Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “INTERFEROMETRY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52Linked to original sources

Effect of trabeculectomy on ocular blood flow.

BACKGROUND/AIM: Current evidence suggests that vascular insufficiencies in the optic nerve head play an important part in the pathogenesis of glaucomatous optic neuropathy. Trabeculectomy is the most common operative procedure for the treatment of medically uncontrolled glaucoma. This study was conducted to investigate whether trabeculectomy may improve ocular haemodynamics. METHODS: 30 patients with primary open angle glaucoma about to undergo trabeculectomy were included in the study. Patients were evaluated before surgery and at 2 and 10 weeks after trabeculectomy. Optic nerve head blood flow (OnhBF) was assessed with scanning laser Doppler flowmetry. Fundus pulsation amplitude (FPA) measurements were obtained with laser interferometry. RESULTS: Because of the decrease in intraocular pressure there was a significant increase in ocular perfusion pressure (OPP) following trabeculectomy (18.5% (SD 12.0%) and 19.0% (17.1%) at 2 and 10 weeks postoperatively; p <0.001). A significant increase in OnhBF was observed after trabeculectomy (11.6% (16.4%) and 16.2% (20.2%) for each postoperative visit, respectively; p <0.001). FPA was also significantly higher compared with baseline values (17.2% (17.3%) and 17.4% (16.3%), respectively; p <0.001). A significant association between the increase in OPP and the increase in OnhBF and FPA was observed 10 weeks after surgery (r = 0.47; p = 0.009, and r = 0.50; p = 0.005, respectively). CONCLUSION: The results of this study suggest that trabeculectomy improves ocular blood flow in patients with chronic open angle glaucoma.

Aged↗

A new non-contact optical device for ocular biometry.

BACKGROUND: A new commercially available device (IOLMaster, Zeiss Instruments) provides high resolution non-contact measurements of axial length (using partial coherent interferometry), anterior chamber depth, and corneal radius (using image analysis). The study evaluates the validity and repeatability of these measurements and compares the findings with those obtained from instrumentation currently used in clinical practice. METHOD: Measurements were taken on 52 subjects (104 eyes) aged 18-40 years with a range of mean spherical refractive error from +7.0 D to -9.50 D. IOLMaster measurements of anterior chamber depth and axial length were compared with A-scan applanation ultrasonography (Storz Omega) and those for corneal radius with a Javal-Schiötz keratometer (Topcon) and an EyeSys corneal videokeratoscope. RESULTS: Axial length: the difference between IOLMaster and ultrasound measures was insignificant (0.02 (SD 0.32) mm, p = 0.47) with no bias across the range sampled (22.40-27.99 mm). Anterior chamber depth: significantly shorter depths than ultrasound were found with the IOLMaster (-0.06 (0.25) mm, p <0.02) with no bias across the range sampled (2.85-4.40 mm). Corneal radius: IOLMaster measurements matched more closely those of the keratometer than those of the videokeratoscope (mean difference -0.03 v -0.06 mm respectively), but were more variable (95% confidence 0.13 v 0.07 mm). The repeatability of all the above IOLMaster biometric measures was found to be of a high order with no significant bias across the measurement ranges sampled. CONCLUSIONS: The validity and repeatability of measurements provided by the IOLMaster will augment future studies in ocular biometry.

Adult↗

Blood vessels: depiction at phase-contrast X-ray imaging without contrast agents in the mouse and rat-feasibility study.

The ability of phase-contrast x-ray imaging to depict blood vessels without contrast agents was tested by observing livers of a mouse and a rat with synchrotron x rays. Livers were excised by tying arteries and veins to prevent blood from flowing out of the liver. An x-ray interferometer was used to obtain x-ray phase contrast. With the technique of phase-shifting x-ray interferometry, the image mapping x-ray phase shift caused by a liver was measured. The x-ray phase shift caused by blood was substantially different from that caused by other soft tissues; consequently, trees of blood vessels were revealed on the image. Vessels with diameter smaller than 0.1 mm were recognized. This result allows new possibilities for investigation of the vascular system.

Angiography↗

Effect of histamine and cimetidine on retinal and choroidal blood flow in humans.

Intravenous administration of histamine causes an increase in choroidal blood flow and retinal vessel diameter in healthy subjects. The mechanism underlying this effect remains to be elucidated. In the present study, we hypothesized that H2 receptor blockade alters hemodynamic effects of histamine in the choroid and retina. Eighteen healthy male nonsmoking volunteers were included in this randomized, double-masked, placebo-controlled two-way crossover study. Histamine (0.32 microg.kg(-1).min(-1) over 30 min) was infused intravenously in the absence (NaCl as placebo) or presence of the H2 blocker cimetidine (2.3 mg/min over 50 min). Ocular hemodynamic parameters, blood pressure, and intraocular pressure were measured before drug administration, after infusion of cimetidine or placebo, and after coinfusion of histamine. Subfoveal choroidal blood flow and fundus pulsation amplitude were measured with laser-Doppler flowmetry and laser interferometry, respectively. Retinal arterial and venous diameters were measured with a retinal vessel analyzer. Retinal blood velocity was assessed with bidirectional laser-Doppler velocimetry. Histamine increased subfoveal choroidal blood flow (+14 +/- 15%, P < 0.001), fundus pulsation amplitude (+11 +/- 5%, P < 0.001), retinal venous diameter (+3.0 +/- 3.6%, P = 0.002), and retinal arterial diameter (+2.8 +/- 4.2%, P < 0.01) but did not change retinal blood velocity. The H2 antagonist cimetidine had no significant effect on ocular hemodynamic parameters. In addition, cimetidine did not modify effects of histamine on choroidal blood flow, fundus pulsation amplitude, retinal venous diameter, and retinal arterial diameter compared with placebo. The present data confirm that histamine increases choroidal blood flow and retinal vessel diameters in healthy subjects. This ocular vasodilator effect of histamine is, however, not altered by administration of an H2 blocker. Whether the increase in blood flow is mediated via H1 receptors or other hitherto unidentified mechanisms remains to be elucidated.

Adult↗

Free fatty acids/triglycerides increase ocular and subcutaneous blood flow.

Elevated plasma free fatty acids (FFA) induce skeletal muscle insulin resistance and impair endothelial function. The aim of this study was to characterize the acute hemodynamic effects of FFA in the eye and skin. A triglyceride (Intralipid 20%, 1.5 ml/min)/heparin (bolus: 200 IU; constant infusion rate: 0.2 IU. kg(-1). min(-1)) emulsion or placebo was administered to 10 healthy subjects. Measurements of pulsatile choroidal blood flow with laser interferometry, retinal blood flow with the blue field entoptic technique, peak systolic and end diastolic blood velocity (PSV, EDV) in the ophthalmic artery with Doppler sonography, and subcutaneous blood flow with laser Doppler flowmetry were performed during an euglycemic somatostatin-insulin clamp over 405 min. Plasma FFA/triglyceride elevation induced a rise in pulsatile choroidal blood flow by 25 +/- 3% (P < 0.001) and in retinal blood flow by 60 +/- 23% (P = 0.0125). PSV increased by 27 +/- 8% (P = 0.001), whereas EDV was not affected. Skin blood flow increased by 149 +/- 38% (P = 0.001). Mean blood pressure and pulse rate remained unchanged, whereas pulse pressure amplitude increased by 17 +/- 5% (P = 0.019). Infusion of heparin alone had no hemodynamic effect in the eye or skin. In conclusion, FFA/triglyceride elevation increases subcutaneous and ocular blood flow with a more pronounced effect in the retina than in the choroid, which may play a role for early changes of ocular perfusion in the insulin resistance syndrome.

Adult↗

Mechanical response characteristics of the hearing organ in the low-frequency regions of the cochlea.

1. With the use of an in vitro preparation of the guinea pig temporal bone, in which the apical turns of the cochlea are exposed, the mechanical and electrical responses of the cochlea in the low-frequency regions were studied during sound stimulation. 2. The mechanical characteristics were investigated in the fourth and third turns of the cochlea with the use of laser heterodyne interferometry, which allows the vibratory responses of both sensory and supporting cells to be recorded. The electrical responses, which can be maintained for several hours, were recorded only in the most apical turn. 3. In the most apical turn, the frequency locations and shapes of the mechanical and electrical responses were very similar. 4. The shapes of the tuning curves and the spatial locations of the frequency maxima in the temporal bone preparation compared very favorably with published results from in vivo recordings of hair cell receptor potentials and sound-induced vibrations of the Reissner's membrane. 5. Compressive nonlinearities were present in both the mechanical and the electrical responses at moderate sound pressure levels. 6. The mechanical tuning changed along the length of the cochlea, the center frequencies in the fourth and third turns being approximately 280 and 570 Hz, respectively. 7. The mechanical responses of sensory and supporting cells were almost identical in shape but differed significantly in amplitude radially across the reticular lamina.

Acoustic Stimulation↗

Imaging of the oral cavity using optical coherence tomography.

Optical coherence tomography is a new method for noninvasively imaging internal tooth and soft tissue microstructure. The intensity of backscattered light is measured as a function of depth in the tissue. Low coherence interferometry is used to selectively remove the component of backscattered signal that has undergone multiple scattering events, resulting in very high resolution images (< 15 microns). Lateral scanning of the probe beam across the biological tissue is then used to generate a 2-D intensity plot, similar to ultrasound images. This imaging method provides information that is currently unobtainable by any other means, making possible such diverse applications as diagnosis of periodontal disease, caries detection, and evaluation of restoration integrity. This chapter presents an overview of this exciting new imaging technique and its current application to dental diagnosis.

Dental Caries↗

Interferometric laser holography for determination of the localization and extent of bladder tumor.

In male giant rabbits (n = 10) with and without bladder carcinomas, holographic interferometric investigations with a double impulse rubin laser were made for testing the sensitivity of this method in detection of elasticity changes of the bladder wall caused by tumors. It could be shown that the holographic interferometry enables a distinction to be made between healthy and tumorous regions of the bladder wall by the various interference patterns.

Animals↗

Low-temperature growth of nanostructured diamond films.

Nanostructured diamond films are grown on a titanium alloy substrate using a two-step deposition process. The first step is performed at elevated temperature (820 degrees C) for 30 min using a H2/CH4/N2 gas mixture to grow a thin (approximately 600 nm) nanostructured diamond layer and to improve film adhesion. The remainder of the deposition involves growth at low temperature (< 600 degrees C) in a H2/CH4/O2 gas mixture. The continuation of the smooth nanostructured diamond film growth during low-temperature deposition is confirmed by in situ laser reflectance interferometry, atomic force microscopy, micro-Raman spectroscopy, and surface profilometry. Similar experiments performed without the initial nanostructured diamond layer resulted in poorly adhered films with a more crystalline appearance and a higher surface roughness. This low-temperature deposition of nanostructured diamond films on metals offers advantages in cases where high residual thermal stress leads to delamination at high temperatures.

Adsorption↗

Effects of adenosine on intraocular pressure, optic nerve head blood flow, and choroidal blood flow in healthy humans.

PURPOSE: There is evidence from a variety of animal studies that the adenosine system plays a role in the control of intraocular pressure (IOP) and ocular blood flow. However, human data on the effect of adenosine on IOP and choroidal and optic nerve blood flow are not available. METHODS: The effect of stepwise increases in doses of adenosine (10, 20, and 40 micro g/kg per minute, 30 minutes per infusion step) on optic nerve head blood flow, choroidal blood flow, and IOP was determined in a placebo-controlled double-masked clinical trial in 12 healthy male volunteers. Blood flow in the optic nerve head and choroid was measured with laser Doppler flowmetry. In addition, fundus pulsation amplitude in the macula (FPAM) and the optic nerve head (FPAO) were assessed with laser interferometry. RESULTS: Adenosine induced a small but significant decrease in IOP (at 40 microg/kg per minute: 12% +/- 13%), which was significant versus placebo (P = 0.046). In addition, adenosine induced a significant increase in choroidal blood flow (P < 0.001) and optic nerve head blood flow (P = 0.037), and FPAM (P = 0.0014) and tended to increase FPAO (P = 0.057). At the highest administered dose, the effect on choroidal hemodynamic parameters between 14% and 17%, whereas the effect on optic nerve hemodynamic parameters was between 3% and 11%. CONCLUSIONS: These data are consistent with adenosine inducing choroidal and optic nerve head vasodilatation and reducing IOP in healthy humans. Considering the neuroprotective properties of adenosine described in previous animal experiments the adenosine system is an attractive target system for therapeutic approaches in glaucoma.

Adenosine↗

Diurnal axial length fluctuations in human eyes.

PURPOSE: This study sought diurnal variations of eye length in human subjects, analogous to those reported in laboratory animals. METHODS: Seventeen subjects, ages 7 to 53 (median 16) years and mean spherical equivalent refractive error -0.68 D (range, -3.00 to +1.00 D), underwent axial length measurements at multiple times during the day between 7 AM and 1 AM the following day, using partial coherence interferometry (PCI), a highly precise, noncontact method. Diurnal axial length measurements were obtained on two or more days in 10 of these subjects. RESULTS: During at least 1 day, 15 subjects showed a statistically significant (ANOVA, P < 0.05) diurnal fluctuation of axial length, with a magnitude generally between 15 and 40 microm. From the diurnal tracings that fit a sine curve using statistical criteria, the mean period of fluctuation was 21.6 +/- 4.33 hours (SD), the mean amplitude was 27.1 +/- 11.9 microm (SD; range, 12.8-41.4 microm), and the maximum axial length tended to occur at midday. Each of the subjects with multiple daily measurements showed axial length fluctuations on at least 1 day, but there were day-to-day differences in the diurnal variations: most notably, four subjects showed axial length fluctuations on each day; in others, the fluctuations were not observed on each testing day. CONCLUSIONS: The human eye undergoes diurnal fluctuations in axial length, with a pattern suggesting maximum axial length at midday. Based on repeated measurements, these daily fluctuations may not appear regularly in all subjects, suggesting the possibility of physiologic influences that must be defined.

Adolescent↗

Intravenously administered histamine increases choroidal but not retinal blood flow.

PURPOSE: To determine the effect of intravenously administered histamine on both retinal and choroidal blood flow in humans. METHODS: A randomized, double-masked, two-way crossover study was performed in 14 healthy volunteers. Placebo or histamine was administered intravenously in stepwise increasing doses (0.08 microg/kg/min, 0.16 microg/kg/min, and 0.32 microg/kg/min). Retinal vessel diameters were measured with a retinal vessel analyzer, and retinal venous blood speed was assessed by bi-directional laser Doppler velocimetry. Using these parameters retinal blood flow was calculated. Subfoveal and pulsatile choroidal blood flow were measured with laser Doppler flowmetry and laser interferometry, respectively. RESULTS: After infusion of histamine pulsatile choroidal blood flow increased by 5 +/- 3%, 9 +/- 8%, and 14 +/- 7% (P = 0.001, ANOVA) and subfoveolar choroidal blood flow by 8 +/- 11%, 13 +/- 11%, and 13 +/- 12% (P = 0.003, ANOVA). Retinal arterial and venous vessel diameter significantly increased by 3 +/- 4%, 2 +/- 4%, and 3 +/- 5% (P = 0.047, ANOVA) and 1 +/- 2%, 3 +/- 2%, and 3 +/- 2% (P = 0.015, ANOVA), respectively. Red blood cell velocity in major retinal veins tended to decrease by -9 +/- 12%, -9 +/- 20%, and -13 +/- 12%, but this effect did not reach levels of significance. Calculated retinal blood flow was not changed by administration of histamine (-7 +/- 14%, -4 +/- 20%, and -8 +/- 12%, P = 0.28, ANOVA). CONCLUSIONS: Intravenous histamine in the selected doses increased choroidal blood flow. Retinal vessels showed a small diameter increase, whereas red blood cell speed decreased, resulting in an unchanged total retinal blood flow. This may result from local differences in the receptor distribution in the posterior part of the eye.

Adult↗

Thinning rate of the precorneal and prelens tear films.

PURPOSE: To apply interferometry as an in vivo measure of tear film thinning between blinks. METHODS: Wavelength-dependent interference was used to measure the tear film thinning rates in 20 normal contact lens wearers, and spectra were captured at a rate of 4.5 per second for 20 seconds. Four recordings of precorneal tear film (PCTF) thinning were made, followed by 1 hour of hydrogel lens wear and then four recordings of prelens tear film (PLTF) thinning. Subjects were asked to blink 1 second after the beginning of the recording and then hold their eyes open for an additional 19 seconds, followed by 2 minutes of rest between recordings. RESULTS: The average thinning rate of the PLTF was greater than that of the PCTF and average initial tear film thickness of the PLTF was less than that of the PCTF. For both these reasons, the "tear thinning time" (time to reach 0 thickness) was typically shorter for the PLTF than for the PCTF. Histograms of PCTF and PLTF thinning rates showed a narrow peak corresponding to slow thinning of approximately 1 microm/min, but also many examples of rapid thinning of approximately 10 microm/min, with greater variability. Both the initial thickness and thinning rate of the PLTF correlated with corresponding values for the PCTF, although many more rapidly changing values were associated with the PLTF. Plots of rapid thinning of PCTF and PLTF were both linear and were not accompanied by any significant increase in thickness of corneal epithelium or contact lens, respectively. CONCLUSIONS: Tear film thinning can be analyzed in terms of flow in three spatial directions: (1) outward (evaporation), (2) inward (into the epithelium or contact lens), and (3) parallel to the tear film surface. The results indicate that the second mechanism may be unimportant. Studies have shown a range of tear film evaporation rates from 0.24 to 1.45 microm/min, whereas, when the lipid layer is washed away from the tear film, the thinning rate, due to evaporation, would be approximately 7 microm/min. Thus, slow thinning rates may be due to tear film evaporation, whereas rapid rates (which are often greater than 7 microm/min) presumably include other mechanisms such as dewetting, Marangoni flow (i.e., surface tension gradients), and pressure-gradient flow.

Adult↗

The relation of axial length and intraocular pressure fluctuations in human eyes.

PURPOSE: To determine in human eyes whether diurnal fluctuations in axial length are related to fluctuations in intraocular pressure (IOP) by studying these fluctuations in both eyes of individual subjects and by assessing the regularity of both rhythms on two separate study days. METHODS: Ten subjects, ages 18 to 24 years, underwent serial axial length and IOP measurements using highly precise, noncontact partial coherence interferometry and Goldmann applanation tonometry, respectively. Both eyes were measured at six 3-hour intervals during each of two study days, and significant fluctuations were modeled by sine curves. RESULTS: Of the 40 data sets, 29 had significant axial length high-low differences and 32 had significant IOP high-low differences (ANOVA, P < 0.05 for each). The magnitude of the significant high-low differences were 38 +/- 22 microm for axial length and 6.0 +/- 1.9 mm Hg for IOP (mean +/- SD). Neither axial length nor IOP fluctuations necessarily occurred bilaterally on the same day, and neither rhythm was regularly observed on two separate days in individual eyes. In eyes in which both parameters fluctuated on the same day, there were no correlations in the amplitude, period or phase of the two rhythms. CONCLUSIONS: Both axial length and IOP fluctuate during the day much of the time in most subjects. However, diurnal IOP fluctuations do not appear to cause diurnal axial length fluctuations.

Adolescent↗

Heritability of refractive error and ocular biometrics: the Genes in Myopia (GEM) twin study.

PURPOSE: A classic twin study was undertaken to assess the contribution of genes and environment to the development of refractive errors and ocular biometrics in a twin population. METHODS: A total of 1224 twins (345 monozygotic [MZ] and 267 dizygotic [DZ] twin pairs) aged between 18 and 88 years were examined. All twins completed a questionnaire consisting of a medical history, education, and zygosity. Objective refraction was measured in all twins, and biometric measurements were obtained using partial coherence interferometry. RESULTS: Intrapair correlations for spherical equivalent and ocular biometrics were significantly higher in the MZ than in the DZ twin pairs (P < 0.05), when refraction was considered as a continuous variable. A significant gender difference in the variation of spherical equivalent and ocular biometrics was found (P < 0.05). A genetic model specifying an additive, dominant, and unique environmental factor that was sex limited was the best fit for all measured variables. Heritability of spherical equivalents of 88% and 75% were found in the men and women, respectively, whereas, that of axial length was 94% and 92%, respectively. Additive genetic effects accounted for a greater proportion of the variance in spherical equivalent, whereas the variance in ocular biometrics, particularly axial length was explained mostly by dominant genetic effects. CONCLUSIONS: Genetic factors, both additive and dominant, play a significant role in refractive error (myopia and hypermetropia) as well as in ocular biometrics, particularly axial length. The sex limitation ADE model (additive genetic, nonadditive genetic, and environmental components) provided the best-fit genetic model for all parameters.

Adolescent↗

Intraoperative assessment of stapes movement.

A method is described that allows, for the first time, intraoperative vibration modes assessment of the acoustically stimulated stapes by means of scanning laser Doppler interferometry (LDI). The study was designed to answer the following questions: 1) Is LDI practical for taking measurements during surgery? 2) Are the results comparable to the findings in temporal bone preparations? and 3) Do the vibration characteristics of the stapes change after the posterior incudal ligament is detached from the incus? Seven patients with profound bilateral hearing loss who were undergoing cochlear implantation were included in the study. The measurement system was easily applicable for intraoperative measurements and allowed contact-free analysis with very high accuracy. No major differences in the results from the live human subjects and temporal bone preparations were observed. The stapes movement was predominantly pistonlike at the lower frequencies and became complex at higher frequencies. Sacrificing the posterior incudal ligament had no statistically significant effect on stapes vibration.

Acoustic Stimulation↗

Mass loading on the ossicles and middle ear function.

The middle ear as a levered vibrating system for sound transmission from the external to the inner ear is affected by changes in ossicular chain mass. Mass loading of the ossicles may impair ossicular dynamics and sound transmission to the inner ear. It is incumbent on otologic surgeons and researchers of middle ear mechanics to consider the mass loading effect on middle ear function in clinical and physiological applications. The residual hearing and frequency response can change after surgery or implantation of middle ear prostheses. We conducted experiments on mass loading effects on the middle ear transfer functions by using laser Doppler interferometry and a human temporal bone model. Two implant mass loading conditions were tested on 17 fresh or fresh-frozen temporal bones and compared with the unloaded condition for the frequencies 250 to 8,000 Hz. The results show that the linearity of the middle ear function did not change, although displacement of the stapes footplate decreased after the increased masses were placed on the incudostapedial joint. The greater the mass of the implant, the less displacement was measured at the stapes footplate. We conclude that there is a quantitative limit to increased mass on the ossicular chain above which the mass will remarkably impair hearing thresholds.

Adult↗

Fixation of the anterior mallear ligament: diagnosis and consequences for hearing results in stapes surgery.

In the search for possible causes of unfavorable results after stapes surgery, the study reported here focused on the anterior mallear ligament, since it has been previously reported that partial mallear fixation (PMF) leads to functional failure in 38% of cases of stapes revision surgery. The aims of the study were to identify effective methods for the diagnosis of PMF and experimentally assess the conductive hearing loss that results from PMF. The study included vibration amplitude measurements of the ossicles by laser Doppler interferometry (LDI) in 19 patients and 5 fresh human temporal bone (TB) specimens. Analysis of their dynamic behavior was performed by finite element modeling (FEM). Similar, significant changes of manubrium vibration patterns for PMF were found by FEM calculations, in TB experiments, and in patients. We could identify PMF either before operation, using LDI, or during operation, by manual palpation. In the TB experiments and FEM calculations, the attenuation of the stapes displacement due to an isolated PMF was approximately 10 dB and frequency-dependent. Untreated anterior mallear ligament fixation produced a persistent air-bone gap of approximately 10 dB after stapedioplasty.

Acoustic Impedance Tests↗