Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AUSCULTATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52Linked to original sources

Do clinical findings in lower respiratory tract infection help general practitioners prescribe antibiotics appropriately? An observational cohort study in general practice.

BACKGROUND: Antibiotics are over-prescribed for lower respiratory tract infection (LRTI). The influence of clinicians' history and examination findings on antibiotic prescribing for LRTI has not been directly assessed, and the extent to which these clinical findings predict appropriate antibiotic prescribing is unknown. A clearer understanding is crucial to achieving evidence-based prescribing. OBJECTIVES: To directly assess the influence of general practitioners' history and examination findings on antibiotic prescribing for LRTI, and to explore the extent to which these clinical findings predict appropriate antibiotic prescribing. METHODS: In this observational cohort study 25 GPs in The Netherlands were recruited during routine consultations and 247 adult patients with a clinical diagnosis of LRTI. The GPs recorded clinical information. Odds ratios (ORs) with 95% confidence intervals (CIs) for clinical variables predicting a prescription for an antibiotic were calculated. The relationship between antibiotic prescription and radiographic evidence of pneumonia was explored in order to gauge appropriateness of antibiotic prescribing. RESULTS: Auscultation abnormalities (OR 11.5; 95% CI 5.4-24.7), and diarrhoea (OR>11) were strongly associated with antibiotic prescribing. An antibiotic was prescribed for 195 (79%) patients. Assuming that an antibiotic definitely needs to be prescribed only for patients with pneumonia, antibiotics may have been inappropriately prescribed for 166/193 (86%) of the patients. Antibiotics were not prescribed for 5 of the 32 (16%) patients with a radiographic diagnosis of pneumonia. CONCLUSIONS: Abnormal findings on auscultation in patients with LRTI strongly predict antibiotic prescribing and this is probably inappropriate for most patients. These results should prompt GPs to consider the extent to which finding 'crackles/rhonchi on auscultation' influences their decisions to prescribe antibiotics for their patients with LRTI, and to consider the predictive value of individual clinical signs in reaching evidence-based prescribing decisions.

Adolescent↗

Incorporating simulators in a standardized patient exam.

OBJECTIVE: Using simulated patients during a clinical skills exam that involves many students has the advantage of standardizing the delivery of historical data. One major disadvantage is the inability to standardize the physical exam findings. We designed a simulated patient exam that incorporates simulated abnormal physical exam findings. DESCRIPTION: The simulated patient exam case was divided into three separate stations: (1) the simulated patient's history, (2) the simulated physical exam, and (3) the presentation station. Dyspnea was chosen as the chief complaint because of the broad differential of possible cardiac and pulmonary auscultatory findings. In the first station, students obtained historical data from the standardized simulated patient. Students were graded on their ability to ask appropriate historical questions. Trained observers were used to verify the numbers of historical cues obtained by the students. The second station consisted of simulated physical exam findings. Students first measured the blood pressure on a commercially available blood pressure simulator arm from the Medical Plastics Laboratory, Inc., Gatesville, TX. Students then auscultated an abnormal digital heart sound and pulmonary sound from a small auscultation transducer developed by Andries Acoustics, Spicewood, TX. Students also palpated a simulated pulse from a newly developed pulse transducer. Digital cardiopulmonary sounds and pulse data were recorded onto a CD-ROM disc and transmitted to the small transducers via a CD-ROM disc player. Students used their own stethoscopes to auscultate cardiopulmonary sounds from the small transducers. The students were graded in the second station on their ability to accurately measure a blood pressure, identify abnormal cardiopulmonary digital sounds, and finally describe a peripheral pulse. In the third station, students presented the historical data and physical exam findings to a faculty member, and then provided a differential diagnosis list based on their key findings from the other two stations. A total of 171 students (n = 171) completed the simulated patient exam. Each student completed the exam in 45 minutes. DISCUSSION: In our simulated patient exam, students were evaluated not only on their data-gathering skills for key historical findings but also on the ability to correctly identify key physical exam findings such as abnormal cardiopulmonary sounds. Key physical exam findings were then integrated into the clinical decision-making process, which was presented in the faculty presentation station. Simulated patients with abnormal cardiopulmonary findings can be used for testing purposes. However, cardiac auscultatory abnormalities such as the ventricular S3 gallop are difficult to find and usually occur in a decompensated state such as heart failure. Other physical exam findings such as pulmonary crackles and wheezes also occur in decompensated conditions. Therefore, the use of simulators during a simulated patient exam offers the possibility of introducing several abnormal physical exam findings without having an unstable patient present in an exam setting. Further, the use of simulated physical exam findings allows for complete standardization of a clinical-simulated patient exam.

Clinical Competence↗

Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.

OBJECT: Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. METHOD: The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. RESULTS: There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar dorsiflexion was significantly lower than that in palmar extension. In some cases, finger plethysmogram did not disappear during maximum inflation of the wrist-cuff (congruent with 250 mmHg), even in palmar extension and especially in palmar flexion, suggesting incomplete obstruction of radial and/or ulnar arteries during inflation. CONCLUSION: The results suggest that wrist-cuff devices in the present form are inadequate for self-measurement of blood pressure and, thus, are inadequate for general use or clinical and practical use. However, there is much possibility in wrist-cuff device and the accuracy and reliability of wrist-cuff device are warranted by an improvement of technology.

Adolescent↗

Prospective evaluation of the sensitivity of physical examination in chest trauma.

BACKGROUND: Chest radiographs are routine for patients presenting with blunt and penetrating chest trauma. The accuracy of physical examination in the diagnosis of hemopneumothorax in these patients is unclear. A prospective study was performed to define the utility of routine portable chest radiographs in 676 trauma patients. METHODS: Over 19 months (January 2000-July 2001), 676 patients who presented with penetrating or blunt chest trauma were interviewed and examined for signs and symptoms of hemopneumothorax. The incidence of chest pain or tenderness and tachypnea was noted and both lung fields were auscultated. A portable chest radiograph was then performed on all the patients. RESULTS: All the patients were hemodynamically stable. Five hundred twenty-three patients sustained blunt trauma, with seven hemopneumothoraces (1.3%). The negative predictive values of auscultation, pain or tenderness, and tachypnea were 99& to 100%. One hundred fifty-three patients sustained penetrating chest trauma. Of these injuries, 68 were gunshot wounds and 85 were stab wounds. Twenty-four (16%) of these patients had hemopneumothoraces. The sensitivities of auscultation, pain or tenderness, and tachypnea were 50%, 25%, and 32%, respectively. The negative predictive values of these tests were < 91%. CONCLUSION: Blunt chest trauma patients who are hemodynamically stable with a normal physical examination do not require a routine chest radiograph. In contrast, all victims of penetrating trauma require chest radiographs because many will have hemopneumothorax in the absence of clinical findings.

Adolescent↗

Intrapartum electronic fetal heart rate monitoring and the prevention of perinatal brain injury.

OBJECTIVE: Electronic fetal heart rate monitoring (EFM) is the most widely used method of intrapartum surveillance, and our objective is to review its ability to prevent perinatal brain injury and death. DATA SOURCES: Studies that quantified intrapartum EFM and its relation to specific neurologic outcomes (seizures, periventricular leukomalacia, cerebral palsy, death) were eligible for inclusion. MEDLINE was searched from 1966 to 2006 for studies that examined the relationship between intrapartum EFM and perinatal brain injury using these MeSH and text words: "cardiotocography," "electronic fetal monitoring," "intrapartum fetal heart rate monitoring," "intrapartum fetal monitoring," and "fetal heart rate monitoring." METHODS OF STUDY SELECTION: This search strategy identified 1,628 articles, and 41 were selected for further review. Articles were excluded for the following reasons: in case reports, letters, commentaries, and review articles, intrapartum EFM was not quantified, or specific perinatal neurologic morbidity was not measured. Three observational studies and a 2001 meta-analysis of 13 randomized controlled trials were selected for determination of the effect of intrapartum EFM on perinatal brain injury. TABULATION, INTEGRATION, AND RESULTS: Electronic fetal monitoring was introduced into widespread clinical practice in the late 1960s based on retrospective studies comparing its use to historical controls where auscultation was performed in a nonstandardized manner. Case-control studies have shown correlation of EFM abnormalities with umbilical artery base excess, but EFM was not able to identify cerebral white matter injury or cerebral palsy. Of 13 randomized controlled trials, one showed a significant decrease in perinatal mortality with EFM compared with auscultation. Meta-analysis of the randomized controlled trials comparing EFM with auscultation have found an increased incidence of cesarean delivery and decreased neonatal seizures but no effect on the incidence of cerebral palsy or perinatal death. CONCLUSION: Although intrapartum EFM abnormalities correlate with umbilical cord base excess and its use is associated with decreased neonatal seizures, it has no effect on perinatal mortality or pediatric neurologic morbidity.

Birth Injuries↗

Clinical findings in cattle with dilatation and torsion of the caecum.

Dilatation and torsion of the caecum is usually an acute illness with signs of ileus and this paper presents the clinical findings from 111 heifers and cows with the condition. On admission 61 per cent of the animals had been ill for less than 24 hours; the general condition was disturbed in 58 per cent of the animals, 39 per cent showed signs of colic; the rectal temperature was abnormal in 55 per cent, the heart rate in 40 per cent and the respiration rate in 52 per cent of the animals; rumen motility was reduced or absent in 85 per cent. One or more tests for foreign bodies were positive in 58 per cent, and swinging auscultation and percussion auscultation on the right side, either alone or in combination, were positive in 83 per cent of the animals. On rectal examination it was possible to palpate a pathologically distended, displaced or twisted caecum in 95 per cent of the animals. In 87 per cent defecation was reduced or absent. The most reliable diagnostic investigations were rectal examination and swinging and percussion auscultation on the right side.

Animals↗

Acoustic signature of the normal swallow: characterization by age, gender, and bolus volume.

Despite growing clinical use, cervical auscultation suffers from a lack of research-based data. One of the strongest criticisms of cervical auscultation is that there has been little research to demonstrate how dysphagic swallowing sounds are different from normal swallowing sounds. In order to answer this question, however, one first needs to document the acoustic characteristics of "normal," nondysphagic swallowing sounds. This article provides the first normative database of normal swallowing sounds for the adult population. The current investigation documents the acoustic characteristics of normal swallowing sounds for individuals from 18 to more than 60 years of age over a range of thin liquid volumes. Previous research has shown the normal swallow to be a dynamic event. The normal swallow is sensitive to aging of the oropharyngeal system, and also to the volume of bolus swallowed. The current investigation found that the acoustic signals generated during swallowing were sensitive to an individual's age and to the volume of the bolus swallowed. There were also some gender-specific differences in the acoustic profile of the swallowing sound. It is anticipated that the results will provide a catalyst for further research into cervical auscultation.

Acoustics↗

Colorimetric end-tidal carbon dioxide monitoring for tracheal intubation.

We evaluated a colorimetric end-tidal carbon dioxide (ETCO2) detector (FEF end-tidal carbon dioxide detector, Fenem, New York, N.Y.) during 62 intubations in anesthetized patients who were hemodynamically stable. The intubations were performed during a drill that simulates difficult tracheal intubation and therefore is associated with an increased risk of esophageal intubation. Each intubation attempt was monitored by two anesthesiologists and a research assistant who together used chest auscultation, colorimetric ETCO2, and capnography to confirm tracheal intubation and detect esophageal intubation. The reliability of the monitors was compared with capnography. Colorimetric ETCO2 confirmed tracheal intubations and detected esophageal intubations 100% of the time, as judged by capnography. There were no false-positive or false-negative decisions based on endotracheal tube position; however, one equivocal color change occurred, which was caused by failure to inflate the endotracheal tube cuff. Colorimetric ETCO2 monitoring confirmed tracheal intubation more rapidly than did chest auscultation (P less than 0.001) or capnography (P less than 0.05), and detected esophageal intubation more rapidly than did chest auscultation (P less than 0.05) and as rapidly as capnography did. Confirmation of tracheal intubation was achieved earlier than detection of esophageal intubation with all three monitors (P less than 0.05). We conclude that colorimetric ETCO2 monitoring is a safe, reliable, rapid, simple, and portable method for determining endotracheal tube position for patients who are hemodynamically stable and should be recommended where capnography is not available.

Carbon Dioxide↗

Adenosine bronchial provocation with computerized wheeze detection in young infants with prolonged cough: correlation with long-term follow-up.

BACKGROUND: Chronic cough in babies is often associated with bronchial hyperreactivity (BHR). The objective documentation of BHR in babies is difficult, and acoustic methods have been described (provocative concentration of a substance causing wheeze) for conducting bronchial provocation tests (BPTs). We conducted a study to evaluate automatic computerized wheeze detection (CWD) in determining BHR in young infants with prolonged cough, and its correlation with the subsequent development of wheezing. METHODS: Infants aged < 24 months with prolonged cough (ie, > 2 months) underwent acoustic BPTs with the response determined by CWD and auscultation by a physician. Telephone interviews with parents were conducted after 1 month and yearly for the next 3 years. RESULTS: A total of 28 infants who were 4 to 24 months old with prolonged cough were included in the study. Twenty of these infants (71.4%) had BHR as determined by a positive acoustic BPT result. In 11 of these 20 tests, the CWD occurred earlier, and in 9 tests it occurred at the same step as auscultation by a physician. Rhonchi or whistles often preceded wheezes. Seventeen of the 20 patients with BHR completed 3 years of follow-up. Of these, 14 had recurrent episodes of wheezing and shortness of breath, and 3 were well. Six of the eight adenosine-negative patients completed 3 years of follow-up and had no symptoms of BHR. CONCLUSIONS: Acoustic BPT is a technically feasible test for the detection of BHR in young infants. CWD provides an earlier detection of wheeze than stethoscope auscultation. In our group of infants, a positive acoustic BPT result had high correlation with symptoms compatible with BHR over the next 3 years.

Acoustics↗

Wavelet processing of systolic murmurs to assist with clinical diagnosis of heart disease.

Despite advances in imaging technologies for the heart, screening of patients for cardiac pathology continues to include the use of traditional stethoscope auscultation. Detection of heart murmurs by the primary care physician often results in the ordering of additional expensive testing or referral to cardiology subspecialists, although many of the patients are eventually found to have no pathologic condition. In contrast, auscultation by an experienced cardiologist is highly sensitive and specific for detecting heart disease. Although attempts have been made to automate screening by auscultation, no device is currently available to fulfill this function. Multiple indicators of pathology are nonetheless available from heart sounds and can be elicited using certain signal processing techniques such as wavelet analysis. Results presented here show that a signal of pathology, the systolic murmur, can reliably be detected and classified as pathologic using a portable electrocardiogram and heart sound measurement unit combined with a wavelet-based algorithm. Wavelet decomposition holds promise for extending these results to detection and evaluation of other audible pathologic indicators.

Algorithms↗

Cardiopulmonary effects of buprenorphine in horses.

OBJECTIVE: To investigate the effects of buprenorphine on cardiopulmonary variables and on abdominal auscultation scores in horses. ANIMALS: 6 healthy adult horses. PROCEDURES: Horses were restrained in stocks and allocated to 2 treatments in a randomized crossover design, with 1-week intervals between each treatment. Saline (0.9% NaCl) solution was administered IV as a control, whereas buprenorphine (10 mug/kg, IV) was administered to the experimental group. Cardiopulmonary data were collected for 120 minutes after buprenorphine or saline solution administration. Abdominal auscultation scores were monitored for 2 and 12 hours after drug administration in the control and experimental groups, respectively. RESULTS: Following control treatment, horses remained calm while restrained in the stocks and no significant changes in cardiopulmonary variables were observed throughout the study. Buprenorphine administration caused excitatory phenomena (restlessness and head shaking). Heart rate, cardiac index, and arterial blood pressure were significantly increased after buprenorphine administration until the end of the observational period (120 minutes). Minimal changes were found in arterial blood gas tensions. Abdominal auscultation scores decreased significantly from baseline for 4 hours after buprenorphine administration. CONCLUSIONS AND CLINICAL RELEVANCE: Buprenorphine induced excitement and hemodynamic stimulation with minimal changes in arterial blood gas tensions. These effects may impact the clinical use of buprenorphine in horses. Further studies are indicated to investigate the effects of buprenorphine on gastrointestinal motility and fecal output.

Analgesics, Opioid↗

[Evaluation and symptomatic treatment of surinfectious exacerbations of COPD: preliminary study of antibiotic treatment combined with fenspiride (Pneumorel 80mg) versus placebo].

UNLABELLED: Exacerbations of chronic obstructive pulmonary disease (COPD) have an inflammatory component in addition to the possible infectious component. The antiinflammatory properties of fenspiride (Pneumorel(R) 80 mg) should be evaluated in this frequent clinical situation. OBJECTIVES: Assess the supplementary therapeutic benefit provided by fenspiride administered in combination with antibiotics in COPD patients presenting an episode of bronchial infection. PATIENTS AND METHODS: A preliminary randomized placebo-controlled double-blind study was conduced in 7 centers. Patients under 80 years of age of both sexes were included. All patients had COPD and presented a bronchial infection defined as the presence of at least 2 of the 3 criteria defined by Anthonisen. Patients were randomly assigned to group F or group P. Group F received an antibiotic therapy from day 1 to day 11 plus fenspiride (3 x 80mg/d from day 0 to day 30). Group P received the same antibiotic therapy plus placebo. Amoxicillin 500mg plus clavulanic acid 125, 3 tablets/day, was administered in both groups. RESULTS: Thirty-nine patients were included (group F 19 patients, group P 20 patients; 6 women and 33 men; mean age 61.1 +/- 9.8 years). The 3 Anthonisen criteria were present in 79% and 75% of the patients in group F and P respectively (NS). On day 11, expectoration resolved in 39% and 32% (NS) and cough in 44% and 16% (NS) of the patients in groups F and P respectively. Lung auscultation returned to normal in 83% of the patients in group F compared with 47% in group P (p=0.05). A composite clinical score including expectoration cough and auscultation findings showed that 28% of the patients in group F were symptom-free on day 11 compared with 0% in group P (p=0.04). On day 30, the two groups were comparable. CONCLUSION: In this preliminary study of patients with COPD presenting a bronchial superinfection, there was a significant improvement in lung auscultation and in the composite clinical score in patients given fenspiride. Fenspiride was thus found to provide an early clinical benefit.

Acute Disease↗

[The Dutch College of General Practitioners' practice guidelines, "Examination of the neonate": response from the perspective of pediatrics].

The practice guideline on routine neonatal examination of the Dutch College of General Practitioners describes the examination of the newborn directly after birth, whether at home or in the hospital. It is proposed that examination be limited to inspection, without auscultation and palpation. If conducted strictly according to the guidelines given, this may be sufficient. However, auscultation of the heart is the most reliable way to determine the heart rate. Including auscultation and palpation in the routine examination after birth would contribute to the experience of general practitioners with these techniques in babies. This is of importance, since general practitioners are the first to be consulted in case of any health problems in this patient category. Previously, it was recommended that the general practitioner visit mother and child on the third, fourth or fifth day after delivery and examine the baby. In the new standard, this second examination is considered to be redundant, based on data in the literature. However, it remains the duty of the general practitioner to inform the parents about (non-specific) early signs of disease in newborns. Furthermore, the threshold for consultation of the general practitioner should be low for the early diagnosis and management of serious conditions, such as septicaemia or congenital heart disease.

Family Practice↗

[Detection of esophageal intubation-assessment of several methods in clinical anesthesia].

OBJECTIVE: To evaluate the sensitivity and reliability of several widely used tests for prompt detection of inadvertent esophageal intubation. METHODS: Both endotracheal and esophageal intubations were made on 40 adult patients undergoing general anesthesia. The tests such as auscultation of bilateral apex of lungs and epigastrium by inexperienced examiners, capnography, SpO2, chest and upper abdomen movements, and airway resistance were evaluated. RESULTS: 90% and 96.25% cases in esophageal intubation were correctly diagnosed via auscultation of bilateral apex of lungs or epigastrium respectively. During esophageal ventilation, abdominal distension was found in 87.5% of cases, but none of them showed chest movements. Meanwhile, PetCO2 fluctuated between 1-2 mmHg, in association with a quick decline of SpO2 in 156 +/- 11 seconds. The airway mean resistance increased, whereas the period of plateau decreased significantly. CONCLUSIONS: (1) Auscultation of epigastrium in combination with bilateral apex of lungs is recommended because of the improved accuracy in tube positioning. (2) Capnography is the most reliable technique for the prompt detection of esophageal intubation, whereas other parameters do not seem to be of comparable value.

Adult↗

Third heart sound revisited: a correlation with N-terminal pro brain natriuretic peptide and echocardiography to detect left ventricular dysfunction.

BACKGROUND: Auscultation of the third heart sound is an age-old sign for predicting ventricular dysfunction. New technology and biomarkers like two-dimensional echocardiography and N-terminal pro brain natriuretic peptide, respectively, have sidelined the utility of this sign, which does not involve any cost and is readily accessible. We sought to find the predictive accuracy of third heart sound and its correlation with N-terminal pro brain natriuretic peptide and ejection fraction using two-dimensional echocardiography to detect left ventricular dysfunction in patients of acute coronary syndrome. METHODS AND RESULTS: One hundred and ten patients presenting with acute coronary syndrome [acute ST elevation myocardial infarction (n=74) and non-ST elevation myocardial infarction (n=36)] were prospectively studied. A senior cardiologist, blinded to N-terminal pro brain natriuretic peptide and ejection fraction results auscultated for a left ventricular third heart sound in each patient. Ejection fraction was measured using modified Simpson's technique on two-dimensional echocardiography and N-terminal pro brain natriuretic peptide was measured using electrochemiluminiscence assay. Median levels of N-terminal pro brain natriuretic peptide were used to provide a dichotomous approach for analysis of the data. Third heart sound was present in 40 patients (acute ST elevation myocardial infarction: n=27, non-ST elevation myocardial infarction: n=13) and absent in 70 patients (acute ST elevation myocardial infarction: n=47, non-ST elevation myocardial infarction: n=23). The sensitivity and specificity of third heart sound for predicting N-terminal pro brain natriuretic peptide above median was 65.5% and 92.7%, respectively. The positive and negative predictive value was 90% and 73%, respectively. The N-terminal pro brain natriuretic peptide of those having third heart sound was 4081 +/- 2705 pg/ml compared to 1239.3 +/- 1169 pg/ml in those without third heart sound (p < 0.001). The sensitivity of third heart sound to detect ejection fraction <45% was 67.9% while the specificity was 74.4%. The positive and the negative predictive values were 47.5% and 87.1%, respectively. The ejection fraction of patients having third heart sound was 47.5 +/- 11.3% compared to 56 +/- 10.4% without third heart sound (p < 0.001). CONCLUSIONS: Auscultation of third heart sound has a good specificity and predictive value for predicting elevated N-terminal pro brain natriuretic peptide and left ventricular dysfunction. Thus age-old clinical cardiology still holds its forte in this new era of technology-driven cardiology.

Heart Sounds↗

Antibiotic prescribing for acute cough: the effect of perceived patient demand.

BACKGROUND: GPs decide whether or not to prescribe antibiotics for acute cough. Apart from clinical signs and symptoms, non-medical reasons influence this decision as well. AIM: To obtain a valid estimate of the effect of perceived patient demand. DESIGN OF STUDY: Secondary analysis of cluster randomised controlled trial data. SETTING: Eighty-five Flemish GPs. METHOD: GPs completed a preprinted form with medical as well as non-medical information and their prescription for 20 consecutive adult patients consulting with acute cough in the periods February to April 2000 and 2001. The effect of perceived patient demand on antibiotic prescribing was estimated by performing alternating logistic regression analysis. A hierarchical backwards elimination procedure, described by Kleinbaum, was used. RESULTS: Seventy-two GPs participated, including 1448 patients eligible for analysis; 500 (34.5%) were prescribed an antibiotic and, according to the GP, 218 (15.1%) asked for an antibiotic. In cases of perceived patient demand antibiotics were prescribed significantly more often (odds ratio [OR] = 4.64, 95% confidence interval [CI] = 2.96 to 7.26). In the final model (n = 819; OR = 4.60, 2.59 to 8.17); Hosmer-Lemeshow goodness-of-fit P = 0.72), the effect of perceived patient demand for an antibiotic depended on the outcome of the lung auscultation. When patient demand was perceived, antibiotics were prescribed significantly more often only in the case of a normal lung auscultation or in the case of only one abnormal auscultatory finding (adjusted OR = 20.83, 95% CI = 8.86 to 48.99; adjusted OR = 4.79; 95% CI = 2.16 to 10.60, respectively). CONCLUSIONS: Perceived patient demand has a significant, independent and clinically relevant effect on antibiotic prescribing for acute cough with negative findings on the lung auscultation. Practice guidelines and interventions to optimise antibiotic prescribing have to take this effect into account.

Acute Disease↗

Diurnal and short-term variation of blood pressure: comparison of preeclamptic, chronic hypertensive, and normotensive patients.

It has been suggested that the decrease in blood pressure during sleep is greater in patients with chronic hypertension than in preeclamptic patients. The DINAMAP (device for indirect noninvasive automatic mean arterial pressure) monitor was used to determine the mean arterial, systolic, and diastolic blood pressure, at 15-minute intervals, and 24 hours. Three groups of 15 patients each were studied: mildly preeclamptic, chronically hypertensive, and normotensive patients in the third trimester. In addition, 2 patients with severe preeclampsia were studied. The automatic readings were compared with auscultated blood pressures. There was short-term variation in the systolic and diastolic blood pressure of 20 to 40 and 15 to 30 mmHg, respectively, with consecutive 15-minute recordings. A decrease in blood pressure during sleep was seen in all groups, except in the 2 patients with severe preeclampsia. This fall varied between 5 and 20 mmHg systolic and 5 and 18 mmHg diastolic. The auscultated blood pressure differed from the automatic blood pressure by 5 to 40 mmHg systolic and 5 to 35 mmHg diastolic. In the clinical management of patients, these findings are significant, as they demonstrate short-term variation in blood pressure and differences in the auscultated versus automatic blood pressure readings. Also, changes in blood pressure occur during sleep; this may be important with regard to the timing and dose of medication given to pregnant patients with chronic hypertension or preeclampsia.

Blood Pressure↗

Remote auscultatory patient monitoring during magnetic resonance imaging.

A system for patient monitoring during magnetic resonance imaging (MRI) is described. The system is based on remote auscultation of heart sounds and respiratory sounds using specially developed pickup heads that are positioned on the precordium or at the nostrils and connected to microphones via polymer tubing. The microphones operate in a differential mode outside the strong magnetic field to reduce various sources of interference from the MRI equipment. After amplification, the signal is transmitted as infrared light to a small, battery-operated receiver and a headphone set. Thus, the patient can be simultaneously auscultated both inside and outside the shielded MRI room by infrared transmission through a metal mesh window. Bench tests of the system show that common mode acoustic noise is suppressed by approximately 30 dB in the frequency region of interest (100-1,000 Hz), and that polymer tubing having a diameter of approximately 2 mm can be used for efficient sound transmission. Recordings in situ show satisfactory detection of both heart sounds and respiratory sounds, although the signal is somewhat masked by noise during imaging. A clinical test incorporating 17 sedated or anesthetized patients was also performed. In all but four cases, the quality of the breath and heart sounds was regarded as acceptable or better.

Acoustics↗