Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52Linked to original sources

Measurement of left ventricular function during arm ergometry using the VEST nuclear probe.

A chest-mounted left ventricular (LV) nuclear probe (VEST) for use during arm and leg ergometry is presented, with a discussion of the validity and reproducibility of LV function measures at rest and exercise. During both arm and leg ergometry in trained subjects, transient changes in LV function/volumes were observed. LV ejection fraction and relative end-systolic and end-diastolic volumes were 25 to 30% less with the arms versus the legs, agreeing with data from other studies using conventional techniques. At peak exercise with both limbs, LV ejection fraction and relative LV end-systolic volume increased, followed by immediate postexercise normalization. The effect was greatest with the arms and reflects the effect of high intramuscular and arterial pressures generated during arm cranking, leading to increased LV afterloading. The VEST permits rapid and noninvasive assessment of LV function during arm exercise, avoiding the limitations of other techniques.

Blood Pressure↗

The effects of bicycle crank arm length on oxygen consumption.

The purpose of this investigation was to determine the effects of various crank arm lengths on oxygen consumption for trained cyclists. Secondary purposes were, if optimal crank arm lengths existed, to determine if these lengths could be predicted based on an individual's leg length. Six trained cyclists completed four experimental protocols riding at a workload of approximately 68% of VO2 max using crank arm lengths of 165, 170, and 175 mm. During each protocol, the cadence, oxygen consumption, and distance traveled were determined, and values were combined to give a VO2.m-1.min-1 value. The values then were placed in either a high, medium, or low efficiency category. Significant differences were found among the three protocols. No significant correlations were found between each subject's most efficient crank arm length and leg length. The results of the study suggest that each subject has a most efficient crank arm length, but it does not appear that optimal crank arm length can be predicted by leg length.

Adult↗

Proprioceptive activity in primate primary somatosensory cortex during active arm reaching movements.

1. We studied the activity of 254 cells in the primary somatosensory cortex (SI) responding to inputs from peripheral proprioceptors in a variety of tasks requiring active reaching movements of the contralateral arm. 2. The majority of cells with receptive fields on the proximal arm (shoulder and elbow) were broadly and unimodally tuned for movement direction, often with approximately sinusoidal tuning curves similar to those seen in motor and parietal cortex. 3. The predominant temporal response profiles were directionally tuned phasic bursts during movement and tonic activity that varied with different arm postures. 4. Most cells showed both phasic and tonic response components to differing degrees, and the population formed a continuum from purely phasic to purely tonic cells with no evidence of separate distinct phasic and tonic populations. This indicates that the initial cortical neuronal correlates of the introspectively distinguishable sensations of movement and position are represented in an overlapping or distributed manner in SI. 5. The directional tuning of the phasic and tonic response components of most cells was generally similar, although rarely identical. 6. We tested 62 cells during similar active and passive arm movements. Many cells showed large differences in their responses in the two conditions, presumably due to changes in peripheral receptor discharge during active muscle contractions. 7. We tested 86 cells in a convergent movement task in which monkeys made reaching movements to a single central target from eight peripheral starting positions. A majority of the cells (46 of 86, 53.5%) showed a movement direction-related hysteresis in which their tonic activity after movement to the central target varied with the direction by which the arm moved to the target. The directionality of this hysteresis was coupled with the movement-related directional tuning of the cells. 8. We recorded the discharge of 93 cells as the monkeys performed the task while compensating for loads in different directions. The large majority of cells showed a statistically significant modulation of activity as a function of load direction, which was qualitatively similar to that seen in motor cortex under similar task conditions. Quantitatively, however, the sensitivity of SI proprioceptive cells to loads was less than that seen in motor cortex but greater than in parietal cortex. 9. We interpret these results in terms of their implications for the central representation of the spatiotemporal form ("kinematics") of arm movements and postures. Most importantly, the results emphasize the important influence of muscle contractile activity on the central proprioceptive representation of active movements.

Afferent Pathways↗

Sex-specific telomere length profiles and age-dependent erosion dynamics of individual chromosome arms in humans.

During aging, telomeres are gradually shortened, eventually leading to cellular senescence. By T/C-FISH (telomere/centromere-FISH), we investigated human telomere length differences on single chromosome arms of 205 individuals in different age groups and sexes. For all chromosome arms, we found a linear correlation between telomere length and donor age. Generally, males had shorter telomeres and higher attrition rates. Every chromosome arm had its individual age-specific telomere length and erosion pattern, resulting in an unexpected heterogeneity in chromosome-specific regression lines. This differential erosion pattern, however, does not seem to be accidental, since we found a correlation between average telomere length of single chromosome arms in newborns and their annual attrition rate. Apart from the above-mentioned sex-specific discrepancies, chromosome arm-specific telomere lengths were strikingly similar in men and women. This implies a mechanism that arm specifically regulates the telomere length independent of gender, thus leading to interchromosomal telomere variations.

Adolescent↗

Conservation of whole arms during chromosomal divergence of phyllotine rodents.

The assumption of simple fusion in a group showing a constant number of chromosome arms was tested by comparison of the G-band patterns of chromosomes of three Phyllotis species. The karyotypes, each of which has 40 chromosome arms, have a 2n of 38, 38, and 40 and are made up of mostly metacentric chromosomes. Operational concepts describing the amount of matching in G-band patterns are proposed, separating chromosomes or arms into those with total correspondence, partial correspondence, or unique cases. Seven chromosomes and 21 arms out of the total were identical in the three species, denoting a conservation of whole-arm band sequences in this group. A greater number of identical arms than of identical chromosomes were observed, giving some support to the simple fusion hypothesis. An unexpected chromosomal divergence was detected, including chromosomal variation in the C-banded sex chromosomes.

Animals↗

Muscle fiber length and moment arm coordination during dorsi- and plantarflexion in the mouse hindlimb.

The purpose of this study was to test the hypothesis that muscle fiber length and joint moment arm are combined in such a way that maximum muscle force is produced during locomotion. Plantarflexor (soleus, SOL and medial gastrocnemius, MG) and dorsiflexor (extensor digitorum longus, EDL and tibialis anterior, TA) muscle architecture in the mouse was measured along with their associated moment arms. Fiber length varied significantly between muscles ranging from 5.7 +/- 0.2 mm (MG) to 7.6 +/- 0.2 mm (TA). Plantarflexor moment arms were over twice as large as dorsiflexor moment arms (1.88 +/- 0.06 mm vs. 0.84 +/- 0.03 mm) suggesting a greater muscle length change with joint angle for plantarflexors compared to dorsiflexors. Using a simple muscle-joint model, the active sarcomere length range in these muscle groups was calculated and proved to be quite similar between functional groups. The active range for dorsiflexors was 2.2-2.4 microns, while the active range for plantarflexors was 2.2-2.5 microns, indicating that both muscle groups operate primarily near the plateau of their length tension-relation. Finally, when calculating force produced by muscles during locomotion, the combination of moment arm and fiber length measured in all muscle groups yielded muscle-joint systems that produced near maximal forces at the velocities modeled. These data indicate that fiber length and moment arm appear to be coordinated to yield the greatest possible force production during locomotion.

Animals↗

Travis and Arms revisited: a second look at a widely used bioconcentration algorithm.

In 1988, Travis and Arms reviewed the literature and collected data to develop a relationship between the octanol-water partition coefficient (Kow) and the uptake of organic compounds into milk and beef (Travis and Arms, 1988). These equations have been utilized for predicting biotransfer factors for organic chemicals when empirical data are lacking. During the external peer review of the draft US Environmental Protection Agency (EPA) guidance entitled Human Health Risk Assessment Protocol for Hazardous Waste Combustion Facilities (US EPA, 1998) and the development of Superfund's Ecological Soil Screening Levels (US EPA, 2000b), questions challenging the derivation and use of these equations were raised. The primary questions raised were: 1) Are the equations presented in Travis and Arms (1988) for the estimation of transfer of organic compounds from contaminated feed to beef and milk technically valid and reproducible? If so, (2) are the equations appropriate across the entire log Kow range? For these reasons, this study was undertaken to validate the original Travis and Arms equations, to review more recent literature, and. if appropriate, to add to the original Travis and Arms data set to obtain updated equations. This paper presents an evaluation of the original Travis and Arms equations, limitations to their use, and steps to reduce uncertainties associated with their use by updating with more current literature.

Algorithms↗

A simple and innovative device to measure arm volume at home for patients with lymphedema after breast cancer.

PURPOSE: We designed an arm volumeter specifically for home use based on the water displacement method. The objective of this study was to determine its accuracy and precision, and compare it with a standard volumeter used in lymphedema clinics worldwide. PATIENTS AND METHODS: Using a standard model hospital volumeter and our own device, we took three consecutive measurements of 11 specially cast cylinders, which had known volumes ranging from 10 mL to 4 L, and measurements of both arms of 15 volunteers. RESULTS: Measurements with both volumeters were highly accurate (R2 = 0.9999) when compared with the known volumes of the cast cylinders, and were strongly correlated (R2 = 0.9974) when each arm volume was compared between volumeters. Measurements with our volumeter were more precise both with the cylinders (average standard deviation [SD], 3.2 v 8 mL; P = .0553) and with the arms (average SD, 11.1 v 19 mL; P = .0034). Whereas the standard volumeter is expensive, fragile (acrylic), and prone to leaks, our volumeter is inexpensive, virtually indestructible, leak proof, and suitable for home use. CONCLUSION: Arm volumes can be measured quickly and accurately at home using a simple, inexpensive, and robust device based on water displacement. Readily accessible arm volumetry at home may have widespread influence on the management of lymphedema after breast cancer.

Anthropometry↗

Effects of scopolamine on repeated acquisition of radial-arm maze performance by rats.

Rats repeatedly acquired the performance of selecting only the four baited arms in an automated eight-arm radial maze, with the arms containing food pellets randomly assigned prior to each session. During each 14-trial (trial: obtain all four pellets) daily session, the number of errors (selecting nonbaited arms or repeating arm selections) showed a within-session decline, and choice accuracy for the first four arm selections showed a positive acceleration across trials for all rats. An index-of-curvature statistic, calculated for total errors, was used to quantify both the within- and between-session improvement of performance. Scopolamine (0.03 to 0.3 mg/kg, ip), but not methylscopolamine (0.3 mg/kg), reduced the accuracy of the first four selections of each trial and increased total within-session errors for all rats. Session times also were increased by scopolamine. An examination of within-session accuracy showed only slight signs of improvement at the higher dosages of scopolamine. The results indicate that behavior in transition states maintained by reinforcement contingencies in the radial maze is similar to that maintained by extended chained schedules, despite the fact that some of the stimuli controlling behavior in the maze are absent at the moment behavior is emitted.

Animals↗

The association among autonomic nervous system function, incident diabetes, and intervention arm in the Diabetes Prevention Program.

OBJECTIVE: Autonomic nervous system dysfunction, a correlate of obesity and poor cardiorespiratory fitness, is associated with the development of diabetes. We tested whether estimates of autonomic nervous system function improved in the intensive lifestyle versus metformin or placebo arms of the Diabetes Prevention Program (DPP) and whether baseline or a change in autonomic nervous system function was associated with the development of diabetes over 3.2 years. RESEARCH DESIGN AND METHODS: In 2,980 DPP participants, 12-lead electrocardiograms were measured at baseline and annually. Heart rate, heart rate variability (HRV), and QT duration were used to estimate fitness and autonomic nervous system function. RESULTS: In the lifestyle arm, heart rate and QT indexes decreased, and HRV increased over time. The magnitude of decline in heart rate and QT duration was substantially smaller in the other arms, whereas HRV did not increase. Baseline heart rate was the only index significantly (P < 0.05) associated with incident diabetes after adjustment for demographics and weight change (hazard ratio for lifestyle and metformin arms = 1.19 and 1.17 per 10.6 beats/min, respectively). Decreases in heart rate and QT indexes and increases in HRV over time were associated with a lower risk of developing diabetes. The protective association between decreased heart rate and incident diabetes in the lifestyle arm remained significant after accounting for change in weight and physical activity. CONCLUSIONS: Indexes that reflect autonomic function and fitness improved (i.e., heart rate decreased and HRV increased) in the lifestyle modification arm of the DPP. Improvements in these indexes are inversely associated with the development of diabetes independent of weight change.

Autonomic Nervous System↗

Moment arms about the carpal and metacarpophalangeal joints for flexor and extensor muscles in equine forelimbs.

OBJECTIVE: To determine whether muscle moment arms at the carpal and metacarpophalangeal joints can be modeled as fixed-radius pulleys for the range of motion associated with the stance phase of the gait in equine forelimbs. SAMPLE POPULATION: 4 cadaveric forelimbs from 2 healthy Thoroughbreds. PROCEDURE: Thin wire cables were sutured at the musculotendinous junction of 9 forelimb muscles. The cables passed through eyelets at each muscle's origin, wrapped around single-turn potentiometers, and were loaded. Tendon excursions, measured as the changes in lengths of the cables, were recorded during manual rotation of the carpal (180 degrees to 70 degrees) and metacarpophalangeal (220 degrees to 110 degrees) joints. Extension of the metacarpophalangeal joint (180 degrees and 220 degrees) was forced with an independent loading frame. Joint angle was monitored with a calibrated potentiometer. Moment arms were calculated from the slopes of the muscle length versus joint angle curves. RESULTS: At the metacarpophalangeal joint, digital flexor muscle moment arms changed in magnitude by < or = 38% during metacarpophalangeal joint extension. Extensor muscle moment arms at the carpal and metacarpophalangeal joints also varied (< or = 41% at the carpus) over the range of joint motion associated with the stance phase of the gait. CONCLUSIONS AND CLINICAL RELEVANCE: Our findings suggest that, apart from the carpal flexor muscles, muscle moment arms in equine forelimbs cannot be modeled as fixed-radius pulleys. Assuming that muscle moment arms at the carpal and metacarpophalangeal joints have constant magnitudes may lead to erroneous estimates of muscle forces in equine forelimbs.

Animals↗

Left-arm dominance in active positioning.

The relative accuracy of the left and the right arms in active positioning was studied in a group of 24 male right-handed undergraduates. The task required active positioning of the left and right arms at each of the four angular positions (30 degrees, 45 degrees, 60 degrees, and 75 degrees). The left arm was more accurate in active positioning than the right arm. There was a progressive increase in error for both arms as the arms flexed more in reducing the angle at the joint. Results are discussed in light of suggestions concerning the superiority of the right hemisphere in the processing of kinesthetic and proprioceptive information.

Adult↗

Dynamic scapulohumeral rhythm: the effects of external resistance during elevation of the arm in the scapular plane.

The purpose of this study was to characterize the scapulohumeral rhythm in the normal shoulder during dynamic elevation of the arm in the scapular plane and to compare the scapulohumeral rhythm during three different states of loading: 1) arm completely unloaded and passively elevated, 2) light load consisting of active elevation against the weight of the limb, and 3) heavy loading against maximal resistance. Electromagnetic tracking was used to record three-dimensional scapular and humeral kinematics on 25 normal subjects. Cardan angles were calculated to assess the dynamic relationship of humeral elevation to scapular upward rotation. The results show that during dynamic humeral elevation the scapulohumeral rhythm changes depending on the phase of elevation and the external load on the arm. During passive range of motion, the scapulohumeral rhythm decreased from 7.9:1 to 2.1:1 as the arm was elevated. Light shoulder loads caused an increase of the scapulohumeral rhythm from 3.1:1 to 4.3:1 as the arm was elevated. Heavy shoulder loading resulted in an increasing scapulohumeral rhythm from 1.9:1 to 4.5:1 as the arm was elevated. The results suggest that the historical assumption of a simple linear 2:1 scapulohumeral rhythm ratio may be overly simplistic and may not accurately describe the scapulohumeral rhythm under varying dynamic conditions. Therapists need to understand the normal changing relationships of the scapulohumeral rhythm under different conditions for accurate interpretation of clinical observations.

Adolescent↗

Voice-controlled robotic arm in laparoscopic surgery.

AIM: To report on our experience with a voice-directed robotic arm for scope management in different procedures for "solo-surgery" and in complex laparoscopic operations. METHODS: A chip card with orders for the robotic arm is individually manufactured for every user. A surgeon gives order through a microphone and the optic field is thus under direct command of the surgeon. RESULTS: We analyzed 200 cases of laparoscopic procedures (gallbladder, stomach, colon, and hernia repair) done with the robotic arm. In each procedure the robotic arm worked precisely; voice understanding was exact and functioned flawlessly. A hundred "solo-surgery" operations were performed by a single surgeon. Another 96 complex videoscopic procedures were performed by a surgeon and one assistant. In comparison to other surgical procedures, operative time was not prolonged, and the number of used ports remained unchanged. CONCLUSION: Using the robotic arm in some procedures abolishes the need for assist ance. Further benefit accrued by the use of robotic assistance includes greater stability of view, less inadvertent smearing of the lens, and the absence of fatigue. The robotic arm can be used successfully in every operating theater by all surgeons using laparoscopy.

Acoustics↗

Quantification of the gravity-dependent change in the C-arm image center for image compensation in fluoroscopic spinal neuronavigation.

In the quest to develop a viable, frameless spinal navigation system, many researchers are utilizing the C-arm fluoroscope. However, there is a significant problem with the C-arm that must be quantified: the gravity-dependent sag effect resulting from the geometry of the C-arm and aggravated by the inequity of weight at each end of the C-arm. This study quantified the C-arm sag effect, giving researchers the protocol and data needed to develop a program that accounts for this distortion. The development of spinal navigation algorithms that account for the C-arm sag effect should produce a more accurate spinal navigation system.

Artifacts↗

Controlled, rapid uprighting of molars: a surprisingly simple solution the pivot arm appliance.

In orthodontic cases where the regional anatomy provides limited room for eruption, there is etiologically a higher occurrence of tipped/impacted second molars. Although second molar extraction with third molar replacement is a useful option, the "Pivot Arm Appliance" encourages the uprighting of the second molar as a preferred treatment. The most unique and important attribute of the "Pivot Arm Appliance" is the rotating tube. In cases of access limitation, the disto-occlusal surface of the molar presents as one area that is accessible. Other features of the "Pivot Arm Appliance" include: The position of the rotator tube delivers optimal rotational force through the pivoting action of the tube/arm complex. The "Pivot Arm Appliance" takes advantage of the efficiency and simplicity of a Class I lever system. The anatomical fulcrum being the dense cortical bone located anterior to the ascending ramus. The vertical spring system is compact, reliable and delivers gentle controlled force in rotational direction. The lingual location of the "Pivot Arm Appliance" does not hinder the function of the tongue, impinge on the soft tissue or interfere with normal masticatory function. The ease of placement of the rotator tube and subsequent insertion of the spring. It is well to note the uprighting appliance provides a very useful and practical approach to the unique problem of severely tipped second molars with limited buccal access. The "Pivot Arm Appliance" does not function only in these situations but can be used in all cases of second molar uprighting of a moderate to severe nature.

Adolescent↗

[Development and application of self-powered short arm human centrifuge].

OBJECTIVE: To present the development and application of a self-powered short arm human centrifuge. METHOD: Self-powered short arm human centrifuge consisted of human power, adjustable resistance trig, short arm and supporting construction parts. It was driven by human power. The short arm turned around the supporting part so artificial gravity is produced. The physical load can be adjusted by the adjustable resistance part. G-level depends on the rotative velocity of the central shaft. Nine healthy male volunteers received self-powered short arm human centrifuge training for 5 min per day with rotative velocity of 30-34 r min-1 for 7 d. Cardiac pumping function was measured before and after training. RESULT: Heart rate (HR) decreased significantly while left ventricular ejection time (LVET) increased significantly after 3 d training, and HR and LVET changed further after 7 d training. Stroke volume increased significantly only after 7 d training. CONCLUSION: Self-powered short arm human centrifuge combines artificial gravity and exercise and included other advantages of safety and economy of construction. Cardiac pumping function could be improved by 7 d training. It may be used for anti-G physiological training or as a countermeasure to counteract the effect of microgravity.

Adaptation, Physiological↗

[Divergence patterns of banding sequences in different polytene chromosome arms reflect relatively independent evolution of different genome components].

Divergence patterns of the banding sequences from the chromosomal arms A, C, D, E, and F were compared in 63 species of the genus Chironomus. Evaluation of the number of breakpoints between the pairs of inverted banding sequences and the analysis of the lengths of the conserved segments in the chromosomal arms in the chironomid species examined showed that different arms evolved relatively independently and at different rates. No direct correlation between the arm length and the breakpoints number was observed. The length of the conservative segment was not fixed, but was arm-specific. Robustness and fidelity of the estimates of phylogenetic relationships between the species examined increased with the arm number, i.e., with the genome proportion included in the analysis.

Animals↗