Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIO”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Effects of exposure to a 1950 MHz radio frequency field on expression of Hsp70 and Hsp27 in human glioma cells.

Human glioma MO54 cells were used to investigate whether radio frequency (RF) field exposure could activate stress response genes. Cells were exposed to continuous wave 1950 MHz or sham conditions for up to 2 h. Specific absorption rates (SARs) were 1, 2, and 10 W/kg. For the cell growth experiment, cell numbers were counted at 0-4 days after exposure. Expression of Hsp27 and Hsp70, as well as the level of phosphorylated Hsp27 (78Ser) protein, was determined by Western blotting. It was found that sham exposed and RF exposed cells demonstrated a similar growth pattern up to 4 days after RF field exposure. RF field exposure at both 2 and 10 W/kg did not affect the growth of MO54 cells. In addition, there were no significant differences in protein expression of Hsp27 and Hsp70 between sham exposed and RF exposed cells at a SAR of 1, 2, or 10 W/kg for 1 and 2 h. However, exposure to RF field at a SAR of 10 W/kg for 1 and 2 h decreased the protein level of phosphorylated Hsp27 (78Ser) significantly. Our results suggest that although exposure to a 1950 MHz RF field has no effect on cell proliferation and expression of Hsp 27 and Hsp70, it may inhibit the phosphorylation of Hsp27 at Serine 78 in MO54 cells.

Cell Line, Tumor↗

Perturbations of plant leaflet rhythms caused by electromagnetic radio-frequency radiation.

The minute-range up and down rhythms of the lateral leaflets of Desmodium gyrans has been studied when exposed to electromagnetic radiation in the radio-frequency (RF) range. The RF radiation was applied as homogeneous 27.12 MHz fields in specially-designed exposure cells(and in some cases as non-homogeneous radiation of 27 MHz, amplitude modulated by 50 Hz, in front of commercial diathermy equipment). All fields were applied as pulses. We report effects in the leaflet rhythms such as temporary changes in the amplitude, period, and phase. The radiation could also cause temporary or complete cessations of the rhythms. The lowest dose (8 W/cm2) used was still effective.

Electromagnetic Fields↗

Intramyocardial delivery of FGF2 in combination with radio frequency transmyocardial revascularization.

Therapeutic angiogenesis and percutaneous transmyocardial revascularization (PMR) are potentially synergistic modalities to improve myocardial perfusion. To evaluate the efficiency of FGF2 delivery into an area that has been radio frequency (RF) ablated, we studied two catheter-based delivery methods, a direct injection system (Stiletto) and a combined RF ablation-delivery system (RF-PMR). Four groups (n = 3/group) of pigs received six transendocardial injections of (125)I-FGF2/fluorescent microspheres with either the Stiletto or the RF-PMR catheter. RF-PMR injections were preceded by a 0.6 sec RF ablation step. After either 1 or 24 hr, hearts and other tissues were harvested. Intramyocardial deposition sites were located with UV light and isolated. Specific activity per site was expressed as a percentage of total activity injected per site corrected for quenching. Injection site recovery was high for both catheter systems (average = 88%) and systemic uptake was low (< 6% in the liver). FGF2 retention was significantly higher with the Stiletto than the RF-PMR catheter (Stiletto 1 hr 41% +/- 17%, 24 hr 26% +/- 10%, RF-PMR 1 hr 21% +/- 14%, 24 hr 13% +/- 8%; P < 0.001), principally explained by the differences in catheter design. The Stiletto has a retractable needle and is optimized for intramyocardial delivery, whereas infusion from the RF-PMR device occurs at the endocardial surface and relies on channels created during RF ablation. Overall, FGF2 retention after transendocardial intramyocardial delivery by the Stiletto or the RF-PMR system is significantly higher than previously observed for intracoronary, intravenous and intrapericardial delivery. In conclusion, the combination of RF ablation and growth factor delivery using the RF-PMR system is feasible and efficient. Cathet Cardiovasc Intervent 2001;53:429-434.

Animals↗

Intraperitoneal radio-localization of tumors pre-targeted by biotinylated monoclonal antibodies.

We describe 2-step and 3-step strategies for intraperitoneal tumor radio-localization by means of monoclonal antibodies (MAbs). Nude mice bearing intraperitoneal human colon carcinoma tumors were injected i.p. with biotinylated MAb AUAI, followed 24 hr later by radioiodinated streptavidin (2-step). The uptake of radioactivity in tumor and normal tissues was measured 4 hr after injection of radioactive compound. A 3-step strategy consisted in administering biotinylated antibody, cold avidin after 24 hr and 111In-labelled biotin after a further 4 hr; mice were then killed 2 hr later. Tumor localization of intraperitoneally-administered biotinylated antibody and direct targeting of radioactive streptavidin to biotinylated antibody bound to tumor sites were demonstrated using immunohistochemistry and autoradiography. Our results show that (i) the 2-step approach increased the percentage of radioactivity uptake by tumor with respect to directly labelled antibodies (24% vs. 6%) and improved the tumor/non-tumor ratio; (ii) the 3-step approach allowed faster blood clearance of the radioactive probe (111In-biotin) and yielded high tumor/non-tumor ratios. "Pre-targeting" methods appear to have advantages over the conventional 1-step approach with directly radiolabelled antibody.

Animals↗

Tumor-necrosis factor can enhance radio-antibody uptake in human colon carcinoma xenografts by increasing vascular permeability.

Marked differences in the tumor uptake of a 125I-labeled monoclonal antibody (MAb) directed against carcinoembryonic antigen (CEA) were observed in 4 serially transplanted human colorectal carcinomas in nude mice. A comparative study showed that elevated values of measurable tumor vascular parameters, such as permeability, blood flow and blood volume, correlated better with high MAb tumor uptake than the concentration of target antigen in the tumor. In an attempt to modify the vascular parameters and to determine if this could increase antibody uptake by the tumor, rhTNF alpha (TNF) was injected i.t. or i.v. and antibody localization experiments were performed immediately thereafter. Results showed that the permeability of the tumor vessels increased 8 to 10 fold 1 hr after i.t. injection of TNF as compared to control tumors injected with saline. Tumor uptake of 125I-labeled anti-CEA MAb, was 3 times higher 2 hr after i.v. injection and still 27% higher 22 hr later, as compared to results from controls. Intravenous injection of TNF simultaneously with the 125I-labeled anti-CEA MAb also resulted in a 2-fold increase in tumor uptake 4 hr after injection, but the increase was no longer significant 24 hr after injection. Interestingly after i.v. injection of TNF, the MAb concentration in the blood and other normal tissues, such as liver, kidneys, lungs and heart was decreased, resulting in significantly higher ratios of tumor to normal tissue. Taken together the results demonstrate that injection of TNF can increase tumor vascular permeability and improve radio-antibody uptake. This raises the possibility of increasing the radiation dose delivered by antibody to the tumor in the course of radioimmunotherapy.

Animals↗

Radio-frequency-induced thermal lesions: subacute magnetic resonance appearance and histological correlation.

PURPOSE: To investigate the relationship between subacute magnetic resonance (MR) images of radio-frequency (RF) ablation lesions and tissue viability as determined from histological tissue samples. MATERIALS AND METHODS: We generated lesions (N = 5) in a rabbit thigh model. Four days later, we obtained in vivo T(2)- and contrast-enhanced (CE) T(1)-weighted images and ex vivo histological samples approximately perpendicular to the electrode path. Using three-dimensional registration and warping, we spatially compared manually segmented boundaries apparent on MR images to boundaries separating distinct histological zones determined from hematoxylin and eosin (H&E) and Masson trichrome (MT) stains, as well as birefringence studies. RESULTS: Lesions have a characteristic MR appearance: an outer hyperintense margin (M2) separating background tissue (M3) from an inner core (M1), in both T(2) and CE T(1) images. Histologically, there are two zones of damage: an outer zone of likely nonviable cells (H2) separating background tissue (H3) from an inner core of coagulated nonviable cells (H1). We measured distances between automatically computed correspondence points along histological and MR boundaries. For T(2) and CE T(1) images, respectively, M1 vs. H1 distances were 0.72 +/- 0.99 mm (mean +/- SD) and 0.10 +/- 0.95 mm, while outer M2 vs. H2 boundary distances were 0.26 +/- 1.16 mm and 0.05 +/- 1.08 mm. The discrepancy between histological and MR boundaries was larger than the variability in segmenting MR images, but probably within registration error. There were no significant differences between T(2) and CE T(1) boundaries. CONCLUSION: Lesion boundaries apparent in both T(2)- and CE T(1)-weighted MR scans, performed several days postablation, similarly predict the histological response. That is, the lesion core (M1) corresponds to nonviable coagulated cells (H1), while the hyperintense margin (M2) corresponds to likely nonviable cells undergoing necrotic changes (H2).

Animals↗

Automatic model-based evaluation of magnetic resonance-guided radio frequency ablation lesions with histological correlation.

PURPOSE: To develop a model-based method for automatic evaluation of radio frequency (RF) ablation treatment using magnetic resonance (MR) images. MATERIALS AND METHODS: RF current lesions were generated in a rabbit thigh model using MR imaging (MRI) guidance. We created a 12-parameter, three-dimensional, globally deformable model with quadric surfaces that delineates lesion boundaries and is automatically fitted to MR grayscale data. We applied this method to in vivo T2- and contrast-enhanced (CE) T1-weighted MR images acquired immediately post-ablation and four days later. We then compared results to manually segmented MR and three-dimensional registered corresponding histological boundaries of cellular damage. RESULTS: Resulting lesions featured a two-boundary appearance with an inner region and an outer hyperintense margin on MR images. For automated vs. manual MR boundaries, the mean errors over all specimens were 0.19 +/- 0.51 mm and 0.27 +/- 0.52 mm for the inner surface, and -0.29 +/- 0.40 mm and -0.12 +/- 0.17 mm for the outer surface, for T2- and CE T1-weighted images, respectively. For automated vs. histological boundaries, mean errors over all specimens were 0.07 +/- 0.64 mm and 0.33 +/- 0.71 mm for the inner surface, and -0.27 +/- 0.69 mm and 0.02 +/- 0.43 mm for the outer surface, for T2- and CE T1-weighted images, respectively. All boundary errors compared favorably to MR voxel dimensions, which were 0.7 mm in-plane and 3.0 mm thick. CONCLUSION: The method is accurate both in describing MR-apparent boundaries and in predicting histological response and has applications in lesion visualization, volume estimation, and treatment evaluation.

Algorithms↗

Ultrastructural evaluation of multiple pass low energy versus single pass high energy radio-frequency treatment.

BACKGROUND AND OBJECTIVE: The radio-frequency (RF) device is a system capable of volumetric heating of the mid to deep dermis and selective heating of the fibrous septa strands and fascia layer. Clinically, these effects promote dermal collagen production, and tightening of these deep subcutaneous structures. A new technique of using multiple low energy passes has been described which results in lower patient discomfort and fewer side effects. This technique has also been anecdotally described as giving more reproducible and reliable clinical results of tissue tightening and contouring. This study will compare ultrastructural changes in collagen between a single pass high energy versus up to five passes of a multiple pass lower energy treatment. STUDY DESIGN/MATERIALS AND METHODS: Three subjects were consented and treated in the preauricular region with the RF device using single or multiple passes (three or five) in the same 1.5 cm(2) treatment area with a slight delay between passes to allow tissue cooling. Biopsies from each treatment region and a control biopsy were taken immediately, 24 hours or 6 months post treatment for electron microscopic examination of the 0-1 mm and 1-2 mm levels. Sections of tissue 1 mm x 1 mm x 80 nm were examined with an RCA EMU-4 Transmission Electron Microscope. Twenty sections from 6 blocks from each 1 mm depth were examined by 2 blinded observers. The morphology and degree of collagen change in relation to area examined was compared to the control tissue, and estimated using a quantitative scale. RESULTS: Ultrastructural examination of tissue showed that an increased amount of collagen fibril changes with increasing passes at energies of 97 J (three passes) and 122 J (five passes), respectively. The changes seen after five multiple passes were similar to those detected after much more painful single pass high-energy treatments. CONCLUSIONS: This ultrastructural study shows changes in collagen fibril morphology with an increased effect demonstrated at greater depths of the skin with multiple low-fluence passes and at lesser depths with single pass higher fluence settings. Findings suggest that similar collagen fibril alteration can occur with multiple pass low-energy treatments and single pulse high-energy treatments. The lower fluence multiple pass approach is associated with less patient discomfort, less side effects, and more consistent clinical results.

Collagen↗

Optimal pressure conditions for unbiased external ion accumulation in a two-dimensional radio-frequency quadrupole for Fourier transform ion cyclotron resonance mass spectrometry.

When combined with on-line separations (e.g., capillary liquid chromatography (LC)), Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) provides a powerful tool for biological applications, and particularly proteomic studies. The sensitivity, dynamic range, and duty cycle provided by FTICR-MS have been shown to be increased by ion trapping and accumulation in a two-dimensional (2D) radio-frequency (rf)-only multipole positioned externally to an FTICR cell. However, it is important that ions be detected across the desired m/z range without a significant bias. In this work we found that pressure inside the accumulation rf-quadrupole plays an important role in obtaining "unbiased" ion accumulation. Pressure optimization was performed in both pulsed and continuous modes. It was found that unbiased accumulation in a 2D rf-only quadrupole could be achieved in the pressure range of 5 x 10(-4) to 5 x 10(-3) Torr. External ion accumulation performed at the optimal pressure resulted in an increase in both the spectrum acquisition rates and dynamic range.

Algorithms↗

Habitat-contingent reproductive behaviour in radio-implanted salamanders: a model and test.

All tiger salamanders, Ambystoma tigrinum, entering a small pond in New York state were given radio-implants and tracked throughout breeding to determine whether reproductive behaviour in nature differs from that described in laboratory studies. I formed an extended model of adult reproductive behaviour that included male and female strategies and differential use of habitat components in the breeding pond, and then tested four key predictions regarding adult movement using the sequence of positions of all salamanders between pond entry and exit. An unexpected, female-biased sex ratio during most courtship activity led to departures from the predicted behaviour, but in all other respects the behaviour of the males and females followed from the predictions. Apparent mate scanning in clear water, and weather assessment in pond-edge shallows just prior to emergence, are new indications for caudate amphibians. Copyright 1998 The Association for the Study of Animal Behaviour. Copyright 1998 The Association for the Study of Animal Behaviour.

Journal Article↗

Radio-Frequency, Centimeter-Wave, Millimeter-Wave, and Infrared Spectra of SiDF(3) in the v(6) = 1 Excited State.

This paper deals with the first study of high-resolution radio-frequency, centimeter-wave, millimeter-wave, and infrared spectra of the deuterated isotopomer of trifluorosilane, SiDF(3), in its lowest degenerate excited v(6) = 1 state. Following the work of E. I. Lobodenko, O. N. Sulakshina, V. I. Perevalov, and Vl. G. Tyuterev, (J. Mol. Spectrosc. 126, 159-170 (1987)) and Harder (J. Mol. Spectrosc. 194, 145 (1999)), the data (18 A(1)-A(2) transitions, 229 l-type resonance transitions, 189 pure rotational transitions, and 1167 rovibrational transitions) have been fitted using three equivalent Q, D, and QD reduction schemes enabling the fit of one of the three interaction parameters d, q(12), and epsilon, respectively, while the other two are fixed to zero. In addition to further higher order constants, either f(K)(22) or tau(K) also had to be constrained. By checking the standard deviation of each data set and the relations between parameters determined within different constrains, the six reduction schemes have been shown to be unitary equivalent. Furthermore, the axial rotational ground state constant C(0) has been accurately determined. Copyright 1999 Academic Press.

Journal Article↗

Electrodes and multiple electrode systems for radio frequency ablation: a proposal for updated terminology.

OBJECTIVE: Research on technology for soft tissue radio frequency (RF) ablation is ever advancing. A recent proposal to standardize terminology of RF electrodes only deals with the most frequently used commercial electrodes. The aim of this study was to develop a logical, versatile, and unequivocal terminology to describe present and future RF electrodes and multiple electrode systems. MATERIALS AND METHODS: We have carried out a PubMed search for the period from January 1st 1990 to July 1st 2004 in seven languages and contacted the six major companies that produce commercial RF electrodes for use in the liver. In a first step, names have been defined for the five existing basic designs of single-shaft electrode. These names had to be unequivocal, descriptive of the electrode's main working principle and as short as possible. In a second step, these basic names have been used as building blocks to describe the single-shaft electrodes in combination designs. In a third step, using the same principles, a logical terminology has been developed for multiple electrode systems, defined as the combined use of more than one single-shaft RF electrode. RESULTS: Five basic electrode designs were identified and defined: plain, cooled, expandable, wet, and bipolar electrodes. Combination designs included cooled-wet, expandable-wet, bipolar-wet, bipolar-cooled, bipolar-expandable, and bipolar-cooled-wet electrodes. Multiple electrode systems could be characterized by describing several features: the number of electrodes that were used (dual, triple, etc.), the electric mode (monopolar or bipolar), the activation mode (consecutive, simultaneous or switching), the site of the inserted electrodes (monofocal or multifocal), and the type of single-shaft electrodes that were used. CONCLUSION: In this terminology, the naming ofthe basic electrode designs has been based on objective criteria. The short and unequivocal names of the basic designs can easily be combined to describe current and future combination electrodes. This terminology provides an exact and complete description of the versatile novel multiple electrode systems.

Catheter Ablation↗

Surgical radio-frequency epiduroscopy technique (R-ResAblator) and FBSS treatment: preliminary evaluations.

UNLABELLED: Failed back surgery syndrome represents a heterogeneous situation that suggests a fibrosis or neuroinflammatory genesis. The social cost related to this issue are enormous. Several surgical techniques have been applied to FBSS patients with controversial effectiveness. In 1998 we evaluated the efficiency and limits of epiduroscopy treatment; it proved to be effective in 75% of cases, but in 45% of cases it needed to be repeated after 12 months. Therefore we subjected 14 patients, who had previously experienced a short temporary benefit by using a traditional epiduroscopic approach, to a new epiduroscopy fibrolysis using a radio-frequency device named "R-Resablator Epiduroscopy". Clinical evaluation was performed before myeloscopy and after 1-3-6 months. After myeloscopy, 93% of patients reported a general improvement. Among the latter, pain was reduced by 90% in 8 patients, by 60-70% in 5, and by less than 30% in 1. CONCLUSION: It can be concluded that RF-Epiduroscopy offers greater therapeutic benefit than traditional epiduroscopy or other surgical techniques. Furthermore, RF-Epiduroscopy is more easily performed and repeated.

Back Pain↗

Centred radio-frequency hyperthermia in solid tumours.

After some notions on the mechanisms of action of radio-waves on solid tumours, the treatise illustrates the results achieved in the first 125 cases of malignant tumours treated with this method, its results are definitely encouraging, even in cases apparently with no hope. It also describes briefly the histologic modifications induced by this therapeutic method on neoplastic masses and discusses the criteria of the directions of thermotherapy, alone or combined, which is obviously the fifth weapon against tumours.

Adult↗

A method to measure the radio and chemosensitivity of human spheroids.

A method based on the spontaneous outgrowth of cells from spheroids was tested. Different outgrowth patterns were seen depending on the types of spheroids and on the radiation or drug doses. The method allowed dose-effect relations to be determined. Spheroid survival was defined as when the outgrowing monolayers contained at least thousand cells within five weeks. The method was used as an alternative to cloning of isolated single cells. The glioma and osteosarcoma spheroids could not be disintegrated to single cell suspensions since they resisted enzymatic and mechanical treatments for cell separation. Detection of differences in radio and chemosensitivity between different types of spheroids of human origin might be valuable for the understanding of the large variations in therapeutical response often seen between different types of tumors.

Animals↗

The neuroradiologist's contribution to stereotactic neuro-radio-surgery.

This publication is literally the same paper (having the same title and image material) which was previously presented at the International Symposium on Stereotactic Neuro-Radio-Surgery (Vienna, October 1992). Any actual updating of the topic has been avoided for reasons of historical accuracy and in order to document the atmosphere of that symposium which was then dominated by the unfolding of a new technology of intracranial lesion treatment. The neuroradiologist's contribution to this modality of treatment has to be the imaging and localizing such lesions accurately, as well as advising colleagues who plan radiosurgery and warning them about possible pitfalls. If there is no close cooperation between radiosurgeons and neuroradiologists, or if neuroradiological assistance is even disregarded, radiosurgical activities may fail.

Brain Diseases↗