Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Pulsed liquid jet dissector using holmium:YAG laser--a novel neurosurgical device for brain incision without impairing vessels.

BACKGROUND: Neurosurgery has long required a method for dissecting brain tissue without damaging principal vessels and adjacent tissue, so as to prevent neurological complications after operation. In this study we constructed a prototype of such a device and used it in an attempt to resect beagle brain cortex. METHOD: The prototype device consisted of an optical fibre, a Y adaptor, and a nozzle whose internal exit diameter was 100 microm. Cold physiological saline (4 degrees C) was supplied to it at a rate of 40 ml/h. Pulsed liquid jets were ejected from the nozzle by a pulsed Holmium:YAG) (Ho:YAG) laser at an irradiation energy of 300 mJ/pulse. The profile of the liquid jet was observed with a high-speed camera while changing the distance between the optical fibre end and nozzle exit (equivalent to the standoff distance). With this device (3 Hz operation), brain dissection of anaesthetized beagles was attempted while measuring the local temperature of the target. A histological study of the incised parts was also performed. FINDINGS: When the standoff distance was 24 mm, the liquid jet was emitted straight from the nozzle at a maximum initial velocity of 50 m/s. The brain parenchyma was cut with this device while preserving vessels larger than 200 microm in diameter and keeping the operative field clear. The local temperature rose to no more than 41 degrees C, below the functional heat damage threshold of brain tissue. Histological findings showed no signs of thermal tissue damage around the dissected margin. INTERPRETATION: The Ho:YAG laser-induced liquid jet dissector can be applied to neurosurgery after incorporating some minor improvements.

Animals↗

In vivo optical reflectance imaging of spreading depression waves in rat brain with and without focal cerebral ischemia.

Spreading depression (SD) waves occur in focal cerebral ischemia of the brain. Optical reflectance imaging at 550 +/- 10-nm wavelength using a charge-coupled device (CCD) camera, called optical intrinsic signal imaging (OISI) in the neuroscience community, provides high resolution imaging of SD waves based on changes in blood perfusion. We present optical images of SD waves in normal rat brain induced by a pinprick, and the spontaneous SD waves that follow middle cerebral artery occlusion (MCAO). The images of change in reflectance are calculated as A = (I-I(o))I(o), where I is pixel intensity as some timepoint and I(o) is the initial intensity just prior to an SD wave. Difference images B = [I(i)-I(i-1)]I(o), where I(i) is the image at time i and I(i-1) is the previous image at time i-1 (a 6.4-s interval), significantly sharpen the boundaries between leading and trailing edges of the SD wave. Maximum rate-of-change images C = max(B) display the maximum pixel value of B within the duration of a single SD wave, and provide an image that visualizes the entire penumbra. The penumbra appear bright due to a rapid drop in perfusion, while the normal brain and infarct area appear dark.

Animals↗

A new device for measuring density of jaw bones.

OBJECTIVES: The purpose of this project was to develop a lightweight, simple device to evaluate alveolar process bone density using normal intraoral and extraoral imaging procedures. METHODS: A simple lightweight device was constructed using barium sulfate as the major radiopaque component. The 5 x 32 x 12 mm(3) resin block has eight segments with known densities ranging from 1.304 (g/cm(3)) to 1.982 (g/cm(3)). The device was integrated into an XCP unit for standard intraoral radiographs and placed between the jaws for computer aided tomographic imaging. The relationship between the device segment densities and the optical densities of the exposed film was plotted. RESULTS: A linear inverse relationship was found between the device segment densities and optical densities when segment densities were between 1.304 (g/cm(3)) to 1.882 (g/cm(3)). However, the relationship was non-linear for segment densities above 1.882 (g/cm(3)). CONCLUSIONS: Normal human bone density is 1.85 (g/cm(3)), and this densitometer is useful for determination of material densities from 1.304 (g/cm(3)) to 1.882 (g/cm(3)). The device may be useful for precise bone density assessment.

Absorptiometry, Photon↗

Toward virtual biopsy through an all fiber optic ultrasonic miniaturized transducer: a proposal.

The present generation of devices based on opto-acoustic and acousto-optic conversion lets us foresee the possibility of realizing complete miniaturized transmitting-receiving transducers, able to generate and detect wideband ultrasounds by laser light. In the present paper, a miniaturized ultrasonic transducer entirely based on fiber optic technology is proposed. Such a device springs from the conjunction between our research, which has produced a highly efficient fiber optic opto-acoustic source, with the results obtained by other researchers concerning the realization of an ultrasonic receiver based on optical interferometry. Making use of the thermo-elastic effect for ultrasound generation, a source of ultrasound can be obtained by coupling a fiber optic to pulsed laser, if a film capable of absorbing laser light is placed onto fiber end. Starting from these remarks, we propose an efficient opto-acoustic source, able to generate pressure pulses with amplitude of the order of 10(4) Pa and bandwidth extending up to 40 MHz and beyond by using graphite materials as absorbing film. This solution makes use of a low-power pulsed laser as optical source possible. An ultrasonic receiving element was realized placing a Fabry-Perot cavity over the tip of a fiber optic. The cavity thickness modulation induced by ultrasonic beam is detected by an interferometer optical technique. We have realized a prototype of a receiving device that exhibits a sensitivity comparable with that of piezoelectric devices (10-100 nV/Pa) and an almost flat bandwidth extending up to 20 MHz or more. The extreme miniaturization of the resulting ultrasonic transducer, together with its wide ultrasonic frequency bandwidth, is the first step toward ultrasonic tissue biopsy. In this paper, before discussing the problem of constructing a complete ultrasonic transducer composed by a transmitter and receiver, the results carried out in these fields during the last decade are reviewed.

Biopsy↗

A microchip sensor for calcium determination.

A newly designed glass-PDMS microchip-based sensor for use in the determination of Ca(2+) ions has been developed, utilizing reflectance measurements from arsenazo III (1,8-dihydroxynaphthalene-3,6-disulfonic acid-2,7-bis[(azo-2)-phenyl arsenic acid]) immobilized on the surface of polymer beads. The beads, produced from cross-linked poly(p-chloromethylstyrene) (PCMS), were covalently modified with polyethylenimine (PEI) to which the Arsenazo III could be adsorbed. The maximum amount of Arsenazo III which could be immobilized onto the PEI-attached PCMS beads was found to be 373.71 mg g(-1) polymer at pH 1. Once fabricated, the beads were utilized at the detection point of the microfluidic sensor device with a fiber optic assembly for reflectance measurements. Samples were mobilized past the detection point in the sensor where they interact with the immobilized dye. The sensor could be regenerated and re-used by rinsing with HCl solution. The pH, voltage, linear range, and the effect of interfering ions were evaluated for Ca(2+) determination using this microchip sensor. At the optimum potential, 0.8 kV, and pH 9.0, the linear range of the microchip sensor was 3.57 x 10(-5) - 5.71 x 10(-4) M Ca(2+), with a limit of detection (LOD) of 2.68 x 10(-5) M. The microchip biosensor was then applied for clinical analysis of calcium ions in serum with good results.

Arsenazo III↗

Velocimetry microsensors driven by linearly polarized optical tweezers.

We report on a new type of single-point velocimetry microsensor that can be positioned in microfluidic devices by use of optical tweezers. The flag-shaped microsensor is readily made by a low-cost two-photon polymerization technique. At rest the linearly polarized optical tweezer traps the microsensor at the focal point, and the flag-plate gets aligned in the polarization direction. Under a fluid flow, the plate rotates to an equilibrium angle that is used to measure the fluid velocity with a micrometer-size spatial resolution. Experimental results are in good agreement with theoretical calculations of optical and hydrodynamic torques on such a flag-shaped microsensor.

Journal Article↗

Three-dimensional adaptive optics ultrahigh-resolution optical coherence tomography using a liquid crystal spatial light modulator.

A liquid crystal programmable phase modulator (PPM) is used as correcting device in an adaptive optics system for three-dimensional ultrahigh-resolution optical coherence tomography (UHR OCT). The feasibility of the PPM to correct high order aberrations even when using polychromatic light is studied, showing potential for future clinical use. Volumetric UHR OCT of the living retina, obtained with up 25,000A-scans/s and high resolution enables visualization of retinal features that might correspond to groups of terminal bars of photoreceptors at the external limiting membrane.

Humans↗

Effective spherical aberration compensation by use of a nematic liquid-crystal device.

The next generation of optical data storage system beyond DVDs will use blue laser light and an objective lens with a high numerical aperture of 0.85 to increase storage capacity. Such high numerical aperture systems have an inherent higher sensitivity to aberrations. In particular, the spherical aberration caused by cover layer thickness tolerances and--more obvious--by dual-layer disks with a typical separation of approximately 20 microm between the two layers must be compensated. We propose a novel transmissive nematic liquid-crystal device, which is capable of compensating spherical aberration that occurs during the operation of optical pickup systems.

Journal Article↗

Reproducibility of the optic nerve head topography with a new laser tomographic scanning device.

BACKGROUND: Laser scanning tomography has been shown to be an accurate and reliable method for the assessment of the three-dimensional optic disc topography. The authors investigate the reliability of morphometric measurements with the Heidelberg retina tomograph, a new instrument which was designed based on this technology, which simplifies handling and is much smaller than the laser tomographic scanner. METHODS: Three independent measurements of the optic disc were performed in 39 eyes of 39 patients which were equally divided into the following three groups: glaucoma, glaucoma suspects, and controls. RESULTS: The mean coefficient of variation for measurement in the glaucoma, glaucoma suspect, and control groups was 2.9%, 5.0%, and 3.4%, respectively, for cup area; 4.9%, 4.6%, and 4.6%, respectively, for cup volume; 5.2%, 3.8% and 3.3%, respectively, for mean cup depth; and 5.2%, 4.1%, and 4.0%, respectively, for maximal cup depth. The mean standard deviation for one pixel of the total image was 30 +/- 6 microns, 28 +/- 7 microns, and 22 +/- 6 microns for the three groups, respectively. CONCLUSION: The Heidelberg retina tomograph enables fast and reliable measurement of the optic disc topography and therefore may allow exact follow-up of patients.

Adult↗

Motor response detection using fiber optics during functional magnetic resonance imaging.

Data acquisition during functional magnetic resonance imaging and magnetoencephalography studies is easily disturbed by metallic and magnetic devices. Nevertheless, recording motor responses during many neuropsychological studies is essential. In this paper, we describe the design and construction of a nonmetallic, nonmagnetic motor response recording device that uses fiber optics to obtain interference-free data.

Brain↗

A simple device for respiratory gating for the MRI of laboratory animals.

Respiratory motion must be overcome if MRI of the abdomen, even at the lowest resolution, is to be performed satisfactorily. A simple and reliable respiratory gating device, based on the interruption of an infrared (IR) optical beam is described. This device has the advantage that gating is based on the position of the chest as opposed to its velocity, and that it can be used without degrading the radiofrequency isolation of a Faraday cage. Its use in animal MRI is illustrated by high resolution (200 microns) images of in vivo rat liver and kidney.

Abdomen↗

Optically switchable liquid crystal photonic structures.

Photo-optic materials offer the possibility of light controlled photonic devices, intelligent and environmentally adaptive optical materials. One strategy for creating these materials is the combination of structure formation through holographic photopolymerization and the variable optical properties of liquid crystals. Holographically patterned, polymer stabilized liquid crystals (HPSLCs) have proven to be useful optical materials. By incorporating photo-optic, azobenzene-derived liquid crystal blends into such material systems, we have generated practical photoresponsive optical materials.

Journal Article↗

Direct measurement of superluminal group velocity and signal velocity in an optical fiber.

We present an easy way of observing superluminal group velocities using a birefringent optical fiber and other standard devices. In the theoretical analysis, we show that the optical properties of the setup can be described using the notion of "weak value." The experiment shows that the group velocity can indeed exceed c in the fiber; and we report the first direct observation of the so-called "signal velocity," the speed at which information propagates and that cannot exceed c.

Journal Article↗

Micropatterned surfaces prepared using a liquid crystal projector-modified photopolymerization device and microfluidics.

A commercial liquid crystal device projector was modified for photopolymerization using its on-board intense light source and a precision optical control circuit. This device projects reduced images generated by a typical personal computer onto the stage where photopolymerization on a surface occurs. This all-in-one device does not require expensive photomasks and external light sources. However, light scattering and diffraction through glass substrates resulted in undesired reactions in areas corresponding to masked (black) domains in mask patterns, limiting pattern resolution. To overcome this shortcoming, two-step surface patterning was developed. First, three-dimensional microstructures of crosslinked silicone elastomer were fabricated with this device and adhered onto silanized glass substrate surfaces, forming microchannels in patterns on the glass support. Then, acrylamide monomer solution containing photoreactive initiator was flowed into these micromold channels and reacted in situ. The resultant polyacrylamide layer was highly hydrophilic and repelled protein adsorption. Cell seeding on these patterns in serum-supplemented culture medium produced cells selectively adhered to different patterns: cells attached and spread only on unpolymerized silanized glass surfaces, not on the photopolymerized acrylamide surfaces. This technique should prove useful for inexpensive, rapid prototyping of surface micropatterns from polymer materials.

Acrylic Resins↗