Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Multiplex”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52Linked to original sources

Detection of genetically modified maize MON810 and NK603 by multiplex and real-time polymerase chain reaction methods.

In this study, the event-specific primers for insecticide-resistant maize, MON810, and herbicide-tolerance maize, NK603, have been designed. Simplex PCR and multiplex PCR detection method have been developed. The detection limit of the multiplex PCR is 0.5% for MON810 and NK603 in 50 ng of the template for one reaction. Quantitative methods based on real-time quantitative PCR were developed for MON810 and NK603. Plasmid pMulM2 as reference molecules for the detection of MON810 and NK603 was constructed. Quantification range was from 0.5 to 100% in 100 ng of the DNA template for one reaction. The precision of real-time Q-PCR detection methods, expressed as coefficient of variation for MON810 and NK603 varied from 1.97 to 8.01% and from 3.45 to 10.94%, respectively. The range agreed with European interlaboratories test results (25%). According to the results, the methods for quantitative detection of genetically modified maize were acceptable.

DNA, Plant↗

Development of a multiplex polymerase chain reaction method for simultaneous detection of eight events of genetically modified maize.

In this study, we developed a novel multiplex polymerase chain reaction (PCR) method for simultaneous detection of up to eight events of genetically modified (GM) maize within a single reaction. The eight detection primer pairs designed to be construct specific for eight respective GM events (i.e., Bt11, Event176, GA21, MON810, MON863, NK603, T25, and TC1507) and a primer pair for an endogenous reference gene, ssIIb, were included in the nonaplex(9plex) PCR system, and its amplified products could be distinguished by agarose gel and capillary electrophoreses based on their different lengths. The optimal condition enabled us to reliably amplify two fragments corresponding to a construct specific sequence and a taxon specific ssIIb in each of the eight events of GM maize and all of nine fragments in a simulated GM mixture containing as little as 0.25% (w/w) each of eight events of GM maize. These results indicate that this multiplex PCR method could be an effective qualitative detection method for screening GM maize.

Base Sequence↗

Qdot nanobarcodes for multiplexed gene expression analysis.

We report a quantum dot (Qdot) nanobarcode-based microbead random array platform for accurate and reproducible gene expression profiling in a high-throughput and multiplexed format. Four different sizes of Qdots, with emissions at 525, 545, 565, and 585 nm are mixed with a polymer and coated onto the 8-mum-diameter magnetic microbeads to generate a nanobarcoded bead termed as QBeads. Twelve intensity levels for each of the four colors were used. Gene-specific oligonucleotide probes are conjugated to the surface of each spectrally nanobarcoded bead to create a multiplexed panel, and biotinylated cRNAs are generated from sample total RNA and hybridized to the gene probes on the microbeads. A fifth streptavidin Qdot (655 nm or infrared Qdot) binds to biotin on the cRNA, acting as a quantification reporter. Target identity was decoded based on spectral profile and intensity ratios of the four coding Qdots (525, 545, 565, and 585 nm). The intensity of the 655 nm Qdot reflects the level of biotinylated cRNA captured on the beads and provides the quantification for the corresponding target gene. The system shows a sensitivity of < or =10(4) target molecules detectable with T7 amplification, a level that is better than the 10(5) number achievable with a high-density microarray system, and approaching the 10(3)-10(4) level usually observed for quantitative PCR (qPCR). The QBead nanobarcode system has a dynamic range of 3.5 logs, better than the 2-3 logs observed on various microarray platforms. The hybridization reaction is performed in liquid phase and completed in 1-2 hours, at least 1 order of magnitude faster than microarray-based hybridizations. Detectable fold change is lower than 1.4-fold, showing high precision even at close to single copy per cell level. Reproducibility for this proof-of-concept study approaches that of Affymetrix GeneChip microarray, with an R(2) value between two repeats at 0.984, and interwell CV around 5%. In addition, it provides increased flexibility, convenience, and cost-effectiveness in comparison to conventional gene expression profiling methods.

Electronic Data Processing↗

Multiplexed two-dimensional liquid chromatography for MALDI and nanoelectrospray ionization mass spectrometry in proteomics.

We developed a multiplexed two-dimensional separation system based on reversed phase (RP)--strong cation exchange (SCX) chromatography as a front-end device for matrix-assisted laser desorption ionization (MALDI) or nanoelectrospray ionization (nanoESI) mass spectrometry. Tryptic peptide mixtures were fractionated on a reversed-phase HPLC column, and each fraction was loaded onto multiplexed SCX microcolumns. Because this second chromatography was carried out in parallel, the analysis time is independent of the fraction number in the first RP-HPLC separation. The resultant samples were desalted/concentrated and eluted onto a MALDI plate with matrix-containing elution solutions in parallel, or eluted with optimized solutions for nanoESI and loaded onto nanoESI sprayers by an automated instrument. The soluble portion of HCT116 lysate was digested and fractionated using a 48-plexed chromatography system. Approximately 1000 unique peaks were detected in MALDI-MS with 3000 MS/MS spectra, while 724 peptides with ultrahigh peptide mass accuracy (sub-ppm error) were identified in nanoESI-FTICR mass spectrometry with five integrated selected ion monitoring scans. Since MS measurement with this off-line LC-LC approach is not restricted by continuous LC elution, it is expected to be useful especially in cases where repeated analysis with different scan modes or long-term data acquisition is required.

Chromatography, Liquid↗

Multi-Q: a fully automated tool for multiplexed protein quantitation.

The iTRAQ labeling method combined with shotgun proteomic techniques represents a new dimension in multiplexed quantitation for relative protein expression measurement in different cell states. To expedite the analysis of vast amounts of spectral data, we present a fully automated software package, called Multi-Q, for multiplexed iTRAQ-based quantitation in protein profiling. Multi-Q is designed as a generic platform that can accommodate various input data formats from search engines and mass spectrometer manufacturers. To calculate peptide ratios, the software automatically processes iTRAQ's signature peaks, including peak detection, background subtraction, isotope correction, and normalization to remove systematic errors. Furthermore, Multi-Q allows users to define their own data-filtering thresholds based on semiempirical values or statistical models so that the computed results of fold changes in peptide ratios are statistically significant. This feature facilitates the use of Multi-Q with various instrument types with different dynamic ranges, which is an important aspect of iTRAQ analysis. The performance of Multi-Q is evaluated with a mixture of 10 standard proteins and human Jurkat T cells. The results are consistent with expected protein ratios and thus demonstrate the high accuracy, full automation, and high-throughput capability of Multi-Q as a large-scale quantitation proteomics tool. These features allow rapid interpretation of output from large proteomic datasets without the need for manual validation. Executable Multi-Q files are available on Windows platform at http://ms.iis.sinica.edu.tw/Multi-Q/.

Chromatography, Liquid↗

Multiplex RT-PCR method for the analysis of the expression of human sialyltransferases: application to breast cancer cells.

In many cases of human cancer, the appearance of hypersialylated glycan structures is related to a precise stage of the disease; this may depend on altered regulation of one or more sialyltransferases genes. Since several distinct sialyltransferase enzymes arising from different unique genes transfer sialic acid residues in the same linkage onto the same acceptor, it is impossible to precisely determine which enzyme is involved in the observed phenotype based on enzymatic assays. We have developed a very sensitive and highly reproducible multiplex reverse transcriptase-polymerase chain reaction technique in order to monitor the expression of four human sialyltransferases genes ST6Gal I, ST3Gal I, ST3Gal III and ST3Gal IV in small cell samples. Multiplex PCR amplification using specific primers for each sialyltransferase and detection of amplification products by polyacrylamide gel electrophoresis is a method that is fast and easy to handle and has proven to be useful for establishing sialyltransferase patterns of expression in breast immortalized cell line HBL100 as well as in breast cancer cell lines MCF-7/6, MCF-7/AZ and MDA.

Breast Neoplasms↗

Birth order effects on nonverbal IQ scores in autism multiplex families.

Lord (1992) published a brief report showing a trend for decreasing nonverbal IQ scores with increasing birth order in a sample of 16 autism multiplex families, and urged replication in a larger sample. In this report, analyses of nonverbal IQ scores for a sample of 144 autism multiplex families indicated that nonverbal IQ scores were significantly lower in secondborn compared with firstborn siblings with autism. This birth order effect was independent of gender as well as the age differences within sib pairs. No such birth order effects were found for social or communicative deficits as measured by the Autism Diagnostic Interview-Revised (ADI-R), but there was a modest tendency for increased scores for ritualistic behaviors for the firstborn sibs. Further, there were no gender differences on nonverbal IQ scores in this sample. Results are discussed in terms of implications for genetic studies of autism.

Autistic Disorder↗

Development of an emergency medical video multiplexing transport system. Aiming at the nation wide prehospital care on ambulance.

The Emergency Medical Video Multiplexing Transport System (EMTS) is designed to support prehospital cares by delivering high quality live video streams of patients in an ambulance to emergency doctors in a remote hospital via satellite communications. The important feature is that EMTS divides a patient's live video scene into four pieces and transports the four video streams on four separate network channels. By multiplexing four video streams, EMTS is able to transport high quality videos through low data transmission rate networks such as satellite communications and cellular phone networks. In order to transport live video streams constantly, EMTS adopts Real-time Transport Protocol/Real-time Control Protocol as a network protocol and video stream data are compressed by Moving Picture Experts Group 4 format. As EMTS combines four video streams with checking video frame numbers, it uses a refresh packet that initializes server's frame numbers to synchronize the four video streams.

Ambulances↗

Development of an Emergency Medical Video Multiplexing Transport System (EMTS): aiming at the nation-wide prehospital care in ambulance.

The Emergency Medical Video Multiplexing Transport System (EMTS) is designed to support prehospital care by delivering high quality patient's live video streams in an ambulance to emergency doctors in a remote hospital on the basis of satellite communications. The feature is that EMTS divides a patient's live video scene into four pieces and transports the four video streams on four separate network channels. By multiplexing the four video streams, EMTS is able to transport high quality videos through low data transmission rate networks such as satellite communications and cellular phone networks. In order to transport live video streams constantly, EMTS adopts Real-Time Transport Protocol/Real-Time Control Protocol as a network protocol, and video stream data are compressed by Moving Picture Experts Group 4 format. As EMTS combines four video streams with checking video frame numbers, it uses a refresh packet that initializes server's frame numbers to synchronize the four video streams.

Ambulances↗

Multiplexed sorting of libraries on libraries: a novel method for empirical protein design by affinity-driven phage enrichment on synthetic peptide arrays.

Chemically synthesized peptide arrays on planar cellulose carriers are proposed as libraries of ligands suitable for the multiplexed simultaneous capture of peptide-specific acceptor proteins from a large randomly mutagenized library of acceptor proteins presented on bacteriophage M13 particles. This experimental set-up can be exploited to rapidly screen for individual new, distinct binding partners from two complementary libraries (two-dimensional screening). The technical feasibility of this empirical protein design approach was demonstrated with calmodulin as an aceptor protein using an array of mastoparan variants for multiplexed phage affinity enrichment.

Amino Acid Sequence↗

A preliminary trial using multi-target polymerase chain reaction (multiplex PCR) and restriction fragment length polymorphism (PCR-RFLP) on the same feedstuffs to detect tissues of animal origin.

A preliminary study using multi-target polymerase chain reaction (multiplex PCR) and restriction fragment length polymorphism (PCR-RFLP) was done on the same feedstuffs to detect animal tissues. The results of the two methods differ somewhat: PCR-RFLP did not detect any signal in any sample, but multiplex PCR detected a signal in one sample. These findings could be a basis for further investigations.

Animal Feed↗

Detection of porcine circovirus type 2, porcine parvovirus and porcine pseudorabies virus from pigs with postweaning multisystemic wasting syndrome by multiplex PCR.

Multiplex PCR was established to detect porcine circovirus type 2 (PCV-2), porcine parvovirus (PPV) and porcine pseudorabies virus (PRV) and applied to samples from 137 piglets exhibiting clinical signs of postweaning multisystemic wasting syndrome (PMWS). PCV-2 DNA was detected from all samples. Moreover, 43 samples were positive for PPV but negative for PRV; 11 samples were positive for PRV but negative for PPV; and 35 samples were positive both for PPV and PRV. These results suggests that PCV-2 co-infection with PRV and PPV may play an important role in PMWS. Also, multiplex PCR is an appropriate candidate method for diagnosis of PCV-2, PRV and PPV simultaneously in field cases.

Animals↗

Mononeuritis multiplex caused by Coxiella burnetii infection (Q fever).

After 1 week of flu-like illness, a 64-year-old man developed rapidly progressive mononeuritis multiplex involving the right arm and both legs. Serologic studies identified Coxiella burnetii as the cause of the febrile disease (Q fever). Fourteen days doxycycline treatment (200 mg daily) induced rapid and complete recovery. After 6 months, flu-like symptoms, weakness and hypalgesia of the right leg reappeared. Antibody titers again identified Q fever. Doxycycline was re-established and induced prompt recovery. Q fever has been associated with various neurologic complications such as meningoencephalitis, cerebellitis, optic neuritis or polyneuroradiculitis. This is the first report on Q fever related mononeuritis multiplex. Prolonged antibiotic treatment may be required to prevent relapsing infection from the resistant bacterium.

Anti-Bacterial Agents↗

Detection of vancomycin resistance genes combined with typing of Enterococci by means of multiplex PCR amplification and multiple primer DNA sequencing.

A multiplex PCR assay for the detection of vancomycin resistance (van) genes in enterococci was established. Primers targeting the 16S rRNA gene were included in the reaction mixture. Multiple-primer DNA sequencing of the PCR products provided species identification through partial nucleotide sequences of 16S rRNA genes, as well as confirmation of the correct identification of vanA, vanB, vanC-1, and vanC-2/3 genotypes. Thirty-nine enterococcal clinical isolates and type strains were examined for the presence of vancomycin resistance determinants. Twelve other isolates from a clinical reference collection (some of them having vanA, vanB, vanC-1, or vanC-2/3 genotypes) were used as controls. Hybridization and partial DNA sequence analysis of multiplex PCR products revealed that none of the clinical isolates had a vanA genotype and only one had a vanB genotype. vanC-1 was found in three clinical isolates, and vanC-2/3 in one. Results obtained with the reference and type strains were in agreement with earlier results.

Bacterial Typing Techniques↗

A multiplex real-time PCR for quantification of HIV-1 DNA and the human albumin gene in CD4+ cells.

We have established a simple system for measuring HIV-1 DNA load in CD4+ cells. In a multiplex configuration, a conserved region in the HIV-1 pol gene and a section of the human albumin gene were simultaneously amplified to estimate the number of HIV-1 DNA copies per cellular genome. An established Epstein-Barr virus (EBV) standard system was used to calibrate the HIV-1 quantification. Our multiplex PCR system was tested on different in vitro developed HIV-1 strains and on longitudinal samples from eight patients. The system was able to amplify both in vitro and in vivo samples of various genetic compositions. In all eight patients, HIV-1 DNA was detected and ranged between 0.17 and 51x10-3 copies per CD4+ cell and could be monitored longitudinally, including long-term PI-ART and STI. The measured HIV-1 DNA load may be used to select the best time for the institution or re-institution of therapy.

Base Sequence↗

Frequency of allele loss of DCC, p53, RBI, WT1, NF1, NM23 and APC/MCC in colorectal cancer assayed by fluorescent multiplex polymerase chain reaction.

We report here the use of multiplex fluorescent polymerase chain reaction (PCR) for quantitative allele loss detection using microsatellites with 2-5 base pair repeat motifs. Allele loss of APC, DCC, p53 and RB1 in colorectal tumours has been reported previously using a variety of methods. However, not all workers used intragenic markers. We have used microsatellite polymorphisms which map within, or are closely linked to, these tumour-suppressor gene loci in order to determine whether these loci are indeed the targets for alteration in colorectal cancer. In addition, we have assayed two other tumour-suppressor genes, WT1 and NF1, to see whether they play a role in colorectal carcinogenesis. The putative metastasis-suppressor gene, NM23, was also investigated since there have been conflicting reports about its involvement in colorectal carcinogenesis. Allele loss was detected at the DCC (29%), p53 (66%), RB1 (50%) and NF1 (14%) loci and in the APC/MCC region (50%), but not at the WT1 or NM23 loci. These rapid, and mostly gene-specific, fluorescent multiplex PCR assays for allele loss detection could be modified to devise a single molecular diagnostic test for the important lesions in colorectal cancer.

Adenocarcinoma↗

A multiplex real-time pcr assay for the detection of gene fusions observed in solid tumors.

SUMMARY: Specific gene fusions observed in solid tumors are extremely useful diagnostic markers. We report the development of a method based on real-time PCR which enables the detection upon identical PCR conditions of the different fusions specifically observed in Ewing tumors (ET), alveolar rhabdomyosarcoma (ARMS), synovial sarcoma (SS), small round cell desmoplastic tumors (SRCDT), extraskeletal myxoid chondrosarcoma, malignant melanoma of soft parts, congenital fibrosarcoma, and anaplastic large cell lymphoma. A simple assay, based on multiplexing of primers and probes, is described for the routine genetic diagnosis of small round cell tumors of children. It enables the detection of the five EWS-ETS, the two PAX-FKHR, the three SYT-SSX, and the EWS-WT1 fusions of ET, ARMS, SS, and SRCDT, respectively. The sensitivity of this test is high enough to detect all fusions, including the large EWS-FLI-1 transcripts, with the equivalent of 100 tumor cells as a starting material. This multiplex fluorescent analysis of chromosome translocations (MFACT) was validated in comparison with conventional RT-PCR on a series of 79 tumors. A major advantage of this method is that it completely abolishes the manipulation of PCR-products. It, therefore, considerably lowers the risk of cross-contamination linked to carry-over of RT-PCR products. It also constitutes an important step toward the complete automation of the detection of cancer-specific gene fusions.

Artificial Gene Fusion↗

Multiplex detection of hotspot mutations by rolling circle-enabled universal microarrays.

Detection of somatic low abundance mutations in early cancer development requires a discriminatory, specific, and high-throughput methodology. In this study we report specific, discriminatory detection of low abundance mutations through a novel combination of rolling circle amplification (Nat Genet 1998; 19:225-232) and PCR ligation detection reaction on a universal oligonucleotide microarray (J Mol Biol 1999; 292:251-262). After mutation-specific multiplex ligation and hybridization of 17 pairs of probes to a generic microarray, the ligated probes were visualized. The multiplex mutation-specific ligation is possible only because rolling circle amplification permits quantification of previously undetectable hybridization events conducive to the detection of a single mutation from within a pool of over 100 wild-type alleles. This system is readily adaptable to high-throughput automation using a robot such as the Biomek platform.

Automation↗