Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

An ultrafiltration catheter for monitoring of venous lactate and glucose around myocardial ischemia.

Early detection of myocardial ischemia is of major importance in critical-care medicine. Changes of lactate or glucose levels in the cardial venous efflux may be useful parameters. We succeeded in integrating an ultrafiltration membrane in a cardiac catheter for continuous sampling. The ultrafiltrate was analyzed outside the body, resulting in a lag-time of about 24 min. Biosensors in a flow-injection analysis system were used for minute by minute sample analyses. The coronary sinus of pigs was catheterized to monitor the effects of 5, 15 or 45 min ischemia by coronary artery obstruction or myocardial stress by dobutamine infusion. A total of 27 h was monitored. The intravascular response time was 1.33+/-0.61 min (10-90%). Linear regression in vivo of blood and ultrafiltrate samples was 0.977 for lactate and 0.994 for glucose. Lactate levels rose 0.38+/-0.10 mM above baseline within 5 min after ischemia. Reperfusion was clearly marked by a promptly peaking lactate release (maximum 9.27 mM). Myocardial stress by dobutamine increased glucose but not lactate levels. Once, a wall effect was noted at the catheter tip. In vivo semi-continuous myocardial monitoring of absolute lactate and glucose concentrations was thus achieved by an ultrafiltration catheter. Ischemia and reperfusion can be detected very early by a lactate level rise. Further, development of the ultrafiltration catheter will be focused on the diagnostic potential of lactate monitoring for patients.

Animals↗

Integrated capillary fluorescence DNA biosensor.

Covalent attachment of dsDNA molecules inside a glass capillary without the need for hybridization is described. It is shown that the glass capillary has a surface density of 2.5 x 10(13) molecules/cm(2) with specific binding capacity of 62.5%. The resulting substrate was used to develop a biosensor for determining fluorescent organic analytes and metal binding with DNA. The biosensor combines highly specific immobilization chemistry with a capillary-geometry flow cell arrangement. The results show that fluorescent dyes are retained in the dsDNA-modified surface and that exposure to concentrations of nickel and lead ions resulted in a recoverable, highly reproducible diminishment of the fluorescence intensity.

Adsorption↗

An oxygen-rich fill-and-flow channel biosensor.

An oxygen-rich fill-and-flow channel biosensor has been developed for the measurement of glucose in wine. Glucose oxidase (GOD), immobilised in carbon paste (CP), was located in a well adjacent to a downstream detector electrode. When the analyte solution flows, hydrogen peroxide produced in the enzyme reaction is swept down to the detector electrode. Mineral oil and Kel-F oil (poly(chlorotrifluorethylene)) were used to prepare an enzyme layer of GOD within a CP. The hydrophobicity of the CP confined the reaction between the enzyme and its substrate to the surface of the enzyme layer. The oxidation current of hydrogen peroxide was sensitive to the enzyme loading but insensitive to mass transport variations such as flow rate. This response was, therefore, limited by the kinetics of the reaction between the enzyme and the substrate. For Kel-F oil, which can support a high concentration of dissolved oxygen, good reproducibility and greater dynamic range was obtained and the response did not decrease after degassing for 40 min with argon. Analysis of wine samples showed good agreement with the values obtained by spectrophotometric enzyme assay.

Biosensing Techniques↗

Biosensor for rapid phosphate monitoring in a sequencing batch reactor (SBR) system.

A thick-film phosphate biosensor based on hydrogel immobilized pyruvate oxidase (POD) has been developed for rapid phosphate process control monitoring in an experimental sequencing batch reactor (SBR) system. We have employed a phosphate biosensor in an off-line monitoring of phosphate concentrations in a bench scale SBR. Measurements with biosensor show a good correlation (r2=0.98) with those of commercial colorimetric phosphate testing kits. The signal response time was 1 min with a detection limit of 5 microM. The biosensor method showed a good operational stability, needed less experimental procedures and a small sample size (approximately 20 microl). This allows its practical application for rapid phosphate measurements to obtain real time process data in a SBR system.

Bioreactors↗

Detection of heavy metal ions using protein-functionalized microcantilever sensors.

Microcantilevers functionalized with metal-binding protein, AgNt84-6, are demonstrated to be sensors for the detection of heavy metal ions like Hg(2+) and Zn(2+). AgNt84-6, a protein that has the ability to bind multiple atoms of Ni(2+), Zn(2+), Co(2+), Cu(2+), Cd(2+) and Hg(2+) was attached to the gold-coated side of silicon nitride cantilevers via linker groups. Upon exposure to 0.1 mM HgCl(2) and 0.1 mM ZnCl(2) solutions, the microcantilevers underwent bending corresponding to an expanding gold side. Exposure to a 0.1 mM solution of MnCl(2) solution did not result in a similar bending indicating a weak or no interaction of Mn(2+) ions with the AgNt84-6 protein. The microcantilever bending data were consistent with data from electrophoresis carried out on SDS-PAGE gels containing metal ions that showed protein interaction with Zn(2+) ions but not with Mn(2+) ions. Thus, we demonstrate that microcantilever bending can be used to discriminate between metal ions that bind and do not bind to AgNt84-6 protein in real time.

Biosensing Techniques↗

Characterization of immobilization methods for African swine fever virus protein and antibodies with a piezoelectric immunosensor.

A direct piezoelectric flow injection analysis immunoassay for the detection of African Swine Fever virus and antibodies is presented. The peptide-specific monoclonal antibody 18BG3 and the virus protein 73 were used for detection with a quartz crystal microbalance. Accumulation of the analyte on the surface of this mass-sensitive biosensor resulted in a shift of the resonant frequency. Highly selective receptor layers were applied on the sensing electrode of the quartz crystal for detection of the complementary analyte. Different immobilization methods proved to be appropriate for coating of the monoclonal antibody 18BG3. A quartz crystal covalently coated with the antibody 18BG3 detected virus protein VP73 samples more than 20 times and was stable for more than 30 days. The coating of virus protein was performed by physisorption. A sensor with a virus protein receptor layer detected antibody 18BG3 samples 10 times within one day. The sensor device was able to perform one measurement cycle including blocking and regeneration within 30 min. With the help of a suitable carrier liquid, measurements with serum samples were performed. The calibration curves for measurements in buffer and in serum could be determined and the detection limits for virus protein detection were 0.31 and 1 microgram/ml, and for antibody detection 0.1 and 0.2 microgram/ml, respectively.

African Swine Fever Virus↗

Quartz crystal microbalance (QCM) as a device for the screening of phage libraries.

An immunosensing system based on a quartz crystal microbalance (QCM) is presented for the selection of both antigen specific recombinant antibodies and antigen specific human pancreatic secretory trypsin inhibitor (hPSTI) mutants isolated from large phage libraries. The QCM was integrated into a flow injection analysis system for the straightforward analysis of large sample numbers. Measurements were performed using a biotinylated antigen immobilized by streptavidin onto the gold surface of the quartz crystal and phages displaying recombinant antibodies or hPSTI mutants. The results obtained by the QCM were in accordance to those of a well established enzyme linked immunosorbent assay (ELISA). Therefore, the QCM is well suited for the detection of single high affinity clones isolated from large phage display libraries.

Bacteriophages↗

Optical flow-cell multichannel immunosensor for the detection of biological warfare agents.

An automated optical flow cell multichannel immunosensor for the detection and identification of toxins, viruses and bacterial particles is presented. A solid phase ELISA, based on a peroxidase label for signal generation and on fused silica capillaries as a support for immobilized antibodies, has been employed for analyte detection and identification. The sensing and signal transducing component of the sensor consists of a light-emitting diode and a photodetector. The device is fitted with three channels allowing the simultaneous detection of three agents. An integrated flow injection analysis system ensures automation of the assay cycles. Data on the detection of the bacterial toxin staphylococcal enterotoxin B (SEB), the bacteriophage M13 as a viral agent, and Escherichia coli as a bacterial agent are presented.

Bacteriophage M13↗

Effect of controlling lactate concentration and periodic change in DO concentration on fermentation characteristics of a mixed culture of Lactobacillus delbrueckii and Ralstonia eutropha for PHB production.

A mixed culture system was considered in the present research where sugars such as glucose were converted to lactate by Lactobacillus delbrueckii and the lactate was converted to poly beta-hydroxybutyrate (PHB) by Ralstonia eutropha in one fermentor. Based on the experimental studies on the effect of lactate concentration on the cell growth of both microorganisms, the lactate concentration was controlled at less than 5 g/l using an on-line enzymatic lactate and glucose sensors with the FIA (flow injection analysis) system, and by manipulating the glucose feeding rate. Since L. delbrueckii prefers anaerobic conditions while R. eutropha prefers aerobic conditions, we studied the effect of DO concentration on fermentation characteristics of each microorganism. For the mixed culture, we considered the control scheme of a two inputs and three outputs multivariable system. It was experimentally shown that the periodic fermentation resulted in superior PHB yield with relatively high productivity as compared with the cases where DO concentration was controlled to be constant either at less than 1 ppm or 3 ppm.

Journal Article↗

Gradient liquid chromatography of leucine-enkephalin peptide and its metabolites with electrochemical detection using highly boron-doped diamond electrode.

Boron-doped diamond thin film (BDD) electrodes have been used to study the oxidation reactions and to detect leucine-enkephalinamide (LEA) and its metabolites, tyrosine (T), tyrosyl-alanine (TA), tyrosyl-alanine-glycine (TAG) and leucine-enkephalin (LE) using cyclic voltammetry (CV), flow-injection analysis (FIA), and gradient liquid chromatography (LC) with amperometric detection. At diamond electrodes, well-defined and highly reproducible cyclic voltammograms were obtained with signal-to-background (S/B) ratios 5-10 times higher than those observed for glassy carbon (GC) electrodes. The analytical peaks of LC for LEA and its metabolites were well resolved. No deactivation of BDD electrodes was found after several experiments with standard as well as plasma samples, indicating high stability of the electrode. Calibration curves were linear over a wide range from 0.06 to 30 microM with regression coefficients of 0.999 for all compounds. The limits of detection obtained based on a signal-to-noise ratio of 3:1 were 3, 2.2, 2.7, 20 and 11 nM for T, TA, TAG, LE and LEA, respectively. These values were at least one order lower than those obtained at GC electrodes, which has given limits of detection of 22.88, 20.64, 89.57, 116.04 and 75.67 for T, TA, TAG, LE and LEA, respectively. Application of this method to real samples was demonstrated and validated using rabbit serum samples. This work shows the promising use of conducting diamond as an amperometric detector in gradient LC, especially for the analysis of enkephalinamide and its metabolites.

Boron↗

Iridium-based electrocatalytic systems for the determination of insulin.

Two electrochemical catalytic systems for the determination of insulin were developed. The homogeneous system was based on the oxidation of insulin by chloro complexes of iridium(IV). Kinetic studies revealed that the aquation of iridium complexes activated them toward the oxidation of insulin in acidic solutions; e.g., the rate constant was equal to 25, 900, and 8,400 L mol(-1) s(-1) for the oxidation of insulin by the IrCl62-, Ir(H2O)CI5-, and Ir(H2O)2Cl4 complexes, respectively. The inertness of the iridium complexes argued for the outer-sphere mechanism of the homogeneous oxidation reaction. Electroplating of aquated iridium complexes on the glassy carbon electrode resulted in the formation of the iridium oxide (IrOx) surface film, which was used in the heterogeneous detection system for insulin. The catalytic activity of the IrOx film toward insulin oxidation was ascribed to a combination of electron-transfer mediation and oxygen transfer which was related to the acid/base chemistry of the film. The IrOx film electrode was used as an amperometric detector for flow injection analysis of insulin in pH 7.40 phosphate buffer. Linear least-squares calibration curves over the range 0.05-0.50 microM (five points) had slopes of 35.2 +/- 0.4 nA microM(-1) and correlation coefficients of 0.999. The detection limit for insulin was 20 nM using the criterion of a signal of 3 times the peak-to-peak noise. The advantageous properties of the detector based on the IrOx film are its inherent stability at physiological pH, high catalytic activity toward insulin oxidation, and simplicity of preparation.

Algorithms↗

Ferricyanide reduction by Escherichia coli: kinetics, mechanism, and application to the optimization of recombinant fermentations.

Ferricyanide reduction was studied by flow injection analysis (FIA) and chronoamperometry (CA) using two host strains and one recombinant strain of E. coli. Samples taken from batch cultures of E. coli JM105 and HB101 showed maximal specific ferricyanide reduction rates in the late exponential phase of growth, with values (micromol/min x g) of 24 (FIA) and 17 (CA) for JM105, and 36 (FIA) for HB101, when shake-flask cultures were sampled, and 70 for HB101, when a chemostat was used to control pH and dissolved oxygen concentration throughout the cultivation. Remarkably higher ferricyanide reduction rates were obtained with HB101 cells cultivated continuously at very slow growth rate, when chilled, resuspended cell samples were incubated for 5 min in solutions containing 10 mM succinate or formate. These compounds are substrates for primary, membrane-bound dehydrogenases that transfer electrons via ubiquinone to the cytochrome oxidase complexes. Apparent Michaelis-Menten kinetics were observed with respect to ferricyanide concentration when 10 mM succinate was included in the assay buffer; apparent Km values of 10.1+/-0.6 mM and 14.4+/-1.2 mM ferricyanide were obtained for exponential- and stationary-phase E. coli JM105, respectively. Cyanide inhibition studies show that ferricyanide is reduced mainly by cytochrome o oxidase in exponentially growing cells. The large difference in ferricyanide reduction rates observed in the absence and presence of succinate and formate were used to signal stationary-phase entry 5 h after induction of recombinant human Cu/Zn superoxide dismutase expression in a batch fermentation of E. coli HMS174(DE3)(pET3ahSOD). This new method can be used as an adjunct to the quantitation of medium components for the optimization of recombinant fermentations.

Escherichia coli↗

Detection of native amino acids and peptides utilizing sinusoidal voltammetry.

Native amino acids and peptides were detected at a copper microelectrode using sinusoidal voltammetry (SV). Traditionally, these molecules can only be measured after derivatization with either a fluorescent or electroactive tag. In this work, an electrocatalytic oxidation reaction at copper is used to detect underivatized peptides and amino acids. The oxidation reaction is somewhat independent of peptide structure (i.e., it is not limited to the detection of aromatic amino acids) and is therefore able to produce nanomolar detection limits for all amino acids and peptides tested. A scanning technique, sinusoidal voltammetry, is used to provide the sensitivity of constant-potential techniques but also provide selectivity gained through utilization of the frequency domain. The frequency spectrum due to the oxidation of each molecule has a unique "fingerprint" response resulting from the kinetics of oxidation at the electrode surface. Through examination of the frequency spectra, even structurally similar molecules can be easily distinguished from one another. Flow injection analysis is used to demonstrate the sensitive and selective detection of a variety of amino acids and peptides. This technique can also be easily coupled to a separation step, i.e., high-performance liquid chromatography or capillary electrophoresis without electrode fouling from the adsorption of the analytes.

Amino Acids↗

Reduction of mass bias and matrix effects in inductively coupled plasma mass spectrometry with a supplemental electron source in a negative extraction lens

Electrons from a heated tungsten filament are created inside the extraction lens and driven out toward the skimmer. These electrons move through the ion path and reduce space charge effects between positive ions in the beam. The ion transmission efficiency is improved by factors of two (for Pb+) to 27 (for Li+). The greater sensitivity improvement for low-mass ions leads to a substantial reduction in mass bias. With the additional electrons, MO+/M+ and M2+/M+ abundance ratios increase but can be minimized with a small reduction in aerosol gas flow rate. No new background ions are observed with this technique. Matrix effects can be significantly diminished when the electron source is operated under the high electron current mode. The mass dependence of matrix-induced suppression of analyte signals is essentially eliminated. Using flow injection analysis to minimize solid deposition, the technique can tolerate Na matrix up to 10000 ppm (1%) with only approximately 15% loss of analyte sensitivity.

Journal Article↗

Plant tissue-based chemiluminescence flow biosensor for glycolic acid.

A novel plant tissue-based chemiluminescence (CL) biosensor for glycolic acid combined with flow injection analysis is proposed in this paper. The spinach tissue acts as the molecular recognition element. Glycolic acid is oxidized by oxygen under the catalysis of glycolate oxidase in the tissue column to produce hydrogen peroxide, which can react with luminol in the presence of peroxidase of spinach tissue to generate a CL signal. The CL emission intensity was linear with glycolic acid concentration in the range of 4 x 10(-3)-4 x 10(-6) mol/L and the detection limit was 1.3 x 10(-6) mol/L. The biosensor was stable for about 3 weeks. A complete analysis, including sampling and washing, could be performed in 1.5 min with a relative standard deviation of 1.7%.

Biosensing Techniques↗

Fractured carbon fiber-based biosensor for glucose.

A microsensor for glucose was constructed using DuPont E120 fibers, which exhibit extensive fracturing upon severe anodic pretreatment. The fracturing is accompanied by an increase in the electrochemical surface area of several orders of magnitude, which is exploited here in the design of a microsensor. Following fracture, the fibers were platinized to enhance their ability to detect enzymatically produced hydrogen peroxide, and glucose oxidase was immobilized at the surface of the fiber in polypyrrole. When operated amperometrically in flow injection analysis, the treated electrodes showed a linear response to injected glucose concentration up to 10 mM, with an observed Km' near 20 mM. The sensors were found to be stable for up to 2 months when stored dry at 4 degrees C.

Biosensing Techniques↗

Subsecond adsorption and desorption of dopamine at carbon-fiber microelectrodes.

High-repetition fast-scan cyclic voltammetry and chronoamperometry were used to quantify and characterize the kinetics of dopamine and dopamine-o-quinone adsorption and desorption at carbon-fiber microelectrodes. A flow injection analysis system was used for the precise introduction and removal of a bolus of electroactive substance on a sub-second time scale to the disk-shaped surface of a microelectrode that was fabricated from a single carbon fiber (Thornel type T650 or P55). Pretreatment of the electrode surfaces consisted of soaking them in purified isopropyl alcohol for a minimum of 10 min, which resulted in S/N increasing by 200-400% for dopamine above that for those that were soaked in reagent grade solvent. Because of adsorption, high scan rates (2,000 V/s) are shown to exhibit equivalent S/N ratios as compared to slower, more traditional scan rates. In addition, the steady-state response to a concentration bolus is shown to occur more rapidly when cyclic voltammetric scans are repeated at short intervals (4 ms). The new methodologies allow for more accurate determinations of the kinetics of neurotransmitter release events (10-500 ms) in biological systems. Brain slice and in vivo experiments using T650 cylinder microelectrodes show that voltammetrically measured uptake kinetics in the caudate are faster using 2,000 V/s and 240 Hz measurements, as compared to 300 V/s and 10 Hz.

Adsorption↗

Electroosmotic flow in composite microchannels and implications in microcapillary electrophoresis systems.

The electroosmotic flow in laminated excimer laser-ablated microchannels has been studied as a function of the depth of the rectangular channels, and particular emphasis has been given to the difference in the zeta-potentials between the lamination layer and the ablated substrate. Experimental electroosmotic flow follows the tendency predicted by a recently published model. The zeta-potentials of lamination and ablated surfaces were determined for poly(ethylene terephthalate) and poly(carbonate) substrates by fitting the experimental data with a numerical implementation of this model. In the experimentally investigated range of channel cross sections, a linear fit to the data gives a good approximation of the zeta-potentials for both materials. Moreover, a flow injection analysis of fluorescein dye has been performed to show the severe loss in numbers of theoretical plates, caused by Taylor dispersion, when such microchannels, dedicated to microcapillary electrophoresis, are used.

Journal Article↗