Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyethylene”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52Linked to original sources

The acetabular insert-metal backing interface: an additional source of polyethylene wear debris.

In cementless acetabular arthroplasty, the interface between the metal backing and the ultra-high-molecular-weight polyethylene acetabular insert surface is a potential source of polyethylene debris. This study of 55 early-generation acetabular inserts found that severe wear of the convex insert surface correlates with osteolysis. Wear of the concave insert surface did not correlate strongly with osteolysis probably owing to prevalent micromotion and wear at the convex surface interface. Although concern over linear wear predominates with contemporary designs, if initial liner engagement is compromised or locking mechanism failure occurs with time, the convex insert surface again may become a significant source of debris contributing to osteolysis.

Acetabulum↗

Cracking and impingement in ultra-high-molecular-weight polyethylene acetabular liners.

The purpose of this study was to determine the prevalence of crack formation in conventional ultra-high-molecular-weight polyethylene cups and its association with rim impingement, oxidation, and time in situ. One hundred twenty acetabular cups were retrieved during revision total hip arthroplasty. In 40% (48/120) of the retrieved specimens, multiple subsurface cracks of several millimeters in length were revealed by transillumination. In 5 specimens, full thickness cracks led to fragmentation of the liner before revision. Thirty-eight (32%) liners had regions of moderate to severe impingement damage to the rim; cracks were initiated at the site of impingement in all but 1 liner (P < .0001). Cracks commonly occur in conventional ultra-high-molecular-weight polyethylene liners, often after neck impingement and almost always in association with oxidation of the polymer.

Acetabulum↗

Relationship between product demand, tibial polyethylene insert shelf age, and total knee arthroplasty survival: retrospective review of total knees of one design.

Shelf aging of gamma-irradiated-in-air polyethylene tibial components has been associated with increased articular surface wear and an elevated risk for revision. Nine hundred fifty cruciate-retaining inserts of one design were implanted between 1987 and 1996 (shelf age, 1.0 +/- 1.2 years). Less frequently used inserts (smallest/largest sizes, thicker thicknesses, supplemental articular constraint) had longer shelf ages (means ranged from 1.2 to 2.6 years). Survival analysis showed that shelf age (P < .01) and gamma-sterilization in air (P = .01) elevated the risk for revision. Surgeons must remain attentive to identify the shelf-aged gamma-irradiated-in-air polyethylene tibial component while following designs from the era when this sterilization method was used. Recognition is expedited by understanding how shelf life is related to product demand and can be of aid when diagnosing the painful knee.

Arthroplasty, Replacement, Knee↗

Midterm results of primary total knee arthroplasty using a dished polyethylene insert with a recessed or resected posterior cruciate ligament.

Use of a dished polyethylene insert in 114 total knee arthroplasties, all with the posterior cruciate ligament resected or recessed, was retrospectively studied. Patients were evaluated at a mean follow-up of 8.3 years. Mean range of motion increased from 92 degrees to 111 degrees . Mean Knee Society pain and function scores increased from 35.2 and 39.7 to 91.3 and 74.7, respectively. WOMAC scores improved significantly in each category evaluated, including pain, stiffness, and physical function. Kaplan-Meier survivorship was 95% at 10 years (95% confidence interval, 82%-99%). The use of a dished polyethylene insert in primary total knee arthroplasty provides good to excellent midterm results regardless of whether the posterior cruciate ligament is recessed or sacrificed.

Adult↗

Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up.

Steady-state penetration rates were determined on 53 total hip arthroplasties with a minimum 3-year follow-up using electron beam highly cross-linked melted polyethylene by determining the femoral head penetration occurring after the first year in vivo. These data were compared with that of a matched control group. The average steady-state penetration rate of the control group was 144 +/- 191 mum/y, significantly higher than that of the highly cross-linked polyethylene group, 25 +/- 99 microm/y (P = .0001). Linear regression analysis indicated that the magnitude of femoral head penetration did not increase with time in the cross-linked groups. Also, no significant difference existed between the steady-state wear rates of the highly cross-linked groups with two head sizes (28 vs 32 mm, P = .39).

Arthroplasty, Replacement, Hip↗

A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners.

Cross-linked liners were introduced with the promise that they would substantially reduce polyethylene wear. In 1999, our institution initiated a prospective study to compare the outcome of total hip arthroplasty patients who were randomized to non-cross-linked Enduron liners with that of total hip arthroplasty patients who were randomized to Marathon polyethylene liners that had been cross-linked with 5 Mrad (50 kGy) of gamma-irradiation and heat-treated to eliminate free radicals. At a mean follow-up of 5.7 years, the clinical outcomes among the Marathon and Enduron liners were similar. However, the mean wear rate was 0.01 +/- 0.07 mm/y for the Marathon group, which represents a 95% reduction compared with the mean wear rate of 0.19 +/- 0.12 mm/y for the Enduron group. In addition, the incidence of osteolysis was lower in the Marathon group.

Adult↗

Implementation of ALARA radiation protection on the ISS through polyethylene shielding augmentation of the Service Module Crew Quarters.

With 5-7 month long duration missions at 51.6 degrees inclination in Low Earth Orbit, the ionizing radiation levels to which International Space Station (ISS) crewmembers are exposed will be the highest planned occupational exposures in the world. Even with the expectation that regulatory dose limits will not be exceeded during a single tour of duty aboard the ISS, the "as low as reasonably achievable" (ALARA) precept requires that radiological risks be minimized when possible through a dose optimization process. Judicious placement of efficient shielding materials in locations where crewmembers sleep, rest, or work is an important means for implementing ALARA for spaceflight. Polyethylene (CnHn) is a relatively inexpensive, stable, and, with a low atomic number, an effective shielding material that has been certified for use aboard the ISS. Several designs for placement of slabs or walls of polyethylene have been evaluated for radiation exposure reduction in the Crew Quarters (CQ) of the Zvezda (Star) Service Module. Optimization of shield designs relies on accurate characterization of the expected primary and secondary particle environment and modeling of the predicted radiobiological responses of critical organs and tissues. Results of the studies shown herein indicate that 20% or more reduction in equivalent dose to the CQ occupant is achievable. These results suggest that shielding design and risk analysis are necessary measures for reducing long-term radiological risks to ISS inhabitants and for meeting legal ALARA requirements. Verification of shield concepts requires results from specific designs to be compared with onboard dosimetry.

Astronauts↗

Mechanical properties of glass-ceramic A-W-polyethylene composites: effect of filler content and particle size.

Composites which comprise a bioactive filler and ductile polymer matrix are desirable as implant materials since both their biological and mechanical properties can be tailored for a given application. In the present study three-point bending was used to characterise biomedical materials composed of glass-ceramic apatite-wollastonite (A-W) particulate reinforced polyethylene (PE) (denoted as AWPEX). The effects of filler volume fraction, varied from 10 to 50 vol%, and average particle size, 4.4 and 6.7 microm, on the bending strength, yield strength, mode of fracture, Young's modulus and strain to failure were investigated. HAPEX, a commercially used composite of hydroxyapatite and polyethylene, with a 40 vol% filler content, was used for comparison. Increasing the filler content caused an increase in Young's modulus, yield strength and bending strength, and a decreased strain to failure. When filler particle size was increased, the Young's modulus, yield and bending strengths were found to be slightly reduced. A transition in fracture behaviour from ductile to brittle behaviour was observed in samples containing between 30 and 40 vol% filler.

Apatites↗

Expression of inflammatory cytokines, RANKL and OPG induced by titanium, cobalt-chromium and polyethylene particles.

Bone resorption is regulated by cytokines such as tumor necrosis factor-alpha (TNF-alpha), interleukin-1 beta (IL-1beta) and by the balance of a receptor activator of nuclear factor-kappaB ligand (RANKL) and osteoprotegerin (OPG). The aim of this study was to investigate the mechanism of particle-induced osteolysis in murine calvariae by assessing the extent of osteolysis and the expression of inflammatory cytokines, RANKL and OPG after implantation of metal and polyethylene particles. The murine calvariae implanted with Ti6Al4V, CoCr or high-density polyethylene (HDP) particles showed significantly more extensive osteolysis and elevated levels of inflammatory cytokines. The ratio between RANKL and OPG was high in the mice implanted with Ti6Al4V and HDP particles, but not in the mice implanted with CoCr particles. These observations suggested that CoCr particle-induced osteoclastogenesis may be caused directly by inflammatory cytokines rather than by the RANKL-RANK pathway. There might be different mechanisms at work in particle-induced osteolysis between Ti6Al4V, HDP and CoCr.

Animals↗

Polyethylene glycol inhibits intestinal neoplasia and induces epithelial apoptosis in Apc(min) mice.

Efficacy of a safe and clinically utilized polyethylene glycol formulation (PEG-3350) to suppress intestinal tumors was investigated in the Apc(min) mouse-model of experimental carcinogenesis. Furthermore, based on our previous finding on the induction of apoptosis in HT-29 cells by PEG, we evaluated its ability to stimulate epithelial cell apoptosis in both Apc(min) mouse as well as AOM-treated rat as a potential molecular mechanism of chemoprevention. Twenty-two Apc(min) mice were randomized equally to PEG or vehicle (control) supplementation. Tumors were scored and uninvolved intestinal mucosal apoptosis was assayed using a modified terminal deoxynucleotidyl transferase-mediated nick end-labeling (TUNEL) assay and by immunohistochemical detection of cleaved caspase-3. Supplementation of Apc(min) mice with 10% PEG 3350 (in drinking water) resulted in a 48% (P<0.05) reduction in intestinal tumor burden and induced 2-3 fold increase in mucosal apoptosis. Dietary supplementation of polyethylene glycol (5%) also stimulated colonic mucosal apoptosis 4-5 fold in AOM-treated rats, the regimen that we previously reported to reduce tumor burden by 76% (P<0.05). In summary, we demonstrate, for the first time, that PEG does protect against Apc(min) mouse tumorigenesis. The correlation between pro-apoptotic actions and chemopreventive efficacy of PEG in these models strongly implicates induction of apoptosis as one of the impending mechanisms of chemoprevention.

Animals↗

Biodegradation of polyethylene films with prooxidant additives.

Prooxidant additives represent a promising solution to the problem of the environment contamination with polyethylene film litter. Prooxidants accelerate photo- and thermo-oxidation and consequent polymer chain cleavage rendering the product apparently more susceptible to biodegradation. The question not fully resolved remains the biodegradation itself, its mechanism and especially the factors influencing the time-frame in which it can occur. The presented review is aimed to provide comprehensible information for both microbiologists and polymer scientists, who need participate in the research leading to an understanding of the microorganism action on the oxidized polyethylene and to design of new materials.

Biodegradation, Environmental↗

Experimental design approach for the optimisation of pressurised fluid extraction of additives from polyethylene films.

A pressurised fluid extraction (PFE) and normal-phase-high performance liquid chromatography (NP-HPLC) method is proposed for the determination of additives in polyethylene films. The study of PFE variables was performed using a Plackett-Burman (PB) experimental design for screening and a central composite design (CCD) for optimising the main variables obtained from the Pareto charts. The studied variables were: temperature, time, cyclohexane (CHx) and tetrahydrofuran (THF) as modifiers, flush volume and extraction cycles, and an isopropanol:CHx (92.5:7.5) mixture twice at 105 degrees C for 15 min were the final conditions selected. The additives in the PFE extracts were separated by NP-HPLC using a silica column and a gradient n-hexane:dichloromethane:acetonitrile mobile phase. Additive solubility is higher in normal-phase solvents; thus, their separation can be carried out at room temperature. Finally, the method was applied to determine additives in several polyethylene films.

Polyethylene↗

On-column refolding of consensus interferon at high concentration with guanidine-hydrochloride and polyethylene glycol gradients.

Dilution refolding of consensus interferon (C-IFN) had a limit on final concentration not exceeding 0.1 mg ml(-1) in order to achieve specific activity of 2.2x10(8) U mg(-1). Addition of polyethylene glycol (PEG) only gave a marginal improvement on the specific activity. Hydrophobic interaction chromatography (HIC) was tried but a simple step-wise elution could not refold the protein. Successful refolding was achieved by gradient elution with the decreasing of guanidine-hydrochloride (guanidine-HCl) concentration. The column was packed with a commercially available HIC medium that was designed for protein separation. Polyethylene glycol was found to possess better effect on the column than in the dilution for promotion of correct refolding, especially in gradient mode. A novel dual-gradient strategy, consisting of decreasing guanidine-HCl concentration and increasing PEG concentration, was developed to enhance the refolding yield. Denatured C-IFN was allowed to adsorb and elute from the HIC column through a gradually changed solution environment. Compared with dilution refolding, the gradient HIC process, in the presence of PEG, gave about 2.6-folds of increase in specific activity, 30% increase in soluble protein recovery. Partial purification was also achieved simultaneously.

Chromatography, Liquid↗

Retention in gas-liquid chromatography with a polyethylene oxide stationary phase: molecular simulation and experiment.

Configurational-bias Monte Carlo simulations in the isobaric-isothermal Gibbs ensemble were carried out to investigate the partitioning of normal alkanes, primary and secondary alcohols, symmetric alkyl ethers and arenes between a helium vapor phase and a polyethylene oxide stationary phase (M(W)=382 g mol(-1)). The united-atom version of the transferable potentials for phase equilibria force field was used to model all solutes, polyethylene oxide and helium. The Gibbs free energies of transfer and Kovats retention indices of the solutes were calculated directly from the partition constants at two different temperatures, 353 and 393 K. Chromatographic experiments on a Carbowax 20M retentive phase were performed for the same set of solutes and temperatures ranging from 333 to 413 K. The predicted retention indices for alcohols, ethers and arenes are overestimated by about 120, 70 and 20 retention index units, respectively, pointing to an overestimation of the first-order electrostatic interactions in the model system. Molecular-level analysis shows that hydrogen-bonding and dipole-dipole interactions lead to orientational ordering for the alcohol and ether analytes, whereas the weaker dipole-quadrupole interactions for the arene solutes are not sufficient to induce orientational ordering. The retention indices of alcohols and ethers decrease with increasing temperature because of the large entropic cost of hydrogen-bonding and orientational ordering. In contrast, the retention indices for arenes increase with increasing temperature because the entropic cost of cavity formation is smaller for arenes than for comparable alkanes.

Alcohols↗

Separation of polyethylene glycols and their fluorescein-labeled compounds depending on the hydrophobic interaction by high-performance liquid chromatography.

The separation and characterization of fluorescein-labeled polyethylene glycols (PEG) is described. Firstly, the polyethylene glycols labeled with fluorescein isothiocyanate (FITC) were synthesized and separated using Sephadextrade mark LH-20 medium by a step gradient. Secondly, a TSK GEL G4000 PW XL column was developed for determining the FITC derivatives of PEG. The retention mechanism is based on the hydrophobic interaction between the FITC derivatives of PEG and the packing material of the TSK GEL G4000PW XL column. The retention time of the PEG compounds increased by adding of salts in the mobile phase and decreased by adding of organic modifier. In addition, various salts in the eluent can also change the chromatographic behavior of these compounds. Finally, the pH of the mobile phase can have an impact on the retention time of the PEG compounds.

Chromatography, High Pressure Liquid↗

Comparison of three gas chromatography methods for the determination of slip agents in polyethylene films.

Polymers require the use of some slip agents, such as oleamide and erucamide, in order to reduce their friction coefficient and to make films easier to handle. In this communication, three analytical methods consisting in pressurized liquid extraction (PLE) and gas chromatography (GC) are used to determine oleamide and erucamide in polyethylene films. The sample was extracted with pure isopropanol (two times) at 105 degrees C for 16 min. Then, the liquid extract containing oleamide and erucamide was analyzed by GC and three different detection systems: flame ionization detector (FID), thermoionic selective detector (TSD) and ion-trap mass spectrometry detector (MSD). Oleamide and erucamide were separated using a 30 m x 0.25 mm (I.D.) 5% phenyl-95% dimethyl-polysiloxane capillary column in 12 min. The chromatographic methods were characterized and compared in terms of repeatability, linearity and sensitivity. The GC-FID and GC-TSD methods were linear up to about 60 microg ml(-1), whereas the linear range for the GC-MSD method was shorter, from 20.5 to 42 microg ml(-1). LODs identified with GC-MSD were two times higher than those identified with the other two methods. Repeatability values (expressed as relative standard deviation) of less than 2.5% were found for FID and TSD but they were above 10% for MSD. Finally, each method was applied to determine the content of erucamide and oleamide in several polyethylene films and the results obtained were compared with those obtained from the nitrogen content measured by pyrolysis and gas-phase chemiluminescence. No significant differences were observed between the results of the methods.

Chromatography, Gas↗

Factors governing the in vivo tissue uptake of transferrin-coupled polyethylene glycol liposomes in vivo.

Liposomes, coated with transferrin (Tf)-coupled polyethylene glycol are considered to be potent carriers for drug delivery to various organs via receptor-mediated endocytosis. Since Tf receptors were ubiquitously expressed in various organs, additional perturbation of the liposomes such as regulation of the size may be required to exhibit the tissue selectivity. In the present study, the effect of size on the uptake of transferrin-coupled polyethylene glycol liposomes (Tf-PEG-L) to various organs was investigated. In liver and brain, Tf-dependent uptake was found to be dependent on the size of the liposomes used. In small liposomes with a diameter of 60-80 nm, Tf-PEG-L was taken up to these organs more efficiently than PEG-L. This Tf-dependent uptake for small liposomes decreased by the high dose administration, suggested that Tf-PEG-L is taken up via Tf receptor-mediated endocytosis even under the physiological condition, in which plasma concentration of endogenous Tf remains high. On the other hand, Tf receptor-mediated uptake was also observed in the heart, but size-dependency was not observed in this case. Collectively, these results indicate that size dependency in the uptake of Tf-PEG-L is tissue-dependent and therefore, controlling the size of Tf-PEG-L may be useful for the success of tissue targeting.

Animals↗

A flow injection analysis/mass spectrometry method for the quantification of polyethylene glycol 300 in drug formulations.

A direct flow injection analysis/mass spectrometry (FIA/MS) method was developed for the quantification of polyethylene glycol. The method was used for the evaluation of distribution uniformity and mixing homogeneity of polyethylene glycol 300 (PEG 300) as a component in drug formulation mixtures. In the method, five of the most intense ions of the PEG 300 oligomer were chosen for selected ion monitoring (SIM) by mass spectrometry. Standard calibration curves were established, using either single channel SIM or the summed intensity of all five SIM channels plotting against the standard concentrations. Both calibration approaches produced comparable results on quantification. The feasibility of the method was demonstrated using both atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The method provided fast and sensitive quantification of PEG 300 without tedious chromatographic separation or sample preparation. The method has been successfully adopted for the evaluation of the mixing process in drug formulations.

Calibration↗