Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAMMOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52Linked to original sources

Social processes used by African American women in making decisions about mammography screening.

PURPOSE: To describe the social processes used by African American (AA) women ages > or = 50 years in making decisions about mammography screening. DESIGN: Grounded theory methodology. METHODS: Tape-recorded interviews with a researcher-designed, semi-structured interview guide with an initial and theoretical sample of 30 AA women ages 52 to 71 of diverse socioeconomic status. Interviews occurred in various settings such as the church rectory, women's homes, and work settings. Extensive written field notes and tapes were transcribed verbatim immediately after the interviews by an experienced transcriptionist. FINDINGS: The women's decisions about mammography screening were associated with five social processes: (a) acknowledging prior experiences with healthcare providers and systems; (b) reporting fears and fatalistic beliefs of breast cancer and related treatment; (c) valuing the opinions of significant others; (d) relying on religious beliefs and supports; and (e) caregiving responsibilities of significant others. The processes were further differentiated by three distinct decision-making styles: taking charge, enduring, and protesting. CONCLUSIONS: Each of the social processes was reported equally and emphasized by the diverse sample of AA women in decisions related to mammography screening. Mammography screening decisions were heavily influenced by caregiving responsibilities. Further research is needed to explain and understand this social process on the health and well-being of AA women over time.

Adaptation, Psychological↗

The influence of mammography screening on the pathological panorama of breast cancer.

The pathologist describes the biological domain of breast cancer in which the clinician works. Over the last 20 years there have been indications that the biological domain has shifted following the introduction of fine-needle biopsies, clinical mammography, and later screening mammography. The most commonly used parameters for staging, classification and grading of cancer in some respects probably reflect the biological domain. We describe how the pathological panorama of breast cancer has changed with the introduction of population-based mammography screening. Our experiences are based on a consecutive series of 1961 breast cancers diagnosed from 1977 to 1994 in a region where screening mammography was introduced in 1988. All results, including histological classification and grading were prospectively registered in a computerized data base. There were more comedo than tubuloductal carcinomas and there was a corresponding preponderance of grade III tumours in the youngest and a high incidence of tubuloductal, lobular and colloid cancers in the oldest age group. The proportion of women with comedo carcinoma decreased after 1987. Looking at changes in the grade distribution after 1987, the proportion of women with grade I tumours increased and grade III tumours decreased in women over 50 years of age, but in the youngest women only marginal changes were noted. Very few in situ carcinomas were diagnosed in the prescreening period. About 11% of all tumours were in situ after 1987. The percentage of node-positive cancer decreased in the screening period in all histological types of cancer regardless of tumour size. The percentage of small tumours < or = 20 mm increased with time, though less so for comedo carcinomas. Comedo carcinomas dominate among the largest cancers most frequently detected clinically. From a biological standpoint it is interesting to note that screening seems to entail a larger shift in the biological domain in older as compared to younger women. Furthermore, comedo carcinomas seem to be less well detected by the screening procedure.

Adult↗

The relationship of social support to women's obtaining mammography screening.

This study examined the relationship between social support and obtaining mammography screening. Fifty women, half of whom had undergone mammography, were matched for age and ethnicity and interviewed related to perception of their social support networks. Results revealed a significant difference in the levels of social support and mammography screening. Women who had undergone mammography perceived a higher level of social support than those who had not. Parse's Theory of Human Becoming was used as a framework to discuss nursing implications of the findings.

Cooperative Behavior↗

Women's perceptions of screening mammography.

A random sample of women in Sydney were interviewed by telephone to determine their knowledge about and attitudes to mammography. A response rate of 56 per cent (628 women) was obtained. While the majority of women had had some experience with breast cancer, knowledge about which age groups were most at risk and treatment alternatives was limited. Only about half of the sample had heard about screening mammography before the survey. However, when a simple explanation was given, 79 per cent expressed a favourable attitude toward it. Only 22 per cent of women thought of themselves as being personally susceptible to breast cancer; the proportion was lower in women over 60 than in those in their 40s. Morbid concern about breast cancer was rare. About a quarter of the sample expressed concern about mammographically induced exposure to radiation. Attitudes and perceptions of personal susceptibility were not associated with knowledge about risks of breast cancer. However, having a favourable attitude and a lack of concern about radiation were associated with previously having heard about screening mammography. Women speaking a language other than English at home and from households where the main income earner was in an unskilled occupation were least likely to have heard of screening mammography. Suggestions for data-based recruitment strategies are discussed.

Attitude to Health↗

Development of contrast digital mammography.

Development of breast tumors is often accompanied by angiogenesis--the formation of new blood vessels. It is possible to image the effects of this process by tracking the uptake and washout of contrast agents in the vicinity of a lesion. In this article, a method for carrying out contrast subtraction mammography on a full-field digital mammography unit is described. Spectral measurements and modeling were performed to optimize the choice of x-ray target, kilovoltage and x-ray beam filtration for contrast digital mammography (CDM) on an available digital mammography system. Phantom studies were carried out to determine the sensitivity of CDM to iodine. Detection of iodine area densities of 0.3 mg/cm2 is possible for a circular object with a radius of 1.3 mm, which allows detection of uptake levels in the breast typically seen with cancer and some benign breast conditions. It was found that with a molybdenum anode x-ray tube, copper filtration could be used to effectively shape the x-ray spectrum to maximize the proportion of x rays with energies above the k edge of iodine. Simple logarithmic subtraction was found to be adequate in suppressing background signals dependent on the x-ray beam intensity and background thickness of the breast. The total x-ray dose from the procedure ranges between 1 and 3 mGy, similar to that from a conventional single view film mammogram. A clinical pilot study is currently being carried out to evaluate this technique.

Algorithms↗

Characterization of metal oxide semiconductor field effect transistor dosimeters for application in clinical mammography.

Five high-sensitivity metal oxide semiconductor field effect transistor dosimeters in the TN-502 and 1002 series (Thomson Nielsen Electronics Ltd., 25B, Northside Road, Ottawa, ON K2H8S1, Canada) were evaluated for use in the mammography x-ray energy range (22-50 kVp) as a tool to assist in the documentation of patient specific average glandular dose. The dosimeters were interfaced with the Patient Dose Verification System, model No. TN-RD 15, which consisted of a dosimeter reader and up to four dual bias power supplies. Two different dual bias power supplies were evaluated in this study, model No. TN-RD 22 in high-sensitivity mode and a very-high sensitivity prototype. Each bias supply accommodates up to five dosimeters for 20 dosimeters per system. Sensitivity of detectors, defined as the mV/C kg(-1), was measured free in air with the bubble side of the dosimeter facing the x-ray field with a constant exposure. All dosimeter models' angular response showed a marked decrease in response when oriented between 120 degrees and 150 degrees and between at 190 degrees and 220 degrees relative to the incident beam. Sensitivity was evaluated for Mo/Mo, Mo/Rh, and Rh/Rh target-filter combinations. The individual dosimeter model sensitiVity was 4.45 x 10(4) mV/C kg(-1) (11.47 mV R(-1)) for TN-502RDS(micro); 5.93 x 10(4) mV per C kg(-1) (15.31 mV R(-1)) for TN-1002RD; 6.06 x 10(4) mV/C kg(-1) (15.63 mV R(-1)) for TN-1002RDI; 9.49 x 10(4) mV per C kg(-1) (24.49 mV R(-1)) for TN-1002RDM (micro); and 11.20 x 10(4) mV/C kg(-1) (28.82 mV R(-1)) for TN-1002RDS (micro). The energy response is presented and is observed to vary with dosimeter model, generally increasing with tube potential through the mammography energy range. An intercomparison of the high-sensitivity mode of TN-RD-22 was made to the very-high sensitivity bias power supply using a Mo/Mo target-filter. The very-high sensitivity-bias power supply increased dosimeter response by 1.45 +/- 0.04 for dosimeter models TN-1002RD and TN-1002RDM. The responses of all dosimeter models were found to be linear for tube potentials of between 24 and 48 kVp. Dosimeters showed a reproducibility varying from 15.5% to 31.8%. depending on the model of dosimeter. Micro MOSFETS model Nos. TN-1002RDS and TN-1002RDM used in conjunction with their respective high-sensitivity and ultrahigh-sensitivity bias supplies provided the highest sensitivity response of the models evaluated. Either micro MOSFETS model No. TN-1002RDS or TN-1002RDM used in conjunction with the appropriate bias supply provide the best choice for clinical mammography applications. Under these conditions, MOSFET dosimeters can provide a viable option as a dosimeter in the mammography energy range (22-50 kVp). The clinical application of MOSFET dosimeters must take into account the energy dependence and reproducibility to ensure accurate measurements.

Humans↗

Relative carcinogenic effects of different mammography techniques.

Comparisons of different mammography techniques can be significantly altered by assumptions about the relevant measures for carcinogenic effects in mammography at low doses. Using a combination of recent data available from the literature, a study as been made of the significance of various assumptions concerning both the appropriate measures for carcinogenesis in mammography and the shape of the dose-effects relationship. It is found that for techniques typical of current reduced-dose mammography systems, the comparison of the relative carcinogenic effects of the techniques is significantly affected by both the measures that are used and the shape of th dose-effects relationship.

Breast Neoplasms↗

Mammography film processor replenishment rate: bromide level monitoring.

The effects of the mammography film processing replenishment rate on contrast and speed are studied sensitometrically. Two experiments studied decreasing replenishment rates in the Kodak RP developer and quantified changes in the developer by measuring bromide ion concentrations. First, values of NaBr concentration from 1.7 to 8.4 g/L, achieved by reducing the replenishment rate, were tested with sensitometry strips. Second, the developer replenishment rate of a high volume dedicated mammography processor was reduced by one-third, to 20 cm3/1560 cm2, so that the NaBr concentration rose from 2.0 to 12.36. Sensitometric results for four film types and patient films were tested for changes from standard values as NaBr concentration was restored to 3.31 g/L. Fifty-five clinical images obtained at 7.3-9.3 NaBr g/L were compared to their matching previous films, with NaBr levels of 2-3 g/L, for contrast and visibility of the skin line. For the range of the NaBr ion from 1.7 to 7 g/L, no significant sensitometric differences were found. Above 7 g/L, different film types had different sensitometric results. From 7.3 to 9.3 NaBr g/L, 47.5% of the clinical films reviewed by four radiologists had less contrast compared to previous films. Dedicated mammography processors with high film volume (i.e., those that do not have excessive oxidation or foreign dye problems) can operate at lower replenishment rates than are currently employed. All common mammography film types are stable at these lower replenishment rates up to 7.0 NaBr g/L.

Biophysical Phenomena↗

Mammography screening: an incremental cost effectiveness analysis of two view versus one view procedures in London.

STUDY OBJECTIVE: To compare the costs and effects of routine mammography screening by a single mediolateral-oblique view and two views (mediolateral-oblique plus craniocaudal) of each breast. DESIGN: A cost effectiveness analysis of a prospective non-randomised trial comparing one and two view mammography screening was carried out at St Margaret's Hospital, Epping. All women in the study had two view mammography. The mediolateral-oblique view was always the first image read by the radiologist. After reading the films for a clinic session, the same radiologist then went back and read both the mediolateral-oblique and craniocaudal views together. Each set of films was read by two radiologists. The main outcome measures were recall rates, number of cancers detected, screening and assessment costs, and cost effectiveness ratios. SUBJECTS: A total of 26,430 women who attended for breast screening using both one and two view mammography participated. A sample of 132 women attending for assessment provided data on the private costs incurred in attending for assessment. RESULTS: There was a reduction in the recall rate from 9.1% (2404 of 26,430) after one view screening to 6.7% (1760 of 26,430) after two view screening. The results also suggest that for every 10,000 women screened an additional five cancers would be detected earlier with two view screening. The additional health service screening cost associated with two view screening was estimated to be 3.63 pounds: the costs associated with one and two view screening policies were estimated to be 41.49 pounds and 32.99 pounds respectively. Private costs incurred were estimated to be 0.35 pounds per woman screened and 32.75 pounds per woman assessed. Two cost effectiveness ratios were calculated: an incremental health service cost per additional cancer detected of 4129 pounds and an incremental health service plus private cost per additional cancer detected of 2742 pounds. The sensitivity analysis suggested that the results were sensitive to relatively large changes in a number of parameters. These included screening costs, assessment costs, equipment life, and recall rates. CONCLUSIONS: Use of two view screening increased early cancer detection and also costs. The reduction in the recall rate with two views was not sufficiently large to make the cost of two view screening neutral. While these results are not completely generalisable, a framework is provided to allow other centres to estimate the cost effectiveness of two view screening in their locality.

Breast Neoplasms↗

Psychosocial predictors of first attendance for organised mammography screening.

OBJECTIVE: To study psychosocial predictors of attendance at an organised breast cancer screening programme. SETTING: Finnish screening programme based on personal first round invitations in 1992-94, and with 90% attendance rate. METHODS: Attenders (n = 946) belonged to a 10% random sample (n = 1680 women, age 50, response rate 64%) of the target population (n = 16,886), non-attenders (n = 641, 38%) came from the whole target population. Predictors were measured one month before the screening invitation. Measures included items for social and behavioural factors, Breast Cancer Susceptibility Scale, Illness Attitude Scale, Health Locus of Control Scale, Anxiety Inventory, and Depression Inventory. Univariate and multivariate logistic regression analyses were used to predict attendance. RESULTS: Those most likely to attend were working, middle income, and averagely educated women, who had not had a mass mammogram recently, but who regularly visited gynaecologists, attended for Pap smear screening, practised breast self examination, and who did not smoke. Low confidence in their own capabilities in breast cancer prevention, overoptimism about the sensitivity of mammography, and perception of breast cancer risk as moderate were also predictive of attendance. Expectation of pain at mammography was predictive of non-attendance. CONCLUSION: Mammography screening organised as a public health service was well accepted. A recent mammogram, high reliance on self control of breast cancer, and an expectation of pain at mammography deterred attendance at screening. Further information about these factors and health information on screening are needed.

Breast Neoplasms↗

Effect of distance and social disadvantage on the response to invitations to attend mammography screening.

STUDY OBJECTIVES: To investigate whether public response to an invitation to attend mammography screening can be increased by strategic relocation of the clinics. METHODS: Women invited to attend mammography screening were classified by attendance, socioeconomic status, and distance from their screening clinic. A geographic information system was used to investigate whether the response could be increased by relocating clinics to facilitate access. SETTING: The metropolitan city of Perth in Western Australia with six fixed site, publicly funded, mammography screening clinics. MAIN RESULTS: Women from disadvantaged areas, not screened previously by the mammography screening programme, had a higher response to an invitation to attend screening if they lived within 3 km of their closest clinics (12%) than if they lived further away (8%). Theoretically, the response of the target population could be increased if the existing clinics were replaced by six new clinics located closer to disadvantaged areas. CONCLUSIONS: Public health planners should be aware of the use of geographic information systems to model optimum locations of health care facilities, and be willing to assess the potential target population response to those locations.

Demography↗

Ten years of breast screening in the Screening Mammography Program of British Columbia, 1988-97.

OBJECTIVES: To evaluate 10 years outcomes of the Screening Mammography Program of British Columbia (SMPBC) and determine if breast screening targets were being achieved among women aged 40-80+ years. SETTING: Organised breast screening programme in British Columbia, Canada. METHODS: Rates of participation, abnormal referral, cancer detection, and interval cancer were calculated for asymptomatic women receiving an SMPBC mammography from 1988-97. RESULTS: 895,849 screening mammographies were provided to 335,433 women. 51.3% of women were age 50-69 years. Abnormalities were identified on 57,454 screens (6.4%) from which 3304 cancers were detected. Abnormal call rates were higher on first (9.8%), compared with subsequent screens (4.4%) and declined with age: 7.7% at age < 40 to 5.4% for age 70-79 years. Cancer detection rates were higher on first (5.0 per 1000) compared with subsequent screens (2.8 per 1000) and increased smoothly with age from 1.4 to 8.2 per 1000 from age < 40 to age 80 years and older. Twenty per cent of cancers were non-invasive. The median size of invasive cancers was 14 mm and 81% had no axillary lymph node metastases. The 12 month interval cancer rate was 0.6 per 1000 and did not vary significantly with age or screening history. The prevalence to expected incidence ratio was 3.1 for women age 50-79 years. CONCLUSION: Across a broad range of ages, surrogate indices of screening mammography success have been achieved in a population based, North American, organised breast cancer screening programme.

Adult↗

Predictors of non-attendance for second round mammography in an Australian mammographic screening programme.

OBJECTIVE: To determine the socioeconomic, cultural, and clinical predictors of non-attendance for second round mammography. DESIGN/PARTICIPANTS: Retrospective cohort study of 121 889 women aged 50-69 years who attended for first mammography screening in the BreastScreen Victoria programme in 1995/1996 and who were recommended to be invited for routine biennial mammography. Women were considered to be non-attenders if they had not attended for rescreening within 27 months of their initial screening. Relative risk (RR) was used to compare categories for non-attendance for second screening, and a multivariate model was fitted to adjust for possible confounding. SETTING: BreastScreen Victoria, a population based mammographic screening programme, which offers free biennial mammography to all women 40 years and older. The programme specifically targets women aged 50-69 years. RESULTS: In the multivariate analysis, women from non-English speaking backgrounds were more likely not to attend for second round screening (RR ranged from 1.18 to 1.77). Indigenous women (RR 2.02, 95% confidence interval (CI) 1.61 to 2.54) and women who reported either significant symptoms (RR 1.90, 95% CI 1.76 to 2.05) or other breast symptoms (RR 2.25, 95% CI 2.15 to 2.36) at the time of first round screening were also more likely not to attend for second round screening. CONCLUSIONS: Women from non-English speaking backgrounds, indigenous women, and women who report symptoms at the time of first screening are more likely to not attend for second round screening. It is important to investigate why these women do not attend for second round screening so that services can be more appropriately tailored to their needs.

Africa, Northern↗

Risk versus benefit in mammography.

Controversy surrounds the use of mammography in asymptomatic women 35-49 years of age. There is agreement that routine mammography is useful beyond 50 years. By extrapolating data from relatively high radiation exposures, a radiation carcinogenic risk at diagnostic levels has been calculated by some workers. Benefit for asymptomatic women in the 35-49 year age group has been questioned. This paper presents evidence that significant numbers of breast cancers are found in this age period on the basis of x-ray examination alone. Data also indicate absorbed dose from modern-day mammography is half to one quarter of that previously assumed. Based on these data, mammography is recommended as a tool for diagnosis of nonpalpable carcinomas of the breast.

Adult↗

Clinical breast examination practices among women undergoing screening mammography.

PURPOSE: To determine the proportion of women who underwent clinical breast examination (CBE) within 12 months before undergoing screening mammography and to examine which factors, if any, were associated with having undergone CBE within 12 months before screening mammography. MATERIALS AND METHODS: A cross-sectional study of 1,135 women presenting for screening mammography was conducted with a self-administered questionnaire. Data were collected regarding sociodemographic information, health care provider information, breast self-examination practices, and CBE history. Data were analyzed with the chi(2) test of independence. RESULTS: One hundred forty (38.5%) of 364 nonwhite women and 366 (57.4%) of 638 white women reported having undergone CBE 12 months before screening mammography. This association between race and CBE was statistically significant before (P <.001) and after adjusting for education, age, and type of referring physician (P <.001). There was a statistically significant association between undergoing CBE within 12 months and age (P <.001), type of referring physician (P <.001), and education level (P <.001). Health insurance status was associated with having undergone CBE within the past 12 months, but it was not a statistically significant association after controlling for race. CONCLUSION: The proportion of women who undergo comprehensive breast cancer screening differs by race, education level, and type of referring physician.

Adult↗

Follow-up of palpable circumscribed noncalcified solid breast masses at mammography and US: can biopsy be averted?

PURPOSE: To determine whether palpable noncalcified solid breast masses with benign morphology at mammography and ultrasonography (US) can be managed similarly to nonpalpable probably benign lesions (Breast Imaging Reporting and Data System [BI-RADS] category 3)-that is, with periodic imaging surveillance-and to determine whether biopsy can be averted in these lesions. MATERIALS AND METHODS: No institutional review board approval or patient consent was required. This retrospective analysis, based on final imaging reports, included 152 patients (age range, 28-77 years; mean age, 48.3 years) with 157 palpable noncalcified solid masses that were classified as probably benign at initial mammography and US. Of 152 patients, 108 underwent follow-up with mammography and US (6-month intervals for 2 years, then 12-month intervals). The remaining 44 patients underwent surgical or needle biopsy after initial imaging. Lesions were analyzed at initial and follow-up examinations. Statistical analysis included Student t test and corresponding exact 95% confidence intervals. RESULTS: In 108 patients who underwent follow-up only, 112 lesions were palpable. In 102 (94.4%) of 108 patients, masses remained stable during follow-up. Lesions were followed for at least 2 years (mean, 4.1 years; range, 2-7 years). In six (5.6%) patients, palpable lesions increased in size during follow-up; these lesions were benign at subsequent open biopsy. No breast carcinoma was diagnosed in the 44 patients with 45 palpable lesions who underwent biopsy after initial imaging. Of 157 lesions, no malignant tumors were observed (exact one-sided 95% confidence interval: 0%, 1.95%). CONCLUSION: The data strongly suggest that palpable noncalcified solid breast masses with benign morphology at mammography and US can be managed similarly to nonpalpable BI-RADS category 3 lesions, with short-term follow-up (6-month intervals for 2 years). More data, based on a larger series, are required to determine whether this conclusion is correct.

Adult↗

Association between mammography timing and measures of screening performance in the United States.

PURPOSE: To evaluate whether there is an association between the number of months since previous mammography (MSPM) and performance measures (sensitivity, specificity, recall rate, cancer detection rate, and positive predictive value) in women who underwent U.S. community-based screening mammography. MATERIALS AND METHODS: Data from seven registries (Breast Cancer Surveillance Consortium) and mammographic data and cancer outcome in regard to 1 213 754 screening mammographic examinations performed in 680 641 women who were 40-89 years old for the years 1996-2000 were used in this study. These data are submitted annually in a standard format to a central statistical coordinating center that is subject to institutional review board approval, quality control, and confidentiality standards. Performance measures were calculated for first and subsequent screening mammography. For subsequent mammography, performance measures were calculated according to categories of MSPM (9-15, 16-20, 21-27, and >/=28 months). Receiver operating characteristic and multivariable logistic regression analyses were conducted to test the association between the number of MSPM and performance measures. RESULTS: With increasing MSPM in each category from 9-15 to 28 months or more and for first mammographic examinations, respectively, there was increased sensitivity (70.9%, 75.7%, 85.4%, 82.5%, and 88.6%), decreased specificity (93.3%, 92.7%, 91.6%, 91.0%, and 85.9%), increased recall rate (7.0%, 7.6%, 8.8%, 9.4%, and 14.7%), and increased cancer detection rates (3.2, 3.5, 4.5, 4.6, and 6.1 per 1000 mammographic examinations). When the category of 9-15 MSPM was compared with that of 21-27 MSPM, there was a slight increase in positive predictive value from 4.6% to 5.1%. Confidence intervals were narrow and did not overlap. Age affected these associations for all performance measures except sensitivity. CONCLUSION: Performance measures increased as MSPM increased, except for specificity, which decreased. Time between mammograms is an important factor to consider when audits are reviewed or screening performance measures are compared.

Adult↗

Breast lesion detection and characterization at contrast-enhanced MR mammography: gadobenate dimeglumine versus gadopentetate dimeglumine.

PURPOSE: To prospectively and intraindividually compare equivalent (0.1 mmol per kilogram of body weight) doses of gadobenate dimeglumine and gadopentetate dimeglumine for accuracy of detection and characterization of breast lesions at contrast material-enhanced magnetic resonance (MR) mammography. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained. Twenty-six consecutive women (mean age, 47.8 years) suspected of having a breast tumor at mammography and sonography underwent two identical MR examinations at 1.5 T; examinations were separated by more than 48 hours but less than 72 hours. A T1-weighted three-dimensional gradient-echo sequence was used, and images were acquired before and at 0, 2, 4, 6, and 8 minutes after randomized injection of gadopentetate dimeglumine or gadobenate dimeglumine at an identical flow rate of 2 mL/sec. Separate and combined assessment of unenhanced, contrast-enhanced, and subtracted images was performed blindly by two readers in consensus. Accuracy for lesion detection was determined against a final diagnosis based on findings at conventional mammography, sonography, and surgery. Sensitivity, specificity, positive and negative predictive values, and overall accuracy for malignant lesion identification were determined against histologic results. Data were analyzed with the McNemar test, proportional odds models, and analysis of variance. RESULTS: MR mammography with gadobenate dimeglumine depicted significantly (P = .003) more lesions (45 of 46) than did that with gadopentetate dimeglumine (36 of 46), and detected lesions were significantly (P < .001) more conspicuous with gadobenate dimeglumine. Confidence for characterization was significantly (P = .031) greater with gadobenate dimeglumine. Comparison of the contrast agents for their ability to help identify malignant lesions revealed significant (P = .02) superiority for gadobenate dimeglumine: Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy for malignant lesion identification were, respectively, 94.7%, 100%, 100%, 80.0%, and 95.6% with gadobenate dimeglumine and 76.3%, 100%, 100%, 47.1%, and 80.4% with gadopentetate dimeglumine. Quantitative evaluation of signal intensity-time curves revealed significantly (P < .001) greater lesion enhancement with gadobenate dimeglumine. CONCLUSION: Detection of breast lesions and accurate identification of malignant lesions at MR imaging are significantly superior with gadobenate dimeglumine in comparison with gadopentetate dimeglumine.

Adult↗