Use of distal femoral osteoarticular allografts in limb salvage surgery.

BACKGROUND: As diagnostic and therapeutic techniques improve, patients with a musculoskeletal sarcoma should expect longer survival, fewer complications and side effects, and an improved quality of life. Functional longevity of the reconstruction after resection of the tumor becomes a major concern, especially in young and physically active patients. The purpose of this study was to analyze the mid-term and long-term survival of reconstructions with a distal femoral osteoarticular allograft in a series of patients. METHODS: We retrospectively reviewed the results of eighty reconstructions with a distal femoral osteoarticular allograft following resection of a bone tumor in seventy-six patients. The mean duration of follow-up was eighty-two months. The rates of survival of the allograft and the joint surface were estimated with use of the Kaplan-Meier method. Cox regression analysis was performed to determine whether age, gender, the percentage of the femur that had been resected, and the use of chemotherapy were independent prognostic factors. Functional and radiographic results were documented according to the Musculoskeletal Tumor Society scoring system at the time of the latest follow-up. RESULTS: Five patients were lost to follow-up, leaving seventy-five allografts in seventy-one patients available for study. Thirteen patients (thirteen allografts) died of tumor-related causes without allograft failure before a two-year radiographic follow-up could be performed. Of the remaining sixty-two allografts, fourteen failed: six failed as a result of infection; four, because of local recurrence; one, because of massive resorption; and three, as a result of fracture. At the time of final follow-up, at a mean of 125 months, forty-eight allografts were still in place. The overall rate of allograft survival was 78% at both five and ten years, and the rate of allograft survival without the need for resurfacing with a knee prosthesis was 71% at both five and ten years. With the numbers available, age, gender, the percentage of the femur that had been resected, and the use of chemotherapy were not found to have a significant effect on the overall allograft survival rates. The patients who retained the original allograft had good or excellent functional and radiographic results. CONCLUSIONS: The life expectancy for most patients with a highly aggressive or malignant tumor in the distal part of the femur is now several decades. In this study, we found a high rate of survival of distal femoral allograft reconstructions at both five and ten years.

Adolescent↗

Use of distal femoral osteoarticular allografts in limb salvage surgery. Surgical technique.

BACKGROUND: As diagnostic and therapeutic techniques improve, patients with a musculoskeletal sarcoma should expect longer survival, fewer complications and side effects, and an improved quality of life. Functional longevity of the reconstruction after resection of the tumor becomes a major concern, especially in young and physically active patients. The purpose of this study was to analyze the mid-term and long-term survival of reconstructions with a distal femoral osteoarticular allograft in a series of patients. METHODS: We retrospectively reviewed the results of eighty reconstructions with a distal femoral osteoarticular allograft following resection of a bone tumor in seventy-six patients. The mean duration of follow-up was eighty-two months. The rates of survival of the allograft and the joint surface were estimated with use of the Kaplan-Meier method. Cox regression analysis was performed to determine whether age, gender, the percentage of the femur that had been resected, and the use of chemotherapy were independent prognostic factors. Functional and radiographic results were documented according to the Musculoskeletal Tumor Society scoring system at the time of the latest follow-up. RESULTS: Five patients were lost to follow-up, leaving seventy-five allografts in seventy-one patients available for study. Thirteen patients (thirteen allografts) died of tumor-related causes without allograft failure before a two-year radiographic follow-up could be performed. Of the remaining sixty-two allografts, fourteen failed: six failed as a result of infection; four, because of local recurrence; one, because of massive resorption; and three, as a result of fracture. At the time of final follow-up, at a mean of 125 months, forty-eight allografts were still in place. The overall rate of allograft survival was 78% at both five and ten years, and the rate of allograft survival without the need for resurfacing with a knee prosthesis was 71% at both five and ten years. With the numbers available, age, gender, the percentage of the femur that had been resected, and the use of chemotherapy were not found to have a significant effect on the overall allograft survival rates. The patients who retained the original allograft had good or excellent functional and radiographic results. CONCLUSIONS: The life expectancy for most patients with a highly aggressive or malignant tumor in the distal part of the femur is now several decades. In this study, we found a high rate of survival of distal femoral allograft reconstructions at both five and ten years.

Adolescent↗

Potential problems of manufacture and fitting of polypropylene ultralightweight below-knee prostheses.

The clinical evaluation of an ultralightweight polypropylene below-knee prosthesis conducted by the University of Strathclyde identified a number of potential problems which can arise from the use of polypropylene. This paper describes the problems associated with manufacture, loss of alignment and fitting, and indicates handling techniques to minimize these problems.

Artificial Limbs↗

Foot loading in amputee stance.

A survey has been carried out to establish information on foot loading in amputee stance. The parameters measured are percentage body weight and the positions of the centres of pressure under each foot. The data was collected in a clinical environment by the use of a Double Video Forceplate (DVF), a tool developed at the Bioengineering Centre. The objective of the survey is to provide background information for the use of the DVF in static alignment of lower-limb prostheses. Results are presented from a number of patients attending the Roehampton Walking Training School, and for a small group of patients attending the Bioengineering Centre for delivery of an experimental below-knee prosthesis. Scattergrams and averaged results provide normative data which can assist in interpretation of DVF displays during individual alignment.

Adolescent↗

Immune-inflammatory response in infected arthroplasties.

We studied the immunocytology of synovial fluid in purulent endoprosthetic infections using cell subtype-specific monoclonal antibodies in avidin-biotin-peroxidase complex staining. Two thirds of the monocytes were CD15-positive, whereas CD2-positive T lymphocytes only formed one third of all the mononuclear cells. The synovial fluid monocyte-activated T-cell ratio differed from findings in sterile inflammatory, reactive and rheumatoid arthritis.

Adult↗

The osteogenic properties of the interface membrane at the site of orthopedic implants: the impact of underlying joint disease.

Osseointegration at the site of orthopedic implants is dependent on the recruitment, attachment, and differentiation of osteogenic cells. Data concerning the effect of a patient's underlying joint disease on the modulation of the cellular activity and the long-term survival of joint prostheses is limited. In this study, immunocytochemistry was used to investigate the osteogenic cell phenotype within the bone-implant interface fibrous membrane in 60 patients with different underlying joint disease. Tissue specimens were removed during revision operations performed at variable times following implantation. The results provided histological evidence of the presence of fibrocartilage tissue and calcified bone within the interface. TGF-beta, metalloproteinases (MMP1 and MMP2) and their inhibitors (TIMP1 and TIMP2) were immunolocalized within fibroblasts, chondrocytes, and osteoblasts throughout the interface, indicating that signals modulating the osteogenic cell phenotype at these sites are highly regulated. Finally, the study identified a significant difference in the histological changes elicited by implant particulate debris in patients of different diagnostic categories. Such observations imply that the activity of the original joint disorder could augment specific cellular activation/immune signals that subsequently affect the degree of the local inflammatory responses to implant wear particles. The negative balance between the rate of bone growth and resorption around the prosthetic joint is central to the pathogenesis of aseptic loosening of implants.

Adult↗

[Construction principles, strength investigation and early clinical results of the Integracja osteosynthesis system: a preliminary report].

The aim of this paper was to present the construction principles and strength investigation of the Integracja osteosynthesis system. Preliminary results of fracture treatment in 6 patients with hip and knee prosthesis are presented. Inc all cases bony union was obtained. Integracja can be successfully used in femur fractures near the tip of the prosthesis shaft.

Fracture Fixation, Internal↗

The spectrum of prosthesis design for primary total knee arthroplasty.

Many types of prostheses are currently used for total knee arthroplasty. Controversy exists, however, regarding which prostheses are the most appropriate for use by individual surgeons and specific patient groups. Six types of prostheses are currently being used in the United States for primary total knee arthroplasty: posterior cruciate ligament-retaining prostheses; posterior cruciate ligament-substituting prostheses; prostheses with ceramic components; mobile-bearing prostheses; nonmodular, compression-molded polyethylene prostheses; and medial-pivot prostheses. The historical and current result of using these different types of prostheses are discussed, and the indications, contraindications, and recommendations for each type are delineated.

Anterior Cruciate Ligament↗

The prosthesis-bone interface in total knee arthroplasty.

Classic methods of implant component fixation, including the use of screw and impact-tapered, interference-fit stabilization, have provided longevity of function for total knee arthroplasties (TKAs). Optimal cement stabilization may be limited by the degradation characteristics of methyl-methacrylate. Modern application of porous coating for bony ingrowth fixation has not been as successful as expected, particularly as applied to the tibial component in TKA. Based on their in vivo research, the authors have developed a tibial component with an array of porous-coated cones that ensure immediate fixation and a graduated stress field to the host trabecular bone. This may improve the reliability and durability of tibial component fixation.

Animals↗