Measurement of the rotor motion and corresponding hemolysis of a centrifugal blood pump with a magnetic and hydrodynamic hybrid bearing.

This study proposed a centrifugal blood pump with a novel magnetic and hydrodynamic hybrid passive bearing, which consisted of a plain journal bearing for radial stability and a permanent magnetic bearing for axial and tilting stability. We measured the radial motion of the bearing and performed hemolysis tests for the different radial clearance sizes. In the results, it appeared that the radial motion had two modes: the stable center mode, in which the radius of the radial motion rapidly converged to less than 20 microm; and the unstable circle mode, in which the rotor suspension linearly increased with the rotation speed. It also appeared that the pumps with the radial clearance of 80 microm caused more hemolysis than with the smaller clearance sizes in the circle mode. The circle mode was avoidable by the higher rotation or the asymmetric pump structure, but the mechanism of hemolysis in this mode was still unclear.

Animals↗

Hydrodynamic evaluation of kangaroo aortic valve matrices for tissue valve engineering.

We evaluated the hydrodynamic performance of kangaroo aortic valve matrices (KMs) (19, 21, and 23 mm), as potential scaffolds in tissue valve engineering using a pulsatile left heart model at low and high cardiac outputs (COs) and heart rates (HRs) of 60 and 90 beats/min. Data were measured in two samples of each type, pooled in two CO levels (2.1 +/- 0.7 and 4.2 +/- 0.6 L/min; mean +/- standard errors on the mean), and analyzed using analysis of variance with CO level, HR, and valve type as fixed factors and compared to similar porcine matrices (PMs). Transvalvular pressure gradient (DeltaP) was a function of HR (P < 0.001) and CO (P < 0.001) but not of valve type (P = 0.39). DeltaP was consistently lower in KMs but not significantly different from PMs. The effective orifice area and performance index of kangaroo matrices was statistically larger for all sizes at both COs and HRs.

Animals↗

Hydrodynamic function of second generation porcine bioprosthetic heart valves.

The hydrodynamic function and leaflet dynamics of second generation porcine valves prepared with low- or zero-pressure fixation have been studied and compared to first generation porcine bioprostheses, bileaflet, and tilting disc mechanical valves. The Carpentier-Edwards Supra-Annular and Hancock II valves showed lower pressure drops than the Medtronic Intact valve and first generation porcine valves, and comparable overall energy losses to mechanical valves at normal cardiac outputs. Only the zero-pressure fixed Intact valve showed synchronous leaflet opening. Delayed leaflet opening and high opening pressures were found in both low- and high-pressure fixed porcine valves. All porcine bioprostheses showed high open leaflet bending strains. Fixation of valve leaflets with "near zero" pressure fixation and a more physiological neutral geometry is necessary to ensure synchronous leaflet opening at low flows and a reduction in commissural bending strains.

Biomechanical Phenomena↗

A single mismatch in the DNA induces enhanced aggregation of MutS. Hydrodynamic analyses of the protein-DNA complexes.

Changes in the oligomeric status of MutS protein was probed in solution by dynamic light scattering (DLS), and corroborated by sedimentation analyses. In the absence of any nucleotide cofactor, free MutS protein [hydrodynamic radius (Rh) of 10-12 nm] shows a small increment in size (Rh 14 nm) following the addition of homoduplex DNA (121 bp), whereas the same increases to about 18-20 nm with heteroduplex DNA containing a mismatch. MutS forms large aggregates (Rh > 500 nm) with ATP, but not in the presence of a poorly hydrolysable analogue of ATP (ATPgammaS). Addition of either homo- or heteroduplex DNA attenuates the same, due to protein recruitment to DNA. However, the same protein/DNA complexes, at high concentration of ATP (10 mm), manifest an interesting property where the presence of a single mismatch provokes a much larger oligomerization of MutS on DNA (Rh > 500 nm in the presence of MutL) as compared to the normal homoduplex (Rh approximately 100-200 nm) and such mismatch induced MutS aggregation is entirely sustained by the ongoing hydrolysis of ATP in the reaction. We speculate that the surprising property of a single mismatch, in nucleating a massive aggregation of MutS encompassing the bound DNA might play an important role in mismatch repair system.

Adenosine Triphosphatases↗

Much larger transcapillary hydrodynamic conductivity in skeletal muscle and skin of man than previously believed.

The capillary filtration coefficient (CFC) in the human forearm, determined with the 'venous occlusion' method, was found to be about 0.005 ml min-1 100 ml-1 soft tissue mmHg-1 when capillary pressure (Pc) was raised by about 30 mmHg, a finding in accordance with previous literature. With gradually smaller increments of Pc, however, the calculated CFC became gradually larger to reach maximal values of about 0.05 ml min-1 100 ml-1 mmHg-1 at increases in venous pressure that raised Pc by only 1.5-2 mmHg. It is suggested that these high CFC values, obtained at increases of intravascular pressure so low as to ensure minimal interference with the normal circulation, reflect the true prevailing transcapillary hydrodynamic conductivity in the tissue. The low CFC values during high increases in capillary (microvascular) pressure, on the other hand, seem to represent serious underestimations of the true CFC as a result of experimentally induced undesired active smooth muscle constrictor responses and/or passive deterioration of capillary exchange function. The conclusion is therefore reached that CFC in skeletal muscle and skin in man might be about 10 times higher than previously believed.

Adult↗

Wall mechanics of the rat bladder. I. Hydrodynamic studies in the time domain.

The hydrodynamic properties of the rat bladder in the collection phase were examined by slow continuous and very fast stepwise cystometry in nine rats. In vivo, the fast volume steps induced a reproducible detrusor contraction (type A) which remained after spinal anaesthesia and anticholinergic treatment, but ceased post-mortally within 1 h. No significant effect of anticholinergic treatment was found on bladder stiffness. The stiffness and relaxation time of the bladder wall increased markedly at large distension. At small and moderate distension, however, the compliances evaluated from continuous and stepwise cystometry were nearly the same, and a linear elastic model of the bladder was applicable. We consider that the rat bladder will be a useful experimental model in further research on viscoelasticity and instability of the bladder wall.

Animals↗

Wall mechanics of the rat bladder. II. Hydrodynamic studies in the frequency domain.

The hydrodynamic properties of the urinary bladder in rat were examined by means of very small periodic changes in volume at different frequencies. The elastance increased with increasing frequency of volume changes, indicating the presence of viscoelastic elements. When the bladder was only moderately distended the influence of viscosity was minor. We consider that the rat bladder examined by this technique is an ideal experimental model for assessment of in vivo effects of pharmacological agents on bladder wall tonus. For example, cholinergic treatment showed a 100% increase in elastance and atropine inhibited this effect completely within 3 min.

Animals↗

In vitro cell shearing device to investigate the dynamic response of cells in a controlled hydrodynamic environment.

Mechanical stresses and strains play important roles in the normal growth and development of biological tissues, yet the cellular mechanisms of mechanotransduction have not been identified. A variety of in vitro systems for applying mechanical loads to cell populations have been developed to gain insight into these mechanisms. However, limitations in the ability to control precisely relevant aspects of the mechanical stimuli have obscured the physical relationships between mechanical loading and the biochemical signals that mediate the cellular response. We present a novel in vitro cell shearing device based on the principles of a cone and plate viscometer that utilizes microstepper motor technology to control independently the dynamic and steady components of a hydrodynamic shear-stress environment. Physical measurements of the cone velocity demonstrated faithful reproduction of user-defined input wave forms. Computational modeling of the fluid environment for the unsteady startup confirmed small inertial contributions and negligible secondary flows. Finally, we present experimental results demonstrating the onset rate dependence of functional and structural responses of endothelial cell cultures to dynamically applied shear stress. The controlled cell shearing device is a novel tool for elucidating mechanisms by which mechanical forces give rise to the biological signals that modulate cellular morphology and metabolism.

Animals↗

Design and hydrodynamic evaluation of a novel pulsatile bioreactor for biologically active heart valves.

Biologically active heart valves (tissue engineered and recellularized tissue-derived heart valves) have the potential to offer enhanced function when compared to current replacement value therapies since they can possibly remodel, and grow to meet the needs of the patient, and not require chronic medication. However, this technology is still in its infancy and many fundamental questions remain as to how these valves will function in vivo. It has been shown that exposing biologically active tissue constructs to pulsatile pressures and flows during in vitro culture produces enhanced extracellular matrix protein expression and cellularity, although the ideal hydrodynamic conditioning regime is as yet unknown. Moreover, in vitro organ-level studies of living heart valves aimed at studying the remodeling processes require environments that can accurately reproduce in vivo hemodynamics under sterile conditions. To this end, we have developed a system to study the effects of subjecting biologically active heart valves to highly controlled pulsatile pressure and flow waveforms under sterile conditions. The device fits inside a standard incubator and utilizes a computer-controlled closed loop feedback system to provide a high degree of control. The mean pressure, mean flow rate, driving frequency, and shape of the pulsatile pressure waveform can be changed automatically in order to simulate both physiologic and nonphysiologic hemodynamic conditions. Extensive testing and evaluation demonstrated the device's ability to subject a biologically active heart valve to highly controlled pulsatile waveforms that can be modulated during the course of sterile incubation.

Bioprosthesis↗

Hemolytic potential of hydrodynamic cavitation.

The purpose of this study was to determine the hemolytic potentials of discrete bubble cavitation and attached cavitation. To generate controlled cavitation events, a venturigeometry hydrodynamic device, called a Cavitation Susceptibility Meter (CSM), was constructed. A comparison between the hemolytic potential of discrete bubble cavitation and attached cavitation was investigated with a single-pass flow apparatus and a recirculating flow apparatus, both utilizing the CSM. An analytical model, based on spherical bubble dynamics, was developed for predicting the hemolysis caused by discrete bubble cavitation. Experimentally, discrete bubble cavitation did not correlate with a measurable increase in plasma-free hemoglobin (PFHb), as predicted by the analytical model. However, attached cavitation did result in significant PFHb generation. The rate of PFHb generation scaled inversely with the Cavitation number at a constant flow rate, suggesting that the size of the attached cavity was the dominant hemolytic factor.

Animals↗

Hydrodynamic modeling of cerebrospinal fluid motion within the spinal cavity.

The fluid that resides within cranial and spinal cavities, cerebrospinal fluid (CSF), moves in a pulsatile fashion to and from the cranial cavity. This motion can be measured hy magnetic resonance imaging (MRI) and may he of clinical importance in the diagnosis of several brain and spinal cord disorders such as hydrocephalus, Chiari malformation, and syringomyelia. In the present work, a geometric and hydrodynamic characterization of an anatomically relevant spinal canal model is presented. We found that inertial effects dominate the flow field under normal physiological flow rates. Along the length of the spinal canal, hydraulic diameter was found to vary significantly from 5 to 15 mm. The instantaneous Reynolds number at peak flow rate ranged from 150 to 450, and the Womersle number ranged from 5 to 17. Pulsatile flow calculations are presented for an idealized geometric representation of the spinal cavity. A linearized Navier-Stokes model of the pulsatile CSF flow was constructed based on MRI flow rate measurements taken on a healthy volunteer. The numerical model was employed to investigate effects of cross-sectional geometry and spinal cord motion on unsteady velocity, shear stress, and pressure gradientfields. The velocity field was shown to be blunt, due to the inertial character of the flow, with velocity peaks located near the boundaries of the spinal canal rather than at the midpoint between boundaries. The pressure gradient waveform was found to be almost exclusively dependent on the flow waveform and cross-sectional area. Characterization of the CSF dynamics in normal and diseased states may be important in understanding the pathophysiology of CSF related disorders. Flow models coupled with MRI flow measurements mnay become a noninvasive tool to explain the abnormal dynamics of CSF in related brain disorders as well as to determine concentration and local distribution of drugs delivered into the CSF space.

Anatomy, Cross-Sectional↗

Modeling vocal fold motion with a hydrodynamic semicontinuum model.

Vocal fold (VF) motion is a fundamental process in voice production, and is also a challenging problem for numerical computation because the VF dynamics depend on nonlinear coupling of air flow with the response of elastic channels (VF), which undergo opening and closing, and induce internal flow separation. The traditional modeling approach makes use of quasisteady flow approximation or Bernoulli's law which ignores air compressibility, and is known to be invalid during VF opening. A hydrodynamic semicontinuum system for VF motion is presented. The airflow is modeled by a modified quasi-one-dimensional Euler system with coupling to VF velocity. The VF is modeled by a lumped two mass system with a built-in geometric condition on flow separation. The modified Euler system contains the Bernoulli's law as a special case, and is derivable from the two-dimensional compressible Navier-Stokes equations in the inviscid limit. The computational domain contains also solid walls next to VFs (flexible walls). It is shown numerically that several salient features of VFs are captured, especially transients such as the double peaks of the driving subglottal pressures at the opening and the closing stages of VF motion consistent with fully resolved two-dimensional direct simulations, and experimental data. The system is much simpler to compute than a VF model based on two-dimensional Navier-Stokes system.

Computer Simulation↗

Lobster sniffing: antennule design and hydrodynamic filtering of information in an odor plume.

The first step in processing olfactory information, before neural filtering, is the physical capture of odor molecules from the surrounding fluid. Many animals capture odors from turbulent water currents or wind using antennae that bear chemosensory hairs. We used planar laser-induced fluorescence to reveal how lobster olfactory antennules hydrodynamically alter the spatiotemporal patterns of concentration in turbulent odor plumes. As antennules flick, water penetrates their chemosensory hair array during the fast downstroke, carrying fine-scale patterns of concentration into the receptor area. This spatial pattern, blurred by flow along the antennule during the downstroke, is retained during the slower return stroke and is not shed until the next flick.

Animals↗

Hydrodynamic evidence in support of spacer regions in chromatin.

Quasi-elastic light scattering and sedimentation velocity methods were used to study the hydrodynamic properties of purified dimer subunits obtained from partial digestion of chicken erythrocyte chromatin with staphylococcal nuclease. The experimental value of 1.87 +/- 0.08 X 10(-7) gram per second for the friction factor of these dimer subunits in low ionic strength buffer cannot be reasonably interpreted in terms of a contiguous sphere model. Analysis by means of an equivalent dimer method suggests that the spacer region accounts for a maximum of 19 percent of the friction properties of the dimer.

Animals↗

Hydrodynamic effects on microcapillary motility and chemotaxis assays of Methylosinus trichosporium OB3b.

A study of the random motility and chemotaxis of Methylosinus trichosporium OB3b was conducted by using Palleroni-chamber microcapillary assay procedures. Under the growth conditions employed, this methanotroph was observed qualitatively with a microscope to be either slightly motile or essentially nonmotile. However, the cells did not not respond in the microcapillary assays in the manner expected for nonmotile Brownian particles. As a consequence, several hydrodynamic effects on these Palleroni microcapillary assays were uncovered. In the random-motility microcapillary assay, nondiffusive cell accumulations occurred that were strongly dependent upon cell concentration. An apparent minimal random-motility coefficient (mu) for this bacterial cell of 1.0 x 10(-7) cm2/s was estimated from microcapillary assays. A simple alternative spectrophotometric assay, based upon gravitational settling, was developed and shown to be an improvement over the Palleroni microcapillary motility assay for M. trichosporium OB3b in that it yielded a more-accurate threefold-lower random-motility coefficient. In addition, it provided a calculation of the gravitational-settling velocity. In the chemotaxis microcapillary assay, the apparent chemotactic responses were strongest for the highest test-chemical concentrations in the microcapillaries, were correlated with microcapillary fluid density, and were strongly dependent upon the microcapillary volume. A simple method to establish the maximal concentration of a chemical that can be tested and to quantify any contributions of abiotic convection is described. Investigators should be aware of the potential problems due to density-driven convection when using these commonly employed microcapillary assays for studying cells which have low motilities.

Bacteriological Techniques↗

Architecture of a nascent Sphingomonas sp. biofilm under varied hydrodynamic conditions.

The architecture of a Sphingomonas biofilm was studied during early phases of its formation, using strain L138, a gfp-tagged derivative of Sphingomonas sp. strain LB126, as a model organism and flow cells and confocal laser scanning microscopy as experimental tools. Spatial and temporal distribution of cells and exopolymer secretions (EPS) within the biofilm, development of microcolonies under flow conditions representing varied Reynolds numbers, and changes in diffusion length with reference to EPS production were studied by sequential sacrificing of biofilms grown in multichannel flow cells and by time-lapse confocal imaging. The area of biofilm in terms of microscopic images required to ensure representative sampling varied by an order of magnitude when area of cell coverage (2 x 10(5) microm(2)) or microcolony size (1 x 10(6) microm(2)) was the biofilm parameter under investigation. Hence, it is necessary to establish the inherent variability of any biofilm metric one is attempting to quantify. Sphingomonas sp. strain L138 biofilm architecture consisted of microcolonies and extensive water channels. Biomass and EPS distribution were maximal at 8 to 9 mum above the substratum, with a high void fraction near the substratum. Time-lapse confocal imaging and digital image analysis showed that growth of the microcolonies was not uniform: adjacently located colonies registered significant growth or no growth at all. Microcolonies in the biofilm had the ability to move across the attachment surface as a unit, irrespective of fluid flow direction, indicating that movement of microcolonies is an inherent property of the biofilm. Width of water channels decreased as EPS production increased, resulting in increased diffusion distances in the biofilm. Changing hydrodynamic conditions (Reynolds numbers of 0.07, 52, and 87) had no discernible influence on the characteristics of microcolonies (size, shape, or orientation with respect to flow) during the first 24 h of biofilm development. Inherent factors appear to have overriding influence, vis-a-vis environmental factors, on early stages of microcolony development under these laminar flow conditions.

Biofilms↗

Biofilm formation in a hydrodynamic environment by novel fimh variants and ramifications for virulence.

Type 1 fimbriae are surface-located adhesion organelles of Escherichia coli that are directly associated with virulence of the urinary tract. They mediate D-mannose-sensitive binding to different host surfaces by way of the minor fimbrial component FimH. Naturally occurring variants of FimH that bind strongly to terminally exposed monomannose residues have been associated with a pathogenicity-adaptive phenotype that enhances E. coli colonization of extraintestinal locations such as the urinary tract. The FimH adhesin also promotes biofilm formation in a mannose-inhibitable manner on abiotic surfaces under static growth conditions. In this study, we used random mutagenesis combined with a novel selection-enrichment technique to specifically identify mutations in the FimH adhesin that confer on E. coli the ability to form biofilms under hydrodynamic flow (HDF) conditions. We identified three FimH variants from our mutant library that could mediate an HDF biofilm formation phenotype to various degrees. This phenotype was induced by the cumulative effect of multiple changes throughout the receptor-binding region of the protein. Two of the HDF biofilm-forming FimH variants were insensitive to mannose inhibition and represent novel phenotypes not previously identified in naturally occurring isolates. Characterization of our enriched clones revealed some similarities to amino acid alterations that occur in urinary tract infection (UTI) strains. Subsequent screening of a selection of UTI FimH variants demonstrated that they too could promote biofilm formation on abiotic surfaces under HDF conditions. Interestingly, the same correlation was not observed for commensal FimH variants. FimH is a multifaceted protein prone to rapid microevolution. In addition to its previously documented roles in adherence and invasion, we have now demonstrated its function in biofilm formation on abiotic surfaces subjected to HDF conditions. The study indicates that UTI FimH variants possess adaptations that enhance biofilm formation and suggests a novel role for FimH in UTIs associated with medical implants such as catheters.

Adhesins, Bacterial↗

Hydrodynamic properties of hydrocephalus shunts: United Kingdom Shunt Evaluation Laboratory.

BACKGROUND: Although about 80% of properly diagnosed patients with hydrocephalus improve after implantation of any model of shunt, the remaining 20% may develop further complications because of inadequate shunt performance. Therefore, hydrocephalus shunts require careful independent laboratory evaluation. METHOD: Computer supported shunt testing, based on the new International Standard Organisation directives, characterises various aspects of pressure-flow performance of shunts such as variability with time, susceptibility to reflux, siphoning, temperature related behaviour, external pressure, the influence of a strong magnetic field (for example, MRI), presence of pulsation in differential pressure, particles in drained fluid, etc. RESULTS: Seven different models of valves, representing most common constructions, have been tested so far. Most contemporary valves have a hydrodynamic resistance which is too low. This may result in overdrainage both related to posture and during nocturnal cerebral vasogenic waves. A long distal catheter increases the resistance of these valves by 100%-200%. Most shunts are very sensitive to the presence of air bubbles and small particles in drained fluid. Few shunt models offer reasonable resistance to negative outlet pressure, preventing complications related to overdrainage. Valves with an antisiphon device may be blocked by raised subcutaneous pressure. All programmable valves are susceptible to overdrainage in an upright position. CONCLUSION: The behaviour of a valve during such testing is of immediate relevance to the surgeon and may not be adequately described in the manufacturer's product information.

Cerebrospinal Fluid Shunts↗