Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMIUM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Kinetics of soluble chromium removal from contaminated water by zerovalent iron media: corrosion inhibition and passive oxide effects.

Permeable reactive barriers containing zerovalent iron are being increasingly employed for in situ remediation of groundwater contaminated with redox active metals and chlorinated organic compounds. This research investigated the effect of chromate concentration on its removal from solution by zerovalent iron. Removal rates of aqueous Cr(VI) by iron wires were measured in batch experiments for initial chromium concentrations ranging from 100 to 10 000 microg/L. Chromate removal was also measured in columns packed with zerovalent iron filings over this same concentration range. Electrochemical measurements were made to determine the free corrosion potential and corrosion rate of the iron reactants. In both the batch and column reactors, absolute rates of chromium removal declined with increasing chromate concentration. Corrosion current measurements indicated that the rate of iron corrosion decreased with increasing Cr(VI) concentrations between 0 and 5000 microg/L. At a Cr(VI) concentration of 10 000 microg/L, Tafel polarization diagrams showed that chromium removal was affected by its diffusion rate through a passivating oxide film and by the ability of iron to release Fe2+ at anodic sites. In contrast, water reduction was not mass transfer limited, but chromium did decrease the exchange current for the hydrogen evolution reaction. Even at the most passivating concentration of 10 000 microng/L, effluent Cr(VI) concentrations in the column reactors reached a steady state, indicating that passivation had also reached a steady state. Although chromate contributes to iron surface passivation, the removal rates are still sufficiently fast for in situ iron barriers to be effective for Cr(VI) removal at most environmentally relevant concentrations.

Carcinogens↗

Green route for the utilization of chrome shavings (chromium-containing solid waste) in tanning industry.

Chromium-containing wastes from various industrial sectors are under critical review. Leather processing is one such industrial activity that generates chromium-bearing wastes in different forms. One of them is chrome shavings, and this contributes to an extent of 10% of the quantum of raw skins/hides processed, amounting to 0.8 million ton globally. In this study, the high protein content of chrome shavings has been utilized for reduction of chromium(VI) in the preparation of chrome tanning agent. This approach has been exploited for the development of two products: one with chrome shavings alone as reducing agent and the other with equal proportion of chrome shavings and molasses. The developed products exhibit more masking due to the formation of intermediate organic oligopeptides. This has been corroborated through the spectral, hydrolysis, and species-wise distribution studies. The formation of these organic masking agents helps in chrome tanning by shifting the precipitation point of chromium to relatively higher pH levels. Hence, the developed products find use as chrome tanning agents for leather processing, thus providing a means for better utilization of chrome shaving wastes.

Carcinogens, Environmental↗

Chromium(VI) removal through facilitated transport using CYANEX 923 as carrier and reducing stripping with hydrazine sulfate.

The transport of chromium(VI) through a flat-sheet supported liquid membrane (FSSLM) containing CYANEX 923 (mixture of phosphine oxides) as a carrier has been studied. The permeation of the metal is investigated as a function of various experimental variables: hydrodynamic conditions, concentration of chromium(VI) and HCI in the feed phase, CYANEX 923 concentration and diluent in the membrane, and strippant concentration in the receiving phase. By using hydrazine sulfate in the receiving phase, chromium(VI) is immediately reduced to the less toxic chromium(III). The aqueous mass transfer coefficient and the thickness of the aqueous boundary layer were calculated from the experimental results. The selectivity of CYANEX 923-based FSSLM toward different metal ions and the behavior of the system against other carriers is presented.

Carcinogens↗

Removal of hexavalent chromium with a lignocellulosic substrate extracted from wheat bran.

In this paper, a new recovery system of the toxic hexavalent chromium Cr(VI) is proposed that uses a lignocellulosic substrate derived from the industrial treatment process of wheat bran. We studied the adsorption mechanism of Cr(VI) onto the lignocellulosic substrate and showed that the adsorption reaction consumes a large amount of protons goes along the reduction of Cr(VI) into Cr(III). The oxidation of lignin moieties takes place concurrently to the chromium reduction and leads to the formation of hydroxyl and carboxyl functions. The latter contribute to an increase in the number of ion-exchange sites for the reduced chromium. The maximum adsorption capacity for hexavalent chromium was found at about 35 mg g(-1) in an acidic medium. This is comparable to other natural substrates and ordinary adsorbents.

Adsorption↗

Elevated airborne exposures of teenagers to manganese, chromium, and iron from steel dust and New York City's subway system.

There is increasing interest in potential health effects of airborne exposures to hazardous air pollutants at relatively low levels. This study focuses on sources, levels, and exposure pathways of manganese, chromium, and iron among inner-city high school students in New York City (NYC) and the contribution of subways. Samples of fine particulate matter (PM2.5) were collected during winter and summer over 48 h periods in a variety of settings including inside homes, outdoors, and personal samples (i.e., sampling packs carried by subjects). PM2.5 samples were also collected in the NYC subway system. For NYC, personal samples had significantly higher concentrations of iron, manganese, and chromium than did home indoor and ambient samples. The ratios and strong correlations between pairs of elements suggested steel dust as the source of these metals for a large subset of the personal samples. Time-activity data suggested NYC subways as a likely source of these elevated personal metals. In duplicate PM2.5 samples that integrated 8 h of underground subway exposure, iron, manganese, and chromium levels (>2 orders of magnitude above ambient levels) and their ratios were consistent with the elevated personal exposures. Steel dust in the NYC subway system was the dominant source of airborne exposures to iron, manganese, and chromium for many young people enrolled in this study, with the same results expected for other NYC subway riders who do not have occupational exposures to these metals. However, there are currently no known health effects at the exposure levels observed in this study.

Adolescent↗

Chromium-removal processes during groundwater remediation by a zerovalent iron permeable reactive barrier.

Solid-phase associations of chromium were examined in core materials collected from a full-scale, zerovalent iron permeable reactive barrier (PRB) at the U.S. Coast Guard Support Center located near Elizabeth City, NC. The PRB was installed in 1996 to treat groundwater contaminated with hexavalent chromium. After eight years of operation, the PRB remains effective at reducing concentrations of Cr from average values >1500 microg L(-1) in groundwater hydraulically upgradient of the PRB to values <1 microg L(-1) in groundwater within and hydraulically downgradient of the PRB. Chromium removal from groundwater occurs at the leading edge of the PRB and also within the aquifer immediately upgradient of the PRB. These regions also witness the greatest amount of secondary mineral formation due to steep geochemical gradients that result from the corrosion of zerovalent iron. X-ray absorption near-edge structure (XANES) spectroscopy indicated that chromium is predominantly in the trivalent oxidation state, confirming that reductive processes are responsible for Cr sequestration. XANES spectra and microscopy results suggest that Cr is, in part, associated with iron sulfide grains formed as a consequence of microbially mediated sulfate reduction in and around the PRB. Results of this study provide evidence that secondary iron-bearing mineral products may enhance the capacity of zerovalent iron systems to remediate Cr in groundwater, either through redox reactions at the mineral-water interface or by the release of Fe(II) to solution via mineral dissolution and/or metal corrosion.

Absorption↗

Direct oxidation of guanine and 7,8-dihydro-8-oxoguanine in DNA by a high-valent chromium complex: a possible mechanism for chromate genotoxicity.

Intracellular reductive activation of the human carcinogen chromate, Cr(VI), is a necessary step in the formation of DNA lesions that lead to cancer. Reductive activation forms the transient metastable high-valent oxidation state of Cr(V) as a precursor to the final intracellularly stable oxidation state, Cr(III). In this study, we have used a model high-valent Cr(V) complex, N,N'-ethylenebis(salicylideneanimato)oxochromium(V), Cr(V)-Salen, to probe the mechanism of interaction between this oxidation state of chromium and DNA. This interaction was found to be specific toward the oxidation of the nucleic acid base guanine in unmodified single- and double-stranded oligonucleotides as measured by an increased level of DNA strand cleavage at these sites following piperidine treatment. Replacement of a single guanine residue in DNA with a more readily oxidized 7,8-dihydro-8-oxoguanine (8-oxo-G) base allowed for site-specific oxidation at this modified site within the DNA strand by the Cr(V)-Salen complex. HPLC and ESI-mass spectrometry were used to identify the modified guanine base lesions formed in the reaction of this high-valent chromium complex with the 8-oxo-G-containing DNA substrate. Two of these modified base lesions, identified as guanidinohydantoin and spiroiminodihydantoin, were found in the reaction of the Cr(V)-Salen complex with 8-oxo-G-modified DNA, while only one, spiroiminodihydantoin, was formed from oxidation of the 8-oxo-G nucleoside. A primer extension assay using the exo(-) Klenow fragment demonstrated polymerase arrest at the site of these base modifications as well as a high degree of misincorporation of adenine opposite the site of modification. These results suggest that mutations arising from G --> T transversions would predominate with these lesions. The mechanism of damage and base oxidation products for the interaction between high-valent chromium and DNA described herein may be relevant to the in vivo formation of DNA damage leading to cancer in chromate-exposed human populations. These results also suggest how high-valent chromium can act as a cocarcinogen with 8-oxo-G-forming xenobiotics.

Carcinogens, Environmental↗

Chromium oxidation state imaging in mammalian cells exposed in vitro to soluble or particulate chromate compounds.

Hexavalent chromium compounds are known carcinogens for the respiratory tract in humans. The mechanism of cell transformation by hexavalent chromium compounds is not fully understood although a role for intracellular reduction is sought. The aim of this study was to determine the distribution of Cr valence states in human cells after in vitro exposure to soluble or particulate chromium compounds. A synchrotron X-ray-based microprobe was used to investigate the cellular reduction of Cr(VI) and to image chromium oxidation states in cells. It was shown that soluble Cr(VI) compounds are fully reduced to Cr(III) in cells. Cr(III) is homogeneously distributed within the cell volume and therefore present within the nucleus. In the case of low solubility particulate chromate compounds, Cr(VI) can coexist in the cell environment, as particles in the perinuclear region, together with intracellular and intranuclear Cr(III). Chemical distribution maps also suggest that intracellular Cr(III) originates from extracellular dissolution and reduction of lead chromate rather than from intracellular engulfed particles. The possible stronger carcinogenicity of low solubility chromate vs soluble chromate compounds may derive from the combinative genotoxic effects of intranuclear Cr(III) and the persistent exposure to a strong oxidant, Cr(VI).

Animals↗

Cytotoxic and clastogenic effects of soluble and insoluble compounds containing hexavalent and trivalent chromium.

Cr(III) and Cr(VI) compounds of varying solubilities have been tested in vitro for their ability to inhibit cell growth and nucleic acid and protein syntheses in BHK cells, to induce alterations in the mitotic cycle in HEp cells, and to increase the frequency of chromosomal aberrations and sister chromatid exchanges (SCE) in CHO cells. All Cr(VI) compounds, and particularly those containing soluble Cr(VI), such as potassium dichromate and zinc yellow, differentially inhibit macromolecular syntheses in BKH cells, that of DNA being always the most affected. Among Cr(III) compounds, which generally have very low cytotoxicity, chromite is particularly active, and inhibits cell growth and DNA synthesis even more than the poorly soluble Cr(VI) compounds. Preincubation in growth medium, with or without metabolizing cell cultures, solubilizes considerable amounts of Cr(VI) from zinc yellow and chromite, but significant amounts are also obtained from the most insoluble Cr(VI) pigments. When BHK cells are treated with such preincubated solutions, reduction of soluble Cr(VI) to Cr(III) by cell metabolites is seen with all Cr(VI) compounds, accompanied by decreased cytotoxicity. The same differences between Cr(VI) and Cr(III) compounds apply to the cytotoxic effects on mitosis of HEp cells and the clastogenic effects on CHO cells. The activity of chromite, the only Cr(III) pigment capable of significantly increasing the frequency of SCE, is due to contamination with soluble Cr(VI). In contrast to the very low cytotoxicity of Cr(III), much higher chromium levels are detected in the cells incubated with soluble Cr(III) than with the same concentrations of soluble Cr(VI). 50% and 75% of chromium accumulated in the cells during treatments with Cr(VI) and Cr(III) respectively remains firmly bound to the cells, even when they are incubated for up to 48 h in normal growth medium. Chromium accumulated in the cells after treatment with Cr(III) is most probably bound to the cell membrane, whereas some of the Cr(VI) is transported through the cell membrane and reduced in the cell nucleus. The results of the present investigation are in agreement with those obtained with the same Cr(VI) and Cr(III) compounds in mutagenicity assays in bacteria and carcinogenicity tests in rodents. A re-evaluation of the mechanisms of chromium carcinogenisis is proposed.

Animals↗

The effectiveness of long-term supplementation of carbohydrate, chromium, fibre and caffeine on weight maintenance.

OBJECTIVE: To investigate whether supplementation of carbohydrate, chromium, dietary fibre and caffeine is effective for maintenance of weight-loss in the long-term. DESIGN: A longitudinal, double-blind, randomly assigned intervention study of 16 months with supplementation of either 50g of carbohydrates (CHO), 200 micrograms chromium-picolinate (Cr-Pic), 20g of soluble fibre plus 100 mg caffeine (CHO+) or 50g of plain CHO, for 16 months besides a very low energy diet (VLED) during the first two months. SUBJECTS: Thirty-three female obese subjects (age, 34.8 +/- 7.0 y; body weight (BW): 85.5 +/- 10.0 kg; body mass index (BMI) 31.2 +/- 3.7 kg.m-2) participated, 13 subjects were supplemented with CHO+, 11 subjects were supplemented with CHO and 9 subjects served as a control group. MEASUREMENTS: SW, body composition, energy intake and blood parameters were measured before the VLED (0), after the VLED at 2 months (2), and at 4, 10 and 16 months. RESULTS: The amount and course of relapse of BW was equal for the supplemented and control groups. The average regain at 16 months (the weight gained as a percentage of the total weight loss during the VLED) was 66.1 +/- 81.2%, and was not different between the groups. No differences in body composition were found between the groups at 16 months. The CHO supplements resulted in significantly elevated energy percentage (En %) intake of CHO daily, in both supplemented groups, although this did not result in less regain. Pearson correlation analysis for all subjects revealed that the more fat consumed, the more regain was found at 16 months (r = 0.41, P < 0.05). A high CHO consumption was correlated with less regain (r = -0.40, P = 0.05). Furthermore, chromium intake did not result in significant changes in blood parameters and body composition. CONCLUSION: Although additional supplementation of CHO, chromium, dietary fibre and caffeine intake did not affect BW, the En % CHO daily was increased significantly. Our results indicate that a high En% intake of CHO and a low En% intake of fat daily is beneficial for prevention of weight regain.

Adult↗

Determination and evaluation of hexavalent chromium in power plant coal combustion by-products and cost-effective environmental remediation solutions using acid mine drainage.

The chromium species leaching from a coal combustion fly ash landfill has been characterized as well as a novel approach to treat leachates rich in hexavalent chromium, Cr(VI), by using another natural waste by-product, acid mine drainage (AMD), has been investigated during this study. It is observed that as much as 8% (approximately 10 microg g(-1) in fly ash) of total chromium is converted to the Cr(VI) species during oxidative combustion of coal and remains in the resulting ash as a stable species, however, it is significantly mobile in water based leaching. Approximately 1.23 +/- 0.01 microg g(-1) of Cr(VI) was found in the landfill leachate from permanent deposits of aged fly ash. This study also confirmed the use of AMD, which often is in close proximity to coal combustion by-product landfills, is an extremely effective and economical remediation option for the elimination of hexavalent chromium in fly ash generated leachate. Speciated isotope dilution mass spectrometry (SIDMS), as described in EPA Method 6800, was used to analytically evaluate and validate the field application of the ferrous iron and chromate chemistry in the remediation of Cr(VI) runoff.

Acids↗

Heat treatment of cobalt-chromium alloy wire.

This study shows that the ability of cobalt-chromium wire to resist permanent deformation is definitely affected by the temperature of heat treatment. For each temperature of heat treatment up to 1200 degrees F there is progressively greater resistance to permanent deformation; at temperatures of heat treatment above 1200 degrees F, however, there is a rapid decline in resistance to permanent deformation due to partial annealing. The maximum resistance to permanent deformation occurs from heat treatment in the temperature range of 1100 degrees to 1200 degrees F. A clinician desiring maximum resistance to permanent deformation from a .016 inches x .022 inches cobalt-chromium archwire should heat-treat the wire at 1100 degrees to 1200 degrees F for 5 minutes in a dental furnace. If the wire was in a highly work-hardened condition as were the wire specimens of this study, he could expect an increase in resistance to permanent deformation of approximately 174 percent. Heat treatment at lower temperatures could be used in situations requiring less than maximum resistance to permanent deformation. Heat treatment at 900 degrees F would give approximately a 95 percent increase in resistance to permanent deformation. Of course, heat treatment would not be indicated when the desired level of resistance to permanent deformation was not greater than the amount exhibited in the untreated wires of this study. When an electrical resistance heat-treatment unit and 950 degrees F temper-indicating paste were used, the clinician would expect increased resistance to permanent deformation similar to that seen in the wires heat-treated with a dental furnace at 800 degrees and 900 degrees F, i.e., about half of that obtained by the 1200 degrees F treatment. This study has determined the effects that various temperatures of heat treatment have on the resistance to permanent deformation of cobalt-chromium wire specimens which were formed into a specific pattern of loops. The following conclusions can be drawn from the results of this investigation: 1. Heat treatment at 1200 degrees F gives the maximum resistance to permanent deformation to .016 inches x .022 inches cobalt-chromium wire. 2. Increases in resistance to permanent deformation of approximately 95 percent and 174 percent may be expected from heat treatment of .016 inches x .022 inches cobalt-chrome wire at 900 degrees and 1200 degrees, respectively. 3. Wires, heat-treated with an electrical resistance unit using 950 degrees F temper-indicating paste, exhibit increases in resistance to permanent deformation similar to wires heat-treated in a dental furnace at 800 degrees and 900 degrees F.

Chromium Alloys↗

Salivary nickel and chromium in patients with fixed orthodontic appliances.

The purpose of this study was to determine the alterations in the chromium and nickel concentrations in the saliva of orthodontic patients treated with fixed orthodontic appliances. Forty-five orthodontic patients were included in this study. The first group consisted of 15 patients (7 female, 8 male) with fixed appliances placed in their upper and lower arches. The second group consisted of 15 patients (8 female, 7 male) with a fixed appliance placed only in the upper arch. The control group consisted of 15 patients (7 female, 8 male) who were not undergoing orthodontic treatment. Four samples of stimulated saliva were collected from each patient before insertion of the fixed appliance, 1 week after insertion of the appliance, 1 month after insertion of the appliance, and 2 months after insertion of the appliance. The same 4 samples of saliva were collected from each control patient at the same time intervals as for the fixed-appliance groups. The chemical analyses were done with an electrothermal atomic absorption spectrophotometer (Perkin Elmer 2380, Perkin Elmer Corp, Baden Seewerk, Germany). The Wilcoxon matched-pairs signed ranks test was used to test differences between samples before and after insertion of orthodontic appliances. A Kruskal Wallis 1-way analysis of variance was used to test differences in nickel and chromium concentration among the 3 test groups. It was observed that there was a large variation in the concentrations of both nickel and chromium in saliva. No significant differences were found between the no-appliance group and the samples obtained after insertion of the appliances. The results of the study suggest that fixed orthodontic appliances do not significantly affect nickel and chromium concentrations of saliva during the first 2 months of treatment.

Adolescent↗

[Serum cobalt and serum chromium level in 2 patients with chronic renal failure after total hip prosthesis implantation with metal-metal gliding contact].

PURPOSE: The influence of chronic renal failure on serum cobalt and serum chromium in two patients with metal-on-metal bearing (Metasul) and cementless total hip arthroplasty (Alloclassic) is investigated. METHODS: Serum cobalt and serum chronium levels were determined in the postoperative course using atomic absorption spectrometry. RESULTS: Maximum values are found to be more than 100-fold elevated when compared to the reported median serum cobalt concentrations in patients with the same prosthesis type and no known renal disease. CONCLUSION: Chronic renal failure seems to be responsible for the marked elevation of serum cobalt and serum chromium. CLINICAL RELEVANCE: Despite evidence of adverse health reactions, a possible effect of long-term cobalt and chromium loading cannot be neglected. In our opinion, metal-on-metal bearings in THA should not be inserted in patients with chronic renal failure. Follow-up investigations (serum cobalt, serum chromium, serum creatinine, BUN, echocardiography) should be performed at short intervals.

Adult↗

Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks.

STATEMENT OF PROBLEM: Titanium is a biocompatible material, but it is not widely used in clinical dentistry for conventional removable denture frameworks. Little research exists on its applicability. PURPOSE: This study compared the casting accuracy and roughness of titanium and cobalt-chromium denture frameworks. MATERIAL AND METHODS: Twenty Kennedy Class II, Division 1 removable partial denture frameworks were fabricated with commercially pure titanium (n = 10) and a cobalt-chromium alloy (n = 10). The casting accuracy of each framework was determined by visual, radiographic, and microscopic methods. The roughness of each polished framework surface was analyzed with atomic force microscopy. RESULTS: The clinical fit, porosities, and microporosities of both types of metal frameworks were qualitatively similar. The surface roughness of polished pure titanium and cobalt-chromium frameworks was 104.43 +/- 69.24 nm and 133.91 +/- 40.92 nm, respectively. This difference was not statistically significant (P >.05). CONCLUSION: The clinical fit, porosity, and surface roughness of the titanium and cobalt-chromium frameworks fabricated for this study were comparable.

Biocompatible Materials↗

Effects of supplemental copper and chromium on the serum and egg traits of laying hens.

1. This study investigated the effects of supplemental copper and chromium on the serum and egg traits of laying hens using 144 forty-five-week-old White Leghorn layers. The hens were randomly assigned into 9 groups to conduct this 3 copper (0, 125 and 250 mg/kg as copper sulphate) x 3 chromium (0, 800 and 1600 microg/kg as chromium picolinate) factorial trial. 2. Egg yolk cholesterol was significantly reduced by supplementary copper (Cu) and chromium (Cr) and there was an interaction between Cu and Cr supplementation. Egg production, egg weight, eggshell strength and eggshell thickness were not influenced by Cu or Cr supplementation. 3. Serum cholesterol concentration was decreased by Cu supplementation and very low-density lipoprotein (VLDL) was reduced markedly by both Cu and Cr. On the other hand, high-density lipoprotein (HDL) was significantly increased by Cu and Cr. Interaction occurred between Cu and Cr in the VLDL and HDL parameters. Supplmentary Cu also reduced VLDL-cholesterol (VLDL-C) and enhanced HDL-cholesterol (HDL-C), while supplemental Cr had a contrary effect on these two parameters. 4. If minimum egg cholesterol content is the criterion, this study suggests that 125 mg/kg of Cu together with 800 to 1600 microg/kg of Cr provide adequate supplementary concentrations for laying hens.

Animal Feed↗

Chromium in foods and the diet.

Food is the main source of chromium intake by man. Chromium is fairly evenly distributed throughout the various food groups examined, but highest concentrations of chromium are found in the meat, fish, fruit and sugar groups. Mean dietary chromium intakes in the UK (1976-78) were between 80 and 107 micrograms/day.

Air↗

Biochemical study on the protective role of folic acid in rabbits treated with chromium (VI).

Deleterious effects of chromium (VI) compounds are diversified affecting almost all the organ systems in a wide variety of animals. Therefore, the present study was carried out to determine the effectiveness of folic acid (FA) in alleviating the toxicity of chromium (VI) on certain biochemical parameters, lipid peroxidation, and enzyme activities of male New Zealand white rabbits. Six rabbits per group were assigned to one of four treatment groups: 0 mg FA and 0 mg Cr(VI)/kg BW (control); 8.3 microg FA/kg BW; 5 mg Cr(VI)/kg BW; 5 mg Cr(VI) plus 8.3 microg FA/kg BW, respectively. Rabbits were orally administered their respective doses every day for 10 weeks. Results obtained showed that Cr(VI) significantly (P < 0.05) increased the levels of free radicals and the activity of glutathione S-transferase (GST), and decreased the content of sulfhydryl groups (SH groups) in liver, testes, brain, kidney, and lung. The activities of aspartate aminotransferase (AST), alanine aminotransferase (ALT), alkaline phosphatase (AlP), acid phosphatase (AcP), and lactate dehydrogenase (LDH) were significantly decreased in liver and testes due to Cr(VI) administration. Also, AlP and AcP activities were significantly decreased in kidney and lung. The activity of acetylcholinesterase (AChE) was significantly decreased in brain and plasma. Contrariwise, the activities of AST and ALT were significantly increased in plasma, while AlP and AcP decreased. Chromium (VI) treatment caused a significant decrease in plasma total protein (TP) and globulin, and increased total lipids (TL), cholesterol, glucose, urea, creatinine, and bilirubin concentrations. Folic acid alone significantly decreased the levels of free radicals in liver, brain, and kidney, and increased the content of SH-group. The activities of AST, ALT, and LDH in liver; AST, ALT, AlP, AcP, and LDH in testes; AcP in kidney; AlP and AcP in lung, and LDH in brain were significantly increased. Plasma TP and albumin were increased, while urea and creatinine were decreased. The presence of FA with Cr(VI) restored the changes in enzyme activities and biochemical parameters. In conclusion, folic acid could be effective in the protection of chromium-induced toxicity.

Administration, Oral↗