Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Assisted Circulation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Development and initial in vivo testing of a new hydraulic drive system (Paedipump) for circulatory support in infants.

The main limitation in the use of circulatory support in children is the lack of an adequate system with regard to size and pumping capacity. Recently, two pneumatically driven ventricular support systems with low volume chambers for use in a pediatric population became available. We have developed a hydraulic drive system with an advantageous exact control of the stroke volume. The system enables two different modes of operation: the full-empty and the filled-empty modes. In both cases the ventricle is empty at the end of systole. This new system was tested in experimental animals (6 pigs, body weight 9.5-14.0 kg) with normal and reduced left ventricular function (MAP<45 mmHg). A 25 ml ventricle (HIA-Medos) was implanted. The full-empty and the filled-empty mode used led to a significant load reduction, both in animals with normal and impaired cardiac function. Plasma lactate levels, pH-values and total body O2-consumption were in the normal range during circulatory support indicating adequate organ perfusion. Results showed that sufficient ventricular support was achieved during all pumping modes due to the possibility of controlling and modifying the stroke volume of the hydraulically driven support system employed according to necessity. This is a promising feature for its future application in infants with congenital or acquired heart diseases.

Animals↗

The muscle-powered dual-chamber counterpulsator: rheologically superior implantable cardiac assist device.

To enable long-term studies of a totally implantable cardiac assist device powered by transformed fatigue-resistant skeletal muscle, we developed a dual-chamber extraaortic counterpulsator implanted, 2 of which fluid for power transfer. Six dogs had our dual-chamber extraaortic counterpulsator implanted, 2 of which had undergone prior transformation of their latissimus dorsi muscle. The blood pump, with a Dacron graft at each end, was anastomosed end-to-side and parallel to the thoracic aorta, allowing continuous blood flow to minimize thrombus formation caused by stasis and turbulence. The blood pump was powered by a hydraulic bulb placed beneath the latissimus dorsi muscle. The latissimus dorsi muscle was stimulated to contract during diastole using a synchronized burst electrical stimulator. The ratio of diastolic pressure time product over systolic time tension index, which reflects the myocardial oxygen supply and demand ratio, was calculated from ascending aortic pressure tracings. A consistent increase in this ratio of 44% in 4 dogs with nontransformed latissimus dorsi muscle and of 70% in 2 dogs with transformed latissimus dorsi muscle was obtained when the device was activated. Preliminary chronic implantation studies using a Medtronic cardiomyostimulator (Model SP1005) as the burst stimulator for our dual-chamber extraaortic counterpulsator produced an average augmentation in aortic diastolic pressure of 34 mm Hg for up to six days. Our results indicate that, with further refinement of this device, a long-term totally implantable cardiac assist device powered by endogenous skeletal muscle will be feasible.

Animals↗

The thoratec ventricular assist device: a paracorporeal pump for treating acute and chronic heart failure.

The Thoratec Ventricular Assist Device (VAD) System (Thoratec Laboratories, Pleasanton, CA) is a paracorporeal pump that can provide univentricular or biventricular assistance for patients with heart failure. The system consists of a prosthetic ventricle that has a blood-pumping chamber of Thoralon (Thoratec Laboratories) polyurethane, cannulas for univentricular or biventricular support, and either a hospital-based pneumatic drive console or a portable battery-powered drive unit. For biventricular assistance, 2 pumps are used. The Thoratec voluntary registry indicates that, as of May 2000, this system had been implanted in 1,376 patients, mainly for bridging to transplantation (828 patients) or postcardiotomy support (195 patients); the remaining 353 patients received a hybrid configuration of the device or had incomplete information, so they are not included in this analysis. In the 828 bridge-to-transplant patients, the Thoratec system provided biventricular assistance in 472 cases, left ventricular assistance in 326 cases, and right ventricular assistance in 30 cases for up to 515 days. During the support period, the cardiac index increased significantly from 1.4 +/- 0.8 L/min/m2 to 3.0 +/- 0.5 L/min/m2 (with biventricular assistance and left ventricular cannulation). Sixty percent of the 828 patients underwent transplantation, and the posttransplant survival rate was 86%. In the 195 patients who needed postcardiotomy support, VADs were used for up to 80 days for cardiac recovery. Thirty-eight percent of the patients were weaned from the VAD, and 59% of the weaned group were discharged from the hospital. In addition, 49 postcardiotomy patients were considered for transplantation; of these, 32 received a transplant and 23 were discharged. Patient mobility is being improved by the use of a portable driver. The Thoratec VAD is suitable for a wide range of applications, and efforts are underway to facilitate patient mobility and allow hospital discharge. An intracorporeal version of the VAD, which is currently under development, will help achieve these goals.

Adult↗

Development of autonomous paracorporeal and implanted artificial heart and circulatory assist systems.

The development of autonomous systems for the artificial heart (AH) and for circulatory assistance (CA) has taken several directions. Studies relating to one direction--the development of paracorporeal and implanted systems based on thermal or electric motors--have been conducted at our institute in two stages, moving from stationary systems to totally implanted systems for long-term use. The development of these systems is described. Improvements in the linear solenoid motor, used in some of the first paracorporeal systems, enabled progress toward the development of implanted CA systems based on a reversing electrohydraulic actuator. Modifications were also made in the control system. Early animal testing of these systems indicated that they could be effective in unburdening the heart cavities during left and right bypasses. Full implantation, however, demanded that the devices have improved forms and dimensions and less weight. Smaller electromechanical systems are being developed, and we are experimenting with ways to increase the overall autonomy of the system. An orthotopic model of an implanted AH is promising. Experiments continue on the use of the body's own skeletal muscles to create a blood pump.

Animals↗

Current status of the gyro centrifugal blood pump--development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO project).

The New Energy and Industrial Technology Development Organization (NEDO) project was started in 1995. The goal is the development of a multipurpose, totally implantable biventricular assist device (BVAD) that can be used for any patient who suffers from severe heart failure. Our C1E3 (two-week pump) centrifugal pump, called the Gyro pump, has three design characteristics: a magnetic coupling and double pivot bearing system, an eccentric inlet port, and secondary vanes on the bottom of the impeller. The pump was miniaturized. The C1E3 evolved into the NEDO PI-601, a totally implantable centrifugal pump for BVAD. The current NEDO PI-710 pump (five-year pump) system includes a centrifugal pump with pivot bearings, a hydraulically-levitated impeller, an rpm-controlled miniaturized actuator (all-in-one actuator plus controller), an emergency clamp on the left outflow, and a Frank-Starling-type flow control. The final mass production model is now finalized, and the final animal study and two-year endurance studies are ongoing.

Assisted Circulation↗

Flow visualization in a centrifugal blood pump with an eccentric inlet port.

Flow visualization analysis was applied to the Baylor/Miwatec centrifugal artificial heart to evaluate its fluid dynamic characteristics regarding antithrombogenicity. An eccentric vortex was found both in the upper and the lower gaps of the impeller, which is supposed to be caused by the eccentric inlet port. Therefore, one-way flow toward the outlet is formed and washes the pivot. The combination of an eccentric vortex and a pivot bearing that is washed is unique to the Baylor/Miwatec pump. For the male pivots exposed to periodic wash, the minimum shear rate around the bottom pivot was estimated to be 650/s, which is higher than the threshold for thrombus formation shown by other studies. The wall shear rate at the impeller bottom surface was found to be larger in the top contact mode than in the bottom contact mode.

Assisted Circulation↗

Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics.

A mixed-flow blood pump for long-term applications has been developed at the Helmholtz-Institute in Aachen, Germany. Central features of this implantable pump are a centrally integrated motor, a blood-immersed mechanical bearing, magnetic coupling of the impeller, and a shrouded impeller, which allows a relatively wide clearance. The aim of the study was a numerical analysis of hydraulic and hemolytic properties of different impeller design configurations. In vitro testing and numerical simulation techniques (computational fluid dynamics [CFD]) were applied to achieve a comprehensive overview. Pressure-flow charts were experimentally measured in a mock loop in order to validate the CFD data. In vitro hemolysis tests were performed at the main operating point of each impeller design. General flow patterns, pressure-flow charts, secondary flow rates, torque, and axial forces on the impeller were calculated by means of CFD. Furthermore, based on streak line techniques, shear stress (stress loading), exposure times, and volume percentage with critical stress loading have been determined. Comparison of CFD data with pressure head measurements showed excel-lent agreement. Also, impressive trend conformity was observed between in-vitro hemolysis results and numerical data. Comparison of design variations yielded clear trends and results. Design C revealed the best hydraulic and hemolytic properties and was chosen as the final design for the mixed-flow rotary blood pump.

Algorithms↗

Magnevad--the world's smallest magnetic-bearing turbo pump.

The first animal implant of our Magnevad LVAD is scheduled for the fourth quarter of 2003. This is being performed by the George E. Reed Heart Center of Westchester Medical Center and by New York Medical College; both are in Valhalla, NY. This article summarizes 3 years of development of the miniature axial flow LVAD. Our LVAD has new innovations not found in any other turbo pump to minimize thrombus, blood turbulence, flow separation, and the generation of microemboli. The Magnevad is only 25 mL in volume, similar in size to the Micromed & Jarvik 2000 axial flow turbo pumps that have contacting bearings. US Patent 6 527 699 was issued to Gold Medical on March 4, 2003 and World Wide PCT patents are pending. The discussed improvements (patents pending) are designed to minimize flow separation and turbulence, the precursors of microemboli that lodge in end organs. This problem has been largely ignored in the published literature. A new long-term stable miniature ultrasonic position sensor is used for bearing control. It measures the axial position of the rotor to obtain LVAD differential pressure. Differential pressure is used to obtain pulsating flow and automatic physiologic control. The term "fourth generation pump" is being coined for the Magnevad because in addition to being noncontacting, it inherently measures pump differential pressure on which physiologic control can be based.

Animals↗

Atrial cardiomyoplasty after Fontan-type procedures.

The purpose of right atrial cardiomyoplasty is to increase atrial-pulmonary flow in patients undergoing Fontan-type procedures. We developed two surgical techniques to bypass the right ventricle, followed by right atrial cardiomyoplasty with a stimulated latissimus dorsi muscle flap (LDMF). In 10 goats, the left LDMF was transferred into the chest by removal of the second rib. After sternotomy, the right atrial appendages of five goats (group 1) were connected to the distal main pulmonary artery with polytetrafluoroethylene tubing and the proximal pulmonary trunks were ligated. In the other five goats (group 2), under cardiopulmonary bypass, bioprosthetic valves were implanted into the inferior venae cavae. The tricuspid orifice was closed, and the atriopulmonary connection was performed. The left LDMF was sutured over the right atrium and stimulated using synchronous 30-Hz bursts of impulses delivered by a Medtronic Cardiomyostimulator. Hemodynamic studies were performed in the acute phase. Right atrial, pulmonary arterial, and aortic pressures were assessed. Cardiac output was measured using ultrasonic flow studies. LDMF stimulation restored pulsatile pressure patterns in the pulmonary artery and increased the cardiac output. These observations were more evident in the model with caval valvular implant. This functional "ventricularization" of the right atrium could improve long-term results after Fontan-type procedures and extend operative indications. Chronic experimental studies are necessary to evaluate the diastolic and systolic functions of the neo-right ventricle.

Animals↗