Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AUSCULTATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour.

BACKGROUND: Cardiotocography (sometimes known as electronic fetal monitoring), records changes in the fetal heart rate and their temporal relationship to uterine contractions. The aim is to identify babies who may be short of oxygen (hypoxic), so additional assessments of fetal well-being may be used, or the baby delivered by caesarean section or instrumental vaginal birth. OBJECTIVES: To evaluate the effectiveness of continuous cardiotocography during labour. SEARCH STRATEGY: We searched the Cochrane Pregnancy and Childbirth Group Trials Register (March 2006), CENTRAL (The Cochrane Library 2005, Issue 4), MEDLINE (1966 to December 2005), EMBASE (1974 to December 2005), Dissertation Abstracts (1980 to December 2005) and the National Research Register (December 2005). SELECTION CRITERIA: Randomised and quasi-randomised controlled trials involving a comparison of continuous cardiotocography (with and without fetal blood sampling) with (a) no fetal monitoring, (b) intermittent auscultation (c) intermittent cardiotocography. DATA COLLECTION AND ANALYSIS: Two authors independently assessed eligibility, quality and extracted data. MAIN RESULTS: Twelve trials were included (over 37,000 women); only two were high quality. Compared to intermittent auscultation, continuous cardiotocography showed no significant difference in overall perinatal death rate (relative risk (RR) 0.85, 95% confidence interval (CI) 0.59 to 1.23, n = 33,513, 11 trials), but was associated with a halving of neonatal seizures (RR 0.50, 95% CI 0.31 to 0.80, n = 32,386, nine trials) although no significant difference was detected in cerebral palsy (RR 1.74, 95% CI 0.97 to 3.11, n = 13,252, two trials). There was a significant increase in caesarean sections associated with continuous cardiotocography (RR 1.66, 95% CI 1.30 to 2.13, n =18,761, 10 trials). Women were also more likely to have an instrumental vaginal birth (RR 1.16, 95% CI 1.01 to 1.32, n = 18,151, nine trials). Data for subgroups of low-risk, high-risk, preterm pregnancies and high quality trials were consistent with overall results. Access to fetal blood sampling did not appear to influence the difference in neonatal seizures nor any other prespecified outcome. AUTHORS' CONCLUSIONS: Continuous cardiotocography during labour is associated with a reduction in neonatal seizures, but no significant differences in cerebral palsy, infant mortality or other standard measures of neonatal well-being. However, continuous cardiotocography was associated with an increase in caesarean sections and instrumental vaginal births. The real challenge is how best to convey this uncertainty to women to enable them to make an informed choice without compromising the normality of labour.

Cardiotocography↗

Prevalence of mitral-valve prolapse in the Stickler syndrome.

An increased prevalence of mitral-valve prolapse occurs in several connective tissue dysplasias, including Marfan syndrome, Ehlers-Danlos syndrome, and pseudoxanthoma elasticum. We evaluated 57 patients diagnosed as having the Stickler syndrome for mitral-valve prolapse by auscultation and two-dimensional echocardiography. The diagnosis was made on the basis of craniofacial and musculoskeletal abnormalities, sensorineural hearing loss, eye defects, and a family history of Stickler syndrome. Twenty-six patients (45.6%) had mitral-valve prolapse, including 11 of 22 females (50.0%) and 15 of 35 males (42.9%). The age range of our study population was 4 to 60 years. Prevalence of mitral-valve prolapse did not increase with age. Nine patients (34.6% of those with mitral-valve prolapse) had the click-murmur syndrome; only one of them was symptomatic. Because of the growing list of complications associated with mitral-valve prolapse, all patients with Stickler syndrome should be evaluated by auscultation, electrocardiogram, and echocardiography. Those with mitral-valve prolapse should be advised to have periodic follow-up and to instruct physicians caring for them of their need for antibiotic prophylaxis with certain surgical procedures.

Adolescent↗

Duplex pulsed Doppler echocardiography in mitral regurgitation.

The accuracy of duplex pulsed Doppler echocardiography (d-PDE) for detecting mitral regurgitation was evaluated in 35 patients undergoing d-PDE, cardiac auscultation, and left ventriculography. With three transducer positions, the overall d-PDE sensitivity was 95%, specificity was 100%, positive predictive value was 100%, negative predictive value was 94%, and diagnostic accuracy was 97% compared with ventriculography. This technique was superior to auscultation (sensitivity 74%, specificity 94%, positive predictive value 93%, negative predictive value 75%, diagnostic accuracy 83%). No false-positive d-PDE results occurred, but discordant false-negative results occurred frequently among the three transducer positions. If discordant negative results are considered to be false negative, then d-PDE is both sensitive and specific when mitral regurgitation is defined as systolic spectral broadening in any one transducer position.

Echocardiography↗

Mitral valve prolapse in myotonic dystrophy.

Forty-three patients with myotonic dystrophy (MyD) and 43 age- and sex-matched controls were prospectively evaluated for mitral valve prolapse (MVP) using both cardiac auscultation and echocardiography (ECHO). Prevalence of MVP was significantly increased in MyD patients when using either abnormal auscultation plus abnormal ECHO (23.3%, P less than 0.02) or abnormal ECHO alone (30%, P less than 0.01) as diagnostic criteria for MVP. Frequency of MVP was even more increased in patients with a thin, flat chest compared with patients with normal physical appearance (P less than 0.007). These findings are in support of the concept that the increased frequency of MVP in neuromuscular disorders is likely due to geometrical changes of the heart caused by thorax deformities, rather than structural changes of the mitral valve. For this reason, MVP in MyD probably belongs to the entity of so-called benign, secondary MVP. This is further supported by the absence of symptoms of "systemic" complications of MVP in our patient population.

Adolescent↗

An acoustic profile of normal swallowing.

Cervical auscultation has been proposed as a technique to augment the clinical evaluation of dysphagia to improve its accuracy in the diagnosis of dysphagia. Before using cervical auscultation to reliably diagnose disordered swallowing, it is necessary to first acoustically characterize normal swallowing for comparison with dysphagic swallowing. Ninety-seven healthy adult participants consumed teaspoon boluses of various consistencies while the sounds of swallowing were recorded. Descriptive statistics were reported for measures of duration, intensity, and frequency of the acoustic swallowing signal. Correlations between the variables and between bolus consistencies were computed. Overall, results compared favorably with previous research. Significant correlations were found among several of the variables, including an increasing duration of the acoustic swallowing signal with increasing age and decreasing intensity of the signal with increasing age. None of the variables differed significantly as a function of gender. Of potential clinical relevance, significant correlations between bolus consistencies for the duration and intensity variables indicated relative similarities across bolus consistencies. Duration and intensity of the acoustic signal appeared to be the most reliable of the variables measured. These results could serve as a reference point for future studies into normal swallowing across multiple bolus consistencies and volumes and eventually be compared with disordered swallowing.

Acoustics↗

Effects of hydration on mitral valve prolapse.

We investigated the effect of hydration on mitral valve prolapse (MVP). Ten subjects with documented diagnosis of MVP were studied before and after oral hydration with 1 L of fluid. Increased weight and cardiac output were present after hydration. Results showed that all 10 subjects with diagnosis of MVP before hydration continued to have MVP after hydration; however, subtle changes were detected, especially on auscultation. Seven of 9 subjects (with cardiac examination recorded before and after hydration) had auscultatory findings of MVP before hydration. No detectable auscultatory change after hydration was present in one subject; in six subjects a loss of either a click or a murmur was detected after hydration. All subjects had echocardiographically detected MVP before hydration; evidence of MVP on two-dimensional or M-mode examination persisted after hydration in all 10 subjects. Minor changes in the echocardiographic examination (M-mode n = 2, Doppler n = 1) were detected in three subjects. Thus we found that hydration of subjects with MVP did not alter the overall diagnosis; however, changes occurred, especially on auscultation. This suggests that alterations in hydration may affect auscultatory expression of MVP and could explain, in part, the variable auscultatory findings in patients with MVP.

Adult↗

Auscultatory perception of the fourth heart sound: effects of interval form fourth to first sound (S4-S1) and aging.

A clinically heterogeneous group of 48 subjects (aged 19 to 76 years) were searched for a fourth heart sound (S4) by three independent "blind" auscultators. Phonocardiograms recorded immediately after auscultation were measured by another "blind" observer. An S4 was identified in 32 subjects (67 per cent) in phonocardiograms with nominal filter peaks of both 70 and 35 hertz. Results in these subjects revealed two groups by auscultatory performance: those with an "easily heard" and those with an "easily missed" S4. Subjects with an "easily missed" S4 were significantly younger than those with an "easily heard" S4 (31.2 +/- 2.8 years versus 50.0 +/- 4.0 years, P less than 0.001). P-R and P-S4 intervals and relative amplitude of S4 (ratio of fourth to first heart sound [S1] amplitude) were not significantly different in the two groups. Splitting of the first heart sound (S1) was observed more frequently in the phonocardiogram of patients with an "easily missed" S4, but this trend did not reach statistical significance. The interval between S4 and the low frequency component of S1 was significantly short in those with an "easily heard" S4 (49.4 +/- 4.1 msec versus 70.0 +/- 5.0 msec, P less than 0.005). The mean S4-S1 (low frequency component) interval for the group with an "easily heard" S4 approximated 1 cycle length for S4 vibrations, a finding consistent with temporal acoustic summation. An alternate hypothesis is modification of S1.

Adult↗

Detection of mild aortic regurgitation by range-gated pulsed Doppler echocardiograhy.

In order to assess the sensitivity and specificity of the range-gated pulsed Doppler echocardiogram for the detection of aortic regurgitation, a study with use of this technique was carried out in 46 patients. They were classified into 3 groups: Group I was composed of 19 patients with a variety of heart diseases but with a competent aortic valve. Cardiac catheterization revealed no aortic regurgitation in any of the 19 patients, and the Doppler echocardiogram detected no turbulent diastolic flow in the left ventricular outflow tract. Group II was composed of 17 patients who clinically and by auscultation had aortic regurgitation, which was confirmed by cardiac catheterization in 6. In all 17 patients the Doppler echocardiogram detected several grades of turbulent diastolic flow compatible with aortic regurgitation in the left ventricular outflow tract. Group III was composed of 10 patients with aortic regurgitation but without the expected clinical or auscultatory evidence. The echocardiogram detected mitral valve flutter in only 1 patient. Cardiac catheterization revealed aortic regurgitation graded 1/4 and 2/4 in 9 patients, and the patient who did not undergo catheterization had a murmur of aortic insufficiency 6 months later. In all 10 patients the Doppler echocardiogram detected a regurgitating turbulent flow compatible with aortic regurgitation in the left ventricular outflow tract. It is concluded that the Doppler echocardiogram was more useful than auscultation and echocardiography for the detection of mild aortic regurgitation. In this study the range-gated pulsed Doppler echocardiogram proved 100% sensitive and specific. However, it will be necessary to study larger groups in order to assess its utility in more complicated conditions (obesity, emphysema, and heart failure) and the differential diagnosis with other diastolic murmurs.

Adolescent↗

An assessment of continuous fetal heart rate monitoring in labor. A randomized trial.

Intrapartum continuous fetal heart rate monitoring has been routinely performed at the Jessop Hospital for Women for some years. However, no controlled trials had ever been performed to show its advantages over intermittent auscultation in low-risk patients. A prospective randomized study of 504 patients compared continuous fetal heart rate monitoring with intermittent auscultation. There was no significant difference between the two groups in neonatal deaths, Apgar scores, maternal and neonatal morbidity, and cord blood gases. The cesarean section rate was significantly increased (p less than 0.05) in the monitored patients but this did not seem attributable to fetal monitoring. No beneficial or deleterious effects of continuous fetal heart rate monitoring in labor were shown.

Adult↗

Sex difference in the mechanical properties of the abdominal aorta in human beings.

PURPOSE: A previous study has shown age- and sex-related differences in abdominal aortic compliance. In that study blood pressure determined by auscultation in the brachial artery was assumed to be equal to blood pressure in the abdominal aorta. To validate our findings we investigated the pressure-diameter (P-D) relationship of the abdominal aorta. METHODS: Diameter and pulsatile diameter change of the abdominal aorta were determined noninvasively by an ultrasound phase-locked echo-tracking system with simultaneous measurement of aortic pressure resulting in P-D curves in 27 healthy male and female volunteers 23 to 72 years of age. The degree of error in aortic compliance as calculated from blood pressure determined by auscultation of the brachial artery rather than from direct measurement of aortic pressure was evaluated. Compliance was defined as the inverse of pressure strain elastic modulus (Ep) or of stiffness (beta). RESULTS: There was no significant difference in the systolic pressure at the two sites, but the diastolic pressure was systematically overestimated by approximately 10 mm Hg when determined by the auscultatory method (p < 0.01) leading to a 15% to 20% underestimation of Ep and stiffness (beta). The individual P-D curves exhibited hysteresis, were nonlinear, and revealed that the aorta is more distensible at lower than at higher pressures. The steepness of the P-D curve decreased with increasing age and this occurred at an earlier age in men than in women. CONCLUSION: This investigation demonstrates a decrease in abdominal aortic wall distensibility with age, which occurs at an earlier age in men, and confirms earlier results by use of the indexes Ep and stiffness (beta). This implies that the abdominal aorta in men is more prone to degenerative changes, which may be one of the factors responsible for the sex difference in aortic vascular disease.

Adult↗

The effectiveness of esophageal stethoscopy in a simulated in-flight setting.

PURPOSE: Previous research has confirmed the inability of flight nurses in an airborne BO-105 helicopter to hear breath sounds using normal or amplified transthoracic stethoscopy. The purpose of this study was to determine whether esophageal stethoscopy enabled effective auscultation of breath sounds in a simulated in-flight environment. METHODS: The cabin-sound environment of an in-flight BO-105 was recorded and recreated in an audiology laboratory, where five flight nurses were evaluated listening to taped breath sounds via an esophageal stethoscope. This audiotape model, validated in a previously published study, used a tape consisting of 24 20-second segments. Each segment, the beginning of which was marked with a beep signal, consisted of 20 seconds of silence or breath sounds. The distal (esophageal) end of the esophageal stethoscope was attached to the tape recorder; the intensity level of breath sounds heard at the stethoscope earpiece was calibrated to equate the sound level of actual esophageal breath sounds recorded on a volunteer. RESULTS: All nurses correctly identified the 24 taped segments as silent or including breath sounds 100% of the time. CONCLUSION: In the simulated environment tested, esophageal stethoscopy enabled 100% accuracy in identification of breath sounds, as compared with previously reported 0% efficacy for standard transthoracic auscultation. Study in the actual patient-care environment is indicated to confirm the usefulness of esophageal stethoscopy in the in-flight setting.

Air Ambulances↗

Validation of heart and lung teleauscultation on an Internet-based system.

The feasibility and accuracy of an Internet-based system for teleauscultation was evaluated in 103 cardiac patients, who were auscultated by the same cardiologist with a conventional stethoscope and with an Internet-based method, using an electronic stethoscope and transmitting heart and lung sounds between computer work stations. In 92% of patients, the results of electronic and acoustic auscultation coincided, indicating that teleauscultation may be considered a reliable method for assessing cardiac patients and could, therefore, be adopted in the context of comprehensive telecare programs.

Aged↗

Auscultatory bedside tests for thoracic aortic disease.

Auscultation for thoracic aortic aneurysms and dissections is largely limited to listening to praecordium, neck and axillae associated with disease located at the ascending aorta and root, typically overlooking the descending thoracic aorta. We report a new test and protocol for differentiating aortic root and descending aortic disease by adding auscultation over the back as part of the cardiovascular examination.

Aortic Dissection↗

Accuracy of clinical assessment of infant heart rate in the delivery room.

Heart rate (HR) dictates intervention during neonatal resuscitation. Guidelines recommend that HR be assessed by auscultation or palpation. We compared HRs determined clinically with electrocardiography (ECG) in healthy newborns in the delivery room. Clinical assessment by 23 observers randomly allocated to assess HR by one of two methods in 26 infants, was found to be inaccurate and underestimate ECG HR. The mean difference between HR assessed by auscultation and palpation ECG and HR using methodology recommended by the Neonatal Resuscitation Programme was 14 and 22 beats per minute respectively.

Delivery Rooms↗

A controlled trial of the differential effects of intrapartum fetal monitoring.

A controlled prospective study of the differential effects of intrapartum fetal monitoring on mothers and infants has been conducted at Denver General Hospital, Denver, Colorado. A total of 690 high-risk obstetric patients in labor were randomly assigned to one of three monitoring groups--auscultation, electronic fetal monitoring alone, or electronic monitoring with the option to scalp sample. There were no differences in immediate infant outcomes in any measured category (Apgar scores, cord blood gases, neonatal death, neonatal morbidity, nursery course) among the three groups. There were no differences in rates of infant or maternal infections. The cesarean section rate was markedly increased in the electronically monitored groups, especially in the electronically monitored alone (18%) as compared with the auscultated (6%) (P less than 0.005). In this controlled trial electronic monitoring did not improve neonatal outcomes and the mothers were at increased risk of cesarean section.

Apgar Score↗

[Non-aggressive diagnostic approach to invasive pulmonary aspergillosis in a hematology unit. Retrospective analysis of a series of 16 cases].

PURPOSE: Among neutropenic patients, diagnosis of invasive pulmonary aspergillosis is difficult. Computed tomographic scan, bronchoalveolar lavage and histology are considered invasive procedures, because they represent an infectious risk for these immunocompromised patients. METHODS: We describe the clinical and noninvasive paraclinical (X-rays, serology) signs of invasive pulmonary aspergillosis, from a retrospective study of 16 cases in a haematology unit. RESULTS: Outside of fever and chills, cough and polypnea are the earliest signs, followed by chest pain, dyspnea, lung auscultation changes, and haemoptysis. The sensitivity of each sign is higher than 56%. Before the onset of lung auscultation changes, the chest X-ray shows mainly unilateral alveolar infiltrates. Sensitivity of serology is weak (25%), but contributed to early diagnosis in 16.6% of cases. CONCLUSION: A better knowledge of the invasive pulmonary aspergillosis clinical, radiological and serological signs could help the practician to prescribe an 'invasive' investigation (computed tomographic scan, bronchoalveolar lavage) to confirm the diagnosis of this fungal infection.

Aspergillosis↗

Initial clinical evaluation of cardiac systolic murmurs in the ED by noncardiologists.

It is not exactly known how ED physicians perform in evaluating cardiac systolic murmurs. In 203 consecutive medical ED patients with systolic murmur, we compared the initial clinical evaluation, including auscultation, with transthoracic echocardiography. Of the 203 patients, 132 (65%) had innocent murmurs and 71 patients (35%) had valvular heart disease. Sensitivity and specificity of the initial clinical routine evaluation in diagnosing echocardiographic valvular heart disease were 82% (70%-86%) and 69% (60%-76%), respectively. Independent significant positive predictors of valvular heart disease were grade >2/6 systolic murmur (odds ratio [OR], 8.3; confidence interval [CI], 3.5-19.7, P<.001) and pathologic electrocardiogram (ECG) (OR, 8.4; CI, 3.2-22, P<.001. Patients younger than 50 years with a systolic murmur graded < or =2/6 had innocent murmurs in 98%. The initial clinical evaluation, including auscultation, by experienced ED physicians in internal medicine distinguishes well between innocent murmurs and valvular heart disease in medical patients with cardiac systolic murmurs.

Adolescent↗

Assessment of the ruminant respiratory system.

With practice, complete use of the methods of this assessment: history, detailed examination of the head and neck, cough induction, chest auscultation and percussion, and chest auscultation following forced rebreathing can be completed within 10 minutes. The examination can provide a great deal of new information regarding the respiratory system that would go undetected on a more general physical examination. In cases in which the diagnosis is still in question or requires confirmation, this will also enable the optimal use of appropriate ancillary tests, as described in the article on ancillary testing for the respiratory tract elsewhere in this issue.

Animals↗