Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Reagent Strips”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52Linked to original sources

Rapid detection of beta-lactamase by PADAC test strip.

A total of 967 isolates of Gram-positive and Gram-negative bacteria were tested for the production of beta-lactamase by the PADAC test strip, and the results were compared with acidometric, disk diffusion and antibiotic dilution procedures. All the penicillinase producting strains of gonococci (23) and Haemophilus influenzae (36) gave positive results with PADAC, but the 361 isolates of Staphylococcus aureus and S. epidermidis remained negative. All of the 547 strains of penicillin sensitive strains of gonococci, Haemophilus and staphylococci were negative with PADAC test.

Cephalosporins↗

Tear lysozyme activity in frozen Schirmer strips and salivary gland biopsy as parameters of lacrimal gland function.

PURPOSE: The lysozyme concentration in human tears is an important parameter for tear gland function. The decline of lysozyme in tears reflects lacrimal gland destruction. In Sjögren's patients, lacrimal gland destruction parallels labial salivary gland destruction. The objective of this study was to determine whether human tear lysozyme that was frozen on Schirmer strips at -20 degrees C for several years maintained activity and whether there was a linear relation with inflammatory changes in labial salivary glands. METHODS: A total of 200 frozen Schirmer strips were processed. They were collected from 20 randomly selected patients each year of five consecutive years, all attending the UCSF Sjögren's Clinic. The tear lysozyme in the Schirmer strips was measured by a colorimetric assay. The average lysozyme concentration each year was calculated and compared. One third of the patients underwent labial salivary gland biopsy. The correlation was calculated between the tear lysozyme concentration and the lymphocytic focus scores in biopsy specimens. RESULTS: No significant difference of average lysozyme concentration in the Schirmer strips was found when the five different years of collection were compared. The linear relation between the tear lysozyme concentrations and the focus score in labial salivary gland biopsies showed a coefficient of r = -0.41. The linear relation between other diagnostic measurements, like Schirmer test, tear breakup time, or rose bengal staining pattern, and the focus score was lower. CONCLUSIONS: Human tear lysozyme in Schirmer strips can be stored at -20 degrees C for at least five years. There is little difference in lysozyme activity of frozen compared to unfrozen specimens. The lysozyme concentration in tears correlates better with the lymphocytic focus score in labial salivary gland biopsy than does clinical assessment and is therefore a parameter for the actual degree of tear gland destruction.

Biopsy↗

Selection of sputum specimens for microbiological examination.

The purpose of this study was to compare the leucocyte esterase (LE) strip test with direct microscopy of Gram-stained sputum smears for the demonstration of leucocytes (WBC) and to develop a simple method for selecting specimens suitable for cultural examination. A total of 11% of specimens were demonstrated to be unsuitable for bacteriological examination using the proposed algorithm. It is thought that this technique offers a simple alternative to traditional microscopy alone for screening sputum specimens.

Algorithms↗

Preliminary evaluation of an immunochromatographic strip test for specific Treponema pallidum antibodies.

We evaluated a prototype immunochromatographic strip (ICS) test for qualitative detection of Treponema pallidum antibodies in 353 sera from 157 patients. For sera from 43 syphilis patients, the ICSs were reactive, while for sera from 114 patients without syphilis, including 22 with biologically false-positive Rapid Plasma Reagin test results, the ICSs were nonreactive. The ICS test may expand the available options for serological testing for syphilis.

Antibodies, Bacterial↗

Immunochromatographic strip-based detection of Entamoeba histolytica-E. dispar and Giardia lamblia coproantigen.

BIOSITE Triage was 68.3% sensitive and 100% specific for the detection of Entamoeba histolytica-E. dispar (n = 71) compared to Alexon-Trend's ProSpecT test (reference standard) using fresh-frozen stool. Neither test is able to distinguish E. histolytica from E. dispar. Triage was 83.3% sensitive and 100% specific compared to microscopy (formalin-ether concentrates and permanent stains) for the detection of Giardia lamblia.

Animals↗

Screening urine before microscopy, by automated test-strip preselection: clinical evaluation of the improved Rapimat II/T (Behring).

In many laboratories, microscopy of urines is restricted to specimens selected on the basis of positive tests, mainly for protein, blood, nitrite, and leukocyte esterase. Here, we analyzed several hundred specimens by use of multiple dipsticks, read in an improved reflectometer. By comparing the results with quantitative microscopy, it could be shown that this system allows selection, with acceptable sensitivity and specificity, of those specimens that are likely to contain clinically important microscopic elements.

Autoanalysis↗

Diagnosing visceral leishmaniasis with the recombinant K39 strip test: experience from the Sudan.

We compared a strip test employing recombinant K39 (rK39) antigen and protein A/colloidal gold as read-out agents with the rK39 ELISA for IgM and IgG antibodies and the direct agglutination test (DAT) using 55 sera from patients with parasitologically confirmed visceral leishmaniasis (VL). The rK39 strip test was positive in 37/55 (67%), the DAT in 50/55 (91%) at > or = 1 : 1600 cut-off value and in 47/55 (85%) at > or = 1 : 6400 cut-off value. The rK39-ELISA gave positive IgG results for all sera; those who had a positive strip test had significantly higher IgG levels than those with a negative strip test (31.1 (SD=3.6) and 17.7 U/ml (SD=9.8), respectively, P < 0.0001). A total of 31/55 (56%) sera showed a positive IgM result; of these 27 (49%) had a positive strip test. We tested 115 apparently cured VL patients with the strip test during follow-up; 68 were also tested with DAT. In the strip test, 25-43% of patients had a positive result at time points 3, 6, 9 and 12 months after treatment; for DAT (cut-off > or = 1 : 1600) these results were 67-83%. In neither test did a significant decrease in positivity rates occur over time (P=0.37 for the strip test, P=0.17 for the DAT). No correlation (P=0.33) was found between a positive strip test and a positive DAT result (cut-off > or = 1: 1600), indicating that the strip test and DAT are complementary rather than interchangeable. Of 61 endemic controls two (3%) had a positive strip test result; both had a positive leishmanin skin test. The rK39 strip test has the ideal format for use in the field, but its sensitivity is limited; like DAT, but to a lesser extent, it remains positive after treatment.

Adolescent↗

[Clinical testing of a new blood glucose measuring system. A cooperative study at 8 centers].

The glucometer II system is a small measurement device with built-in batch-specific pressbutton calibration. The corresponding test strip "Glucostix" uses a two-color system. The blood glucose test strip can be evaluated both visually and by instrument. The precision determined in series was between 2.0% and 6.7% using control sera. The day-to-day precision was between 1.5% and 7.9%. Comparison of the methods on the basis of 781 and 109 capillary blood samples respectively revealed a good agreement between the hexokinase method or the glucose oxidase method (Beckman analyser) and the glucometer II values. The precision of measurement by the system was comparable in the two test strip batches employed. Visual reading of the test strips revealed a good agreement with the laboratory method in the hypoglycemic and normoglycemic range; at higher concentrations of blood glucose, a trend to underestimation of the measurement values was shown. The easy handling and small size of the instrument facilitates measurement of blood glucose by the patient under everyday conditions.

Blood Glucose↗

The effect of oral care feed-back devices on plaque removal and attitudes towards oral care.

OBJECTIVES: Two studies were carried out to investigate whether the effect of specific oral care feed-back devices would result in better plaque removal (Study 1) and lead to changes in attitudes and views relating to oral health (Study 2). The objective of the first study was to compare the ability of a toothbrush system consisting of a new toothbrush plus plaque disclosing tablet (SIGNAL Integral) to remove supra-gingival plaque to that of a marketed toothbrush (Oral B Cross Action) following a single unsupervised brushing. METHODS: Study 1 had a cross-over design and included 21 healthy adult volunteers. Subjects refrained from any form of oral hygiene for 24 hours prior to each test session. Plaque levels (Modified Quigley-Hein Plaque index) were assessed prior to and following each unsupervised brushing. When the new toothbrush was used, subjects self-disclosed their plaque with a disclosing tablet (erythrosine) immediately prior to brushing. At each occasion, brushing time (in sec) was also recorded. Study 2 had a two-cell, parallel design (test and control group) and lasted for five days. Healthy adult volunteers were enrolled. Subjects in the test group (n = 30) were given a fluoride toothpaste and four saliva test strips to use at home. The saliva test strip is designed to change colour in the pH range of 6.5 to 10, allowing the user to verify the effect of brushing. The control group (n = 29) received no saliva test strips. Subjects completed a questionnaire after 4 days of product use. RESULTS: In Study 1, significantly more plaque was removed (p < 0.05) and brushing time was increased by more than 20% when subjects used the new toothbrush together with the disclosing tablet compared to brushing with the marketed toothbrush. In Study 2, significant increases in motivation relating to oral hygiene were found in the test group who had been using the saliva test strip. CONCLUSION: The two studies have provided significant evidence that the provision of feed-back devices in an oral care context can lead to improved removal of plaque and increased motivation.

Adult↗

A new, rapid, noninvasive screening test for celiac disease.

Serum levels of IgA and IgG antigliadin antibodies were evaluated in 267 subjects by using both the classic enzyme-linked immunosorbent assay and a rapid test (strip-AGA test) performed on a drop of whole blood. This new test was easy to perform and gave results comparable to those of the enzyme-linked immunosorbent assay; it could be useful in screening for celiac disease in both at-risk and normal populations.

Adolescent↗

[A new rapid test for diagnosing micro-haematuria, compared with results of microscopic examination].

Micro-haematuria may be difficult to diagnose because the usual sediment methods may be inadequate and test strips may in practice not be sensitive enough. The demarcation between normal and pathological RBC excretion is, therefore, not always clearly established. A new test strip (Sangur-Test) has its lower limit of positive results at 1 000 RBC/ml urine and physiological ranges of RBC excretion could be distinguished from micro-haematuria with satisfactory accuracy. Comparative tests of 637 freshly voided urine specimens in routine diagnosis produced no false-negative results and in only a small percentage of cases recorded a higher RBC concentration than the ten-field sediment method.

Blood Sedimentation↗

Screening urine with a leukocyte esterase strip and subsequent chlamydial testing of asymptomatic men attending primary care practitioners.

BACKGROUND AND OBJECTIVES: The detection of asymptomatic urethritis using a leukocyte esterase (LE) strip may have a role in primary care screening to select men who need diagnostic testing for Chlamydia trachomatis and Neisseria gonorrhoeae. STUDY DESIGN: Eight-hundred and eighty-two men, 16 to 35 years of age were studied when they attended their family physician or university health clinic for nongenitourinary complaints. First void urine (FVU) was tested by an LE strip (Chemstrip 2 LN, Boehringer Mannheim Corp., Indianapolis, IN), Chlamydiazyme (Abbott Laboratories, N. Chicago, IL) enzyme immunoassay with confirmatory blocking and polymerase chain reaction (PCR) with chlamydial plasmid primers. RESULTS: Forty-five men (5.1%) were positive (> trace) by LE strip. Of the LE-positive urines, 9 (20.0%) were positive by EIA or PCR, and none of the LE-negatives were positive by EIA or PCR. Twenty-three LE positives (5 EIA/PCR-positive; 1 PCR-positive; 17 EIA/PCR-negative) were able to be followed with a second urine and 2 urethral swabs. All of the 6 chlamydia-positives who had follow-up tests were positive by both immunoassay and PCR on urine. Based on the FVU results, the prevalence of asymptomatic chlamydial infection was 1.0% (9/88) (95% CL, 0.5 to 1.9) for which the LE urine strip was 100% (9/9) sensitive and 95.9% (837/873) specific. Analyses based on screening 1,000 men, 16 to 25 years of age, showed that the cost per case detected was $192.00 using the LE strip (> 1+) to select urine specimens for EIA testing, compared to $1,326.00 using the EIA to test all urine specimens. CONCLUSION: In this low prevalence, primary care setting, the LE urine strip was an accurate screening test, which if used to preselect urine specimens for subsequent chlamydial testing, would be less costly per case detected than assaying each specimen for chlamydia.

Adolescent↗

Evaluation of genotype and LiPA MYCOBACTERIA assays for identification of Finnish mycobacterial isolates.

Two DNA strip assays, INNO-LiPA MYCOBACTERIA and GenoType Mykobakterien, were evaluated for identification of 81 Finnish mycobacterial isolates. The LiPA assay correctly identified 89.4% of the 66 isolates studied, and the GenoType assay identified 95.1% of 81 isolates. The GenoType assay had a wider selection of species and less stringent temperature requirements.

Bacterial Typing Techniques↗

A spoonful of sugar--improving the sensitivity of the glucose oxidase test strip method for detecting subclinical pulmonary aspiration of enteral feed.

A 74-year-old woman was admitted to the intensive care unit (ICU) with respiratory failure. Following intubation and mechanical ventilation, nasogastric enteral feeding was begun. The sensitivity of the glucose oxidase strip method for detecting aspiration of enteral feed has been questioned because the glucose levels in commonly used feeds are similar to those of normal tracheal aspirates. In order to increase the glucose concentration of the feed, 10 g of glucose was added to each 500 ml feed carton. Testing oral and tracheal secretions with standard glucose oxidase strips allowed the accurate detection of both pharyngeal regurgitation and tracheal aspiration. An episode of subclinical aspiration was detected and this was associated with a fall in the PaO2/FiO2 ratio. There were no further episodes of aspiration following the introduction of a gastric motility agent, maintaining the patient in the semi-recumbent position and an increase in the positive end expiratory pressure (PEEP).

Aged↗

An improved method for detecting mutans streptococci using a commercial kit.

The improved detection of mutans streptococci (MS) in individuals was investigated using several modifications to a commercially available kit, Dentocult SM. Significantly better detection of MS was achieved using plaque from the four approximal surfaces at two interdental spaces than with saliva (P < 0.001). Furthermore, the MS estimates for approximal surfaces at the same interdental space were similar (kappa = 0.654) suggesting that differentiating the two surfaces does not improve the detection of MS, and that increasing the number of interdental spaces sampled is a more effective option. This study also evaluated a modification to the standard Dentocult SM site strip method in which two strips were incubated per broth vial so that plaque from eight interdental spaces could be tested at the same time (new method). The results were compared to those obtained when one strip was incubated per broth vial (standard method). Although the MS estimates by the new and standard methods were comparable (kappa = 0.721), the efficiency of MS detection was improved significantly by increasing the number of sites used for MS estimates (P = 0.01). In conclusion, MS detection at eight interdental spaces is recommended using the new Dentocult SM method.

Adult↗

Kinetic analysis of technetium-99m d,1-HM-PAO decomposition in aqueous media.

Technetium-99m-d,1-hexamethylpropyleneamine oxime [99mTc]d,1-HM-PAO) is a neutral-lipophilic chelate formed from a kit in high yield by stannous reduction of Na99mTcO4-. Of three methods used to analyze the purity of the 99mTc complexes, a single strip method using ether as the developing solvent was the most rapid and simple to perform. The lipophilic chelate converts to 99mTcO4- and other hydrophilic products with time and this limits the useful lifetime of the preparations. The rate of decomposition of [99mTc]d,1-HM-PAO increased in the presence of excess stannous ion and at pH greater than 9.

Chromatography, High Pressure Liquid↗

[Cytur-test used in nephrology out-patients (author's transl)].

Assessment of the value of test strips for demonstration of white cells in urine (Cytur-test) in 161 out-patient urine samples showed that a quick method such as the Cytur-test is no substitute for conventional methods. In hospital nephrology out-patients methods such as the Addis count or the investigation of urine sediment cannot be replaced. However, in a preliminary test with test strips information can be obtained as to the white cell content of the urine. Samples from patients in whom Addis count or sediment results showed no pathological leucocyturia, also had negative results in the test strip in a high percentage (84 out of 88 cases). A positive Cytur-test indicates lysed white cells in such cases (4 out of 88 cases). Due to the different sensitivity, as a consequence of a wider negative range, the Cytur-test resulted in fewer positive findings when compared to the other methods: 6 out of 24 in the Addis count and 2 out of 11 in urinary sediment.

Ambulatory Care↗