Reconstruction in diffraction ultrasound tomography using nonuniform FFT.

We show an iterative reconstruction framework for diffraction ultrasound tomography. The use of broad-band illumination allows significant reduction of the number of projections compared to straight ray tomography. The proposed algorithm makes use of forward nonuniform fast Fourier transform (NUFFT) for iterative Fourier inversion. Incorporation of total variation regularization allows the reduction of noise and Gibbs phenomena while preserving the edges. The complexity of the NUFFT-based reconstruction is comparable to the frequency-domain interpolation (gridding) algorithm, whereas the reconstruction accuracy (in sense of the L2 and the L(infinity) norm) is better.

Algorithms↗

Modeling of scanning laser polarimetry images of the human retina for progression detection of glaucoma.

The development of methods to detect slowly progressing diseases is often hampered by the time-consuming acquisition of a sufficiently large data set. In this paper, a method is presented to model the change in images acquired by scanning laser polarimetry, for the detection of glaucomatous progression. The model is based on image series of 23 healthy eyes and incorporates colored noise, incomplete cornea compensation and masking by the retinal blood vessels. Additionally, two methods for detecting progression, taking either one or two follow-up visits into account, are discussed and tested on these simulated images. Both methods are based on Student's t-tests, morphological operations and anisotropic filtering. The images simulated by the model are visually pleasing, show corresponding statistical properties to the real images and are used to optimize the detection methods. The results show that detecting progression based on two follow-up visits greatly improves the sensitivity without adversely affecting the specificity.

Algorithms↗

Elastic scattering and light transport in three-dimensional collagen gel constructs: a mathematical model and computer simulation approach.

A mathematical modeling approach for elastic scattering and light propagation is presented, which can be used to obtain the scattering coefficient, the index of refraction, and the distribution of the collagen fibrils in a gel. Collagen fibrils can be realistically represented by small cylindrical particles. The analysis of the scattering of light by such particles provides the scattering coefficient. Light transport in multilayered tissues has been modeled and the collagen fibrils scattering coefficient has been considered as main input parameters. Assuming that a gel is composed of fibrils with the same diameter, it is possible to obtain all the input parameters of the model and, therefore, a simulated spectrum. This can be repeated for several diameters. Considering a gel composed of fibrils with different diameters, it is possible to obtain a best-fitting simulated spectrum as a weighted sum (least-square-error based) of the spectra corresponding to several fibril diameters, and, therefore, obtain an estimate of the percentages of fibrils of each diameter in the gel. Moreover, the scattering coefficient and refractive index, which are also provided by the model, are relevant parameters as they relate to tissue properties in their own right.

Algorithms↗

Generalized mosaicing: polarization panorama.

We present an approach to image the polarization state of object points in a wide field of view, while enhancing the radiometric dynamic range of maging systems by generalizing image mosaicing. The approach is biologically-inspired, as it emulates spatially varying polarization sensitivity of some animals. In our method, a spatially varying polarization and attenuation filter is rigidly attached to a camera. As the system moves, it senses each scene point multiple times, each time filtering it through a different filter polarizing angle, polarizance, and transmittance. Polarization is an additional dimension of the generalized mosaicing paradigm, which has recently yielded high dynamic range images and multispectral images in a wide field of view using other kinds of filters. The image acquisition is as easy as in traditional image mosaics. The computational algorithm can easily handle nonideal polarization filters (partial polarizers), variable exposures, and saturation in a single framework. The resulting mosaic represents the polarization state at each scene point. Using data acquired by this method, we demonstrate attenuation and enhancement of specular reflections and semireflection separation in an image mosaic.

Algorithms↗

Polarimetric image segmentation via maximum-likelihood approximation and efficient multiphase level-sets.

This study investigates a level set method for complex polarimetric image segmentation. It consists of minimizing a functional containing an original observation term derived from maximum-likelihood approximation and a complex Wishart/Gaussian image representation and a classical boundary length prior. The minimization is carried out efficiently by a new multiphase method which embeds a simple partition constraint directly in curve evolution to guarantee a partition of the image domain from an arbitrary initial partition. Results are shown on both synthetic and real images. Quantitative performance evaluation and comparisons are also given.

Algorithms↗

Polarization multiplexing and demultiplexing for appearance-based modeling.

Polarization has been used in numerous prior studies for separating diffuse and specular reflectance components, but in this work we show that it also can be used to separate surface reflectance contributions from individual light sources. Our approach is called polarization multiplexing and it has a significant impact in appearance modeling where the image as a function of illumination direction is needed. Multiple unknown light sources can illuminate the scene simultaneously, and the individual contributions to the overall surface reflectance are estimated. Polarization multiplexing relies on the relationship between the light source direction and the intensity modulation. Inverting this transformation enables the individual intensity contributions to be estimated. In addition to polarization multiplexing, we show that phase histograms from the intensity modulations can be used to estimate scene properties including the number of light sources.

Algorithms↗

The role of viscosity in the impulse diffraction field of elastic waves induced by the acoustic radiation force.

Several ultrasound-based techniques for the estimation of soft tissue elasticity are currently being investigated. Most of them study the medium response to dynamic excitations. Such responses are usually modeled in a purely elastic medium using a Green's function solution of the motion equation. However, elasticity by itself is not necessarily a discriminant parameter for malignancy diagnosis. Modeling viscous properties of tissues could also be of great interest for tumor characterization. We report in this paper an explicit derivation of the Green's function in a viscous and elastic medium taking into account shear, bulk, and coupling waves. From this theoretical calculation, 3D simulations of mechanical waves in viscoelastic soft tissues are presented. The relevance of the viscoelastic Green's function is validated by comparing simulations with experimental data. The experiments were conducted using the supersonic shear imaging (SSI) technique which dynamically and remotely excites tissues using acoustic radiation force. We show that transient shear waves generated with SSI are modeled very precisely by the Green's function formalism. The combined influences of out-of-plane diffraction, beam shape, and shear viscosity on the shape of transient waves are carefully studied as they represent a major issue in ultrasound-based viscoelasticity imaging techniques.

Acoustics↗

Characterization of micromachined ultrasonic transducers using light diffraction tomography.

This paper demonstrates that light diffraction tomography can be used to measure the acoustic field of micromachined ultrasonic transducers (MUT) in cases in which standard methods like hydrophone and microphone measurements fail. Two types of MUTs have been characterized with the method, one air-coupled capacitive MUT (cMUT) and one waterloaded continuous wave (CW) miniature multilayer lead zirconate titanate (PZT) transducer. Light diffraction tomography is an ultrasound measurement method with some special characteristics. Based on the interaction of light and ultrasound, it combines light intensity measurements with tomography algorithms to produce a measurement system. The method offers nonperturbing pressure measurements with high spatial resolution. It has been shown that, under certain circumstances, light diffraction tomography can be used as an absolute pressure measurement method with accuracy in the order of 10% in water and 13% in air. The results show that air-coupled cMUTs in the frequency range of about 1 MHz as well as the extreme near field of a miniaturized CW 10 MHz water-loaded transducer were successfully characterized with light diffraction tomography.

Computer Simulation↗

High frame rate imaging system for limited diffraction array beam imaging with square-wave aperture weightings.

A general-purpose high frame rate (HFR) medical imaging system has been developed. This system has 128 independent linear transmitters, each of which is capable of producing an arbitrary broadband (about 0.05-10 MHz) waveform of up to +/- 144 V peak voltage on a 75-ohm resistive load using a 12-bit/40-MHz digital-to-analog converter. The system also has 128 independent, broadband (about 0.25-10 MHz), and time-variable-gain receiver channels, each of which has a 12-bit/40-MHz analog-to-digital converter and up to 512 MB of memory. The system is controlled by a personal computer (PC), and radio frequency echo data of each channel are transferred to the same PC via a standard USB 2.0 port for image reconstructions. Using the HFR imaging system, we have developed a new limited-diffraction array beam imaging method with square-wave aperture voltage weightings. With this method, in principle, only one or two transmitters are required to excite a fully populated two-dimensional (2-D) array transducer to achieve an equivalent dynamic focusing in both transmission and reception to reconstruct a high-quality three-dimensional image without the need of the time delays of traditional beam focusing and steering, potentially simplifying the transmitter subsystem of an imager. To validate the method, for simplicity, 2-D imaging experiments were performed using the system. In the in vitro experiment, a custom-made, 128-element, 0.32-mm pitch, 3.5-MHz center frequency linear array transducer with about 50% fractional bandwidth was used to reconstruct images of an ATS 539 tissue-mimicking phantom at an axial distance of 130 mm with a field of view of more than 90 degrees. In the in vivo experiment of a human heart, images with a field of view of more than 90 degrees at 120-mm axial distance were obtained with a 128-element, 2.5-MHz center frequency, 0.15-mm pitch Acuson V2 phased array. To ensure that the system was operated under the limits set by the U.S. Food and Drug Administration, the mechanical index, thermal index, and acoustic output were measured. Results show that higher-quality images can be reconstructed with the square-wave aperture weighting method due to an increased penetration depth as compared to the exact weighting method developed previously, and a frame rate of 486 per second was achieved at a pulse repetition frequency of about 5348 Hz for the human heart.

Computer Systems↗

Extended high-frame rate imaging method with limited-diffraction beams.

Fast three-dimensional (3-D) ultrasound imaging is a technical challenge. Previously, a high-frame rate (HFR) imaging theory was developed in which a pulsed plane wave was used in transmission, and limited-diffraction array beam weightings were applied to received echo signals to produce a spatial Fourier transform of object function for 3-D image reconstruction. In this paper, the theory is extended to include explicitly various transmission schemes such as multiple limited-diffraction array beams and steered plane waves. A relationship between the limited-diffraction array beam weighting of received echo signals and a 2-D Fourier transform of the same signals over a transducer aperture is established. To verify the extended theory, computer simulations, in vitro experiments on phantoms, and in vivo experiments on the human kidney and heart were performed. Results show that image resolution and contrast are increased over a large field of view as more and more limited-diffraction array beams with different parameters or plane waves steered at different angles are used in transmissions. Thus, the method provides a continuous compromise between image quality and image frame rate that is inversely proportional to the number of transmissions used to obtain a single frame of image. From both simulations and experiments, the extended theory holds a great promise for future HFR 3-D imaging.

Algorithms↗

Interactive approximate rendering of reflections, refractions, and caustics.

Reflections, refractions, and caustics are very important for rendering global illumination images. Although many methods can be applied to generate these effects, the rendering performance is not satisfactory for interactive applications. In this paper, complex ray-object intersections are simplified so that the intersections can be computed on a GPU, and an iterative computing scheme based on the depth buffers is used for correcting the approximate results caused by the simplification. As a result, reflections and refractions of environment maps and nearby geometry can be rendered on a GPU interactively without preprocessing. We can even achieve interactive recursive reflections and refractions by using an object-impostor technique. Moreover, caustic effects caused by reflections and refractions can be rendered by placing the eye at the light. Rendered results prove that our method is sufficiently efficient to render plausible images interactively for many interactive applications.

Algorithms↗

Refractive index-based determination of detergent concentration and its application to the study of membrane proteins.

The concentration of detergent in membrane protein preparations can have a critical role on protein stability, function, and the potential for crystallization. Unfortunately, dialysis or protein concentration can lead to an unknown amount of detergent in the final membrane protein preparations. Here we present a method for the determination of detergent concentration based on refractive index of the detergent solution. This method was applied to quantitate the amount of detergent remaining in solution after concentration in various concentrators. We found that the ability of the tested detergents to pass through the molecular weight cutoff membrane correlates well with detergent micelle size. Therefore, the micelle size can be used as a rough guide to estimate the retention of a given detergent in various molecular weight cutoff concentrators. The refractive index method is exceptionally informative when coupled with size exclusion chromatography and light scattering, and can be used to determine the oligomeric state of the membrane protein, the size of a protein-associated micelle, as well as the amount and size of the unbound detergent micelle.

Chromatography, Gel↗

Skin color measurements in terms of CIELAB color space values.

The principles of color measurement established by the Commission International d'Eclairage have been applied to skin and the results expressed in terms of color space L*, hue angle, and chroma values. The distribution of these values for the ventral forearm skin of a sample of healthy volunteers is presented. The skin-color characteristics of a European subgroup is summarized and briefly compared with others. Color differences between individuals were identified in terms of one, two, or all three color-space parameters. Because the method is quantitative and the principles internationally recognized, these color-space parameters are proposed for the unambiguous communication of skin-color information that relates directly to visual observations of clinical importance or scientific interest.

Adult↗

Evaluation of the epidermal refractive index measured by optical coherence tomography.

BACKGROUND/AIMS: It has recently been proposed that the refractive index (RI) measured by means of optical coherence tomography (OCT) may be a valid measure for hydration of skin. In this pilot study, using OCT in vivo, we aimed to investigate the interday variability of RI measurements and acute changes of RI following the application of a moisturizer. METHODS: Twenty healthy Caucasian volunteers were investigated on their forearms using a commercially available OCT system (SkinDex 300, ISIS optronics GmbH, Mannheim, Germany) fitted with an integrated algorithm for the evaluation of the RI. The interday repeatability of the OCT method was determined performing symmetrical measurements on both forearms on day 1, 5, 9, and 13. In order to investigate the acute effect of a moisturizer on RI, OCT assessments were performed before and 10 min after the application of an aqueous lotion with a lipophilic phase. As a control, the contralateral site was investigated in the same way, except for the use of distilled water instead of the lotion. RESULTS: Assessments of interday variability revealed insignificant (P>0.05) variances between the four measurement times as expressed in very small repeatability coefficients (right arm: 0.039; left arm 0.053) and small coefficients of variance (right arm: 1.02%; left arm: 1.38%). With regard to the RIs measured over time, we could not observe significant (P>0.05) differences between the two symmetrical anatomic sites (mean+/-SD of RI: 1.3893+/-0.0142 (right arm); 1.3875+/-0.0192 (left arm)). The acute effect of the moisturizer was indicated by a significant decrease of the RI 5 min after the application of the lotion (1.399+/-0.01 vs. 1.387+/-0.02; difference between means: 0.012; P=0.033; 95% confidence interval: 0.001-0.0023). However the control site treated with distilled water did not show significant differences between the two measurement times (1.387+/-0.013 vs. 1.391+/-0.023; difference between means: -0.004; P=0.57; 95% confidence interval: -0.019-0.011). CONCLUSIONS: In this pilot study, we have demonstrated that RI evaluation via OCT is a promising technique that may be used for the assessment of skin hydration in vivo. However, the direct comparison of OCT with standard methods, ideally such as nuclear magnetic resonance spectroscopy, is necessary.

Adult↗

The use of a portable refractometer to measure desflurane.

The measurement of volatile anaesthetic agents by infrared absorption is liable to interference by other gases which absorb infrared light. In particular, nitrous oxide may, in principle, interfere with the measurement of desflurane. On the other hand, the refractometer should be immune to such effects. We demonstrated that interactions may occur between desflurane and nitrous oxide with some gas analysers and that the refractometer remains a useful instrument.

Anesthetics↗

A scanning microinterferometer with correction of errors caused by overlapping 'ghost' images.

An experimental setup has been built to correct the errors caused by overlapping 'ghost' images when scanning and integrating measurements are carried out with the Jamin-Libedef interference microscope. First a reference field with the object, producing the 'ghost' image, is scanned and the values of the optical path difference (OPD) of each point in the reference field are stored in a computer. Subsequently, the OPD of the object to be measured is calculated for each point by adding the measuring result to the average OPD of five points, located around the corresponding point in the reference field. The applicability of the setup has been tested by measurements with Sepharose beads, Hela cells and the Zeiss microinterference refractometer. The difference between measurements on the same object with and without overlapping 'ghost' image was about 10%. The reproducibility was tested by repeated measurements on the same cell whereby a standard deviation of 1.1% was found.

Computers↗