Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bone Cements”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Prophylaxis with systemic antibiotics versus gentamicin bone cement in total hip arthroplasty. A five-year survey of 1688 hips.

In Sweden in 1976, nine orthopedic departments organized a prospective, randomized, and controlled study in which the prophylactic effect of systemic antibiotics (SA) was compared to gentamicin bone cement (GBC) in 1688 consecutive total hip arthroplasties (THAs). After a follow-up period of one to two years, there was a statistically significant difference in the infection rate between the two groups in favor of the gentamicin cement. After five years or more, the difference was unaltered. Altogether, 16 deep infections had occurred in the SA group (1.9%) and seven (0.8%) in the GBC group. Roentgenographically, aseptic loosening had occurred in 29% and 24% of the hips in the SA and GBC groups, respectively, which suggests that admixture of the antibiotic did not weaken the cement. The results of this five-year review clearly showed the prophylactic value of gentamicin cement against deep infection after THA but did not support the hypothesis that this effect was prolonged over one year.

Adult↗

The influence of the time-dependent properties of bone cement on stress in the femoral cement mantle of total hip arthroplasty.

An empirically determined formula for the creep behavior of bone cement was incorporated into a validated computer model of a cemented femoral total hip arthroplasty component. The stress patterns in the cement mantle were observed over a period of one week, in one instance where the stem-cement interface was rigidly bonded, and in a second, where it was allowed to slip. Principal stresses and maximum shear stresses were shown to decrease rapidly after loading in both situations, suggesting that the stresses generated were not high enough to cause immediate failure, although they may be significant in the long term.

Journal Article↗

Detection of gentamicin emission from bone cement in the early postoperative period following total hip arthroplasty.

This article describes the characteristics of gentamicin emission from the bone cement-antibiotic complex in the early postoperative period following total hip arthroplasty. Gentamicin levels of the drain fluid taken at 6, 24, and 48 hours postoperatively were measured with a fluorescent polarization immunoassay method. Mean gentamicin concentrations were 2.6, 1.2, and 0.6 mcg/mL, respectively. Age, sex, and body mass index had no significant influence on the outcome. Results showed that the amount of gentamicin in the wound fluid is inversely proportional to the total amount excreted. Twenty-four hours postoperatively, the average gentamicin concentrations in the drain fluid taken from around the endoprosthesis implanted with Palacos-R bone cement (Zimmer Warsaw, Ind), diminished, yet remained above the minimal inhibitory concentration level.

Aged↗

Prophylaxis with systematic antibiotics versus gentamicin bone cement in total hip arthroplasty. A ten-year survey of 1,688 hips.

In 1976, nine Swedish orthopedic departments started a prospective, randomized, and controlled study in which the prophylactic effect of systematic antibiotics (SAs) was compared with gentamicin bone cement (GBC) in 1,688 consecutive total hip arthroplasties (THAs). After ten years, 13 deep infections had occurred in the SA group and nine in the GBC group. The earlier reported significant difference at two and five years in favor of GBC no longer existed. No allergic or toxic reactions have been reported in the GBC group.

Adult↗

Primary total hip arthroplasty without the use of bone cement: a 10-year follow-up of 157 hips.

BACKGROUND: The cementless fixation technique in total hip arthroplasty (THA) was developed to solve clinical problems such as aseptic loosening and osteolysis which were thought to be associated with the use of bone cement. This retrospective study reports our mid-term results with cementless THA. METHODS: A series of 173 consecutive, unselected cementless THA procedures using the Omnifit prosthesis was performed by a single surgeon. Sixteen hips were excluded from the study because of insufficient follow-up evaluation. One hundred and fifty-seven THAs with an average follow-up period of 10.2 (range, 5-12) years were retrospectively reviewed. RESULTS: The overall revision rate was 7.0%. Ninety-five percent of unrevised hips achieved a Merle D'Aubigne hip score of 16 points or above. Radiographically, bone ingrowth occurred in all unrevised cups, and in 95% of unrevised stems. Osteolytic lesions, seen on 28.1% of femora and 8.9% of pelvises, appeared at an average of 3.8 years postoperatively. Femoral osteolytic lesions were confined to the proximal Gruen zones 1 and 7. The mean annual polyethylene wear rate was 0.15 mm. Approximately 1/3 of the hips were noted to have excessive wear. CONCLUSION: These results suggest that cementless Omnifit THA provides stable fixation for as long as 12 years after implantation. Of significant concern is the high incidence of excessive polyethylene wear and associated osteolysis. Our experience also indicates that a femoral stem with a circumferential porous coating in the proximal region can protect the femur from distal osteolysis.

Adult↗

Transforming growth factor-beta1 incorporation in a calcium phosphate bone cement: material properties and release characteristics.

The bone regenerative properties of calcium phosphate cements (CPCs) may be improved by the addition of growth factors, such as recombinant human transforming growth factor-beta1 (rhTGF-beta1). Previously, we showed that rhTGF-beta1 in CPC stimulated the differentiation of preosteoblastic cells from adult rat long bones. The intermixing of rhTGF-beta1 in CPC, which was subsequently applied to rat calvarial defects, enhanced bone growth around the cement and increased the degradation of the cement. However, it is unknown whether the addition of rhTGF-beta1 changes the material properties of CPC and what the characteristics of the release of rhTGF-beta1 from CPC are. Therefore, we determined in this study the release of rhTGF-beta1, in vitro, from the cement pellets as implanted in the rat calvariae. The possible intervening effects of rhTGF-beta1 intermixing on the clinical compliance of CPC were studied through an assessment of its compressive strength and setting time, as well as its crystallinity, calcium-to-phosphorus ratio, porosity, and microscopic structure. We prepared CPC by mixing calcium phosphate powder (58% alpha-tricalcium phosphate, 25% anhydrous dicalcium phosphate, 8.5% calcium carbonate, and 8.5% hydroxyapatite) with a liquid (3 g/mL). The liquid for standard CPC consisted of water with 4% disodium hydrogen phosphate, whereas the liquid for modified CPC was mixed with an equal amount of 4 mM hydrochloride with 0.2% bovine serum albumin. The hydrochloride liquid contained rhTGF-beta1 in different concentrations for the release experiments. Most of the rhTGF-beta1 incorporated in the cement pellets was released within the first 48 h. For all concentrations of intermixed rhTGF-beta1 (100 ng to 2.5 mg/g of CPC), approximately 0.5% was released in the first 4 h, increasing to 1.0% after 48 h. Further release was only about 0.1% from 2 days to 8 weeks. CPC modification slightly increased the initial setting time at 20 degrees C from 2.6 to 5 min but had no effect on the final setting time of CPC at 20 degrees C or the initial and final setting times at 37 degrees C. The compressive strength was increased from 18 MPa in the standard CPC to 28 MPa in the modified CPC only 4 h after mixing. The compressive strength diminished in the modified CPC between 24 h and 8 weeks from 55 to 25 MPa. No other significant change was found with the CPC modification for rhTGF-beta1. X-ray diffraction revealed that standard and modified CPCs changed similarly from the original components, alpha-tricalcium phosphate and anhydrous dicalcium phosphate, into an apatite cement. The calcium-to-phosphorus ratio, as determined with an electron microprobe, did not differ for standard CPC and modified CPC. Standard and modified CPCs became dense and homogeneous structures after 24 h, but the modified CPC contained more crystal plaques than the standard CPC, as observed with scanning electron microscopy (SEM). SEM and back- scattered electron images revealed that after 8 weeks the cements showed equally and uniformly dense structures with microscopic pores (<1 microm). Both CPCs showed fewer crystal plaques at 8 weeks than at 24 h. This study shows that CPC is not severely changed by its modification for rhTGF-beta1. The prolonged setting time of modified cement may affect the clinical handling but is still within acceptable limits. The compressive strength for both standard and modified cements was within the range of thin trabecular bone; therefore, both CPCs can withstand equal mechanical loading. The faster diminishing compressive strength of modified cement from 24 h to 8 weeks likely results in early breakdown and so might be favorable for bone regeneration. Together with the beneficial effects on bone regeneration from the addition of rhTGF-beta1 to CPC, as shown in our previous studies, we conclude that the envisaged applications for CPC in bone defects are upgraded by the intermixing of rhTGF-beta1. Therefore, the combination of CPC and rhTGF-beta1 forms a promising synthetic bone graft.

Bone Cements↗

[Influence of the bone-cement mixing time on hypotonic blood circulation reactions in hip-joint replacement surgery].

The amount of methylmethacrylatemonomer that is released into the blood-stream, during the alloplastic replacement of the hip-joint, depends on the time taken to prepare the bone cement(so-called extracorporeal polymerization-time). In vitro experiments reveal that the release of monomers depends on the preparation time. Gas-chromatographic monomer determinations show, that by prolongation of the preparation time from 2 to 5 minutes, the amount of monomer released into the blood-stream is decreased by a factor of 7. With the increase in preparation time the number of hypotonic circulatory reactions caused by the monomers will decrease. Extension of the extracorporeal polymerization-time from 2 to 5 minutes decreases the incidence of intra-operative circulatory depressions from 95% to 26%. These results were obtained by intra-arterial measurements of the blood pressure in the radial artery.

Blood Circulation↗

The effect of bone cement used for stabilization of endoprostheses on blood clotting system activity.

The authors carried out studies of the blood clotting and fibrinolysis systems in 15 patients undergoing total endoprosthetic replacement of the hip joint with a McKee-Ferrara type of prosthesis and stabilized by Surgical Simplex Acrylic bone cement (North Hill Plastics, Ltd. London). The observations point to statistically significant changes in the blood clotting and fibrinolysis systems with a tendency towards hypercoagulation and intravascular clotting (DIC). Fibrinolysis activation associated with these changes is secondary, resulting among others, from the mechanism of the action of free fibrin monomers.

Anesthesia, General↗

Sarcoma of bone-cement membrane: a case report and review of the literature.

The development of a cancerous tumour at the site of total joint replacement is a rare but virtually always fatal event. The previously unreported scenario of a patient who was found to have a malignant fibrous histocytoma at the bone-cement membrane after revision for a loose total hip prosthesis is reported. Recent biologic information evaluating the response of mesenchymal cells to metallic debris suggests that the environment surrounding a loosened prosthesis may provide conditions appropriate for the development of a sarcoma.

Biopsy, Needle↗

[On the stress state of bone cement fixing a hip joint prosthesis (author's transl)].

Using a simplified model, tests were made to investigate the shear stress distribution at a hip joint prosthesis. A marked increase of stress at the tip of the prosthesis was found through photoelasticity. This peak stress resulted in a safety factor of 3 against exceeding the shear strength of bone cement. Since the calculation of the stress is based on unfavourable assumptions, the actual factor of safety should show a higher value still.

Bone Cements↗

Atlanto-axial fusion in rheumatoid arthritis. A new method of fixation with wire and bone cement.

Twenty-eight occipito-cervical fusions performed over the past 4 years in patients with rheumatoid arthritis are discussed. All of the patients with one exception had signs of neurological involvement preoperatively due to pressure on occipital nerve roots, spinal cord and/or vertebral arteries. A surgical technique using wire, pin and bone cement and permitting early mobilization without external fixation was used and is described in detail. The clinical results were excellent in 21 cases with an additional five patients showing improvement. One patient did not benefit from surgery and one had no symptoms preoperatively. The results are encouraging and the possibility of early mobilization (the day after surgery) is of the utmost importance for this group of patients.

Adult↗

Bone cement as an adjunct to medullary nailing in fractures of the distal third of the femur in elderly patients.

A modified method of internal fixation for fractures of the distal third of the femur in elderly patients is discussed. The procedure is also recommended for fractures due to secondary neoplasia. The method consists of medullary nailing with insertion of acrylic bone cement into the medullary canal. A series of 14 patients is presented, with an average age of 79.4 years, range 62-99 years (Table I). Two patients had suffered pathological fractures from myelomatosis; the other fractures involved the distal third of the femur which were often comminuted and/or in osteoporotic bone, thus rendering them unsuitable for more orthodox methods of fixation. Emphasis is placed on the possibility of early activity and the facilitation of nursing patients for whom long periods of rest in bed and traction should be avoided.

Aged↗