Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Data Accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Intraoperative compensation for brain shift.

BACKGROUND: Tumor removal, brain swelling, the use of brain retractors, and cerebrospinal-fluid drainage all result in an intraoperative brain deformation that is known as brain shift. Thus, neuronavigation systems relying on preoperative image data have a decreasing accuracy during the surgical procedure. Intraoperative image data represent the correct anatomic situation, so their use may compensate for the effects of brain shift. METHODS: In a series of 16 brain tumor patients, we used intraoperative magnetic resonance (MR) imaging to obtain 3-D data, which were then transferred to the microscope-based neuronavigation system. With the help of bone fiducial markers these images were registered intraoperatively, updating the neuronavigation system. RESULTS: In all patients the updating of the neuronavigation system with the intraoperative MR data was successful. It led to reliable neuronavigation with high accuracy; the mean registration error of the update procedure in all patients was 1.1 mm. The updating procedure added about 15 minutes to the operation time. In all patients the area suggestive of remaining tumor was reached and the additional tumor could be resected, resulting in a complete tumor removal in 14 patients. In the remaining patients extension of the tumor into eloquent brain areas prevented a complete excision. CONCLUSIONS: The update of a neuronavigation system with intraoperative MR images reliably compensates for the effects of brain shift. This method allows completion of tumor removal in some difficult brain tumors.

Adolescent↗

Phantom validation of coregistration of PET and CT for image-guided radiotherapy.

Radiotherapy treatment planning integrating positron emission tomography (PET) and computerized tomography (CT) is rapidly gaining acceptance in the clinical setting. Although hybrid systems are available, often the planning CT is acquired on a dedicated system separate from the PET scanner. A limiting factor to using PET data becomes the accuracy of the CT/PET registration. In this work, we use phantom and patient validation to demonstrate a general method for assessing the accuracy of CT/PET image registration and apply it to two multi-modality image registration programs. An IAEA (International Atomic Energy Association) brain phantom and an anthropomorphic head phantom were used. Internal volumes and externally mounted fiducial markers were filled with CT contrast and 18F-fluorodeoxyglucose (FDG). CT, PET emission, and PET transmission images were acquired and registered using two different image registration algorithms. CT/PET Fusion (GE Medical Systems, Milwaukee, WI) is commercially available and uses a semi-automated initial step followed by manual adjustment. Automatic Mutual Information-based Registration (AMIR), developed at our institution, is fully automated and exhibits no variation between repeated registrations. Registration was performed using distinct phantom structures; assessment of accuracy was determined from registration of the calculated centroids of a set of fiducial markers. By comparing structure-based registration with fiducial-based registration, target registration error (TRE) was computed at each point in a three-dimensional (3D) grid that spans the image volume. Identical methods were also applied to patient data to assess CT/PET registration accuracy. Accuracy was calculated as the mean with standard deviation of the TRE for every point in the 3D grid. Overall TRE values for the IAEA brain phantom are: CT/PET Fusion = 1.71 +/- 0.62 mm, AMIR = 1.13 +/- 0.53 mm; overall TRE values for the anthropomorphic head phantom are: CT/PET Fusion = 1.66 +/- 0.53 mm, AMIR = 1.15 +/- 0.48 mm. Precision (repeatability by a single user) measured for CT/PET Fusion: IAEA phantom = 1.59 +/- 0.67 mm and anthropomorphic head phantom = 1.63 +/- 0.52 mm. (AMIR has exact precision and so no measurements are necessary.) One sample patient demonstrated the following accuracy results: CT/PET Fusion = 3.89 +/- 1.61 mm, AMIR = 2.86 +/- 0.60 mm. Semi-automatic and automatic image registration methods may be used to facilitate incorporation of PET data into radiotherapy treatment planning in relatively rigid anatomic sites, such as head and neck. The overall accuracies in phantom and patient images are < 2 mm and < 4 mm, respectively, using either registration algorithm. Registration accuracy may decrease, however, as distance from the initial registration points (CT/PET fusion) or center of the image (AMIR) increases. Additional information provided by PET may improve dose coverage to active tumor subregions and hence tumor control. This study shows that the accuracy obtained by image registration with these two methods is well suited for image-guided radiotherapy.

Algorithms↗

The accuracy of self-reported regulatory data: the case of coal mine dust.

Coal-mine owners are required to measure miner exposures to respirable dust so that compliance with Federal health regulations can be monitored. This study analyzes the problem of possible underreporting of dust exposures. Using two statistical approaches, data for three mining occupations in 54 large underground coal mines during 1976-1978 are examined for evidence of underreporting. First, regression estimates compare dust concentrations reported by coal-mine owners with those reported by government health inspectors. Then, the statistical distribution of concentrations reported by coal-mine owners are examined for the size and nature of their deviation from log-normality. Both approaches suggest widespread underreporting.

Air Pollutants, Occupational↗

An improved accuracy six-load component pedal dynamometer for cycling.

This paper describes a new six-load component pedal dynamometer designed for study of knee overuse injury in cycling. A unique capability of the dynamometer is the ability to interface with multiple pedal platforms of varying height while maintaining a desired elevation of the foot above the pedal spindle axis. The dynamometer was designed using a concept described in an earlier article by Quinn and Mote (1991, Exp. Mech. 30, 40-48) which measures shear strain across multiple, thin cross-sections. An optimal design technique was used for choosing dimensions of the load measuring cross-sections. A dynamometer was designed and built using the optimal results. Calibration, accuracy results, and sample data are presented. A comparison of accuracy reveals that the new dynamometer is more accurate than previously reported instruments.

Bicycling↗

Simultaneous determination of planar chlorobiphenyls and polychlorinated dibenzo-p-dioxins and -furans in Dutch milk using isotope dilution and gas chromatography-high-resolution mass spectrometry.

A method is described for the simultaneous determination of planar chlorobiphenyls and dioxins in milk using isotope dilution and gas chromatography-high-resolution mass spectrometry (GC-MS). The method is based on gel permeation chromatography, alumina clean-up and carbon chromatography and is highly automated, making a high sample throughput possible. Data on recovery, accuracy and reproducibility of results obtained with quality control samples are presented. Data for both dioxins and planar chlorobiphenyls from the analysis of samples of Dutch milk from several areas in the Netherlands are also presented. Possible interference of the chlorobiphenyls in the determination of the dioxins in the GC-MS method is discussed.

Animals↗

Dipole localization accuracy using grand-average EEG data sets.

OBJECTIVE: Dipole localization of grand-average event related potentials only give a tentative description of the estimated underlying neural sources. This study evaluates the differences in dipole solutions between individual and group-average data sets using a standard realistic head model. METHODS: Auditory evoked potentials were recorded from 14 right-handed healthy subjects using a 64 electrode montage. Inverse dipole solutions were obtained for each individual data set, as well as for all individual responses averaged together (grand-average). Differences in dipole solutions between individual and grand-average responses are reported. Simulations using a two dipole model with 15 different electrode sets are then used to investigate the effects of electrode misplacement and random noise on dipole localization. These effects are compared to those due to grand-averaging. RESULTS: The average differences in dipole locations between the individual and grand-averaged data sets were approximately 1.1 cm (SD=0.7 cm). This difference is larger than typical localization errors due to electrode misplacement and typical noise. CONCLUSIONS: Using a standard realistic head model, it is concluded that dipole solutions based on group-averaged EEG datasets are significantly different than those obtained using subject-specific data.

Adolescent↗

SPASM: a 3D-ASM for segmentation of sparse and arbitrarily oriented cardiac MRI data.

A new technique (SPASM) based on a 3D-ASM is presented for automatic segmentation of cardiac MRI image data sets consisting of multiple planes with arbitrary orientations, and with large undersampled regions. Model landmark positions are updated in a two-stage iterative process. First, landmark positions close to intersections with images are updated. Second, the update information is propagated to the regions without image information, such that new locations for the whole set of the model landmarks are obtained. Feature point detection is performed by a fuzzy inference system, based on fuzzy C-means clustering. Model parameters were optimized on a computer cluster and the computational load distributed by grid computing. SPASM was applied to image data sets with an increasing sparsity (from 2 to 11 slices) comprising images with different orientations and stemming from different MRI acquisition protocols. Segmentation outcomes and calculated volumes were compared to manual segmentation on a dense short-axis data configuration in a 3D manner. For all data configurations, (sub-)pixel accuracy was achieved. Performance differences between data configurations were significantly different (p<0.05) for SA data sets with less than 6 slices, but not clinically relevant (volume differences<4 ml). Comparison to results from other 3D model-based methods showed that SPASM performs comparable to or better than these other methods, but SPASM uses considerably less image data. Sensitivity to initial model placement proved to be limited within a range of position perturbations of approximately 20 mm in all directions.

Algorithms↗

Non-invasive imaging compared with intra-arterial angiography in the diagnosis of symptomatic carotid stenosis: a meta-analysis.

BACKGROUND: Accurate carotid imaging is important for effective secondary stroke prevention. Non-invasive imaging, now widely available, is replacing intra-arterial angiography for carotid stenosis, but the accuracy remains uncertain despite an extensive literature. We systematically reviewed the accuracy of non-invasive imaging compared with intra-arterial angiography for diagnosing carotid stenosis in patients with carotid territory ischaemic symptoms. METHODS: We searched for articles published between 1980 and April 2004; included studies comparing non-invasive imaging with intra-arterial angiography that met Standards for Reporting of Diagnostic Accuracy (STARD) criteria; extracted data to calculate sensitivity and specificity of non-invasive imaging, to test for heterogeneity and to perform sensitivity analyses; and categorised percent stenosis by the North American Symptomatic Carotid Endarterectomy Trial (NASCET) method. RESULTS: In 41 included studies (2541 patients, 4876 arteries), contrast-enhanced MR angiography was more sensitive (0.94, 95% CI 0.88-0.97) and specific (0.93, 95% CI 0.89-0.96) for 70-99% stenosis than Doppler ultrasound, MR angiography, and CT angiography (sensitivities 0.89, 0.88, 0.76; specificities 0.84, 0.84, 0.94, respectively). Data for 50-69% stenoses and combinations of non-invasive tests were sparse and unreliable. There was heterogeneity between studies and evidence of publication bias. INTERPRETATION: Non-invasive tests, used cautiously, could replace intra-arterial carotid angiography for 70-99% stenosis. However, more data are required to determine their accuracy, especially at 50-69% stenoses where the balance of risk and benefit for carotid endarterectomy is particularly narrow, and to explore and overcome heterogeneity. Methodology for evaluating imaging tests should be improved; blinded, prospective studies in clinically relevant patients are essential basic characteristics.

Adult↗

Effects of hippocampal lesions in a food location task in pigeons.

This study investigated the role of the hippocampus in pigeons learning of a food-related choice task. The effects of lesions induced by ibotenic acid were analyzed in two experiments. Experiment 1 investigated the effects of hippocampal damage on postoperative memory retrieval and in reversal learning. Experiment 2 investigated the effects of hippocampal lesions on the acquisition and reversal of learning. In both experiments probe tests were used to assess the behavioral strategies underlying the choice. In Experiment 1 hippocampal lesions impaired the preoperative learned performance in terms of choice latency but not choice accuracy. Experiment 2 data showed that, in postoperative learning sessions, latency as well as choice accuracy were impaired by hippocampal damage. The probe tests, in which a curtain was placed around the chamber, revealed behavioral patterns of a non-mapping strategy. This was true in both experiments and groups (experimental and controls). Immediately after training, during the probe tests of both experiments, in which food cups were omitted, the three groups spent more time in the target quadrant. However, immediately after the reversal condition, neither hippocampal damaged nor control pigeons showed a preference for the target quadrant. This may be interpreted as evidence for a hippocampal role in stimulus location learning involving non-mapping strategies.

Analysis of Variance↗

The value of microarray techniques for quantitative gene profiling in molecular diagnostics.

There has been an explosion of interest in microarray technologies that allow the quantification of whole-genome RNA expression data. The apparent correlation of expression profiles with clinically relevant parameters such as disease outcome has raised expectations with respect to the clinical usefulness of the data generated. Yet the accuracy and biological relevance of these data remain contentious, even in basic research applications. Therefore, numerous issues related to format, quality, validation and interpretation remain to be resolved before microarray profiling can become a diagnostic tool of clinical relevance for routine work.

Gene Expression Profiling↗

Witnessing-condition heterogeneity and witnesses' versus investigators' confidence in the accuracy of witnesses' identification decisions.

Undergraduate participants were tested in 144 pairs, with one member of each pair randomly assigned to a "witness" role and the other to an "investigator" role. Each witness viewed a target person on video under good or poor witnessing conditions and was then interviewed by an investigator, who administered a photo line up and rated his or her confidence in the witness. Witnesses also (separately) rated their own confidence. Investigators discriminated between accurate and inaccurate witnesses, but did so less well than witnesses' own confidence ratings and were biased toward accepting witnesses' decisions. Moreover, investigators' confidence made no unique contribution to the prediction of witnesses' accuracy. Witnesses' confidence and accuracy were affected in the same direction by witnessing conditions, and there was a substantial confidence-accuracy correlation when data were collapsed across witnessing conditions. Confidence can be strongly indicative of accuracy when witnessing conditions vary widely, and witnesses' confidence may be a better indicator than investigators'.

British Columbia↗