Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fixatives”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Fixation strengths of patellar tendon-bone grafts.

Secure fixation of bone-patellar tendon-bone grafts is essential to allow early joint mobilization after anterior cruciate ligament (ACL) reconstruction surgery. This study was designed to evaluate four fixation methods of patellar tendon-bone grafts in cadaveric knees. Fifty-one fresh cadaveric patellar tendon-bone specimens were anchored in tibial or femoral metaphyseal bone tunnels. Group I grafts were fixed with Kurosaka interference screws. In Group II the grafts were initially fixed as in Group I, but the screws were then removed, the bone plugs repositioned, and the grafts resecured with screws. In Group III the grafts were anchored with three no. 2 nonabsorbable sutures tied over a screw and washer, whereas in Group IV no. 5 nonabsorbable sutures were used. Each bone specimen was mounted in the biomechanical testing machine, and a vertical tensile load was applied at a strain rate of 51 cm/min until failure of fixation, bone plug fracture, or tendon disruption occurred. The mean force to failure in Groups I, II, III, and IV were 435.0 N, 458.2 N, 454.2 N, and 415.8 N, respectively. There was no significant difference in the force to failure among the four methods of fixation. However, the modes of failure were diverse. In three specimens the Kurosaka screws diverged from the plugs and failed to achieve fixation. These specimens were excluded and will be discussed separately. Although technique-related difficulties may arise, interference screw fixation of patellar tendon-bone grafts affords strong graft fixation--often stronger than the graft itself. Secondary screw fixation appears to be equal in strength to primary screw fixation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone.

It has recently been shown that graft fixation close to the ACL insertion site is optimal in order to increase anterior knee stability. Hamstring tendon fixation using interference screws offers this possibility and a round threaded titanium interference screw has been previously developed. The use of a round threaded biodegradable interference screw may be equivalent. In addition, to increase initial fixation strength, graft harvest with a distally attached bone plug may be advantageous, but biomechanical data do not exist. This study compares the initial pullout force, stiffness of fixation, and failure modes of three strand semitendinosus grafts in 36 proximal calf tibiae using either biodegradable poly-(D,L-lactide) (Sysorb; Sulzer Orthopaedics Ltd, Münsingen, Switzerland) or round threaded titanium (RCI; Smith & Nephew DonJoy, Carlsbad, CA) interference screws, harvested either without (biodegradable: group I, titanium III) or with (biodegradable: group II, titanium: group IV) attached tibial bone plugs. Maximum pullout force in group I (507 +/- 93 N) was significantly higher than in group III (419 +/- 77 N). Pullout force of bone plug fixation was significantly higher than that of direct tendon fixation (717 +/- 90 N in group II and 602 +/- 117 N in group IV). Pullout force of biodegradable fixation was significantly higher in both settings. These results indicate that initial pullout force of hamstring-tendon graft interference screw fixation can be increased by using a biodegradable interference screw. In addition, initial pullout force of hamstring-tendon graft fixation with an interference screw can be greatly increased by harvesting the graft with its distally attached tibial bone plug.

Absorption↗

The stability of double jaw surgery: a comparison of rigid versus wire fixation.

The subjects of this study were 35 patients who underwent simultaneous surgery for superior repositioning of the maxilla and advancement of the mandible. They were studied cephalometrically for a comparison of the postsurgical stability of two commonly used fixation techniques: (1) rigid fixation with bone plates and (2) skeletal-wire fixation. One surgeon performed the operations on all 35 patients, and both groups were studied for an average of 15 months after surgery. Results showed that, although the maxilla remained relatively stable after surgery with both fixation techniques, rigid fixation tended to improve stability, primarily by eliminating relapse in excess of 2 mm. Mandibular stability was much greater with rigid fixation: the amount of relapse of the horizontal projection of B point with this method was 6%, while in the skeletal-wire sample it was 26%. Increased rotational stability between the proximal and distal segments of the mandible appeared to be a major factor in the improved overall stability of the rigid-fixation sample. The amount of mandibular relapse was found to be correlated to the amount of advancement in the wire-fixation sample, but not in the rigid-fixation sample.

Adult↗

Comparison of allograft to autograft in multilevel anterior cervical discectomy and fusion with rigid plate fixation.

BACKGROUND CONTEXT: A relatively high pseudarthrosis rate is associated with multilevel anterior cervical discectomy and fusion (ACDF). Anterior plate fixation increases fusion rate in multilevel ACDF. A debate still exists between the effectiveness of allograft versus autograft in plated multilevel ACDF. PURPOSE: To determine the efficacy of allograft versus autograft in fusion rate and clinical outcome in patients undergoing two- and three-level ACDFs with rigid anterior plate fixation. STUDY DESIGN: A retrospective radiographic and clinical review to assess fusion, risk factors and clinical outcome of 80 consecutive patients who underwent ACDF with rigid anterior plate fixation involving two and three levels with either allograft or autograft. PATIENT SAMPLE: There were 45 patients (56%) who had autogenous iliac crest tricortical grafts and 35 patients (44%) who received tricortical allograft with an average age of 49 years who were treated by multilevel ACDF with rigid anterior plate fixation at a single institution. Thirty-three Peak polyaxial (Depuy-Acromed, Rayham, MA), 26 Orion (Sofamor-Danek, Memphis, TN), 16 Atlantis (Sofamor-Danek, Memphis, TN) and 5 Synthes (Paoli, PA) anterior cervical plating systems were used. All patients underwent ACDF (61 two-level, 19 three-level) by a Smith Robinson technique. All patients had burring of the end plates, 2-mm distraction of the motion segment and graft countersunk 2 mm from the anterior vertebral border. Anterior cervical plate with unicortical screw purchase was used in all cases. Segmental screw fixation was performed in 46 patients. Soft collars were worn postoperatively for 3 to 4 weeks. OUTCOME MEASURES: Follow-up lateral neutral, flexion and extension radiographs were used to assess fusion. The radiographs were reviewed by an independent blinded observer in assessing fusion grades between autograft versus allograft. Clinical outcomes were rated excellent, good, fair and poor based on Odom's criteria. METHODS: Fusion rate and postoperative clinical outcome were assessed in 80 patients who underwent two- or three-level ACDF with rigid anterior plate fixation. Additional risk factors were also analyzed. RESULTS: Radiographic fusion was assessed in all patients (mean, 16 months). Seventy-eight patients (97.5%) achieved solid arthrodesis. Pseudarthrosis occurred in two patients who had allograft for two-level and three-level fusions. Nonsegmental screws were used in the two-level nonunion case. Postoperative dysphagia developed in one two-level nonunion patient, and revision surgery was performed in the other nonunion three-level patient. Twenty-three patients were smokers, and 26 patients had work-related injuries. Clinical outcome (mean, 20 months) was excellent in 23, good in 48 and fair in 9 patients. No statistical significance was noted between demographics, history of tobacco use, graft-type, end plate preparation technique, intermediate segmental screws, plate-type, clinical outcome of fused and nonfused patients and presence of work-related injuries (p>.05). CONCLUSIONS: A high fusion rate of 97.5% was obtained for multilevel ACDF with rigid plating with either autograft or allograft. In this study, nonunion occurred in patients with allograft but this difference was not statistically significant. Fusion was obtained in 97.8% of patients with segmental screw fixation and 97.1% with nonsegmental screw fixation. Nonsegmental screw fixation may contribute to less than adequate stability and contribute to a higher rate of nonunion, but such effects could not be discerned from this study. Excellent and good clinical outcome was noted in 88.8% of the patients. Proper patient selection and meticulous operative technique is essential to obtain high fusion rates and optimal clinical outcome, which is more important than graft type.

Adult↗

INTRAMITOCHONDRIAL FIBERS WITH DNA CHARACTERISTICS. I. FIXATION AND ELECTRON STAINING REACTIONS.

Chick embryo mitochondria, studied with the electron microscope, show crista-free areas of low electron opacity. These areas are observable after fixation with osmium tetroxide, calcium permanganate, potassium permanganate, formaldehyde, acrolein, acrolein followed by osmium tetroxide, uranyl acetate followed by calcium permanganate, and acetic acid-alcohol. Staining of sections with lead hydroxide or uranyl acetate, or with both, resulted in an increased density of a fibrous material within these areas. The appearance of the fibrous structures varied with the fixative employed; after fixation with osmium tetroxide the material was clumped and bar-like (up to 400 A in diameter), whereas after treatment of osmium tetroxide-fixed tissues with uranyl acetate before dehydration the fibrous structures could be visualized as 15 to 30 A fibrils. Treatment with ethylenediaminetetraacetate (EDTA) in place of uranyl acetate coarsened the mitochondrial fibrils. After fixation with calcium permanganate or potassium permanganate, or a double fixation by uranyl acetate followed by calcium permanganate, the fibers appeared to have a pattern and ultrastructure similar to that observed after the osmium tetroxide-uranyl acetate technique, except that some of them had a slightly greater diameter (up to 50 A). Other fixatives did not preserve the fibers so well. The fibers appeared strongly clumped by formaldehyde fixation, and were difficult to identify after fixation with acrolein or acetic acid-alcohol. The staining of nucleic acid-containing structures by uranyl acetate and lead hydroxide was improved by treatment of osmium tetroxide-fixed sections with hydrogen peroxide, and the mitochondrial fibers also had an increased density in the electron beam after this procedure. The staining characteristics suggest the fibrous material of chick embryo mitochondria to be a nucleic acid-containing structure, and its variable appearance after different fixations parallels that previously reported, or described in this paper, for the nucleoplasm of bacteria and blue-green algae. The results, in addition to those described in the accompanying communication, indicate that these mitochondria contain DNA.

Animals↗

Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement.

The increased popularity of pedicle fixation prompted research to address two issues: the reliability and validity of roentgenograms as a technique for evaluating the success of pedicle fixation, and the effects of surgical factors on successful fixation. Thus, does approach--the point and angle of screw insertion, surgeon experience, practice, level of the spine involved, and screw size--effect success of pedicle fixation? Eight fresh thoracolumbar spines were harvested and cleaned of all soft tissues. Two surgeons, one more experienced in pedicle fixation than the other, used two pedicle fixation approaches (Weinstein and Roy-Camille) on both the left and right sides at levels T11-S1 of each specimen. All screws were placed under anteroposterior (AP) and lateral c-arm control. For specimens 1 to 3, 5.5 mm screws were used at T11-L1, and 7.0 mm screws at L2-S1. Unacceptable failure rates at L2 and L3 for the first three specimens resulted in a change of instrumentation for the remaining specimens, with 5.5 mm screws used at T11-L3 and 7.0 mm screws at L4-S1. When surgeons completed the fixations for a specimen, AP and lateral roentgenograms were taken and both surgeons independently evaluated the films to assess the success of each fixation. Failure was defined as evidence of any cortical perforation on any side of the pedicle in or outside of the spinal canal. After completing the roentgenogram evaluation, the specimen was transected in the midline, and the success of each pedicle fixation was evaluated by visual/tactile inspection. There were no disagreements between surgeons on the visual/tactile evaluations of the specimens.(ABSTRACT TRUNCATED AT 250 WORDS)

Bone Screws↗

Anatomic considerations of anterior transarticular screw fixation for atlantoaxial instability.

STUDY DESIGN: Anatomic parameters of C1 and C2 were measured in 30 dried human cervical spines. Anterior transarticular C1-C2 screws were placed in 15 cadaveric spines. OBJECTIVE: To provide anatomic data for anterior transarticular atlantoaxial screw or C1-C2 screw and plate fixation. SUMMARY OF BACKGROUND DATA: A posterior approach to fixation in the atlantoaxial joint has been well described. Damage to the vertebral artery is documented as a rare complication of posterior atlantoaxial transarticular screw fixation. An anterior surgical approach to exposing the upper cervical spine for internal fixation and bone graft recently has been developed. No anatomic information regarding the anterior transarticular atlantoaxial screw or screw and plate fixation between C1 and C2 is available in the literature. METHODS: Direct measurements using digital calipers and a goniometer were taken from 30 pairs of dried human C1 and C2 vertebrae. The anterior transarticular C1-C2 screw insertion point is at the junction of the lateral edge of the C2 vertebral body to 4 mm above the inferior edge of the C2 anterior arch. The parameters related to anterior transarticular atlantoaxial screw fixation or screw and plate fixation between the C1 lateral mass and the C2 vertebral body were measured. Fifteen embalmed cadavers were used for anterior C1-C2 transarticular screw placement. Longer screws (30-40 mm) were used to detect whether the screw tips violated the upper cervical canal or vertebral arteries. RESULTS: In the anterior transarticular atlantoaxial screw placement, lateral angulation of the screw placement relative to sagittal plane ranged from 4.8 +/- 1.8 degrees to 25.3 +/- 2.6 degrees. The posterior angulation of the screw placement relative to the coronal plane ranged from 12.8 +/- 3.1 degrees to 22.6 +/- 3.2 degrees. The length of the medial screw path ranged from 14.7 +/- 1.5 mm to 25.4 +/- 2.8 mm. In the anterior screw and plate fixation, the anteroposterior diameter of the inferior facet articular surface ranged from 16.2 +/- 1.6 mm to 17.1 +/- 1.8 mm. The anteroposterior diameter of the C2 vertebral body ranged from 9.3 +/- 1 mm to 16.2 +/- 1.8 mm. The anterior prevascular retropharyngeal approach appropriately exposed the atlantoaxial joint for anterior transarticular C1-C2 screw placement. No screws violated the vertebral artery and cervical canal. CONCLUSIONS: An anterior transarticular atlantoaxial screw 15-25 mm long can be inserted with a lateral angulation of 5-25 degrees relative to the sagittal plane and a posterior angulation of 10-25 degrees relative to the coronal plane. Additionally, in C1-C2 anterior plate fixation screws 15 mm long could be anchored in the inferior facet of the C1, and screws 9-15 mm long could be anchored in the C2 vertebral body.

Aged↗

Complications of pedicle screw fixation in reconstructive surgery of the cervical spine.

STUDY DESIGN: Retrospective evaluation of complications in 180 consecutive patients with cervical disorders who had been treated by using pedicle screw fixation systems. OBJECTIVES: To determine the risks associated with pedicle screw fixation in the cervical spine and to emphasize the importance of preoperative planning and surgical techniques in reducing the risks of this procedure. SUMMARY OF BACKGROUND DATA: Generally, pedicle screw fixation in the cervical spine has been considered too risky for the neurovascular structures. There have been several reports describing the complications of lateral mass screw-plate fixation. However, no studies have examined in detail the complications associated with cervical pedicle screw fixation. METHODS: One hundred eighty patients who underwent cervical reconstructive surgery using cervical pedicle screw fixation were reviewed to clarify the complications associated with the pedicle screw fixation procedure. Cervical disorders were spinal injuries in 70 patients and nontraumatic lesions in 110 patients. Seven hundred twelve screws were inserted into the cervical pedicles, and the locations of 669 screws were radiologically evaluated. RESULTS: Injury of the vertebral artery occurred in one patient. The bleeding was stopped by bone wax, and no neurologic complication developed after surgery. On computed tomographic (CT) scan, 45 screws (6.7%) were found to penetrate the pedicle, and 2 of 45 screws caused radiculopathy. Besides these three neurovascular complications directly attributed to screw insertion, radiculopathy caused by iatrogenic foraminal stenosis from excessive reduction of the translational deformity was observed in one patient. CONCLUSIONS: The incidence of the clinically significant complications caused by pedicle screw insertion was low. Complications associated with cervical pedicle screw fixation can be minimized by sufficient preoperative imaging studies of the pedicles and strict control of screw insertion. Pedicle screw fixation is a useful procedure for reconstruction of the cervical spine in various kinds of disorders and can be performed safely.

Adolescent↗

Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note.

Rigid screw fixation of the axis, for either atlantoaxial fixation or for incorporation of C2 into subaxial cervical constructs, provides significant stability and excellent long-term fusion results but remains technically demanding due to the danger of injury to the vertebral artery. Anatomic variability of the foramen transversarium in the body of the axis can preclude safe transarticular C1-C2 screw placement in up to 20% of patients. Although more recent methods of C2 screw fixation with pedicle screws allow safer fixation in a higher number of patients, there remains a significant risk to the vertebral artery with C2 pedicle screw placement. The author describes a novel technique of C2 rigid screw fixation using bilateral, crossing C2 laminar screws, not previously reported in the literature, which does not place the vertebral artery at risk during C2 fixation. This technique has been successfully used by the author in cases of craniocervical and atlantoaxial fixation as well as for incorporation of C2 into subaxial fixations. The technique is illustrated, and the author's initial experience in treating 10 patients with crossing, bilateral C2 aminar screws for indications of trauma, neoplasm, pseudarthrosis, and degenerative disease is reviewed. The possible advantages of C2 fixation with C2 laminar screws are discussed.

Adult↗

Biomechanical assessment of conventional unit rod fixation versus a unit rod pedicle screw construct: a human cadaver study.

STUDY DESIGN: Fresh frozen human cadaver specimens were used to perform a biomechanical assessment focusing on spinal-pelvic fixation. Unit rod fixation alone was compared with that of unit rod fixation supplemented with L5 pedicle screws. OBJECTIVES: To investigate the biomechanical effects of adding L5 pedicle screw fixation to a unit rod construct. SUMMARY OF BACKGROUND DATA: The treatment of neuromuscular scoliosis associated with pelvic obliquity continues to evolve. Spinal fusion using fixation extending from the thoracic spine to the pelvis supplemented with segmental instrumentation has become the standard of care. The instrumentation of choice used at this institution has been a unit rod construct. Traditional Luque-Galveston technique with sublaminar wiring from T2 to L5 has been used. A noted complication has been a loss of distal fixation, the emphasis for this study. We have subsequently modified this technique, replacing wires at L5 with pedicle screws. This was done to improve the strength of the distal fixation, with the goal of decreasing the rate of instrumentation failure before fusion. METHODS: Twelve fresh-frozen human cadavers, between the ages of 45 and 60 years, were instrumented from T4 to the pelvis with a Unit Rod (Sofamor Danek). The specimens were randomized into two groups. Segmental sublaminar wiring was performed from T4 to L5 in one group of six spines. The remaining six spines underwent sublaminar wiring from T4 to L4, with pedicle screws used for L5 fixation. The spines were then potted from T4 to T7 in preparation for biomechanical testing. The spines were tested in a randomized fashion for subfailure stiffness in anteroposterior, oblique, and lateral planes with an Instron 1321 servo-hydraulic load frame (Instron Corp., Canton, MA). Each spine was then loaded to failure in forward flexion. RESULTS: Our results demonstrate a statistically significant increase in lateral stiffness (P = 0.0006) and oblique stiffness (P = 0.003) associated with the use of L5 pedicle screws. Statistical significance was also achieved with load to failure testing (P = 0.0007). The mean load to failure was 1377 Newtons for the pedicle screw construct and 467 Newtons for the wire construct. CONCLUSIONS: We conclude that the addition of L5 pedicle screws increases the stiffness and strength of the unit rod construct. Clinically, this should help to avoid complications associated with loss of fixation in this area.

Biomechanical Phenomena↗

Response of carbon dioxide fixation to water stress: parallel measurements on isolated chloroplasts and intact spinach leaves.

Application of water stress to isolated spinach (Spinacia oleracea) chloroplasts by redutcion of the osmotic potentials of CO(2) fixation media below -6 to -8 bars resulted in decreased rates of fixation regardless of solute composition. A decrease in CO(2) fixation rate of isolated chloroplasts was also found when leaves were dehydrated in air prior to chloroplast isolation. An inverse response of CO(2) fixation to osmotic potential of the fixation medium was found with chloroplasts isolated from dehydrated leaves-namely, fixation rate was inhibited at -8 bars, compared with -16 or -24 bars.Low leaf water potentials were found to inhibit CO(2) fixation of intact leaf discs to almost the same degree as they did CO(2) fixation by chloroplasts isolated from those leaves. CO(2) fixation by intact leaves was decreased by 50 and 80% when water potentials were reduced from -7.1 to -9.6 and from -7.1 to -17.6 bars, respectively. Transpiration was decreased by only 40 and 60%, under the same conditions. However, correction for the increase in leaf temperature indicated transpiration decreases of 57 and 80%, similar to the relative decreases in CO(2) fixation.Despite the 4-fold increase in leaf resistance to CO(2) diffusion in the gas phase when the water potential of leaves was reduced from -6.5 to -14.0 bars, an additional increase of about 50% in mesophyll resistance was obtained. CO(2) concentration at compensation also increased when leaf water potential was reduced.

Journal Article↗

Interpreting the multifocal visual evoked potential: the effects of refractive errors, cataracts, and fixation errors.

AIM: To understand how refractive errors, cataracts, and fixation errors affect multifocal visual evoked potential (mfVEP) responses. METHODS: Monocular mfVEP responses were obtained using a pattern reversal dartboard display. For the control condition, visual acuity was corrected to > or =20/20 and foveal fixation was maintained. The right eye was tested under the following conditions: simulated refractive error, simulated cataract, steady eccentric fixation, and unsteady fixation. RESULTS: No subject demonstrated significant abnormalities under control conditions. For the simulated refractive error condition, significant centrally located abnormalities were seen for all subjects. For the simulated cataract condition, significant abnormalities were found for three subjects. The steady eccentric fixation condition yielded abnormalities in both eyes for all subjects while the unsteady fixation condition yielded significant central abnormalities in the tested eye. With eccentric and unsteady fixation conditions, all subjects had at least one sector with a waveform polarity reversal. CONCLUSIONS: While the mfVEP is a useful tool for identifying local optic nerve damage or ruling out non-organic aetiology of visual field defects, factors such as uncorrected refractive errors, cataract, eccentric fixation, and unsteady fixation can produce apparent field defects on the mfVEP. With care, these problems can be correctly identified.

Adult↗

Stress distribution in the supraspinatus tendon after tendon repair: suture anchors versus transosseous suture fixation.

BACKGROUND: The stress concentration at the site of supraspinatus tendon repair, either by suture anchor fixation or by transosseous suture fixation, has not been fully clarified. HYPOTHESIS: Suture anchor fixation showed higher stress concentrations in the tendon than did transosseous suture fixation. STUDY DESIGN: Controlled laboratory study. METHODS: Three finite element models were developed based on a previously published model of normal supraspinatus tendon (0 degrees abduction). Single-row fixation, double-row fixation, and transosseous suture fixation were simulated. A tensile force was applied to the proximal end of the supraspinatus tendon to simulate its contraction force. RESULTS: In the single-row model, the stress appeared from the site of the anchor and extended into the proximal tendon. The highest stress concentration was observed on the bursal surface of the tendon. The double-row model showed a similar pattern to the single-row model except that the stress concentration was observed only around the medial anchor. In the transosseous model, the stress appeared from the attachment site to a bony trough, which extended proximally into the tendon substance. No significant stress concentration was observed inside the tendon. CONCLUSION: Both single-row and double-row fixations showed higher stress concentration inside the tendon than did transosseous suture fixation. CLINICAL RELEVANCE: A high stress concentration might be a cause of the rerupture often observed after arthroscopic cuff repair using suture anchors.

Adaptation, Physiological↗

A biomechanical evaluation of three forms of internal fixation used in ankle arthrodesis.

A biomechanical study was undertaken to evaluate the relative stability of three types of internal fixation used for ankle arthrodesis. Crossed screw fixation, RAF fibular strut fixation, and T-plate fixation were tested in 30 cadaver ankles using an MTS machine. T-plate fixation consistently provided the stiffest construct when compared with the other types of fixation. Failure occurred by distraction of bony surfaces, posterior to the plane of fixation, in the crossed screw and RAF groups. In contrast, failure in the T-plate group occurred through compression of bone anterior to the midcoronal plane of the tibia. Although the stability of fixation is only one factor in determining the success or failure of ankle arthrodesis, the results of this study would support T-plate fixation over the other forms tested.

Ankle Joint↗

Determination of protein loss during aqueous and phase partition fixation using formalin and glutaraldehyde.

In phase partition fixation tissue is immersed in an organic solvent at equilibrium with an aqueous phase containing a fixing agent. By using radioisotope labeling techniques the effects of phase partition fixation on protein retention during fixation of tissue with formalin and glutaraldehyde have been determined and compared with those of standard aqueous fixation using these fixatives. It has been shown that retention of protein in tissue during phase partition fixation was as good or better than during aqueous fixation. Improved retention provides further evidence that phase partition fixation may be a useful alternative to aqueous fixation.

Animals↗

Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation.

BACKGROUND: Recent studies have shown that arthroscopic rotator cuff repairs can have higher rates of failure than do open repairs. Current methods of rotator cuff repair have been limited to single-row fixation of simple and horizontal stitches, which is very different from open repairs. The objective of this study was to compare the initial cyclic loading and load-to-failure properties of double-row fixation with those of three commonly used single-row techniques. METHODS: Ten paired human supraspinatus tendons were split in half, yielding four tendons per cadaver. The bone mineral content at the greater tuberosity was assessed. Four stitch configurations (two-simple, massive cuff, arthroscopic Mason-Allen, and double-row fixation) were randomized and tested on each set of tendons. Specimens were cyclically loaded between 5 and 100 N at 0.25 Hz for fifty cycles and then loaded to failure under displacement control at 1 mm/sec. Conditioning elongation, peak-to-peak elongation, ultimate tensile load, and stiffness were measured with use of a three-dimensional tracking system and compared, and the failure type (suture or anchor pull-out) was recorded. RESULTS: No significant differences were found among the stitches with respect to conditioning elongation. The mean peak-to-peak elongation (and standard error of the mean) was significantly lower for the massive cuff (1.1 +/- 0.1 mm) and double-row stitches (1.1 +/- 0.1 mm) than for the arthroscopic Mason-Allen stitch (1.5 +/- 0.2 mm) (p < 0.05). The ultimate tensile load was significantly higher for double-row fixation (287 +/- 24 N) than for all of the single-row fixations (p < 0.05). Additionally, the massive cuff stitch (250 +/- 21 N) was found to have a significantly higher ultimate tensile load than the two-simple (191 +/- 18 N) and arthroscopic Mason-Allen (212 +/- 21 N) stitches (p < 0.05). No significant differences in stiffness were found among the stitches. Failure mechanisms were similar for all stitches. Rotator cuff repairs in the anterior half of the greater tuberosity had a significantly lower peak-to-peak elongation and higher ultimate tensile strength than did repairs on the posterior half. CONCLUSIONS: In this in vitro cadaver study, double-row fixation had a significantly higher ultimate tensile load than the three types of single-row fixation stitches. Of the single-row fixations, the massive cuff stitch had cyclic and load-to-failure characteristics similar to the double-row fixation. Anterior repairs of the supraspinatus tendon had significantly stronger biomechanical behavior than posterior repairs.

Adult↗

A biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation.

OBJECT: The purpose of this study was to compare cable techniques used in occipitocervical fixation with two types of screw fixation. The authors hypothesized that screw fixation would provide superior immobilization compared with cable methods. METHODS: Ten cadaveric specimens were prepared for biomechanical analyses by using standard techniques. Angular and linear displacement data were recorded from the occiput to C-6 with infrared optical sensors after conditioning runs. Specimens underwent retesting after fatiguing. Six methods of fixation were analyzed: Steinmann pin with and without C-1 incorporation; Cotrel-Dubousett horseshoe with and without C-1 incorporation; Mayfield loop with C1-2 transarticular screw fixation; and a custom-designed occipitocervical transarticular screw-plate system. Sublaminar techniques were extended to include C-3 in the fusion construct, whereas transarticular techniques incorporated the occiput, C-1, and C-2 only. All methods of fixation provided significant immobilization in all specimens compared with the nonconstrained destabilized state. Despite incorporation of an additional vertebral segment, sublaminar techniques performed worse as a function of applied load than screw fixation techniques. Following fatiguing, these differences were more pronounced. The sublaminar techniques failed most prominently in flexion-extension and in axial rotation. On gross inspection, increased angular displacement associated with loosening of the sublaminar cables was observed. CONCLUSION: Occipitocervical fixation can be performed using a variety of techniques; all bestow significant immobilization compared with the destabilized spine. All methods tested in this study were susceptible to fatigue and loss of reduction and were weakest in resisting vertical settling. Screw fixation of the occiput-C2 reduces the number of vertebral segments that are necessary to incorporate into the fusion construct while providing superior immobilization and resistance to fatigue and vertical settling compared with sublaminar methods.

Analysis of Variance↗

[Harms technique of C1-C2 fixation with polyaxial screws and rods].

PURPOSE OF THE STUDY: The Harms technique of stabilizing C1-C2 by fixation with polyaxial screws and rods is a further option for atlantoaxial fixation from the dorsal approach. Harms and Melcher published this method in 2001, but the operation had first been performed by Harms in August 1997. The aim of this study is to evaluate the first results and try to assign the Harms C1-C2 fixation an appropriate standing in the in broad range of options for stabilization of the atlantoaxial complex. MATERIAL: Between December 2002 and January 2004 we carried out the Harms fixation of C1-C2 on 22 patients admitted to the Department of Spine Surgery, Motol University Hospital, 2nd Medical Faculty in Prague. Out of these, 18 patients were included in this study, 10 men and 8 women between 23 and 84 years of age (average, 55.4 years) followed-up longer than 6 months. In 14 patients we used the Harms technique as a permanent fixation of C1-C2 in order to achieve atlantoaxial arthrodesis and, in four patients, we applied it only for a period of 4 to 6 months without the use of bone grafts or their substitutions. We employed the permanent fixation to treat the following conditions: fracture of the atlas in three patients, type IIA comminuted fracture of the dens base in three patients, fracture of C2 categorized as "other" in two patients, atlantoaxial vertical instability in one patient with rheumatoid arthritis, malunion of the fractured dens in one patient, and complicated trauma to C1-C2 in four patients. The temporary fixation was used for type III displaced fractures of the dens in two and fixed atlantoaxial rotatory dislocations also in two cases. Only one patient showed signs of Frankel C neurological deficit on admission, the rest were without neurological findings. METHODS: All screws were inserted under an image intensifier always in lateral projection. First we retracted the greater occipital nerve in a caudal direction towards C2 with a fine raspatory and, using an awl, marked the entry point in the C1 lateral mass; a pilot hole, reaching through the anterior cortical bone, was made with a 2.5 mm drill. It followed a straight or slightly convergent trajectory in an anterior-posterior direction and parallel to the plane of the C1 posterior arch in the sagittal direction. Individual anatomical variations in the atlantoaxial complex of every patient were respected. The hole was tapped through the entire vertebral body, with the exception of osteoporous bone in which only the posterior cortical bone was treated with a screw tap. At this stage profuse bleeding usually arose from dissection around the epidural venous plexus along the C1-C2 joint. This was effectively controlled by a quick insertion of a screw and compression of the venous plexus with the screw head. To control bleeding by bipolar electrocautery is difficult and is always associated with a risk of nerve injury. Screws 3.5 mm thick, with polyaxial heads, were inserted bicortically into the lateral mass of C1. Subsequently, the intervertebral C2-C3 joint was localized and its medial border in the spinal canal was palpated. The entry point for placement of a C2 pedicle screw was marked with an awl at the point of intersection at a distance of 2 mm from the medial border and 5 mm from the caudal border of the C2 articular process. Under an X-ray intensifier in lateral projection, a hole was drilled approximately parallel to the screws inserted in C1, i. e., at an angle of 20 to 30 degrees cranially, up to and through the anterior cortical bone. In the transversal plane, the screws were situated in a convergent direction at an angle of 20 to 25 degrees. After all screws had been inserted, we reduced the antlantoaxial complex in the correct anatomical position by manipulating the patient's head or by directly adjusting the screws. Connecting 3.0-mm rods were then applied and fastened by cap nuts or inner nuts according to the instrumentation used. RESULTS: Operative time ranged from 35 to 155 min, with an average of 81 min. Intra-operative blood loss ranged from 50 to 1500 ml, with an average of 560 ml. The X-ray intensifier was used for a period of 0.4 to 2.6 min, with an average of 0.9 min. A total of 36 screws were inserted in the atlas; their length ranged from 16 to 34 mm (average, 30.6 mm). All screws were positioned correctly in the C1 lateral mass; two screws did not reach up to the anterior cortical bone and one protruded over it, but without causing clinical problems. Thirty-six screws were inserted in the axis. Their length ranged from 28 to 36 mm (average, 31.7) mm). Twenty-seven screws were correctly applied through the isthmus into the C2 anterior cortical bone, three were too short to reach it and five were placed too close to the vertebral artery canal. Of these, two protruded into the artery canal, but without clinical consequences. One screw inserted too medially passed into the spinal canal, but this also was without clinical response. Of the 36 screws inserted in C2, three (8.3 %) were malpositioned. Bony fusion at C1-C2 was the goal of this operation in 14 patients. At 6 weeks post-operatively, it was achieved in two patients, at 12 weeks in 12 patients and at 6 months in all 14 patients. The C1-C2 segment was stable at 12 weeks in all 18 treated patients. Four patients reported restriction of motion in rotation by 10 to 25 % after removal of the instrumentation. DISCUSSION: Operative time, longer at the beginning than with the Magerl technique, gradually shortened to between 45 and 60 min. Similar trends were seen when intra-operative blood loss and X-ray exposure were evaluated. Using the Harms and Melcher procedure we saved the greater suboccipital nerve. In contrast to these authors, however, we did not resect the atlantoaxial joint. Solid fusion was achieved in all our patients. Of the total of 72 screws inserted, only three (4.2 %) were assessed as malpositioned; however, when related to the 36 screws inserted in C2, this was 8.3 %, which indicates that insertion of screws in C2 was more difficult. We did not observe any clinical consequences in any of these cases. CONCLUSIONS: The Harms fixation of C1-C2 is a very effective technique for stabilizing the atlantoaxial complex. It enables us to provide temporary fixation without damage to atlantoaxial joints and to reduce the vertebrae after the screws and rods had been inserted, which is unique. These advantages compensate for a higher cost of the implant.

Adult↗