Complications associated with pediatric cardiac catheterization.

OBJECTIVES: The aim of this study was to determine the relative risks of pediatric diagnostic, interventional and electrophysiologic catheterizations. BACKGROUND: The role of the pediatric catheterization laboratory has evolved in the last decade as a therapeutic modality, although remaining an important tool for anatomic and hemodynamic diagnosis. METHODS: A study of 4,952 consecutive pediatric catheterization procedures was undertaken. RESULTS: Patient ages ranged from 1 day to 20 years (median 2.9 years). One or more complications occurred in 436 studies (8.8%) and were classified as major in 102 and minor in 458, with vascular complications (n=189; 3.8% of procedures) the most common adverse event. Arrhythmic complications (n=24) were the most common major complication. Death occurred in seven cases (0.14%) as a direct complication of the procedure and was more common in infants (n=5). Independent risk factors for complications included a young patient age and undergoing an interventional procedure. CONCLUSIONS: Complications continue to be associated with pediatric cardiac catheterization. Efforts should be directed to improving equipment for flexibility and size, and finding alternative methods for vascular access. Patient age and interventional studies are risk factors for morbidity and mortality.

Adolescent↗

Chronotropic effects of atropine sulfate and methscopolamine bromide in normal subjects and patients undergoing cardiac catheterization.

The increase in heart rate caused by intravenous injections of atropine sulfate (AS) and methscopolamine bromide (MSB) were compared in 12 healthy volunteers. AS, 200 micrograms, or MSB, 100 micrograms, were injected every 3 min for five doses on successive days. Mean heart rate from the second and fifth injections of MSB was significantly greater than after corresponding injections of atropine. The ratio of equivalent doses of MSB and AS was found to be 1:3. Three subjects with AS and four subjects with MSB exhibited reduced heart rates after the first injection. Excellent correlation of plasma atropine concentrations and heart rate increase were obtained in two volunteers (correlation coefficient, r = 0.84). In the second study, AS, 180 micrograms, and MSB, 60 micrograms, were compared in 20 patients undergoing cardiac catheterization and coronary arteriography. Both drugs produced equivalent increments in heart rate. MSB produced a more predictable dose response than AS. Side effects were similar with both drugs when equivalent doses were used. This study confirms previous investigations that MSB can be titrated by intravenous injections to increase heart rate to desired levels. Absence of central nervous system stimulation by MSB suggests that it may be more appropriate for use in patients with myocardial infarction.

Adolescent↗

The EchoMap System: online integration of intracoronary ultrasound and Doppler images into angiographic images during cardiac catheterization. Influence on radiation exposure and procedure parameters.

The EchoMap system allows online integration of intravascular ultrasound (IVUS) and intracoronary Doppler (ICD) images into angiographic images during catheterization, providing exact localization of the IVUS transducer and the ICD wire tip position. Although this is a major advance, the use of the system could lead to more angiographic documentation sequences and enhanced radiation exposure. We investigated the influence of system use on radiation and procedure parameters. During a 22-month period, 794 patients underwent coronary angiography with simultaneous performance of IVUS and/or ICD. The EchoMap system was applied in 392 patients ("EchoMap group"), the remaining 402 patients formed the "No-EchoMap group." Multivariate regression analysis showed no independent association between the use of EchoMap and fluoroscopy time (14.7 +/- 8.5 minutes in the EchoMap group vs 14.5 +/- 10 minutes in the No-EchoMap group, P = NS) or dose area product (7589 +/- 4916 in the EchoMap group vs 7031 +/- 5434 cGy x cm(2), P = NS). EchoMap use was significantly associated with a moderate increase in contrast media amount (392 +/- 162 in the EchoMap vs 356 +/- 155 mL in the No-EchoMap group, P = 0.001). In conclusion, the use of the EchoMap system had no significant influence on radiation exposure during cardiac catheterization, whereas it was associated with a moderate increase in contrast media amount.

Cardiac Catheterization↗

Noninvasive doppler echocardiographic evaluation of left ventricular filling pressures in patients with cardiomyopathies: a simultaneous Doppler echocardiographic and cardiac catheterization study.

OBJECTIVES: The purpose of this study was to examine the relation of the mitral flow velocity curves to left ventricular filling pressures in patients with two different types of myocardial problems: hypertrophic cardiomyopathy and severe left ventricular systolic dysfunction. BACKGROUND: Previous studies have suggested that assessment of Doppler-derived mitral flow velocity curves can be used to predict left ventricular filling pressures in specific disease entities. However, it is unclear whether information derived from specific mitral flow velocity curves obtained from one disease entity can be valid in other disease states. METHODS: The study group consisted of 42 patients with left ventricular systolic dysfunction (group A) and 55 patients with hypertrophic cardiomyopathy (group B); both groups underwent simultaneous cardiac catheterization and were studied by Doppler echocardiography. High fidelity measures of left atrial and left ventricular pressures were obtained simultaneously with mitral flow velocity curves. RESULTS: There was a significant relation between the Doppler echocardiographic variables and mean left atrial pressure in group A patients. The left atrial pressure was directly related to the E/A ratio (r = 0.49, p = 0.004) and inversely related to the deceleration time (r = 0.73, p < 0.001). The sensitivity and specificity of the deceleration time, < 180 m/s, which indicated a mean left atrial pressure > or = 20 mm Hg, were both 100%. In group B patients, there was no significant relation between mean left atrial pressure and deceleration time. CONCLUSIONS: Doppler echocardiographic mitral flow velocity curves are useful in predicting and estimating left ventricular filling pressures in patients with left ventricular dysfunction. However, because of the complexity of the multiple interrelated factors that determine diastolic filling of the left ventricle, these flow velocity curves cannot be used in patients with other disease entities, such as hypertrophic cardiomyopathy. Future studies of different disease states are necessary to fully understand the role of Doppler echocardiography in the assessment of diastolic filling.

Adult↗

Plasma vasopressin response to contrast medium during cardiac catheterization in infants and children.

Fifteen infants and children (M = 7, F = 8), aged from 0 to 13 years, who underwent cardiac catheterization and cardioangiography under ketamine-diazepam anesthesia were the subjects of this study. The effect of a contrast medium, isolamate sodium (66.8%) on the plasma somolality and vasopressin concentration was studied. The plasma osmolality was significantly elevated after contrast medium administration (289 +/- 3 vs. 303 +/- 8 mosmol.kg(-1)) as well as plasma vasopressin (from 2.1 +/- 0.9 vs. 4.7 +/- 2.0 micro-unit.ml(-1)). It is concluded that the administration of contrast medium for cardioangiography causes elevation of plasma osmolality, which leads to the elevation of plasma vasopressin concentration.

Journal Article↗

Frequency of a positive modified Allen's test in 1,000 consecutive patients undergoing cardiac catheterization.

The modified Allen's test (A.T.) is used to prove the adequacy of the blood supply through the ulnar artery to the hand. The test is considered normal if, after compression of both the ulnar and radial arteries followed by repeated clenching of the fingers to squeeze out the blood, the normal or a slightly more pronounced red color of the palm of the hands returns within < 10 sec after release of only the ulnar artery. It is important to perform the test whenever intravascular access to the radial artery is planned. The objective of this study was to determine the percentage of patients presenting a clearly positive (< 5 sec), a moderately positive (between 5-9 sec), or a negative A.T. (10 sec and more), We performed an A.T. on 1,000 consecutive and different patients undergoing cardiac catheterization, on the right wrist, two times, each time by a different examinator trained in this test. An A.T. was performed on 1,000 patients:640 men, 360 women, mean age 62.3 yr (range 28-90 yr). In our population of patients, the relative percentages of a clearly positive (< 5 sec), moderately positive (between 5-9 sec), or negative modified Allen's test (10 sec and more) is 49%, 24%, and 27%, respectively.

Adult↗

Countercurrent aortography: an alternative to cardiac catheterization in infancy.

Countercurrent aortography via a peripheral artery was used to clarify the aortic arch anatomy in 25 infants in whom cross-sectional and Doppler evaluation was inconclusive. Ages ranged from 3 days to 11 months (median 9 days), and 80% were neonates. The suspected diagnosis was aortic coarctation in 21 infants, interrupted aortic arch in two, recoarctation in one, and vascular ring in one. A countercurrent aortogram provided adequate diagnostic information in 24 infants. A diagnosis of coarctation was confirmed in 15, interruption of the aortic arch in two, and vascular ring in one. In six infants countercurrent aortography excluded the presence of anomalies of the aortic arch. In only one infant, who had an anomalous origin of the right subclavian artery from the descending aorta, did this technique fail to provide adequate information. The only complication observed was transient ischemia of the arm in one patient. Countercurrent aortography is a minimally invasive procedure that can provide adequate angiographic information without the need for cardiac catheterization in patients with inconclusive echocardiographic evaluation. Injection into a right upper limb artery is preferred, because it gives better opacification of the ascending and transverse aortic arch than injection into a left one.

Aorta, Thoracic↗

Cholesterol emboli after cardiac catheterization. Eight cases and a review of the literature.

Cholesterol embolization is a puzzling event that may be increasingly iatrogenic in origin. Diagnosis is difficult and requires a high index of suspicion, an appropriate clinical picture, and usually, confirmation by biopsy. Certain laboratory abnormalities may be helpful; the elevated sedimentation rate and relative eosinophilia found in our patients concurs with other cases reported in the literature. Prognosis is related to the extent of systemic involvement, but renal disease is particularly threatening and gangrene and infection can be lethal. Multiple therapeutic regimens have been generally unsuccessful in altering the course of the disease process. The most significant impact on the disease can be made by its prevention. Cholesterol emboli occur spontaneously, but also after invasive aortic procedures such as diagnostic angiography or cardiovascular surgery. In addition, cardiac catheterization and percutaneous transluminal coronary angioplasty have the potential for arterial trauma and consequent cholesterol embolization. Although the apparent increasing numbers of cholesterol emboli may be a reflection of the increased use of arterial invasive procedures, they are being performed on an older, more severely ill population, with other risk factors for the development of embolic phenomena, i.e., age, smoking history, diabetes mellitus, hypertension, and peripheral vascular disease. Our observed cases and review of the literature do not furnish information concerning the comparative incidences of embolization as related to the suggested etiologies. Careful documentation of the clinical situation preceding the event, the type of procedure, the site of arterial entry, and the duration, difficulty, and extent of the intravascular invasion (i.e., above or below the left subclavian artery) are necessary for this purpose. Such data should help to develop guidelines for patient and procedure selection in order to minimize the possibility of cholesterol embolization.

Aged↗

Effects of supplemental oxygen administration on coronary blood flow in patients undergoing cardiac catheterization.

Patients with heart disease are frequently treated with supplemental oxygen. Although oxygen can exhibit vasoactive properties in many vascular beds, its effects on the coronary circulation have not been fully characterized. To examine whether supplemental oxygen administration affects coronary blood flow (CBF) in a clinical setting, we measured in 18 patients with stable coronary heart disease the effects of breathing 100% oxygen by face mask for 15 min on CBF (via coronary Doppler flow wire), conduit coronary diameter, CBF response to intracoronary infusion of the endothelium-dependent dilator ACh and to the endothelium-independent dilator adenosine, as well as arterial and coronary venous concentrations of the nitric oxide (NO) metabolites nitrotyrosine, NO(2)(-), and NO(3)(-). Relative to breathing room air, breathing of 100% oxygen increased coronary resistance by approximately 40%, decreased CBF by approximately 30%, increased the appearance of nitrotyrosine in coronary venous plasma, and significantly blunted the CBF response to ACh. Oxygen breathing elicited these changes without affecting the diameter of large-conduit coronary arteries, coronary venous concentrations of NO(2)(-) and NO(3)(-), or the coronary vasodilator response to adenosine. Administering supplemental oxygen to patients undergoing cardiac catheterization substantially increases coronary vascular resistance by a mechanism that may involve oxidative quenching of NO within the coronary microcirculation.

Acetylcholine↗

Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizations.

Effective dose is an important quantity in relation to assessment of radiation risk. Organ and effective doses to paediatric patients undergoing diagnostic and therapeutic heart catheterization procedures can be assessed by combining relatively simple measurements, e.g. of dose-area product (DAP), and calculated dose conversion factors (DCF). This also holds for the radiation dose to the hospital staff, e.g. the cardiologist. Monte Carlo (MC) simulation of radiation transport in mathematical anthropomorphic phantoms is used to obtain the DCFs, which strongly depend on beam quality and geometrical parameters. The performance of a dedicated fast MC code (PCXMC) for patient dosimetry is compared with that of a more elaborate general purpose MC code (MCNP). Resulting organ doses sometimes may differ considerably, partly due to phantom differences. While MCNP uses separate male and female mathematical phantoms, PCXMC uses a hermaphrodite. However, both codes yield effective doses that agree rather well, so PCXMC can be used for convenience. The MCNP code is used to calculate the effective dose to the cardiologist exposed to radiation scattered from the patient. Without protective clothing, effective dose per procedure to the cardiologist is at least two orders of magnitude lower than that to the patient. The effectiveness of various types and thickness of protective clothing has been evaluated for one view of one cardiac catheterization. The results of the calculations do not contradict experimental studies from the literature. MC simulation may serve as a useful tool to improve the accuracy of estimating occupational effective dose from personal dose monitors.

Adolescent↗

Clinical evaluation of SyvekPatch in patients undergoing interventional, EPS and diagnostic cardiac catheterization procedures.

BACKGROUND: The SyvekPatch (Marine Polymer Technologies, Danvers, Massachusetts) has received Food and Drug Association market clearance for the rapid control of bleeding from vascular access sites and percutaneous catheters. A clinical evaluation was designed to determine the efficacy and safety of this vascular closure device in 1,000 consecutive patients after routine diagnostic and interventional procedures. METHODS: During a 3-month period, a total of 364 interventional patients (stenting, 55%; PTCA, 30%; EPS, 15%) and 636 diagnostic patients (left heart catheterization, 77%; right/left heart catheterization, 23%) were treated. Catheter sheaths ranged in size from 4 12 French (Fr). Antiplatelet therapy was employed in 35% of the interventional procedures. In approximately 20% of the cases, same-side repuncture occurred within 2 3 days. RESULTS: The use of the SyvekPatch on a total of 1,000 consecutive patients resulted in the rapid control of bleeding with only 1 major complication (0.1%; pseudoaneurysm) and few minor complications (1.3%). The pseudoaneurysm was most likely caused by the aberrant location of the sheath. All minor complications were either small hematomas (< 2.5 cm; rate, 0.75%) or slight oozing from the puncture site (rate, 0.6%). Outcomes measured included clinical effectiveness, ability to maintain the femoral access site for future interventions, major complication rates (access-site related hematoma that required blood transfusion or an extended hospital stay, pseudoaneurysm, arteriovenous fistula, arterial or venous thrombosis, and infection), patient comfort and operational efficiency. CONCLUSION: The strong safety and efficacy profile of the SyvekPatch has made a significant impact in our cardiac catheterization lab. Unlike existing vascular closure devices, the SyvekPatch was used following a diagnostic procedure even when a future interventional procedure was scheduled. The effectiveness of the SyvekPatch was not altered by anticoagulation or antiplatelet therapy. The patients and clinical staff were extremely satisfied with the use of the SyvekPatch .

Acetylglucosamine↗

Cardiac catheterization in infants weighing less than 1,500 grams.

BACKGROUND: The improved survival of very low-birth-weight (<1,500 g) infants justifies more aggressive attempts to treat underlying congenital heart disease than in the past. METHODS: We retrospectively reviewed all catheterizations performed at our institution between January 1, 1990 and June 1, 2004 in infants weighing <1,500 g. We performed a 3:1 case-control study. Comparisons were randomly selected from a group of patients catheterized within 6 months of the cases and weighing 2-3 kg. All catheterization data, angiograms, and hospital charts were reviewed. RESULTS: Eighteen patients weighing <1,500 g underwent catheterization. Fifty-four patients were selected as comparisons. There were no significant differences in the age at catheterization, procedure time, fluoroscopy time, or contrast amount (cc/kg). The lower-birth-weight infants were more likely to be premature (median age 29 vs. 37 weeks, P < 0.001), and to have left-sided obstructive lesions including aortic stenosis or coarctation. The comparison patients were more likely to be postoperative (28% vs. 0%, P = 0.02), and included a higher number with hypoplastic left heart syndrome. There was an increased incidence of interventions performed in the lower-birth-weight infants (83% vs. 41%, P = 0.002). There was a difference in the interventions performed between the two groups: the comparisons had more atrial septal procedures, and the lower-birth-weight infants had more coarctation dilations and aortic valve dilations. There were no significant differences in the acute success rate of the procedures (100% vs. 95%), overall complication rate (56 vs. 57%), incidence of blood transfusions (44 vs. 30%), or major complications (11 vs. 13%) between the lower-birth-weight and comparison groups respectively. There was a trend towards higher survival rate in the comparison group in this small study population, but it did not reach significance (80 vs. 61%, P = 0.13). CONCLUSIONS: Cardiac catheterization in neonates <1,500 g is more likely to include percutaneous intervention, especially on the left side, but is generally successful with a complication rate similar to procedures performed in larger infants. Although these procedures are rare, improved miniaturization of equipment would facilitate safer interventions.