Replacement of the knee joint with the Walldius prosthesis using cement fixation.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
OBJECTIVE: To evaluate arthroscopic versus fluoroscopic reduction and percutaneous fixation of lateral tibial plateau fractures of AO/OTA Types 41.B1 to 41.B3. DESIGN: Prospective study. SETTING: University hospital. PATIENTS AND INTERVENTION: One hundred sixty-eight patients underwent operative treatment for a tibial plateau fracture from 1988 to 1995. Thirty-three of these patients had monocondylar fractures of the lateral plateau that were treated by percutaneous reduction and fixation techniques. In the first ten cases, arthroscopic control of reduction was used. The following twenty-three consecutive cases were treated by reduction and fixation solely under fluoroscopic control. The arthroscopy group was followed for a mean of fifty-two months and the fluoroscopy group for thirty-eight months. RESULTS: Nine of ten cases of the arthroscopy group had an excellent or good result in Rasmussen's knee score at follow-up. One patient with an unreduced anterolateral depression zone despite arthroscopic surgery required a total knee prosthesis after eighteen months. Sixteen cases in the fluoroscopy group met the follow-up criteria. Fifteen were graded good or excellent in Rasmussen's clinical score; sixteen were excellent or good in the radiological score. One patient claimed chronic medial joint line pain after a lateral split fracture and had arthroscopy revealing chondral degeneration on the medial side but had no pathological findings in the lateral compartment. No secondary meniscus or ligament surgery was performed in the follow-up period. CONCLUSIONS: Percutaneous treatment of fractures of the tibial plateau can be performed using arthroscopy as well as image intensification to control reduction of the joint surface. We were not able to demonstrate any significant benefit from arthroscopy compared with fluoroscopic reduction. Reduction under image intensification is technically easier in our practice, especially in serial fractures and multiply injured patients. We reserve arthroscopy for cases with significant ligament injuries and for children with fractures of the median eminence.
Biomaterial-associated infection of orthopaedic joint replacements is the second most common cause of implant failure. Yet, the microbiologic detection rate of infection is relatively low, probably because routine hospital cultures are made only of swabs or small pieces of excised tissue and not of the surfaces of potentially infected implants. Joint replacements from patients in whom infection was suspected, after clinical, radiologic, and biochemical examinations, were used in this study. The aim of the current study was to compare the detection rate of infection in total joint replacements based on cultures of the excised tissue and scrapings from the biomaterial surface. Joint prostheses were retrieved from 22 patients requiring orthopaedic revision surgery because of suspected infection of their prostheses. Routine hospital culturing of tissue only showed bacterial growth in nine patients (41%). However, after prolonged culturing, bacterial growth was observed in 14 patients (64%), whereas extensive culturing of scrapings from the biomaterial surface indicated bacterial growth in 19 of the 22 patients (86%). In addition, confocal laser scanning microscopy enabled observation of biofilm bacteria on the surfaces of the explanted prostheses. Diagnosis in orthopaedic revision surgery should consider using a microbial or microscopic analysis of the surface of an explanted prosthesis, where the biofilm mode of growth firmly anchors and protects the infecting organisms. Improved detection of infection by analysis of the implant surface is expected to yield ameliorated therapy and a reduced need for revision surgery.
Four patients with five severely traumatized lower legs but preserved feet were treated with fillet flaps from the foot to cover an elective, below knee amputation stump. The posterior tibial neurovascular bundle nourished and innervated this flap. While the posterior tibial artery and vein may be cut and re-anastomosed to prevent kinking and occlusion, the posterior tibial nerve should always be kept in continuity to maintain the quality of sensation to this flap. Four flaps survived and one necrosed secondary to venous insufficiency. Due to its innervation and the unique qualities of heel skin, the flap is very durable and has endweight-bearing capabilities. This has permitted the fitting of an endweight-bearing, total contact, fully extended, below knee prosthesis that appears to offer significant improvement in ease of use and normality of gait pattern over standard patellar tendon-bearing prostheses.
The short- and long-term successes of tibial cementless implants depend on the initial fixation stability often provided by posts and screws. In this work, a metallic plate was fixed to a polyurethane block with either two bone screws, two smooth-surfaced posts, or two novel smooth-surfaced posts with adjustable inclinations. For this last case, inclinations of 0, 1.5, and 3 deg were considered following insertion. A load of 1031 N was eccentrically applied on the plate at an angle of approximately 14 deg, which resulted in a 1000 N axial compressive force and a 250 N shear force. The response was measured under static and repetitive loading up to 4000 cycles at 1 Hz. The measured results demonstrate subsidence under load, lift-off on the unloaded side, and horizontal translation of the plate specially at the loaded side. Fatigue loading increased the displacements, primarily during the first 100 cycles. Comparison of various fixation systems indicated that the plate with screw fixation was the stiffest with the least subsidence and liftoff. The increase in post inclination from 0 to 3 deg stiffened the plate by diminishing the liftoff. All fixation systems demonstrated deterioration under repetitive loads. In general, the finite element predictions of the experimental fixation systems were in agreement with measurements. The finite element analyses showed that porous coated posts (modeled with nonlinear interface friction with and without coupling) generated slightly less resistance to liftoff than smooth-surfaced posts. In the presence of porous coated posts, Coulomb friction greatly overestimated the rigidity by reducing the liftoff and subsidence to levels even smaller than those predicted for the design with screw fixation. The sequence of combined load application also influenced the predicted response. Finally, the finite element model incorporating measured interface friction and pull-out responses can be used for the analysis of cementless total joint replacement systems during the post-operation period.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: To investigate the source of infections associated with orthopaedic prostheses. DESIGN: Analysis of four infections of prosthetic joints with case records; minimum inhibitory and minimum bactericidal concentrations and sodium dodecylsulphate polyacrylamide gel electrophoresis of the cell wall polypeptides of the Streptococcus sanguis isolates from the mouth and infected prostheses; examination of the patients' mouths for periodontal disease and caries. SUBJECTS: Four adults (three men) aged 58-83. RESULTS: For each patient the strain of S sanguis isolated from the mouth was indistinguishable from that isolated from the prosthesis. All patients had severe periodontal disease and caries. CONCLUSIONS: The mouth was probably the source of bacterial infection in the prosthetic joints of these patients; the route of infection was possibly haematogenous. Incipient oral infection should be treated before joint replacement, and oral health should be maintained indefinitely.
Explore the source record for details and available documents.
The authors discuss and illustrate the various complications of total joint prostheses. Criteria for the evaluation of radiographs of total joint prostheses are presented.
BACKGROUND AND OBJECTIVE: Correct utilization of source isolation (SI) in hospitals is important to take advantage of hospital resources. The objective of this work was to evaluate the utilization of SI considering the appropriateness of isolation length-stay. PATIENTS AND METHOD: During a period of 19 months a prospective observational study was carried out among non-critical inpatients who underwent SI in a university hospital. The information was obtained from Admission Unit data, daily ward rounds and review of case history records. RESULTS: A total of 239 SIs were identified, summarizing 2,589 days in isolation (median: 8 days, range: 1-56 days). These data supposed a cumulative incidence of 6.74 isolations by 1,000 admissions, and an incidence density of 1.08 isolations by 1,000 inpatient-day. 36.8% of SIs were considered incorrectly used, meaning a total of 703 inappropriate stays in isolation (27.1% of all stays carried out in SI). Surgical wound infections prompted inappropriate isolations with a greater frequency (45.2%), mainly after hip and knee prosthesis implantation interventions (42.9% and 17.9%, respectively). CONCLUSIONS: It is necessary to develop quality criteria and indicators in order to implement quality improvement actions to optimize SI length-stay management.
We investigated the source of intravascular fat in systemic organs (brain, heart, and kidney) after massive pulmonary fat embolism during cemented arthroplasty. We used a bilateral cemented arthroplasty (BCA) in anesthetized mongrel dogs that simulates a cemented total-hip replacement procedure. We hypothesized that deformable fat globules could pass through the lung vasculature under high pulmonary artery pressure (Ppa). Using quantitative morphometry, we showed that the size of pulmonary vessel occluded by fat decreased from 12.8 +/- 15.2 microns 1 min after BCA to 4.9 +/- 5.1 microns at 120 min after BCA (p < 0.01). Ultrastructural studies demonstrated no evidence of acute inflammation around fat-occluded pulmonary vessels 3 h after BCA. Intravascular fat was found in all brain, heart, and kidney specimens examined 3 h after BCA (n = 6). No anesthetized animal in the "sham" (no BCA) group (n = 3) had intravascular fat at the same time period. Radiolabeled microspheres (15 microns diameter) did not reach the systemic circulation (< 1% nonentrapment) under the high Ppa after BCA. No patent foramen ovale was found in any dog at postmortem examination. We conclude that fat globules can traverse the pulmonary circulation within 3 h of orthopedic surgery. The difference between solid microspheres and fat in transpulmonary passage suggests that the composition, perhaps the deformability, of embolic material influences the lung's filtering capacity.
This study was conducted in a nonteaching community hospital to characterize the use of prophylactic antibiotics in patients undergoing total joint replacements by orthopedic surgeons in private practice. Of the 101 patients studied, 43 were started on antibiotics too early, 32 were left on the drugs for too long a period, and 33 received subsequent oral antibiotics without identifiable reason. Seventy-nine (78.2 percent) received 8 g/d of a first- or second-generation cephalosporin for prophylaxis. None of the patients received cefazolin 1 g q8h.
An epidemiological survey of the use of antimicrobial prophylaxis in Italian hospitals was carried out under the auspices of the Journal of Chemotherapy. Out of 500 Italian orthopedic centers queried, 225 agreed to participate in this study. A total of 136,321 surgical procedures were reported in the 166 centers reporting complete answers on type of surgery. They comprised hip and knee prosthesis (13.9%), spine surgery (4%), hip endoprosthesis (5.2%), osteosynthesis (26.9%), arthroscopy (24.4%), and others (25.5%). Perioperative antimicrobial prophylaxis was used in 75% of operations (ranging from 57.1% to 99.4% in arthroscopy and joint prosthesis, respectively). Short term (<24 h) antimicrobial prophylaxis was performed in 38.4% of the 206 centers answering this question correctly. 61.1% of centers employed single agent prophylaxis and 70.8% of these prescriptions were betalactam antibiotics. Bacteriological analysis revealed gram-positive isolates in 73.3% of cases. Methicillin resistance was present in 45% of 915 tested strains. Out of 4221 patients with high risk of infectious complications (joint prosthesis surgery) given antimicrobial prophylaxis in 46 centers, the percentage of surgical wound infections was overall 2.1%, while that of non-surgical wound infections was 3.6%. The total infection rate was decreased by about half in association with long-term (>24 h) as compared to short-term (<24 h) antibiotic treatment (3.7% vs 7.6%, respectively), and with use of antibiotic drug combinations vs single antibiotic drugs (3.9 vs 6.6%, respectively). The incidence of surgical-site infection was not decreased by extending the chemoprophylaxis for more than the first 24 h after surgery, while it was reduced from 2.5 to 1.4% by use of combination antibiotic therapy.
This article reviews the need for standards for orthopaedic implants and illustrates the differences in approach of the European Standard Organization compared to National and International Standards. The areas where new work is being undertaken are outlined.
Explore the source record for details and available documents.
Explore the source record for details and available documents.