Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AIR CONDITIONING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

[Air transport of pregnant women].

Note is taken of the fact that air travel is increasingly frequent on the part of persons of nearly all categories. The effect of hypoxia due to altitude on the body, especially during pregnancy, is considered. Particular attention is given to vasomotor activity, uterine contractility and anxiety. Flight in air-conditioned, pressurised cabins with reduced noise and vibration is recommended for pregnant women, following obstetric examination to see whether the history contraindicates travel by air. Elementary recommendations are made with respect to what should be done during the journey.

Adult↗

In vivo efficacy of two heated humidifiers used during CPAP-therapy for obstructive sleep apnea under various environmental conditions.

STUDY OBJECTIVES: To investigate the humidification performance-defined as the maximum achievable absolute humidity in the CPAP tube-of two heated humidifier systems (HH) offered as CPAP accessories, as a function of ambient air conditions. DESIGN: In 48 patients undergoing CPAP treatment, temperature (T) and relative humidity (RH) in the distal CPAP tube system were measured, with and without either of the two heated humidifiers A (HH-A, n=23), or B (HH-B, n=25), until a steady state was achieved. At the same time, ambient T and RH in the examination room were recorded. T and RH were used to calculate the absolute humidity (AH). SETTING: University Hospital, Erlangen, Germany. PATICIPANTS: 48 patients with obstructive sleep apnea undergoing CPAP therapy. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: Conditions in the examination room during measurement with the HH-A, T = 22.5+2.1 (16.4-26.0) degrees C and AH = 9.3+2.4 (5.3-13.9) g/m3 did not differ significantly from those prevailing during measurements with the HH-B, T = 22.9+1.9 (18.9-26.3) degrees C and AH = 9.9+2.8 (6.2-16.4) g/m3. The mean humidification performance (steady state AH with HH within the CPAP tube) of the HH-A was 23.5+2.9 (19.1-29.9) g/m3, that of the HH-B 26.8+3.9 (21.0-34.4) g/m3. CONCLUSIONS: Under the ambient conditions of humidity and temperature, commonly found in European and North American bedrooms, both HH demonstrate a high humidification performance that even falls within the range recommended for intubated patients. The difference between the two HH is small, and probably not clinical relevant. Thus, it would appear that both HH are suitable for the treatment of dry upper airways under CPAP therapy.

Environment↗

Regional control of local airway heat and water vapor losses.

The regulation of local heat and water vapor losses along the respiratory tract is examined based on a theoretical model of respiratory air conditioning and physiological data. The theoretical model is a quasi-steady one-dimensional model descriptive of the localized process of heat and water transport within the airways. During nasal breathing the model is most sensitive to the following two parameters: 1) the gradient of blood temperature along the airway wall and 2) the nasal air space volume. Thermoregulatory control of these two factors within the primary conditioning region, the upper airway, establishes the overall respiratory heat and water loss. Upper airway thermoregulation, however, also effects the heat and water demands placed on the secondary conditioning region, the tracheobronchial airways. Similar to the upper airway, the tracheobronchial airway wall temperature varies in response to changing demands. The bronchial circulation is shown to provide a major source of heat within the first several bronchial generations where the greatest heat and water fluxes within the lung are predicted to occur. Control of the bronchial blood flow may therefore directly influence the bronchoconstrictive response in asthmatics.

Body Temperature Regulation↗

Morphological changes of clefts in Plasmodium-infected erythrocytes under adverse conditions.

Blood infected with human or rodent malaria parasites, Plasmodium falciparum or Plasmodium berghei, was exposed to higher pH, higher PO2, and lower temperature than those used in standard cultivation conditions. Parasitized blood was incubated for 20, 25, and 30 min with RPMI 1640 medium, 10% (vol/vol) serum, pH 8.0, at 20 degrees C in the air, conditions which are ultimately lethal to the asexual stages of malarial parasites. Markedly dilated clefts were observed in the cytoplasm of the malaria-infected erythrocytes so treated. These clefts can take up colloidal gold particles and macromolecules such as Protein A, rhodamine-dextran, and lucifer yellow-dextran. Such dilated clefts were not seen in the cytoplasm of infected erythrocytes that were incubated under normal cultivation conditions before fixation. These had slender clefts of the usual sort that did not take up colloidal gold particles and macromolecules.

Animals↗

A survey of public perception and response to heat warnings across four North American cities: an evaluation of municipal effectiveness.

To examine the efficacy of municipal heat watch warning systems, a thorough evaluation of the heat mitigation plans of four North American cities--Dayton (Ohio, USA), Philadelphia (Pennsylvania, USA), Phoenix (Arizona, USA), and Toronto (Ontario, Canada)--was undertaken. In concert with this evaluation was a survey of residents in the metropolitan areas of these cities that gauged their perception of their own vulnerability to the heat, as well as their knowledge of heat warnings and the activities recommended to be undertaken to help mitigate the effects of the heat. In total, 908 respondents participated in the telephone survey. Some of the key results indicate that knowledge of the heat warning was nearly universal (90%), and likely due to pervasive media coverage more than any other means. Though knowledge of the event was widespread, knowledge of what to do was less common. Only around half of all respondents mentioned that they changed their behavior, and despite the diversity of information available on mitigating heat vulnerability, most respondents stated that they merely "avoided the outdoors" at all costs. Though air conditioning was nearly ubiquitous among respondents, over a third mentioned that economic factors of energy costs were considered in terms of how long or whether the air conditioner was turned on.

Attitude↗

A comparative analysis of heat waves and associated mortality in St. Louis, Missouri--1980 and 1995.

This research investigates heat-related mortality during the 1980 and 1995 heat waves in St. Louis, Missouri. St. Louis has a long history of extreme summer weather, and heat-related mortality is a public health concern. Heat waves are defined as days with apparent temperatures exceeding 40.6 degrees C (105 degrees F). The study uses a multivariate analysis to investigate the relationship between mortality and heat wave intensity, duration, and timing within the summer season. The heat wave of 1980 was more severe and had higher associated mortality than that of 1995. To learn if changing population characteristics, in addition to weather conditions, contributed to this difference, changes in population vulnerability between 1980 and 1995 are evaluated under simulated heat wave conditions. The findings show that St. Louis remains at risk of heat wave mortality. In addition, there is evidence that vulnerability has increased despite increased air-conditioning penetration and public health interventions.

Aged↗

[Determination of epinephrine, chlorpromazine and promethazine by capillary electrophoresis with scanning voltammetric detector].

With a self-constructed electrochemical detection system, the determination of epinephrine, chlorpromazine and promethazine has been studied by using capillary electrophoresis with scanning voltammetric detector. Scanning potential generation and data acquisition were carried out with D/A and A/D converter board that mounted on a 486DX66 computer. A complex software, which was written by authors in BORLAND C++, was serve to data acquisition, abstraction of three-dimension data, display and print of the electrophorograms. Using a 25 microns x 70 cm fused-silica capillary, the optimum conditions for separation and detection of titled drugs are 10 mmol/L K2HPO4 + H3PO4 (pH 3.0) running electrolyte, 20 kV separation voltage, hydrodynamic injection 10 s at 20 cm height, scanning potential from +0.4 to +1.0 V vs. SCE. With the optimizing condition, the separation of titled drugs is satisfactory, and good reproducibility and low limit are obtained. In this study, all experiments are carried out under air-conditioning (18 degrees C) and constant humidity (relative humidity 50%). In comparison to amperometric detection, scanning voltammetric detection has the advantages of minimizing fouling of the working electrode surface, and direct identification of unknown chemicals by voltammetric curves.

Chlorpromazine↗

Deterioration of cycloserine in the tropics.

Gross deterioration of cycloserine during transit and storage in the tropics is reported from the Tuberculosis Chemotherapy Centre, Madras. Laboratory experiments suggest that high humidity, rather than high temperature, is the main cause of the deterioration. Further investigations undertaken at the Centre indicate that deterioration can be prevented by storing the drug in tightly closed glass bottles in an air-conditioned room (18 degrees C); if such facilities are not available, and the drug has to be stored at ambient temperature and humidity, the use of air-tight polyethylene bottles will serve to delay the deterioration. The findings also suggest that, when cycloserine is dispensed to patients, individual doses should be heat-sealed in polyethylene strips and that not more than a week's supply should be given at any one time. The authors discuss various measures that could be employed by manufacturers and by shipping and clearing agents to minimize the possibility of deterioration.

Cycloserine↗

Serum bromine levels in psoriasis.

Serum bromine levels in psoriatic Danes increased 2- to 3-fold during a 4-week bathing course in the Dead Sea. This increase correlated well with the improvement in their clinical and psychic condition. Serum bromine levels in psoriatic Danes were somewhat lower than those in healthy subjects residing in Denmark, but the difference was not significant. Israelis working in the open air in the Dead Sea area (air bromine 20-fold higher than in Jerusalem) had higher bromine levels than psoriatic or healthy Israelis residing in Jerusalem or healthy Israelis working in air-conditioned rooms in the Dead Sea area (p less than 0.05), but those levels were still within the normal range. As our animal experimentation indicates that the skin is a major target organ for 82Br, applied either by bathing or as an aerosol, we conclude that the higher bromine levels noticed in the psoriatic Danes after their 4-week stay at the Dead Sea may be equally due to their contact with the bromine-containing aerosol and the high bromine level of the Dead Sea waters.

Adult↗

Ozone's impact on public health: contributions from indoor exposures to ozone and products of ozone-initiated chemistry.

OBJECTIVE: The associations between ozone concentrations measured outdoors and both morbidity and mortality may be partially due to indoor exposures to ozone and ozone-initiated oxidation products. In this article I examine the contributions of such indoor exposures to overall ozone-related health effects by extensive review of the literature as well as further analyses of published data. FINDINGS: Daily inhalation intakes of indoor ozone (micrograms per day) are estimated to be between 25 and 60% of total daily ozone intake. This is especially noteworthy in light of recent work indicating little, if any, threshold for ozone's impact on mortality. Additionally, the present study estimates that average daily indoor intakes of ozone oxidation products are roughly one-third to twice the indoor inhalation intake of ozone alone. Some of these oxidation products are known or suspected to adversely affect human health (e.g., formaldehyde, acrolein, hydroperoxides, fine and ultrafine particles). Indirect evidence supports connections between morbidity/mortality and exposures to indoor ozone and its oxidation products. For example, cities with stronger associations between outdoor ozone and mortality tend to have residences that are older and less likely to have central air conditioning, which implies greater transport of ozone from outdoors to indoors. CONCLUSIONS: Indoor exposures to ozone and its oxidation products can be reduced by filtering ozone from ventilation air and limiting the indoor use of products and materials whose emissions react with ozone. Such steps might be especially valuable in schools, hospitals, and childcare centers in regions that routinely experience elevated outdoor ozone concentrations.

Air Pollution, Indoor↗

The protective effect of a cold weather mask on exercised-induced asthma.

The authors investigated the usefulness of a cold weather mask in reducing exercise-induced bronchospasm. Ten asthmatic subjects were selected because of previously demonstrated exercise-induced bronchospasm. Airway responses to submaximal exercise were measured on four separate days. Exercise was performed on the first two days at ambient temperature in a centrally air-conditioned laboratory and on the second two days in a refrigerated room. Exercise challenge was similar on each of the two days of the separate environmental conditions, with the exception that a mask was worn on one of the two days. Pulmonary function was measured using maximal and partial expiratory flow volume curves before and after exercise. On both of the days during which subjects exercised without a mask, significant decreases in all pulmonary function parameters occurred. Protection was seen under both conditions, but was more complete in the cold. These studies demonstrate the therapeutic potential of cold weather masks in protecting asthmatics against the effects of exercise and cold air.

Adolescent↗

Indoor environments and health: moving into the 21st century.

The quality of our indoor environments affects well-being and productivity, and risks for diverse diseases are increased by indoor air pollutants, surface contamination with toxins and microbes, and contact among people at home, at work, in transportation, and in many other public and private places. We offer an overview of nearly a century of research directed at understanding indoor environments and health, consider current research needs, and set out policy matters that need to be addressed if we are to have the healthiest possible built environments. The policy context for built environments extends beyond health considerations to include energy use for air-conditioning, selection of materials for sustainability, and design for safety, security, and productivity.

Air Pollution, Indoor↗

[Reaction of the external respiration system to a hypercapnic stimulus in rabbits under increased pressure].

In 10 unanesthetized rabbits exposed to normoxic (PIO2 = 0.2 kgs/cm2) helio-oxygen medium under pressure 40 kgs/cm2, changes of the respiration parameters (frequency, Vt, V, ITP) depending on the CO2 tension in the blood were studied with the aid of the recurrent respiration technique. The animals both in hyperbaric and in normal conditions (air), when breathing from the sack up to 7 min, revealed a linear increase in V due to an increase of the CO2 tension in the blood, but the lung ventilation increment decreased by the 12th min. In the helio-oxygen mixture under hyperbaric conditions the V relative increment was lesser and its decrease by the 12th min was more obvious than in ordinary air under the atmospheric pressure.

Animals↗

Standards for moderate thermal environments.

Recently two Draft International Standards dealing with specifications of the conditions for thermal comfort (ISO DIS 7730) and measurement procedures (ISO DIS 7726) have been approved by the International Stadardisation Organisation (ISO). The American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) has made a standard with similar requirements for the thermal environment (ASHRAE, 1981). To verify the requirements, measurements of different thermal parameters have to be performed. Guidelines as to how and where to measure are also given in the standards. The present paper deals mainly with the requirements and measurements that are relevant for moderate thermal environments in places of residence, offices, hospitals and light industry. For evaluation of very hot or very cold surroundings, other methods are required. Only measurements of parameters that influence the perception of the thermal surroundings are included.

Journal Article↗

Radiation resistance of lactobacilli isolated from radurized meat relative to growth and environment.

Of 113 lactobacilli isolated from radurized (5 kGy) minced meat, 7 Lactobacillus sake strains, 1 L. curvatus strain, and 1 L. farciminis strain were used for radiation resistance studies in a semisynthetic substrate (i.e., modified MRS broth). Five reference Lactobacillus spp., one Staphylococcus aureus strain, and one Salmonella typhimurium strain were used for comparative purposes. All L. sake isolates exhibited the phenomenon of being more resistant to gamma-irradiation in the exponential (log) phase than in the stationary phase of their growth cycles by a factor of 28%. Four references strains also exhibited this phenomenon, with L. sake (DSM 20017) showing a 68% increase in resistance in the log phase over the stationary phase. This phenomenon was not common to all bacteria tested and is not common to all strains with high radiation resistance. Four L. sake isolates and three reference strains were used in radiation sensitivity testing in a natural food system (i.e., meat). The bacteria were irradiated in minced meat and packaged under four different conditions (air, vacuum, CO2, and N2). Organisms exhibited the highest death rate (lowest D10 values [doses required to reduce the logarithm of the bacterial population by 1] ) under CO2 packaging conditions, but resistance to irradiation was increased under N2. The D10 values of the isolates were generally greater than those of the reference strains. The D10 values were also higher (approximately two times) in meat than in semisynthetic growth medium.

Animals↗

Influence of crossdrafts on the performance of a biological safety cabinet.

A biological safety cabinet was tested to determine the effect of crossdrafts (such as those created by normal laboratory activity or ventilation) upon the ability of the cabinet to protect both experiments and investigators. A simple crossdraft, controllable from 50 to 200 feet per min (fpm; 15.24 to 60.96 m/min), was created across the face of the unit. Modifications of standardized procedures involving controlled bacterial aerosol challenges provided stringent test conditions. Results indicated that, as the crossflow velocities exceeded 100 fpm, the ability of the cabinet to protect either experiments or investigators decreased logarithmically with increasing crossdraft speed. Because 100 fpm is an airspeed easily achieved by some air conditioning and heating vents (open windows and doorways may create velocities far in excess of 200 fpm), the proper placement of a biological safety cabinet within the laboratory--away from such disruptive air currents--is essential to satisfactory cabinet performance.

Air Microbiology↗

A monitor for airborne bacteria.

A unique agar drum sampler is described which indicates, continuously, the number of viable, bacterial particles per unit volume of air at the time and point of sampling. By selection of the timer and the sampling rate the sampler is suitable for quite a wide range of concentration and time. An impaction line of 484 in. greatly increases the capacity of this device over slit samplers and other instruments designed to give time-concentration data for viable airborne particles. This sampler should prove useful for: (i) monitoring airborne bacteria in hospitals, public places, and food and industrial plants; (ii) decay rate studies of bacterial aerosols; (iii) evaluation of aerial germicides; (iv) determination of effectiveness of air conditioning systems in removing airborne bacteria; and (v) many other studies in aerobiology.

Aerosols↗

Evaluation of indoor air quality using the decibel concept. Part I--proposal of new units.

Weber-Fechner's law concerning the perception of sound by man with time expressed as a logarithmic function can also be used for the odour constituent used in the evaluation of indoor air quality in buildings. A new unit dB (odour) based on the concentration of Total Volatile Organic Compounds (TVOC) is proposed as it is currently the basis for determining the air change rate. On the Psycho-Physical Scale according to Yaglou, the weakest odour that can be detected by the human small sensors is equal to one and corresponds to the lower limit of percentage dissatisfaction (PD) of 5.8% and a threshold concentration (TVOC) of 50 micrograms/m3-0 dB (odour). The upper limit is determined by the initial value of toxicity TVOC-25,000 micrograms/m3-135 dB (odour). Optimal values corresponding to PD = 20% (according to EUR 14449 EN) and admissible values corresponding to PD = 30% (see Table 3) are proposed, therefore the same values used to evaluate noise can be used to evaluate air quality and additionally the contribution of individual constituents (at present acoustic and odour) to the overall quality of the environment can be ascertained. The determination of the required volume of fresh air for ventilation and air-conditioning systems according to the new principles is the subject of the Part II of this paper.

Acoustics↗