Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Reagent Strips”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Comparative evaluation of a new bedside faecal occult blood test in a prospective multicentre study.

BACKGROUND: Faecal occult blood testing is an established method of colorectal neoplasia screening. Guaiac-based tests are limited by poor patient compliance, low sensitivity, specificity and positive predictive value. Newer immunochemical-based tests, accurate but tedious, require a well-established laboratory set up. There is need for simpler immunochemical tests that can be performed at the out-patient clinic. AIM: To compare the performance characteristics of a new bedside immunological test strip device with a sensitive Guaiac-based and established immunochemical test for detection of faecal occult blood in patients undergoing colonoscopy. METHODS: A total of 389 consecutive patients from four centres who were referred for colonoscopy also provided the stool samples for detection of occult blood without dietary restrictions. Stool tests performed were (i) Guaiac-based, (ii) immunochemical enzyme-linked immunosorbent assay and (iii) bedside immunochemical strip test. RESULTS: At the optimal threshold level, the sensitivity and specificity of the beside immunochemical strip test for detection of significant colorectal neoplasia (adenomas >1.0 cm and carcinomas) were 60% and 95%, respectively. CONCLUSIONS: This bedside immunochemical strip test proved to be a simple, convenient, non-cumbersome and accurate tool with similar performance characteristics for detection of any bleeding lesion including colorectal neoplasia when compared with an established immunochemical faecal occult blood test.

Adolescent↗

Black teeth: beauty or caries prevention? Practice and beliefs of the Kammu people.

BACKGROUND: To be beautiful and caries-free, Kammu women in Laos and Vietnam habitually paint their teeth black. Although this practice existed for many generations, it is now known only among the elderly. OBJECTIVES: To describe how the tooth-blackening procedure is performed and to test the black stain for possible antimicrobial effects in laboratory experiments. METHODS: Information on how to blacken teeth was obtained by interviewing groups of elderly Kammu people living in different villages in Laos and Vietnam. Water extracts of the stain were placed in wells in agar plates and the plates incubated with Streptococcus mutans or S. sobrinus. The stain was also let such that it covered half of the strip test-side of the Dentocult SM Strip Mutans test kit and incubated with saliva from five persons known to carry mutans streptococci in their saliva. RESULTS: Interviews revealed that three plants were commonly used: Dracontomelon dao nuts (DD nuts), Cratoxylum formosum (CF) wood or Croton cascarilloides (CC) wood. The parts (nut, wood) were burned and soot collected on metal plates. The fresh soot, which had a viscous consistency, was applied to teeth with the index finger. Extracts of soot of the DD nuts had no effect on the streptococci on agar plates but inhibited the growth of salivary mutans streptococci on strips. Controls using soot from birch tree (Betula pendula) had no effect. CONCLUSIONS: The procedure was simple and resulted in black, beautiful (?) teeth. The soot of DD nuts effectively inhibited growth of salivary mutans streptococci in in vitro experiments.

Anacardiaceae↗

Detection of canine microalbuminuria using semiquantitative test strips designed for use with human urine.

BACKGROUND: Commercial testing for microalbuminuria in human urine is often performed with point-of-care semiquantitative test strips followed by quantitative testing when indicated. An ELISA that quantifies canine urine albumin concentration has been developed, but semiquantitative test strips for use in the dog are not available. OBJECTIVE: The purpose of this study was to prospectively determine the concordance of canine urine albumin concentrations measured by a commercial human test strip and by ELISA. METHODS: Urine samples were obtained from 67 dogs evaluated for a variety of clinical conditions. Dipstick urinalyses were performed on all samples; clinician discretion determined method of urine collection and performance of urine sediment examination and/or urine culture. Urine albumin concentration was determined using test strips (Clinitek Microalbumin, Bayer Corporation, Elkhart, Ind, USA), and results were compared with those obtained by ELISA. RESULTS: The Clinitek strips correctly determined albumin concentration in 42 of 67 (63%) urine samples tested. Concordance was lowest (48%) for dogs with microalbuminuria (10-300 microg/mL by ELISA). Clinitek strip sensitivity and specificity for correct identification of microalbuminuria were 48% and 75%, respectively. Concordance was lower in dogs with urinary tract infection or hematuria and in samples collected by catheterization. Sensitivity and specificity for correct identification of microalbuminuria after exclusion of dogs with urinary tract infection or hematuria were 59% and 83%, respectively. CONCLUSIONS: These results suggest that the Clinitek strips lack sufficient concordance with results obtained by ELISA to be a reliable screening for test microalbuminuria in the dog. A reliable semiquantitative point-of-care test for canine urine albumin concentrations below those detected by standard urine dipsticks is still needed.

Albuminuria↗

[Rapid demonstration of urinary leucocytes with a new leucocyte test-strip. A multicentre cooperative study (author's transl)].

In a study in which eight centres from Austria, France, Germany and Switzerland cooperated anew test-strip for urinary leucocytes was compared with chamber counts of uncentrifuged urine, on a total of 3183 urine samples. There was good agreement between the teststrip and reference test as to sensitivity and clinical significance, and no significant difference to the Cytur-Test, which is already commercially available. However, one advantage of the new test is that the reaction time is shortened to one minute, so that it can be used in combination test-strips (Combur-Test), thus providing uniform reading-off time and measurement by reflexion-photometry. There is no interference by ascorbic acid, but albumin and serum proteins in higher concentrations weaken the colour reaction. Urine-preserving formaldehyde-containing additives produce false-positive reactions. Alpha-methyldopa, salicylic acid, beta-hydroxybutyric acid and acetoacetic acid have no influence.

Ascorbic Acid↗

Urinary trypsinogen-2 test strip in detecting ERCP-induced pancreatitis.

BACKGROUND AND STUDY AIMS: We have evaluated a new urinary trypsinogen-2 test strip, based on the principle of immunochromatography, in the diagnosis of acute pancreatitis induced by endoscopic retrograde cholangiopancreatography (ERCP). PATIENTS AND METHODS: One hundred six consecutive patients undergoing ERCP (with opacification of the pancreatic duct) at the Helsinki University Central Hospital were included in the study. Patients were tested with a urinary trypsinogen-2 test strip six hours after ERCP. Quantitative trypsinogen-2 as well as serum and urine amylase values were measured before the procedure and six hours after it. RESULTS: In patients developing pancreatitis after ERCP, the median urinary trypsinogen-2 concentration six hours after the endoscopic procedure was 1780 micrograms/l (range 29-10,700 micrograms/l), and in patients without pancreatitis the median concentration was 3.6 micrograms/l (range 0.1-3390 micrograms/l; P < 0.0001). The sensitivity and specificity figures for the urinary trypsinogen-2 test strip results in diagnosing post-ERCP pancreatitis were comparable (81% and 97%, respectively) to those for serum amylase (91% and 96%) and urine amylase measurements (81% and 95%). The test strip showed a good correlation (kappa = 0.75) with the quantitative trypsinogen-2 assay. CONCLUSIONS: The increase in urinary trypsinogen-2 concentration after ERCP reflects pancreatic injury, and can be detected by the test strip. Patients should be tested before the ERCP procedure as well, since elevated baseline values occur. The test is reliable and easy to perform even on an outpatient basis. However, its clinical usefulness requires evaluation in further trials.

Acute Disease↗

Development and evaluation of an antigen detection dipstick assay for the diagnosis of human onchocerciasis.

To improve on the diagnosis of onchocerciasis, especially light infections, we developed and evaluated an oncho-dipstick test based on the detection of Onchocerca volvulus specific antigens in urine and tears. The test was able to detect as little as 25 ng/ml of parasite specific antigens in samples and took as little as 3 h. Evaluation of the assay on 456 residents of an onchocerciasis hyperendermic area in Cameroon resulted in 408 (89.5%) positives in urine and 374 (82%) positives in tears. The prevalence of onchocerciasis in the study area, as determined by Rapid Epidemiological Mapping of Onchocerciasis (REMO) and skin snip methods, was 52 and 36.8%, respectively. The sensitivity of the oncho-dipstick assay was 100% in urine and 92% in tears; its specificity was 100% in both. Concordance between urine and tear test results from the same individuals was 87%. The test strips were sufficiently reactive when left at room temperature for up to 8 months. The test would be useful for laboratory diagnosis of onchocerciasis in low transmission zones and to ascertain successful treatment of patients in experimental drug studies.

Animals↗

Reliability of two novel methods, Alamar and E test, for detection of methicillin-resistant Staphylococcus aureus.

E test strips (AB Biodisk, Culver City, Calif.) tested on 2% NaCl-supplemented Mueller-Hinton agar and Alamar panels (Alamar, Sacramento, Calif.) correctly characterized 127 of 127 methicillin-resistant Staphylococcus aureus isolates and 100 of 100 methicillin-susceptible S. aureus isolates. These overnight antimicrobial susceptibility test systems reliably detect this clinically important resistance.

Drug Resistance, Microbial↗

Detection of volatile sulfide-producing bacteria isolated from poultry-processing plants.

A technique using filter paper strips impregnated with 5-5'-dithiobis-nitrobenzoic acid was developed to allow the detection of bacteria (isolated from poultry-processing environs) which produced volatile sulfides (H2S, CH3SH, [CH3]2S). The technique is preferred to conventional methods in that it allows the detection of volatile organic sulfides in addition to hydrogen sulfide.

Animals↗

False negative hyperglucosuria test-strip reactions in laboratory mice.

Inhibition of a variety of commercial test strips for hyperglucosuria was experienced in laboratory mice. All mouse strains tested were found to have sufficiently high levels of ascorbic acid to cause inhibition, and male levels were higher than those of females. A regime to obtain optimum detection of positive results is discussed.

2,6-Dichloroindophenol↗

Evaluation of a rapid theophylline test strip assay in the emergency department setting.

Test strips recently have become available to measure theophylline levels. One such test strip (AccuLevel) had not been tested in an actual clinical situation with nontechnician personnel. We prospectively evaluated the test strip on consecutive emergency department patients, comparing it with the agglutination inhibition method used by our hospital laboratory. Nurses and medics who ran the test were given only a brief demonstration and explanation of the manufacturer's instructions. The 61 test strip levels correlated highly with the laboratory results (r = 0.92, slope = 0.89, y-intercept = 0.99). The test strip results were available in less time (mean of 0.51 hours vs 1.89 hours for the laboratory, P less than .0001). The most accurate readings were obtained by those who ran the test most frequently. Caffeine intake did not influence the test. Cost was significantly lower than charges at local hospitals.

Caffeine↗

Influence of transient salivary flora on assessment of mutans streptococci level by the "Strip mutans" method.

The Dentocult SM ("Strip mutans") method occasionally shows decoloration of broth and of colonies of mutans streptococci on the plastic strip, thereby making interpretation difficult. In an attempt to explain the phenomenon and to investigate the influence of the salivary flora on the "Strip mutans" method, a total of 46 subjects were sampled. Saliva was analyzed using the "Strip mutans" method and conventional plating techniques to identify mutans streptococci, enterococci, staphylococci, enteric bacteria, and yeasts. Approximately 85% of the "Strip mutans" scores coincided with the conventional MSB-plating method. Two samples showed decolored mutans streptococci colonies on the "Strip mutans" strip. Enterococcus spp. were present in the saliva of these test subjects and could grow in the "Strip mutans" broth. Enterococcus faecalis was able to induce the same type of decoloration under experimental pure culture conditions. Three "Strip mutans" samples showed small colonies of mutans streptococci, visible only under magnification (x 10-20). Staphylococcus epidermidis was present in these saliva samples and showed heavy growth in the broth. Under experimental pure culture conditions S. epidermidis also inhibited the growth of mutans streptococci to some extent.

Adult↗

Salivary urea nitrogen as an index to renal function: a test-strip method.

To investigate the feasibility of using salivary urea nitrogen as an index of renal glomerular filtration rate, we developed and applied a new analytical system consisting of a urease-containing test strip and an automatic reflectance spectrometer. The concentrations of urea nitrogen so determined correlate well (r = 0.93) with concentrations in serum. These preliminary data suggest that our method can be used routinely as a simple and reliable means of detecting abnormalities of renal function.

Adolescent↗

Human stratum corneum penetration by nickel. In vivo study of depth distribution after occlusive application of the metal as powder.

Sequential tape stripping was implemented on three healthy volunteers to examine the surface distribution of nickel through human stratum corneum in vivo following occlusive application of the metal as powder on the volar forearm. Exposure sites were stripped 20 times at intervals from 5 min to 96 h post-dosing and the strips analyzed for metal content by Inductively Coupled Plasma-Mass Spectroscopy with a detection limit for nickel of 0.5 ppb. The gradients of nickel distribution profiles increased proportionally with occlusion time, but after the 10th strip to the 20th strip continued at constant levels. Total nickel removed with 20 stratum corneum strips to the level of the glistening layer after maximum occlusion of 96 h was 41.6 micrograms/cm2 (+/- 12.2; average n = 3). In order to normalize the nickel depth distribution profiles, stratum corneum removed by stripping of untreated skin after occlusion was determined by weighing. Following application of nickel dust over 24 h, analysis of the 20th strip still indicated nickel present at 1.42 micrograms/cm2 (+/- 0.68; average n = 3). These data indicate that, in contact with skin, nickel metal is oxidized to form soluble, stratum corneum-diffusible compounds which may penetrate the intact stratum corneum, presumably by the intercellular route, and have the potential to elicit allergic reactions.

Adult↗

Histochemical technique to detect choline-containing lipids.

An almost specific and highly sensitive technique to detect histochemically choline-containing lipids is proposed. This technique is based on the effect of Hg++ and phosphomolybdic ion on the choline, that yields insoluble complexes able to react with diphenylcarbazide producing a deep blue or violet stain. The specificity and the sensitivity of this technique was investigated on filter paper strips loaded with choline-containing lipids, choline-free lipids, steroids, vitamins, proteins or choline hydrochloride. The results show that the choline-containing substances react positively. The choline-free substances react negatively except calciferol and vitamin A that show weakly positive results. This technique used on tissue sections appears very suitable to histochemical purposes.

Adrenal Glands↗

The correspondence between saliva and breath estimates of blood alcohol concentration: advantages and limitations of the saliva method.

Increased awareness of the devastating effects of alcohol misuse on our highways, workplaces and families, as well as on the individual, has resulted in increased social pressure to enforce driving-while-intoxicated laws and to develop educational, prevention and treatment programs. One aspect of this movement is to develop improved sobriety testing to ensure that laws are properly and fairly enforced and that there is compliance with abstinence in treatment. Although sophisticated blood and breath testing devices are available, field tests suggest that saliva alcohol tests based on alcohol-oxidase methodology offer advantages in portability, ease of administration, and cost and time efficiency. We evaluated the validity and reliability of a simple saliva test, based on the enzymatic oxidation of alcohol by alcohol oxidase, for estimating blood alcohol concentration. Ten subjects consumed various doses of alcohol and multiple saliva samples were obtained using alcohol sensitive saliva strips that change color in proportion to the concentration of alcohol. The reflectance values of reacted saliva strips were read by meter and estimates of blood alcohol concentration in the range of 10-90 mg/dl were compared to simultaneous estimates obtained from breath analysis using a Breathalyzer Model 900A. We also examined how alcohol levels changed over time in alcohol reacted saliva strips. The results of regression analysis indicated that the saliva strips and the Breathalyzer gave reasonably close estimates (r = 0.89-.90) of blood alcohol concentration. Correlation coefficents for the values of saliva samples read by meter measured at 10 minutes and at 18 days after collection ranged from .90 to 1.00, showing high test-retest reliability despite storage.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Applicability of leukocyte esterase test strip in detection of canine pyuria.

A commercially available leukocyte esterase assay was evaluated for application in analyzing canine urine for the detection of pyuria. In 229 urine samples, the leukocyte esterase activity was compared with leukocyte concentrations, as assessed by microscopic sediment analysis and chamber cell counts. The leukocyte esterase assay was specific (93.2%) for canine pyuria, but was poorly sensitive (46.0%) and did not appear to be applicable to analysis of canine urine samples.

Animals↗

Evaluation of a simplified method for site-specific determination of mutans streptococci levels.

To determine the oral mutants streptococcal "load" of an individual, saliva samples reflecting the number of colonized tooth surfaces, are often applied. Sometimes a plaque sample from a specific site would be an advantage, for example in connection with local antimicrobial treatments. The aim of the present paper was to evaluate a chairside method for determination of mutans streptococci interproximally. One hundred subjects participated. Four approximal tooth surfaces of each individual were sampled using toothpicks. The toothpicks were then let to contaminate a pad on a specially designed plastic strip and, for comparison, a MSB-agar plate. The strips were incubated in the standard "Strip mutans" broth. The yield of colony forming units on the strip surface corresponded significantly with that on agar plates. Being a simple chair-side method for the evaluation of the site-specific load of mutans streptococci, it is suggested that the method will be used in various investigations to clarify its potential in different clinical situations.

Adult↗

[Symptomatic urinary tract infection of the female--diagnostics].

The basis for the diagnostic work-up of recurrent cystitis is formed by taking a precise medical history against the background of knowledge of the pathogenesis of urinary tract infections. The anamnesis should also focus on factors that influence the natural flora (sexual intercourse, hygiene) but additionally include preceding antibiotic treatment and diseases that affect the immune status (diabetes mellitus). Urinalysis is the principal examination among the laboratory diagnostic procedures. The diagnosis is promptly confirmed by immediate analysis of a clean catch midstream urine sample using a counting chamber or a test strip. As a matter of principle, microbiological diagnosis always ensues. Extended diagnostic work-up (urological staging) is aimed at detecting functional and anatomic abnormalities. While these factors only play a subordinate role during the premenopausal phase, they gain in importance during the postmenopausal phase. A key role is also attributed to local estrogen deficiency.

Anti-Infective Agents, Urinary↗