Jet gun intralesional therapy.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Injuries to the cervical region have been associated with high-G loads sustained during air combat maneuvering (ACM) in high performance fighter aircraft. The spectrum of injuries ranges from mild neck pain to musculoskeletal strain, injury to the nerve roots or spinal cord, and fracture of the cervical spine. A 36-year-old fighter pilot with 2,800 h in tactical jet aircraft developed progressive cervical dystonia (spasmodic torticollis), following an ACM flight. The patient was successfully treated with local intramuscular injections of botulinum toxin into the affected cervical muscles, resulting in total relief of his spasmodic torticollis. The aeromedical considerations of this rare complication of exposure to G forces in high performance aircraft are discussed.
The authors describe the case history of a patient who suffered from symptoms deriving from two different origins. The patient's voice was spasmodic dysphonia-like interrupted and pressed. At the same time, his voice was powerless, too. The reason for this was that besides the spasmodic dysphonia caused by hyperkinesis, an incomplete closure of the vocal cords during phonation in the middle third was present. It was caused by the atrophy of the vocal cords. In order to eliminate the symptoms, initially we injected 25 IU Botox into the left vocal cord transcutaneously under the direction of EMG control. It resulted in a fluent, though breathy voice. In order to manage the closing insufficiency during phonation, we performed lipoaugmentation on the left vocal cord under high-frequency jet anaesthesia. The result of the two-step procedure was a fluent and clear voice. The speech without interruption lasted for 5 months, until the drug was eliminated. Of course, to prolong the result, the Botox injection should be repeated.
A new technique for the administration of a bronchodilator aerosol, fenoterol, in young children with asthma is described. Rapid and effective bronchodilatation can be obtained in many patients simply by directing the jet of the bronchodilator aerosol onto the buccal mucosa. This method will frequently obviate the need for painful or potentially dangerous injections of adrenaline or aminophylline as a first-line treatment in children with acute attacks of asthma.
Explore the source record for details and available documents.
This study evaluates the feasibility and safety of a 6Fr hydrodynamic thrombectomy catheter, the Hydrolyser, in native coronary arteries and aortocoronary bypass grafts. With use of a conventional contrast injector, saline solution is injected into the narrow lumen of the catheter which makes a 180 degrees bend at the tip. The resultant high-velocity jet (150 km/hour) is directed over a sidehole near the tip into a wide exhaust lumen. As a consequence of the Venturi effect, thrombus is sucked into that sidehole, fragmented, and removed through the wide exhaust lumen into a collection bag. Thirty-one thrombotic lesions were treated in 31 patients. The culprit vessel was a venous graft in 21 patients (15 with Thrombolysis in Myocardial Infarction Trial [TIMI] grade 0 or 1 flow) and a coronary artery in 11 patients (9 with grade 0 or 1 flow). Twenty-six patients had angina New York Heart Association functional class III or IV heart failure and 5 an acute myocardial infarction. In 26 patients, Hydrolyser therapy was the primary treatment, whereas in 5 patients coronary angioplasty preceded Hydrolyser therapy. In 1 patient the Hydrolyser could not reach the lesion. Thrombus was removed in 29 of the 31 patients. Successful reperfusion (TIMI grade 2 or 3 flow) by Hydrolyser therapy alone was achieved in 14 of the 24 patients with TIMI grade 0 or 1 flow before the procedure. Adjunctive therapy (coronary angioplasty, stent, or thrombolysis) was performed in 28 of the 31 patients. At the end of the total procedure 24 patients had TIMI grade 3 flow. Distal embolization during thrombectomy occurred in 2 patients, which led to a non-Q-wave infarction in 1. No patient died or needed emergency coronary bypass due to the Hydrolyser procedure. Thus, thrombectomy using the 6Fr Hydrolyser is feasible and was performed safely in 31 patients.
INTRODUCTION: Positive pressure breathing for G-protection (PBG) reduces the need for fighter pilots to use the fatiguing anti-G straining maneuver (AGSM) so that they can better endure high acceleration (+Gz). The aim of the study was to determine the differences in cerebral blood flow during flight with an extended-coverage anti-G suit (ECGS) with AGSM or with PBG. METHODS: Subjects were eight male members of the Finnish Air Force. Each was studied in the laboratory at +1 Gz and then during two identical flights in the back seat of the BAe Hawk Mk 51 jet trainer at +6 Gz, first with AGSM and second with PBG (24 mmHg). Regional cerebral blood flow (rCBF) was measured by injecting (99 m) Tc-ECD for deposition at +6 Gz, then scanning the subject in the laboratory an hour later using single photon emission computed tomography (SPECT). RESULT: The rCBF was 30% below baseline for both the AGSM and PBG. CONCLUSIONS: PBG maintained CBF at +6 Gz without the need for the fatiguing AGSM.
Explore the source record for details and available documents.
In a controlled study, functional-scintigraphic investigations into perfusion and ventilation were performed on 10 dogs with non-damaged and extremely severely damaged lungs. The pulmonary damage was produced by injecting oleic acid (OA) into the right atrium of the heart under controlled ventilation (IPPV). The scintigraphic examinations were carried out using 133Xenon. The study compared HFJV (HFJV100, HFJV300) with IPPV in the non-damaged lung as well as HFJV300 with IPPV and CPPV (PEEP 1 kPa) after damage by OA. With the aid of the present radionuclide investigations, new insights can be gained into the largely unclear regional conditions of the gas exchange under HFJV in both the healthy and the damaged lung. Results from controlled studies on the distribution of ventilation and perfusion under HFJV have not been reported to date. The functional-scintigraphic examination with 133Xe on dogs shows, based on specific conditions of the gas exchange and special anatomic conditions of the lungs, a ventilation distribution that differs fundamentally from all other forms of ventilation, including HFOV, preference being given to apical pulmonary segments. This refers to the normal and the damaged lungs alike. However, ventilation-specific changes in pulmonary perfusion do not occur. The resulting deviating regional VA/Q relationship are obviously not of crucial influence upon the gas exchange. Rather, it is influenced and determined by damage-induced intraregional functional-structural alterations in the lung.
A microprocessor controlled flow injection system is described for the determination of vitamin C in foodstuffs. The system is based on amperometric detection at a wall-jet electrode coupled with an ascorbate oxidase packed bed. A commercially available Cartesian robotic auto-sampler-dilutor is used as a means of fully automating the sample handling and dilution. Dithiothreitol (DTT) is used to reduce dehydroascorbic acid to ascorbic acid and to stabilize ascorbic acid standard solutions. Initially, the system was connected in series with a high-performance liquid chromatography column and ultraviolet (UV) detector to allow identification of possible interferents and to allow comparative evaluation of results. The system showed a linear response to the concentration of L-ascorbic acid in the range 1-200 micrograms ml(-1) and was capable of detecting total vitamin C in a range of foodstuffs at a sample throughput of 15 samples h(-1). Correlations to existing methods of 0.98 were obtained.
The authors describe a new angiographic catheter, which delivers equal flow rates through the side holes and reduced flow through the end hole compared with conventional catheters. Computer analysis of catheter-flow models revealed that placement of larger side holes proximally and smaller side holes distally produces more uniform flow rates out of the holes. This decreases the risk of potentially hazardous delivery of high-pressure jets of contrast material from the end hole. The flow pattern is so uniform that it resembles a cloud of contrast material on injection. This catheter design is particularly applicable for 3-5-F catheters, which require high-pressure injections. Clinical testing in 50 cases revealed no extravasations or unintentional selective injections with use of this catheter.
As anyone else, diabetic patients are confronted to professional or private travels. This article is meant to gather some practical recommendations to allow patients to travel safely. All travels must be thoroughly prepared and diabetes must stabilised at best before departure. To avoid severe hypoglycaemias and ketosis are the medical objectives. It is therefore essential that patients take with them their injection material and a sufficient carbohydrate back up. The prevention of diarrheas and vomiting, as well as the adaptation of treatment to jet-lag and all kind of physical activity are necessary to have a nice travel. Some specific aspects of travelling by car, boat or plane are discussed.
Optimum fuel preparation and mixture formation are core issues in the development of modern direct-injection (DI) Diesel engines, as these are crucial for defining the border conditions for the subsequent combustion and pollutant formation process. The local fuel/air ratio can be seen as one of the key parameters for this optimization process, as it allows the characterization and comparison of the mixture formation quality. For what is the first time to the best of our knowledge, linear Raman spectroscopy is used to detect the fuel/air ratio and its change along a line of a few millimeters directly and nonintrusively inside the combustion bowl of a DI Diesel engine. By a careful optimization of the measurement setup, the weak Raman signals could be separated successfully from disturbing interferences. A simultaneous measurement of the densities of air and fuel was possible along a line of about 10 mm length, allowing a time- and space-resolved measurement of the local fuel/air ratio. This could be performed in a nonreacting atmosphere as well as during fired operating conditions. The positioning of the measurement volume next to the interaction point of one of the spray jets with the wall of the combustion bowl allowed a near-wall analysis of the mixture formation process for a six-hole nozzle under varying injection and engine conditions. The results clearly show the influence of the nozzle geometry and preinjection on the mixing process. In contrast, modulation of the intake air temperature merely led to minor changes of the fuel concentration in the measurement volume.
A new flame method of atomic absorption spectrometry is described. The liquid sample to be analyzed is transported as a high-speed liquid jet into a heated tube which is positioned in an air/acetylene flame. The jet is generated by means of an HPLC pump which feeds a smooth jet nozzle having a diameter of 50 microns or smaller. After traveling a distance of 10 cm, the liquid jet enters a small sample introduction hole, impacts onto the opposite inner wall of the tube furnace, and immediately vaporizes (jet impact vaporization, JIV). Both the complete introduction of the entire sample and the extended residence time inside the absorption volume result in an improvement in power of detection from 6- to 202-fold for 17 elements (Ag, As, Au, Bi, Cd, Cu, Hg, In, K, Pb, Pd, Rb, Sb, Se, Te, Tl, Zn). A standard deviation of 1.7-4.0% (n = 12, 50 microL) was achieved. Sample volumes between 10 microL and 1 mL have been investigated. For 50 microL sample volumes, the sampling frequency is 4/min. The new method can also be considered a simple, effective interface between HPLC and flame AAS.
The ability to mix aqueous liquids on microsecond time scales, while consuming minimal amounts of sample and maintaining UV-visible optical access to the mixing region, is highly desirable for a range of biophysical studies of fast protein and nucleic acid interactions and folding. We have constructed a laminar coaxial jet mixer that allows the measurement of UV-excited fluorescence from nanoliter and microliter quantities of material, mixed at microsecond rates. The mixer injects a narrow cylindrical stream (radius a < 1 microm) of fluorescent sample into a larger flow of diluting buffer that moves through a capillary (100 microm i.d.) at a speed approximately 20 cm/s, under laminar flow conditions (Re approximately equal to 14). Construction from a fused silica capillary allows the laser excitation (at 266 nm) and detection (at 350 nm) of tryptophan fluorescence at reasonably low working concentrations, without interference from background fluorescence. Using this mixer we have measured sub-millisecond fluorescence quenching kinetics while consuming fluorescent sample at rates no greater than 6 nl/s. Consumption of the diluting buffer is also very modest (approximately 1-3 microl/s) in comparison with other rapid mixer designs.
Explore the source record for details and available documents.
This paper presents a physical evaluation of an upflow anaerobic sludge blanket reactor. Specifically, the study contemplates the region influenced by the wastewater inlet jets at the bottom of the reactor, here termed the near-field area. A three-dimensional physical model of a UASB reactor in reduced scale, geometrically and dynamically correlated to a full-scale prototype was used in the evaluation. From the analysis of the major forces acting and of the physical properties investigated in the prototype, it was possible to establish non-dimensional relations that were applied to the reduced scale model, allowing the investigation of the phenomenon of interest. Tests were developed on the model to visualise the inlet flows under the buoyant effect at the bottom of the reactor, through the injection of a tracer fluid in the area with higher density, simulating the effects of the sludge bed. Based on the experimental results, it was possible to provide dimensioning criteria for the jet distribution system in UASB reactors.