flow. We evaluated the usefulness of AUA symptom index and maximum urine flow at different cutoff levels for predicting urethral stricture in our study group. Using an AUA symptom index of greater than 10 or maximum urine flow of less than 15 ml. per second as cutoff values provided 93% sensitivity, 68% specificity, 78% positive predictive value, 89% negative predictive value and 82% overall accuracy. This method could have prevented further invasive studies in 34% of patients, while a clinically significant stricture would have been missed in only 4.3%. CONCLUSIONS: AUA symptom index combined with maximum urine flow is an accurate, time-saving and cost-effective tool for predicting recurrent stricture in patients with a known urethral stricture. It can be used to direct decision making on further invasive studies and treatment.

Adult↗

The Amsterdam Pain Management Index compared to eight frequently used outcome measures to evaluate the adequacy of pain treatment in cancer patients with chronic pain.

There is no 'gold standard' to assess the adequacy of pain treatment in cancer patients. The purpose of the study is to explore the Amsterdam Pain Management Index, a newly designed measure to evaluate the adequacy of cancer pain treatment, and to compare it with eight frequently used outcome measures. The Amsterdam Pain Management Index compares patients' Present Pain Intensity, Average Pain Intensity, and Worst Pain Intensity with a composite score of analgesics used, while correcting for what a patient considers as a tolerable level of pain. The eight frequently used outcome measure consisted of three Pain Intensity Markers, the Pain Relief Scale, the Patient Satisfaction Scale, and three Pain Management Indexes. In a randomized controlled trial, 313 cancer patients with a pain duration of at least 1 month were included and followed-up three times until 2 months postdischarge at home. The experimental group received a Pain Education Program, consisting of tailored pain information and instruction. Results showed that, except for the three Pain Management Indexes, the agreement between the measures was very low to moderate. The test of known-groups comparisons and equivalence between groups indicated that the Amsterdam Pain Management Index showed promising results. The Pain Intensity Markers and the Pain Relief Scale were limited in discriminating between groups, while the Patient Satisfaction Scale showed no differences between patient groups. Although it was possible for the Pain Management Indexes to distinguish between patient groups, the differences were not in the expected direction. The ability of the outcome measures to detect changes over time was clearly demonstrated by all outcome measures. Effects of the intervention were only found for the Amsterdam Pain Management Index and patients' Substantial Worst Pain score. Although support was provided for the use of the Amsterdam Pain Management Index, more research is warranted.

Aged↗

Estimation of the ejection fraction in patients with myocardial infarction obtained from the combined index of systolic and diastolic left ventricular function: a new method.

UNLABELLED: The index of myocardial performance combining systolic and diastolic time intervals (Index) is a useful method, already explained in past studies, that offers new values that have not been widely known among clinical cardiologists. The aim of this study is to obtain from this Index a measurement of the ejection fraction (EF), which is a very well-known value. The study involved 97 patients with myocardial infarction, 55 of whom were studied retrospectively (group A, aged 46-62 years, 50 men) to obtain and test the formula EF = 60 - (34 x Index). The second group (group B, aged 47-63 years, 40 men) included 42 patients who were evaluated prospectively. The EF obtained was compared with that reached through the use of radionuclide angiography (EF-RNA). The Index was obtained through the use of the formula (a - b)/b, where a is the interval between cessation and onset of the mitral inflow, and b is the ejection time. In group A the EF obtained by the Index (EF-Index) was 37.5% +/-.8%, and the EF-RNA was 37.7% +/- 11% (r = 0.76). In group B the EF-Index was 41.6% +/- 7%, and the EF-RNA was 41.2% +/- 10% (r = 0. 75). CONCLUSION: Through the new formula described here it is possible to obtain a reliable measurement of the EF in patients with myocardial infarction, a well-known and extremely useful value, especially for those patients with poor acoustic windows.

Adult↗

Small valve area index: its influence on early mortality after mitral valve replacement.

OBJECTIVE: To test the hypothesis that mitral valve prosthesis-patient mismatch increases postoperative mortality. METHODS AND RESULTS: The effect of mitral valve prosthesis-patient mismatch on survival in a cohort of consecutive patients after mitral valve replacement with a mechanical prosthesis was measured, focusing on the lower tail of the normal distribution curve of the prosthetic valve area index. For the calculation of the geometric valve area index (cm(2)/m(2) body surface area), we used specifications for the geometric valve area supplied by the manufacturer. The cut-off value of the 10th percentile of the valve area index was 1.919 cm(2)/m(2). The study population consisted of 428 adult patients who underwent mitral valve replacement by a Medtronic Hall (n=270, 63%) or a St. Jude Medical prosthesis (n=158, 37%). The size of the valves implanted ranged from 25 mm to 31 mm. The valve area index showed a normal distribution curve ranging from 1.43 to 2.98 cm(2)/m(2) with a mean of 2.2 cm(2)/m(2). Group 1 (n=33) had a valve area index <1.9 cm(2)/m(2) and group 2 (n=395), > or =1.9 cm(2)/m(2). The 30-day mortality was higher in group 1 than in group 2 (18.2 vs. 4.1%, P=0.005). Multivariate logistic regression analysis of the determinants of the 30-day mortality rendered a small valve area index (<1.9 cm(2)/m(2)) as an independent risk indicator: relative risk 4.3 (95% CI 1.6-9.5; P=0. 0043). The difference in overall survival between the two groups was entirely due to the high 30-day mortality in the patients with small valve area indices, congestive heart failure being the main cause of death. CONCLUSIONS: By concentrating on the extreme lower tail of the normal distribution of the valve area index, a strong and independent relation was found between relatively small valves (valve area index <1.9 cm(2)/m(2)) and 30-day mortality. We found no influence of valve size on late mortality beyond the first 30 days.

Adult↗

Bispectral index monitoring in patients undergoing cardiac surgery under cardiopulmonary bypass.

BACKGROUND AND OBJECTIVE: Monitoring the depth of anaesthesia by the bispectral index facilitates the titration of anaesthetic drugs during operation as well as assisting in early recovery. We planned to use this index to control the administration of anaesthetic agents in order to stabilize haemodynamics and promote recovery from anaesthesia in patients undergoing cardiac surgery with cardiopulmonary bypass. METHODS: Thirty adult patients undergoing valve replacement or coronary artery grafting under cardiopulmonary bypass were studied in a prospective, randomized, controlled study. Bispectral index monitoring was used in all patients. Patients received isoflurane anaesthesia and boluses of morphine: in the study group, anaesthetic depth was controlled using the bispectral index and clinical variables. In the control group, the bispectral index monitor could not be viewed by the anaesthesiologist. Bispectral index, mean arterial pressure and heart rate were noted every 5 min, and the incidence of hypotension, hypertension, tachycardia and bradycardia also noted. The time to recovery, when patients started obeying commands, was also recorded. RESULTS: Patients in the study group had significantly less hypertension and tachycardia (P < 0.05) than those in the control group. The time to recovery of consciousness was less in the study group than in the control group (n.s., P > 0.05). The bispectral index rose significantly in the control group at the time of institution and termination of cardiopulmonary bypass (P < 0.05). CONCLUSIONS: Anaesthesia controlled by bispectral index monitoring decreases the incidence of haemodynamic disturbances and facilitates titration of anaesthetic agents during cardiopulmonary bypass and thus may assist recovery from anaesthesia.

Adolescent↗

The 'TEI-index' is preload dependent and can be measured by transoesophageal echocardiography during mechanical ventilation.

BACKGROUND AND OBJECTIVE: The Doppler-derived echocardiographic TEI-index, defined as the sum of the left ventricular isovolumic contraction and isovolumic relaxation times divided by ejection time, quantifies combined systolic and diastolic ventricular functions. The index has been proposed to be independent of arterial pressure and heart rate, implying a broad clinical usefulness. However, it is unclear whether the index is preload independent. We assessed whether and to what degree the TEI-index is altered by left ventricular loading conditions, and the feasibility of measurement by transoesophageal echocardiography during anaesthesia and mechanical ventilation. METHODS: We studied 17 anaesthetized mechanically ventilated patients with coronary artery disease during variations in left ventricular preload evoked by head-up and head-down tilt, respectively. RESULTS: A head-down tilt increasing left ventricular end-diastolic area from 18.8 +/- 4 to 23.7 +/- 4 cm2 (P < 0.05) significantly decreased the TEI-index from 0.5 +/- 0.17 to 0.33 +/- 0.15 (P < 0.05). In contrast, the TEI-index remained unchanged with decreased left ventricular preload (14.4 +/- 3.7 cm2) during head-up tilt. CONCLUSIONS: An increase in preload decreases the TEI-index indicating its sensitivity to acute increases in left ventricular preload. The TEI-index can be measured perioperatively by transoesophageal echocardiography.

Analysis of Variance↗

The effect of a remifentanil bolus on the bispectral index of the EEG (BIS) in anaesthetized patients independently from intubation and surgical stimuli.

BACKGROUND AND OBJECTIVE: Remifentanil boluses are used in different clinical situations and the effects on bispectral index monitoring are unclear. We analysed the effect of a remifentanil bolus on the bispectral index of the electroencephalogram (bispectral index) under total intravenous anaesthesia with propofol and remifentanil. METHODS: ASA I-III patients were included in this study. All patients received a 2 microg k g-1 remifentanil bolus in a period free from stimuli. Bispectral index and haemodynamic data were collected from an A-2000XP bispectral index monitor (every second) and an AS/3 Datex monitor (every 5 s). Bispectral index data were analysed using the area under the curve. Mean arterial pressure and heart rate were averaged at each 30-s period and analysed using analysis of variance. RESULTS: A total of 240 bispectral index values were obtained per patient. The area under the curve between 90 and 120 s after the bolus was significantly lower than the basal area under the curve (average of all areas before the bolus, P < 0.05). Mean arterial pressure and heart rate were significantly reduced from 96.4 +/- 19.9 mmHg at the time of the bolus to 74.2 +/- 16.6 mmHg 120 s after, and from 70 +/- 16.4 bpm at the time of the bolus to 61 +/- 13.6 bpm after (P < 0.001), respectively. CONCLUSIONS: There was a significant reduction in the areas under the curve between 90-120 s following the bolus. Heart rate and blood pressure also showed significant reductions. Thus, remifentanil bolus given under total intravenous anaesthesia with propofol and remifentanil decreases bispectral index, an effect independent of intubation and surgical stimuli.

Adult↗

A comparison of the effects on bispectral index of mild vs. moderate hypothermia during cardiopulmonary bypass.

BACKGROUND AND OBJECTIVE: Bispectral Index correlates with depth of hypnosis in adult patients. Bispectral index monitoring has been separately examined and validated during both mild and moderate hypothermic cardiopulmonary bypass. However, the effect on bispectral index of these two differing cardiopulmonary bypass temperature regimes has not previously been compared, particularly with the use of volatile anaesthetic agents. METHODS: Following Institutional Ethics Committee approval and informed consent, 30 patients undergoing coronary artery bypass grafting had additional bispectral index monitoring. Sixteen patients had mild hypothermic bypass (32-34 degrees C), and 14 had moderate hypothermic bypass (28-30 degrees C). Anaesthesia was standardized, and was maintained with enflurane throughout surgery. Scores were recorded at 14 specific event-related time points during surgery. RESULTS: This study has demonstrated that in this adult population, a relationship exists between bispectral index score and temperature throughout the duration of cardiac surgery, which included mild or moderate hypothermic cardiopulmonary bypass. It also demonstrated that patients which were categorized as having received moderately hypothermic cardiopulmonary bypass had lower bispectral index scores than those patients who received mild hypothermic cardiopulmonary bypass, at time points corresponding approximately with median steady-state bypass temperature, pre-re-warming and early re-warming periods. CONCLUSIONS: Moderate hypothermic cardiopulmonary bypass has lower bispectral index scores when compared to mild hypothermic cardiopulmonary bypass, at a steady state of inspired enflurane. This may reflect an actual increase in the depth of hypnosis. However, as this study did not address the physico-chemical changes of the volatile agent or the accuracy of the bispectral index algorithm at lower temperatures, we would not advocate a change in practice based solely on this report.

Aged↗

A novel PI index and its applications to QSPR/QSAR studies.

A novel topological index, PI (Padmakar-Ivan index), is derived in this paper. The index is very simple to calculate and has disseminating power similar to that of the Wiener (W) and the Szeged (Sz) indices. The comprehensive studies show that the proposed PI index correlates highly with W and Sz as well as with physicochemical properties and biological activities of a large number of diversified and complex compounds. The proposed PI index promises to be a useful parameter in the QSPR/QSAR studies. The stability of each model is demonstrated by applying cross-validation test. Furthermore, more favorable comparison with other representative indices such as the Randic index is also made in order to establish the predictive ability of the PI index. The results have shown that in several cases the PI index gave better results.

Alkanes↗

Biochemical markers of fibrosis in patients with chronic hepatitis C: a comparison with prothrombin time, platelet count, and age-platelet index.

As an alternative to liver biopsy, an index of five biochemical markers (alpha2-macroglobulin, apolipoprotein A1, haptoglobin, total bilirubin, gamma-glutamyl-transpeptidase) has been shown to predict the severity of hepatitis C-related fibrosis. The objective of this study was to compare this index with other markers frequently used for this purpose (prothrombin time, platelets, age-platelet index). In 323 hepatitis C-infected patients, the discriminative values of these markers for F2-F4 fibrosis (by the METAVIR classification) were compared. By multiple logistic regression analysis, only the five-marker index (P < 0.0001) and prothrombin time (P = 0.02) were independently predictive of F2-F4 fibrosis. For this outcome, the area under the receiver operating characteristic curve was significantly higher for the five-marker index (0.836 +/- 0.024) than the age-platelet index (P = 0.002), and the platelet count and prothrombin time (P < 0.001), indicating greater diagnostic value. The addition of the latter markers to the five-marker index proved unhelpful for increasing its accuracy. In conclusion, an index of five biochemical markers accurately predicts significant hepatitis C-related fibrosis and is superior to traditional markers.

Adult↗

Cerebrospinal fluid C3 and C4 indexes in immunological disorders of the central nervous system.

OBJECTIVES: Validation of cerebrospinal fluid (CSF) indexes as a measure for intrathecal C3 and C4 production. Examination of their role in differential diagnosis of immunological disorders of the central nervous system (CNS). MATERIAL AND METHODS: Correlative study in controls (low back pain without disk herniation) between the CSF/serum ratio (Q) for albumin, and Q C3 and Q C4. Comparative study of C3 and C4 indexes in patients with CNS dysfunction due to relapsing-remitting (RR) multiple sclerosis (MS), secondary progressive (SP) MS, systemic lupus erythematosus (SLE), and human immunodeficiency virus (HIV) infection. RESULTS: Strong and statistically highly significant correlations between Q albumin and Q C3 (r=0.89, P=0.0001), and Q C4 (r=0.68, P= 0.0001). In MS patients decreased mean values for serum (RR, SP) and CSF (RR) C3, and increased C3 index mean value (RR, SP). In CNS SLE increase of mean C3 and C4 index values. In CNS HIV increase of mean C3 and C4 index values, and CSF C3 and C4 concentrations. Most individual index values were within the reference range. CONCLUSION: CSF index is a valid tool to detect intrathecal C3 or C4 production. C3 or C4 index contributes little to the differential diagnosis of immunological CNS disorders. C3 might play a pathogenic role in various immunological CNS disorders.

AIDS Dementia Complex↗

Cataract surgery and effectiveness. 2. An index approach for the measurement of output and efficiency of cataract surgery at different surgery departments.

PURPOSE: To describe a model for comparing the performance of cataract surgery among ophthalmology departments in terms of economic efficiency. METHODS: An index approach for the measurement of outcome of cataract surgery is modeled. The index approach uses information about activities and difficulties in daily life as well as visual acuity and age. The change in activities and difficulties after surgery is expressed by changes in distances, and an overall index score is calculated as ratios of values to distances. Values to distances are estimated as solutions to linear programming problems. Index scores are calculated for two groups of patients, those with an ocular co-morbidity and those without. Economic efficiency is also estimated by use of an index approach. In the estimation of efficiency we use the calculated index scores of outcome of surgery as a measure of output of the ophthalmology department. Four different departments providing cataract surgery are compared. RESULTS: The studied departments showed differences to a great extent when traditional measures of cataract surgery outcomes were used. These differences changed when the outcomes were compared by use of index scores. When economic efficiency was calculated the difference between the departments was further reduced and only one department was considered inefficient according to the model. CONCLUSION: An index approach was used to study outcomes of cataract surgery and economic efficiency in four departments. This approach takes into account the complexity of cost in relation to feasible outcome. The ranking between the departments described by traditional methods turned out differently using the model.

Cataract Extraction↗

Comparison of the classic Glucksberg criteria and the IBMTR Severity Index for grading acute graft-versus-host disease following HLA-identical sibling stem cell transplantation. International Bone Marrow Transplant Registry.

Acute graft-versus-host disease (AGVHD) severity is usually graded (grades 0-IV) by the pattern of organ involvement using the classic Glucksberg-Seattle criteria (GSC). Recently, the International Bone Marrow Transplant Registry (IBMTR) developed a new Severity Index by regrouping the patterns of organ involvement into five Indexes (0-D) that appeared more predictive of transplant-related mortality (TRM) and transplant failure (TF, relapse or TRM). We studied the predictive value of both grading systems of TRM, TF and GVHD-related mortality (GTRM) in a series of 114 consecutive patients > or = 12 years old allografted from a histocompatible sibling at our institution, 100 of whom were evaluable for AGVHD. The IBMTR Severity Index showed better incremental prediction of TRM (relative risks (RR) of 1, 1.5, 1.4, 2 and 2.5 for Indexes 0, A, B, C and D), TF (RRs of 1, 1.6, 1.6, 2 and 2.3, respectively) and GTRM (RRs of 1, 2.2 and 4.8 for Indexes B, C and D) than the GSC. With the GSC different outcomes for TRM and TF were found only from grade 0 to I-II and 0 to IV or I-III to IV, but not from I-II to III. The GSC also appeared less predictive of GTRM (RRs of 1, 0.4 and 2.9 for grades II, III and IV). In our relatively small patient sample, the new IBMTR Severity Index appeared more predictive of transplant outcome than the GSC, especially between no AGVHD, early Indexes (A-B) and advanced Indexes (C-D).

Adolescent↗

Is the midnight-to-midnight average concentration of pollutants an appropriate exposure index for a daily mortality study?

Midnight-to-midnight average pollutant concentration has been widely used as the exposure index in many epidemiological studies. This index, however, does not take account of the variability of time of death, because it simply takes 24-h average concentration from midnight to midnight, and this is equivalent to assuming that all deaths happened at the end of the day. This assumption is clearly inappropriate in the real situation, and might be a significant information bias in the exposure assessment. In order to take account of the variability of time of death, a new exposure index, the number-of-death-weighted 24-h average, is introduced in this study. This new index is calculated for each subject by taking 24-h average concentration preceding the time of death. In this study, this new index is applied to the suspended particulate matter (SPM) exposure assessment in Japan, and compared with the result obtained from the conventional index, the midnight-to-midnight average. There are quite large differences in the SPM average concentration between these two indices. Moreover, risk ratio calculated by the new index at time lag 0, where the mortality data and the average concentration data on the same day are used, is a lot larger than that obtained by the conventional one. In addition to the difference in its magnitude, time lag structure (from 1-5 days) also shows the different patterns between these two indices. This study suggests that the conventional exposure index, the midnight-to-midnight average, may evaluate the risk of SPM incorrectly, because of its inadequacy of capturing the temporal variability.

Air Pollutants↗

Effect of cilnidipine on left ventricular function in hypertensive patients as assessed by tissue Doppler Tei index.

Tissue Doppler Tei index is pointed to be more effective in the evaluation of global cardiac function than systolic and diastolic measurements alone in various heart diseases. This study was designed to assess the effect of cilnidipine on left ventricular function in hypertensive patients by using this index. A group of 40 hypertensives (mean age 55+/-8 years, range: 35-65) and 16 controls (mean age 52+/-9 years, range: 36-65) were included. Hypertensives were classified into non-left ventricular hypertrophy (NLVH) group (25 patients) and left ventricular hypertrophy (LVH) group (15 patients), and treated with cilnidipine for 2 months. Before and after treatment, the participants were examined by echocardiography. Tissue Doppler Tei index was calculated as diastolic time interval measured from end of late diastole to origin of early diastole (a') minus systolic Sm duration (b') divided by b', that is Tei index = (a'-b')/b'. Thirty-seven hypertensive patients finished the treatment. Tei index was significantly higher in NLVH and LVH groups than in control group, and in LVH group than in NLVH group (0.44+/-0.07 vs 0.28+/-0.06, P < 0.001; 0.51+/-0.13 vs 0.28+/-0.06, P < 0.001; 0.51+/-0.13 vs 0.44+/-0.07, P < 0.05). After treatment, Tei index was significantly decreased (0.40+/-0.11 vs 0.46+/-0.10, P < 0.0001); systolic blood pressure and diastolic blood pressure were also decreased significantly. In conclusion, Tei index is impaired in hypertensives before development of ventricular hypertrophy and impairment is more prominent in hypertrophy. Cilnidipine can improve left ventricular function. Tissue Doppler Tei index is gaining importance in evaluating LV function after drug intervention in hypertensive patients.

Calcium Channel Blockers↗

Quality of life in functional dyspepsia: responsiveness of the Nepean Dyspepsia Index and development of a new 10-item short form.

BACKGROUND: The Nepean Dyspepsia Index is a reliable and valid measure of quality of life in functional dyspepsia, but responsiveness has been little studied. The Nepean Dyspepsia Index originally contained 42 items designed to measure impairment of a subject's ability to engage in relevant aspects of their life because of dyspepsia, and their enjoyment of these aspects; in addition, the individual importance of areas was assessed. It was subsequently shortened to 25 items, yielding five sub-scales. AIM: To test the Nepean Dyspepsia Index's responsiveness and develop a responsive, very short form. METHODS: A randomized, double-blind controlled trial was performed in 589 patients with documented functional dyspepsia. Symptoms and quality of life were measured at baseline, 2 and 4 weeks. Responsiveness of the Nepean Dyspepsia Index quality-of-life section was evaluated by correlation with symptom scores and calculation of standardized changes in scores. Two items from each sub-scale which best represented the area of life (by factor loadings) were selected to create the 10-item short form (SF; short form-Nepean Dyspepsia Index). Internal consistency was assessed by Cronbach's alpha and responsiveness was assessed as above. RESULTS: The Nepean Dyspepsia Index quality-of-life scales demonstrated excellent responsiveness to change in both the active and placebo arms (standardized response means all > 1.0). The Nepean Dyspepsia Index accounted for only 8% of the variance in percentage change in symptoms (by visual analogue scales), indicating that it was evaluating areas of life not covered by symptoms. The 10-item short form had adequate internal consistency (all scales > or = 0.70) and all strongly (and significantly) correlated with the long form sub-scales; it was also highly responsive. CONCLUSION: The Nepean Dyspepsia Index is a responsive disease-specific quality-of-life measure; the 10-item short form can be applied in clinical trials of functional dyspepsia.

Dyspepsia↗

Movement response to skin incision: analgesia vs. bispectral index and 95% spectral edge frequency.

We studied the movement response to skin incision in 68 adult (males/females) ASA I-II patients receiving propofol +/- fentanyl intravenous anaesthesia using the bispectral index and 95% spectral edge frequency monitoring with an A-1050 EEG monitor. Following Ethics Committee approval, patients were randomly assigned to one of the following four treatments: Group P (n = 17): propofol infusion, 1 mg kg-1 min-1 intravenous for 2 min, followed by propofol infusion, 200 micrograms kg-1 min-1, until skin incision; Group PF1 (n = 17): fentanyl bolus, 1 microgram kg-1 intravenous + propofol infusion as in Group P; Group PF2 (n = 17): fentanyl bolus, 2 micrograms kg-1 intravenous + propofol infusion as in Group P; and Group PF3 (n = 17): fentanyl bolus, 3 micrograms kg-1 intravenous + propofol infusion as in Group P. The bispectral index and 95% spectral edge frequency were monitored continuously and recorded prior to induction of anaesthesia (base-line) and at skin incision. Twelve, 10, 4 and 4 patients responded to skin incision in Groups P, PF1, PF2 and PF3, respectively (P and PF1 vs. PF2 or PF3; P = 0.0001, and 0.006). The bispectral index and 95% spectral edge frequency were significantly lower at skin incision compared with the base-line values in all the four treatment groups. However, only bispectral index values were significantly lower in the nonmovement as compared with the movement (M) category (32.6 +/- 8.9 vs. 37.4 +/- 10.3; P = 0.04). Though deeper levels of hypnosis to lower bispectral index and 95% spectral edge frequency values may be effective in preventing the movement response to skin incision, provision of adequate analgesia rather than lower bispectral index and 95% spectral edge frequency (clinical maintenance) values may be more reliable for preventing the response to skin incision as bispectral index and 95% spectral edge frequency measure the hypnotic component of the anaesthetic effect. Lower bispectral index values may be more discriminatory as compared with 95% spectral edge frequency values for preventing the movement response to skin-incision.

Adolescent↗

Predictive validity of the BRASS index in screening patients with post-discharge problems. Blaylock Risk Assessment Screening Score.

RATIONALE: Discharge planning is a nursing intervention that aims to ensure continuity of care; it consists of several steps of which selecting patients in need of it is the first one. The Blaylock Risk Assessment Screening Score (BRASS) index is a risk screening instrument which can be used early after admission to identify those patients in need of discharge planning. AIM: To test the predictive validity of the BRASS index in screening patients with post-discharge problems. DESIGN: Prospective longitudinal design with prediction instrument measured at admission, and outcomes measured at discharge and 7 and 30 days after discharge. OUTCOME MEASURES: length of stay, discharge destination, status after discharge. INSTRUMENTS: BRASS index, Problems after discharge Questionnaire, Nottingham Health Profile, COOP/WONCA charts. RESEARCH METHOD: 503 elderly patients were screened at admission with the BRASS index. Length of stay and discharge destination were measured at discharge in these same patients. Outcomes after discharge were gathered only in patients who were discharged home and with length of stay of more than 3 days (n=226); outcomes were measured by postal questionnaires at day 7 and day 30 after discharge. RESULTS: patients identified by the BRASS index as high risk are frequently not discharged home and have a longer length of stay. The BRASS scores correlate significantly with the outcome scores after discharge: the higher the BRASS score, the higher the difficulty score after discharge on all domains. However, the sensitivity of the BRASS index is rather low. CONCLUSION: This study demonstrates that the BRASS index is a good predictor instrument for indicating patients who are not discharged home, that the BRASS scores correlate significantly with problems experienced after discharge and that it has high specificity to predict patients with problems after discharge. Clinical use, however, is limited due to the low sensitivity. The BRASS index is a promising case-finding instrument for discharge planning, but needs further development.

Aged↗