Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SUTURES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Evaluation of polytetrafluoroethylene suture for frontalis suspension as compared to polybutylate-coated braided polyester.

PURPOSE: To evaluate the efficacy of polytetrafluoroethylene (Gore-Tex) suture as compared to polybutylate-coated braided polyester (Ethibond) suture as sling materials for frontalis suspension in bilateral congenital ptosis. METHODS: Frontalis sling surgery by modified Crawford's double triangle technique was performed on 30 patients (60 eyes) with bilateral ptosis. The patients were randomized into two groups depending on the type of suture material used: polytetrafluoroethylene or braided polyester. RESULTS: Polytetrafluoroethylene suture achieved a statistically significant better and more stable ptosis correction, with slightly more lagophthalmos, than braided polyester suture over a mean (+/- SD) follow-up period of 16 +/- 3.24 months. There were more postoperative complications with braided polyester suture, but the difference was not statistically significant. CONCLUSION: This is the first clinical study in which polytetrafluoroethylene in the form of suture has been studied. Polytetrafluoroethylene suture was found to be a safe and effective sling material for frontalis suspension and it can be recommended for clinical use.

Adolescent↗

Histopathological evaluation of rotation sutures for involutional entropion.

Rotation sutures are a popular method of temporarily correcting involutional entropion. The permanence of the procedure depends on a fibrotic scar along the suture tracks. Sutures which create generous scars would probably produce the most satisfactory results. In this study 4-0 chromic gut, nylon, and silk sutures were evaluated in rabbit lower eyelids for their ability to create histologically demonstrable fibrous tracks. All three sutures incited inflammatory cells and fibroblastic activity with collagen formation at two and four weeks. Residual scar tracks were observed at six weeks (two weeks after suture removal) also. Human specimens showed similar types of scar formation from the sutures. It was apparent that all three sutures create fibrotic scars along their tracks sufficient to correct, at least temporarily, involutional entropion.

Animals↗

Pull-out strength of suture anchors for rotator cuff and Bankart lesion repairs.

Surgical reconstructions of anterior-inferior shoulder instabilities and rotator cuff injuries require secure fixation of soft tissue to bone. Sutures are inserted directly through transosseous tunnels in current techniques, which are surgically complex and not always adequate for fixation strength. Using fresh-frozen cadaveric human specimens, our objectives were 1) to compare immediate pull-out strength of two versions of polyacetal suture anchors (wedge and rod) with conventional suture-only attachment techniques in Bankart lesion and rotator cuff repairs, and 2) to compare pull-out strength of the two polyacetal suture anchors with a metallic suture anchor. Our results indicate no significant differences in fixation strength of Bankart lesions or rotator cuff repairs using sutures only, or using wedge or rod polyacetal suture anchors (P = 0.70). Pull-out force did not differ significantly (P = 0.37) between the two polyacetal anchors. Polyacetal anchors exhibited higher pull-out forces than metallic anchors when inserted into metaphyseal regions of the tibia and significantly higher pull-out forces (P < 0.001) when inserted into metaphyseal regions with thicker cortical walls. Our results indicate that both polyacetal suture anchors provide adequate immediate fixation for soft tissue repairs in the human shoulder.

Acetals↗

A randomized, controlled trial comparing long-term cosmetic outcomes of traumatic pediatric lacerations repaired with absorbable plain gut versus nonabsorbable nylon sutures.

OBJECTIVES: To show that the use of absorbable sutures in pediatric traumatic lacerations affords good long-term cosmesis and no increase in complications (infection, dehiscence rates, and need for surgical scar revision) when compared with wounds sutured with nonabsorbable sutures. METHODS: This was a randomized clinical trial conducted in a pediatric emergency department. Patients 1-18 years of age who presented to the emergency department with lacerations < 12 hours old were recruited between January 1999 and December 2001. Exclusion criteria were the following: wounds that could be approximated by tissue adhesives, animal/human bites, gross contamination, puncture/crush wounds, wounds crossing joints, lacerations of tendon/nerve/cartilage, collagen vascular disease, immunodeficiency, diabetes mellitus, bleeding disorder, and scalp lacerations. Patients were randomized into one of two groups: those receiving absorbable plain gut sutures (group A) and those receiving nonabsorbable nylon sutures (group NA). Board-eligible/certified pediatric emergency physicians or clinical fellows performed laceration repair in a standardized approach. All wounds were reevaluated within ten days by a single research nurse who assessed the wounds using a previously validated wound evaluation score (WES) composed of six items (presence of step-off, contour irregularities, margin separation, edge inversion, extensive distortion, and overall cosmetic appearance). A score of 6/6 was considered optimal. The study nurse also noted the presence of infection and dehiscence. The patients were then seen by a single blinded plastic surgeon at four or five months who evaluated the wound using a previously validated visual analog scale of cosmesis (VAS). In addition, the surgeon repeated the WES and assessed the need for surgical scar revision. RESULTS: A total of 147 patients were eligible, and 52 patients declined to participate. Of the 95 patients enrolled, 50 were randomized to group A and 45 to group NA. The two groups had similar ages, gender distributions, rates of use of sedation or steri-strips, wound lengths and widths, mechanisms of injury, and wound locations. At the short-term follow-up, no difference was found in the proportion of optimal WES scores between group A (63% of patients) and group NA (49% of patients) (relative risk = 0.73; 95% confidence interval [95% CI] = 0.45 to 1.17). No difference was found in the rates of infection and dehiscence between the two groups. Sixty-three of the 95 patients presented for long-term follow-up. The groups remained similar with respect to patient and wound characteristics as well as wound location. The average VAS score at four months was 79 (95% CI = 73 to 85) for group A and 66 (95% CI = 55 to 76) for group NA. In addition, no differences were found in the proportion of optimal WES between group A (36% of patients) and group NA (28% of patients) at four months (relative risk = 0.88; 95% CI = 0.62 to 1.26). Surgical scar revision was recommended for only three patients, of whom two were in group A. No patients chose to have their scars revised. No differences were found between group A and group NA for the rates of dehiscence (2% vs. 11%; p = 0.07) and infection (0 vs. 2; p = 0.3). CONCLUSIONS: The use of plain catgut absorbable sutures in the repair of traumatic lacerations in children appears to be an acceptable alternative to nonabsorbable sutures because the long-term cosmetic outcome seems to be at least as good. In this study, plain gut suture material seemed to provide slightly better cosmesis. In addition, no difference was found in the rate of dehiscence or infection between the groups.

Absorbable Implants↗

Comparison of anastomotic suturing techniques in the rat esophagus.

BACKGROUND: Long-gap esophageal atresia continues to be a challenging pediatric thoracic surgical problem. Despite the use of various tension relieving procedures, the esophageal anastomosis is often performed under considerable tension. Excessive tension can cause anastomotic sutures to pull through the esophageal tissue, with resultant early esophageal anastomotic dehiscence. To test the hypothesis that interrupted horizontal mattress sutures would withstand the forces of tension better than interrupted simple sutures, an experimental study of rat esophageal anastomoses was done. METHODS: Twenty rats were killed and their esophagi were excised. The esophagi were divided in the mid portion and end-to-end anastomoses were done using interrupted 6-0 polypropylene sutures. Ten rats had anastomoses done with interrupted simple sutures and ten had interrupted horizontal mattress suturing. Anastomotic breaking strength was tested in a tensiometer. RESULTS: Anastomotic breaking strength was 3.22+/-0.56 N for the interrupted simple sutured anastomoses and 3.51+/-0.61 N for the interrupted horizontal mattress group (p=0.30). The difference was not significant. CONCLUSIONS: In this animal study interrupted simple and horizontal mattress suturing withstood the disruptive forces of anastomotic tension equally well.

Anastomosis, Surgical↗

A biomechanical comparison of suture constructs used for coracoclavicular fixation.

There is no consensus regarding surgical treatment for severely dislocated acromioclavicular joints. Although many treatments are suture-based, the suture materials and resulting suture-bone constructs have been subjected to limited systematic evaluation. This study identifies the strongest and least deforming suture construct among those commonly used for such repairs. Each suture-based repair was tested on a simulated clavicle and coracoid process with the skeletal components distracted until the suture failed to obtain tensile strength. Additional groups of sutures were subjected to cyclic loading to determine resistance to deformation. Panacryl braid had significantly greater tensile strength than all other constructs: Polydioxanone (PDS) braid, Mersilene tape, and Ethibond #5. Deformation after cyclic loading of Panacryl braid, PDS braid, and two strands of Mersilene tape was significantly less than that of the other constructs. A bioabsorbable suture loop, such as Panacryl, can act as a temporary internal splint, maintaining acromioclavicular joint reduction long enough for ligamentous healing during rehabilitation, and can avoid complications associated with permanent fixation materials. Panacryl braid deserves serious consideration for coracoclavicular fixation because of its strength, resistance to deformation, and bioabsorbable properties.

Absorbable Implants↗

Postmortem analysis of anastomotic suture line disruption following carotid endarterectomy.

The tensile strength of a surgical suture is essential in maintaining the integrity of vascular anastomoses. While faulty operative technique and the loading strength of individual sutures have been implicated in spontaneous suture line disruptions, there has, to date, never been a published postmortem analysis of a suture that has known to have failed. We present the case of suture line disruption leading to fatal exsanguination in a 77-year-old man following carotid endarterectomy with a facial vein patch. Using both dissecting and scanning electron microscopy, we determined that surgical technique (an untied knot) was the cause of the suture line disruption. The removal of a broken or untied suture at surgery or at autopsy should not preclude proper analysis of the failed suture, because the results can have both medico-legal and public health implications.

Aged↗

[The expression of TGF-beta1 mRNA in the maxillary sutures of puberty rhesus loaded with the class III intermaxillary orthopedic force].

OBJECTIVE: The purpose of the study is to detect the expression of TGF-beta1 mRNA in the maxillary sutures of puberty rhesus during different periods of the loading of intermaxillary class III orthopedic force. METHODS: The animal model was established with 6 puberty female rhesus, which were randomly divided into experimental group (wearing class III twin-block magnet appliance, each 2 rhesus for 3 and 6 month respectively) and control group (not wearing any appliance, each 1 rhesus for 3 and 6 month respectively). Tissue sections were obtained perpendicular to the sutures. In situ hybridization was used to the expression of TGF-beta1 mRNA, and the expression intensity was measured and statistics was performed by SPSS 11.0. RESULTS: There were no statistic differences of cellular density between palatomaxillary suture in vertical group and pterygomaxillary suture in horizontal group, but statistic differences were found between other groups. The expression of TGF-beta1 mRNA was detected in the control group, but the expression intensity was obviously increased after the load of intermaxillary class III orthopedic force. Statistically significant differences were found among all groups except the six months experimental group and control group of temporozygomatic sutures and pterygomaxillary sutures. Experimental groups were more intensive than the control group and three months group was more intensive than the six months group. CONCLUSION: The active tissue remodeling happened in the circummaxillary sutures by the effect of class III intermaxillary orthopedic force. Cell proliferation, extracellular matrix synthesis and bone formation were accelerated. During the different remodeling periods, the expression intensities were different, which may be related to the different force loading manners, the different reaction of sutures to the orthopedic force and the different biological function of TGF-beta1 in the different periods.

Animals↗

Transseptal suture to secure middle meatal spacers.

Middle meatal spacers are used by many sinus surgeons to aid postoperative care. Aspiration of a spacer is a concern. We demonstrate a novel method of securing spacers with a transseptal suture to prevent aspiration. We fashion each spacer from a powder-free, nonlatex glove finger that is packed with a Merocel sponge. The open end of the finger is closed with 2-0 Prolene sutures. For a bilateral procedure, the needle is left attached to one of the spacers. A spacer is placed in each ethmoid cavity, the attached needle is passed through the anterior cartilaginous septum, and the suture is tied to the suture on the opposite spacer. For unilateral procedures, the suture on the single spacer is passed to the contralateral side and tied on itself. One week later, the transseptal suture is cut and the spacers are removed. We performed this procedure on 78 patients who had undergone total ethmoidectomy. None of the spacers migrated during the 1 week they were in place. One patient complained of pain during removal of a spacer. During follow-up of 2 to 10 months, we found no evidence of injury to the septum at the site of the transseptal suture. We conclude that the transseptal suture is a safe and cosmetically superior method of securing middle meatal spacers.

Adolescent↗

[Aortic isthmus stenosis: a comparison of resorbable and non-resorb able sutures].

Absorbing vessel suture material presents the particular advantage of unlimited growth potential of young vessels. This is due to low tissue irritation and only a minimum of foreign-body reaction of the tissue. Retrospectively, we compared 9 patients (5 +/- 3 years of age), who underwent resection of the coarctation and end-to-end reanastomosis, with absorbing simple continuous suture material versus 8 patients (7 +/- 5 years of age; NS) with non-absorbing suture material using a prolong-thread suture technique, who were operated between 1980 and 1986. The growth increase before to 4 years after operation (24 +/- 10% in the "absorbing suture group-A" and 36 +/- 27% in the "non-absorbing suture group-B"; NS) just as the pressure gradient (55 +/- 11 mm Hg in group A, 58 +/- 16 mm Hg in group B (NS) before and 6 +/- 8 mm Hg in group A, 5 +/- 9 mm Hg in group B (NS) 4 years after operation) shows no significant difference. Therefore one may say that absorbing material in simple continuous suture technique presents a good alternative to the non-absorbing material in the prolonged-thread suture technique for correction of aortic isthmus stenosis, whereby analogous growth can be expected.

Anastomosis, Surgical↗

Growth of tracheal anastomoses in lambs. Comparison of PDS and Vicryl suture material and interrupted and continuous techniques.

Tracheal anastomoses were performed in 19 lambs (mean age 4 weeks, mean weight 9.8 kg) to compare polydioxanone (PDS) and polyglactin 910 (Vicryl) suture material (Ethicon, Inc., Somerville, N.J.) and simple continuous and simple interrupted suture technique. Each animal had two anastomoses with full-thickness bites for both suture techniques. Animals were killed at 4 months (n = 6) or 8 months (n = 5). Eight animals died before they were scheduled to be put to death (mean 6 weeks postoperatively). Transverse sections of the trachea were taken at the level of the anastomoses and three tracheal rings above and below each anastomosis. The cross-sectional area of the tracheal lumen of these transverse sections was measured with a computerized digitizing tablet. A percent luminal area for each anastomosis was calculated relative to the mean tracheal area three rings above and three rings below the anastomosis. There was little difference between interrupted and continuous technique with either suture material (p = 0.94). In 10 animals that each served as its own control for suture material, PDS anastomotic area was 55.0% +/- 4.1% of mean tracheal luminal area compared with 45.4% +/- 7.1% for Vicryl anastomoses (p = 0.06). Histologic analysis revealed a more intense inflammatory reaction surrounding multifilament Vicryl sutures with more rapid resorption and greater subsequent fibrosis relative to the reaction seen with PDS sutures. A small clinical experience with seven infants has confirmed short-term satisfactory clinical performance of continuous PDS suture for tracheal anastomosis.

Anastomosis, Surgical↗

Infectivity of vascular sutures.

Bacterial adherence to vascular sutures was evaluated in vitro using radioactively labeled Staphylococcus aureus. The following suture materials were tested: polypropylene, silicone-treated braided polyester, and Teflon-treated braided polyester. Significantly fewer bacteria adhered to the monofilament polypropylene than either of the braided polyester sutures. There was no significant difference between silicone-treated and Teflon-treated polyester from the standpoint of bacterial adherence. Vascular sutures were evaluated in vivo using a mouse wound model. Sutures were tested with and without knots. When tested without knots, fewer bacteria were recovered from wounds containing polypropylene suture compared to either of the braided materials, although this apparent advantage did not prove to be statistically significant. When studied with knots, the differences among types of suture were much less marked and, again, not significant. The purported contribution of the monofilament structure of a suture to its infection resistance may have been overstated.

Adhesiveness↗

[Synthetic resorbable and synthetic non-resorbable suture materials in microvascular surgery. Animal experimental study].

In a series of experiments on the aorta of the rat, the behaviour of an absorbable monofilament suture VICRYL (Polyglactin 910) was compared to that of a non-absorbable suture ETHILON (Polyamide 6/6). A total of 86 rats was operated upon and examined over a period of 70 days. The report includes a complete description of experimental procedures and techniques used during the operations. The evaluation of the experiments took place after completion of the mechanical, histological and scanning electron microscopical tests. It has been proven that under similar conditions, the 0,2 metric suture VICRYL has adequate tensile strength to withstand the intravascular pressure in a vessel with an outer diameter of approx. 1,5 mm. Aneurysm, stenosis and dehiscence of the anastomosis did not occur. The VICRYL suture showed no reactive processes after a period of 42 days. With the suture ETHILON the inflammation of the media and the hyperplasia of the intima persisted even after 70 days, at the end of the experiment. It is therefore shown in microsurgery, the monofilament absorbable suture VICRYL and the non-absorbable monofilament suture ETHILON are equal in their mechanical qualities, but that the suture VICRYL has by far the better tissue compatibility.

Animals↗

Suture sinus formation following closure of ventral midline incisions with polypropylene in three horses.

Suture sinuses formed in 3 horses following closure of ventral midline incisions with size-2 polypropylene. Suture sinuses healed after the suture material was removed. Suture sinus formation following closure with polypropylene may be related to the suture material's mechanical, rather than its chemical, properties. If polypropylene is used to close the linea alba in horses, the amount of tissue incorporated in the suture loops, suture tension, and knot volume should be minimized to decrease the risk of suture sinus formation.

Abdominal Muscles↗

Does use of permanent suture material affect outcome of the modified Pereyra procedure?

OBJECTIVE: To determine the effect of absorbable versus permanent suture on outcome of the modified Pereyra procedure for stress urinary incontinence. METHODS: A review was performed of case-series reports of outcome of the modified Pereyra procedure for stress urinary incontinence that provided at least 1 year of follow-up and that specified the suture material used. Outcomes of cases in which permanent suture was used were compared with cases in which absorbable suture was used. The groups were further stratified according to whether success of the procedure was determined objectively or subjectively. Chi-square analysis was performed. RESULTS: Fourteen case-series reports were examined, representing a total of 988 modified Pereyra operations. Overall, the relative risk (RR) of failure when absorbable suture was used was 1.8 times higher than with permanent suture (95% confidence interval [CI] 1.4-2.3; P < .0001) using objective or subjective outcome criteria. The RR of failure using absorbable suture when judged by objective criteria only was 1.6 (95% CI 1.1-2.3; P = .03) and when judged by subjective outcome only was 2.3 (95% CI 1.5-3.4; P < .0001). CONCLUSION: Until a randomized controlled trial is done, the available evidence supports the use of permanent suture material whenever the modified Pereyra procedure is performed.

Humans↗

The effect of adjustable suture techniques on scleral resistance.

BACKGROUND AND OBJECTIVE: The effect of adjustable suture strabismus surgery techniques on the ease of the postoperative adjustment has not been determined. An in vitro animal model was developed to compare several intraoperative variables with the ability to adjust the sutures. MATERIALS AND METHODS: The amount of force required to advance and recess the suture was measured using different sutures, suture coatings, needles, and scleral tunnel techniques. RESULTS: Scleral tunnels placed at an angle to the muscle insertion caused significantly greater scleral resistance as compared with tunnels placed perpendicular to the insertion. Although differences were noted in the scleral resistance with different needles, suture coatings, and suture materials, there was a considerable overlap of the effect. CONCLUSIONS: Scleral tunnels placed perpendicular to the muscle insertion and parallel to the plane of action of the muscle offer the best technique for minimizing scleral resistance. Other less important factors include shorter scleral tunnels, larger needles, and special suture coatings.

Animals↗

Conjunctival retraction suture for fornix adjustable strabismus surgery.

The fornix approach to strabismus surgery is advantageous because the incision is made under the eyelid, there is no need for conjunctival sutures, it is comfortable for the patient, and there is minimal postoperative scarring. The major disadvantage of the fornix approach for the adjustable suture technique has been poor exposure to the muscle-suture apparatus and poor postoperative knot exposure. We describe herein the use of a subconjunctival retraction suture for adjustable suture surgery with the fornix approach. This suture retracts the conjunctiva, exposing the adjustable muscle-suture apparatus while simultaneously fixating the globe. A novel way of tying the noose around the pole sutures and preventing noose slippage is also presented. This technique provides excellent exposure, fixation of the globe, and complete coverage of the knot with conjunctiva after adjustment.

Conjunctiva↗

Chimpanzee variation facilitates the interpretation of the incisive suture closure in South African Plio-Pleistocene hominids.

For a better understanding of early hominid growth patterns, we need to compare skeletal maturation among humans and chimpanzees. This study provides new data on variation of the incisive suture closure in extant species to facilitate the understanding of growth patterns among South African Plio-Pleistocene hominids. The complete anterior closure of the incisive suture occurs early during human life, mostly before birth. In contrast, in chimpanzees a complete anterior closure occurs mostly after the eruption of either the first permanent molars (pygmy chimpanzees) or the third molars (common chimpanzees). The first aim of this study is to test whether the patterns of closure of both the anterior and palatal components of the incisive suture in chimpanzees accurately mirror their polytypism by investigating 720 museum specimens of known geographical origin. Then we use the data gleaned from the incisive suture closure in chimpanzees to determine whether there are different growth patterns among South African Plio-Pleistocene hominids and to interpret them. Results about the pattern of incisive suture closure are consistent with the differences among chimpanzees as revealed by molecular data. Thus, the variation in chimpanzee patterns of incisive suture closure facilitates the interpretation of morphology in South African fossil hominids. In Australopithecus (Paranthropus) robustus as compared to Australopithecus africanus, the complete anterior closure and, probably, the complete palatal closure of the incisive suture occurs during early life in the same way as they occur in humans. Moreover, the closure pattern observed on Stw 53, a supposed early Homo from Sterkfontein Member 5, is similar to that seen in A. africanus and in chimpanzees. Thus, with respect to the anterior component of the incisive suture, A. africanus and Stw 53 retain the primitive feature for which A. (P.) robustus and Homo share the derived character state. Finally, it is worth noting that the Taung child does not show the robust condition.

Animals↗