Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ejection fraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Rest versus stress ejection fraction on gated myocardial perfusion SPECT.

OBJECTIVES: It is widely accepted that exercise-induced stunning has an impact on left ventricular ejection fraction (EF); yet, despite the recommendations of the American Society of Nuclear Cardiology, many departments only perform gated SPECT on stress studies. The aim of this investigation was to determine the relationship between rest EF and stress EF in myocardial perfusion studies and to identify possible predictors of variability. METHODS: This study was a retrospective cross-sectional study of 133 patients (266 studies) undergoing myocardial perfusion SPECT. Automated computer-generated functional data (end-diastolic volume, end-systolic volume [ESV], and EF) for rest and stress studies were correlated as matched pairs and analyzed with respect to the following variables: age, sex, stress method, time between stress and scanning, and presence or absence of pathology scintigraphically. Differences in matched EF pairs (DeltaEF) and transient dilatation were also determined. RESULTS: Matched pairs of rest EF and stress EF demonstrated excellent correlation (0.90) with no significant difference noted (P=0.15). Bland-Altman analysis demonstrated a mean DeltaEF of -0.65% (95% confidence interval [CI], -1.54% to 0.23%) with 94% of data points within the 95% limits of agreement. No statistically significant difference was determined between the mean DeltaEF and the hypothetic mean of 0 (P=0.15). A time between stress and scanning of <45 min was shown to be predictive of a negative DeltaEF (P=0.04). Transient dilatation was shown to be predictive of a negative DeltaEF (P=0.01). Resting ESVs between 25 and 50 mL were shown to be predictive of a negative DeltaEF (P=0.02). A stress EF of <50% was also shown to be predictive of a negative DeltaEF (P=0.003). CONCLUSION: No statistically significant difference between stress and rest EF was demonstrated and no trend was identified toward either under- or overestimation of the stress EF with a DeltaEF. A negative DeltaEF was, however, predicted by transient dilatation of >1.0, a time between stress and scanning of <45 min, a stress EF of <50, and an ESV between 25 and 50 mL. Gated SPECT performed on both stress and rest studies may provide a mechanism to predict exercise-induced stunning and transient dilatation.

Adult↗

[Assessment of the ejection fraction in ischemic cardiopathy with two-dimensional echocardiography. Validity and limits of the method].

In this study the authors compare the Ejection Fraction (EF) as determined by the Single Plane Ellipse Echocardiographic method versus the Ventriculographic EF. The authors emphasize the validity of the two-dimensional echocardiography to assess left ventricular EF in order to improve the clinical and pharmacologic management of the patients with the cardiac ischaemic disease.

Aged↗

Variation in left ventricular ejection fraction determination at rest and during exercise.

The results of multi-gated blood pool imaging (MBPI) for determination of left ventricular ejection fraction (LVEF) in 48 patients at rest and during exercise were analysed in order to evaluate observer variance and interstudy variance. Twenty-three MBPI studies carried out with the patient at rest and 37 studies carried out during graded ergometer exercise were analysed by two independent observers in order to determine intra- and inter-observer variance. On the intra-observer level regression analysis yielded excellent correlation between rest and exercise studies (r = 0,998 at rest, r = 0,964 during exercise), and showed no statistically significant difference (P less than 0,01); this was also true of the inter-observer measurements (r = 0,999 at rest, r = 0,988 during exercise). In order to evaluate interstudy variance, MBPI was repeated in 15 patients at rest. Interstudy variation of the LVEF was minimal as indicated by regression analysis (r = 0,98), and showed no statistically significant difference (P less than 0,01). During the repeat study a mean increase in the LVEF of 2,1% was obtained, but this difference was not statistically significant.

Adolescent↗

Ejection fraction and heart rate correlate with diastolic peak filling rate at rest and during exercise.

We investigated the independent variables correlating with the multigated radionuclide peak filling rate (PFR) at rest and during supine bicycle exercise in 20 normal individuals. Independent variables were systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), ejection fraction (LVEF), time to PFR (TPFR), peak ejection rate (PER) and time to PER (TPER). Fifteen subjects completed at least five stages of exercise at 25 watts each. Correlating independent variables were selected by a forward-backward stepwise multiple linear regression (BMDP2R). A partial correlation statistical program was also used to allow control of critical independent variables. The final regression equations were: a) resting state, PFR = -2.5 + 0.03HR + 0.05LVEF + 0.02SBP-0.02DBP, and b) exercise state, PFR = -3.8 + 0.04HR + 0.08LVEF. All independent variables mentioned above correlated with PFR (simple correlations designated as zero partials). However, when LVEF and HR were held constant (second order partials), the correlation of PFR with any of the other independent variables disappeared. In summary, the radionuclide global LV PFR is predominantly correlated to LVEF and HR at rest and during exercise. These correlations should be considered when assessing exercise effects of disease states on PFR.

Adult↗

HIDA scan ejection fraction does not predict sphincter of Oddi hypertension or clinical outcome in patients with suspected chronic acalculous cholecystitis.

BACKGROUND: Hepatobiliary iminodiacetic scan with ejection fraction (HIDA EF) is used to evaluate chronic acalculous cholecystitis (CAC). A presumed etiology of CAC is sphincter of Oddi hypertension (SOH). In this study, we evaluated the value of HIDA EF to predict patient response to laparoscopic cholecystectomy and to identify SOH. METHODS: A prospective study of 93 patients with biliary pain but without gallstones (CAC) who underwent preoperative HIDA EF was conducted. At laparoscopic cholecystectomy, transcystic antegrade biliary manometry was performed to determine the SO pressure. Patients were evaluated postoperatively for response to cholecystectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. The outcomes were compared with the clinical impression. RESULTS: Of the 93 patients with both HIDA EF and SOP measurements, 50 had abnormal EF (< 35%); of these, 29 had SOH (SO pressure > or = 40 mmHg). Of the 43 patients with normal HIDA EF, 30 had SOH. The sensitivity was 49%, specificity 38%, PPV 58%, and NPV 30%. Eighty-six of the 93 patients returned for follow-up evaluation. Follow-up ranged from 0 to 99 months, with a mean of 26.4 months. Overall, 73 patients (85%) improved. Of the 46 with abnormal HIDA EF, 42 (91%) improved. Of the 40 patients with normal HIDA EF, 31 (77.5%) improved. The sensitivity was 57.7%, specificity 69.2%, PPV 91.3%, and NPV 22.5%. CONCLUSION: Although the PPV of abnormal HIDA EF is high, it is not much better than the clinical impression. The sensitivity and specificity are marginal. The NPV is poor. Based on the review of these 93 patients, HIDA EF is not reliable for identifying CAC. We recommend that patients with normal HIDA EF have additional testing or consultation before ruling out CAC. HIDA EF does not predict SOH.

Acalculous Cholecystitis↗

Determination of left ventricular volumes and ejection fraction by nuclear magnetic resonance imaging.

To determine the ability of nuclear magnetic resonance (NMR) imaging to assess left ventricular (LV) volumes and ejection fraction (EF), we studied 24 patients within 48 hours of single-plane LV angiography. In all patients, a transverse, single-plane NMR acquisition technique was employed with LV end-diastolic (ED) and end-systolic (ES) volumes (V) calculated by a modified area-length algorithm. In nine patients, a multislice acquisition technique was employed with LVEDV and LVESV calculated by a Simpson's rule algorithm. NMR-determined LVV and EF correlated reasonably well with angiographic values (LVEDV: r = 0.75; LVESV: r = 0.90; and LVEF: r = 0.76). The single-plane NMR technique significantly underestimated LVEDV (p less than 0.01), whereas no significant difference was demonstrated for LVESV. As a result, angiographic LVEF was significantly underestimated (p less than 0.05). This underestimation is likely related to off-axis imaging and to the geometric constraints of a single-plane algorithm. In comparing multislice NMR to angiographic data, no significant difference was demonstrated for LVEDV, LVESV, or LVEF. Thus, quantitation of LVV and EF with NMR is feasible, and comparison to angiographic volumes is similar to results reported from other noninvasive imaging modalities. Improvement in current acquisition techniques and software should result in further quantitative potential.

Adult↗

Increased left ventricular ejection fraction after a meal: potential source of error in performance of radionuclide angiography.

The effect of a standardized meal on left ventricular (LV) ejection fraction (EF) was determined by equilibrium radionuclide angiography in 16 patients with stable congestive heart failure but without pulmonary or valvular heart disease. LVEF was determined in the fasting state and 15, 30, and 45 minutes after a meal. Patients with moderately depressed fasting LVEF (30 to 50%), Group I, had a mean increase of 6.9 +/- 2.9% (p less than 0.005) in the LVEF at 45 minutes after the meal. Patients with severely depressed fasting LVEF (less than 30%), Group II, had no change after the meal. It is concluded that significant increases in LVEF may occur after meals in patients with moderate but not severe left ventricular dysfunction. Equilibrium radionuclide angiography studies that are not standardized for patients' mealtimes may introduce an important unmeasured variable that will affect the validity of data in serial studies of left ventricular function.

Adult↗

Right ventricular ejection fraction measurement: contrast ventriculography versus gated blood pool and gated first-pass radionuclide methods.

Radionuclide methods of measuring the right ventricular (RV) ejection fraction (EF) provide noninvasive means of evaluating right-sided cardiac function at rest and exercise. This study compared 2 radionuclide methods with a cast-validated contrast angiographic method of RVEF analysis in 21 consecutive patients who underwent RV contrast ventriculography and gated equilibrium blood pool radionuclide ventriculography. Eleven subjects had gated first-pass radionuclide studies that were technically adequate for EF analysis. RVEF was calculated by different operators for the contrast and radionuclide methods. The close correlation of the contrast angiographic method with both equilibrium blood pool and first-pass radionuclide methods supports the use of the radionuclide techniques.

Adult↗

Usefulness of ejection fraction response to exercise one month after acute myocardial infarction in predicting coronary anatomy and prognosis.

The prognostic value of left ventricular (LV) ejection fraction (EF) measured during maximal exercise testing early after acute myocardial infarction (AMI) was assessed in 75 patients, aged 65 years or younger, a mean of 36 days after AMI. At follow-up for a mean 12 months (range 6 to 26), medical complications developed in 15 patients: cardiac death in 5, ventricular fibrillation in 1, reinfarction in 2, unstable angina in 5, and severe cardiac failure in 2. Seven other patients underwent coronary artery bypass grafting for severe angina. When LVEF less than 50% at rest was compared with LVEF of 50% or more, the 2-year life-table survival free of complications was 54 +/- 21% compared with 84 +/- 19% (p less than 0.05). When exercise LVEF less than 50% was compared with LVEF of 50% or more, the 2-year survival rate free of medical complication was 42 +/- 32% compared with 83 +/- 20% (p less than 0.05). LVEF change from rest to exercise was not related to prognosis. Patients with combined medical and surgical events tended to have lower rest and exercise LVEFs, but changes in LVEF during exercise were again unrelated to prognosis. Sixty-five patients underwent coronary arteriography. After inferior AMI the mean LVEF was lower in those with multivessel than in those with 1-vessel coronary artery disease at rest (47 +/- 13% vs 59 +/- 7%, p less than 0.005) and during exercise (47 +/- 13% vs 59 +/- 9%, p less than 0.005); however, the change in LVEF during exercise was not related to coronary anatomy anatomy.(ABSTRACT TRUNCATED AT 250 WORDS)

Actuarial Analysis↗

Comparison of the predictive characteristics of heart rate variability index and left ventricular ejection fraction for all-cause mortality, arrhythmic events and sudden death after acute myocardial infarction.

Heart rate (HR) variability index and left ventricular ejection fraction (EF) were compared for the prediction of all-cause mortality, arrhythmic events and sudden death in 385 survivors of acute myocardial infarction. For arrhythmic events, where, for a sensitivity of 75%, HR variability index had a specificity of 76%, EF had a specificity of only 45%. An EF of less than or equal to 40% had a sensitivity of 42% and a specificity of 75% for arrhythmic events; for the same sensitivity an HR variability index of 20 U had a specificity of 92%. An EF less than or equal to 40% had a sensitivity of 40% and a specificity of 73% for sudden death; HR variability index had a specificity of 83% for the same sensitivity. For all cause mortality, where, for a sensitivity of 75%, HR variability index had a specificity of 52%, EF had a specificity of 40%. It is concluded that HR variability index appears a better predictor of important postinfarction arrhythmic complications than left ventricular EF, but both indexes perform equally well in predicting all-cause mortality.

Adult↗

Left ventricular ejection fraction: single-plane and multiplanar transesophageal echocardiography versus equilibrium gated-pool scintigraphy.

The relative accuracy and precision of estimating left ventricular ejection fraction (EF) in dogs were assessed by two-dimensional transesophageal echocardiography (2D-TEE) and by three-dimensional transesophageal echocardiographic (3D-TEE) imaging and reconstruction. This assessment was accomplished by comparing each echocardiographic method to a gated equilibrium blood pool radionuclide (RN) standard. By using both correlation and regression analysis, 2D-TEE performed reasonably well in estimating RNEF (correlation coefficient [r] = 0.80, slope = 1.01, intercept = 6.37, standard error of the estimate [SEE], 8.98), but not as well as 3D-TEE (r = 0.86, slope = 0.83, intercept = 3.38, SEE, 5.74). Using Altman and Bland's methods of comparison analysis, it was found that 2D-TEE overestimated RNEF by 7% (standard deviation [SD], 8.8). This degree of overestimation was not consistent across the range of measurement. In contrast, 3D-TEE slightly underestimated RNEF by less than 3% and showed less variability (SD, 6.0). The accuracy of the 3D-TEE determinations was not dependent on the magnitude of EF. Additionally, a significantly higher proportion of the 2D-TEE measurements (0.30) compared with the 3D-TEE measurements (0.10) differed from RN values by more than 10% (P = 0.009, McNemar's test). At the clinically important low end of the EF range (RNEF less than or equal to 35%), 2D-TEE may be expected (with 95% confidence) to be within -15% to +28% EF of reference values, whereas 3D-TEE can be expected to be within -8% to +5% EF relative to RN.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Mechanisms of heart failure with well preserved ejection fraction in dogs following limited coronary microembolization.

OBJECTIVE: It has been suggested that in some settings, heart failure (HF) may occur with normal ejection fraction (EF) as a consequence of undetected systolic dysfunction. However, others have argued that this can only occur in the presence of diastolic dysfunction. We therefore sought to determine the contribution of diastolic dysfunction in an animal model of HF with normal EF. METHODS AND RESULTS: Limited myocardial injury was induced in 21 dogs chronically instrumented to measure hemodynamics and LV properties by daily coronary microembolization ( approximately 115 microm beads) until LV end diastolic pressure (LVEDP) was > or =16 mm Hg. Nine dogs developed HF within 16+/-6 days (LVEDP 12+/-2 vs. 21+/-2 mm Hg, p<0.001) with no significant change in dP/dt(max) (2999+/-97 vs. 2846+/-189 mm Hg/s), mean arterial pressure (103+/-4 vs. 100+/-4 mm Hg), EF (57+/-5% vs. 53+/-4%) or E(es) (end-systolic elastance, 3.1+/-0.9 vs. 2.9+/-0.8 mm Hg/ml) but with an approximately 10 ml increase in V(o) (14+/-12 vs. 25+/-16 ml; p<0.01). The EDPVR and time constant of relaxation (tau, 25+/-3 vs. 28+/-3 ms) did not change significantly. These animals were hemodynamically stable out to 3 1/2 months. Neurohormonal activation occurred (elevations of NE, AngII, BNP) and there was intravascular volume expansion by approximately 16% (p<0.05). CONCLUSIONS: A small amount of myocardial injury can lead to neurohormonal activation with intravascular volume expansion and elevation of LVEDP in the absence of reductions in dP/dt(max) or EF and without diastolic dysfunction. Thus, HF with preserved EF does not a priori equate with diastolic heart failure.

Angiotensin II↗

Chronic heart failure with preserved left ventricular ejection fraction: diagnostic and prognostic value of left atrial size.

BACKGROUND: Almost 40% of patients with heart failure (HF) have preserved left ventricular (LV) ejection fraction (EF) and prognosis similar to those with reduced EF. Data on prognostic markers in such patients are limited. We analyzed the prevalence and prognostic value of left atrial (LA) size in this condition. METHODS: 89 normal subjects (Group I), 38 asymptomatic hypertensive patients (Group II) and 183 HF patients with preserved EF (EF >45%) (Group III) were studied. LA diameter (LAD), LV diastolic (LVD) and systolic (LVS) dimensions and mass (LVmass) and EF were measured. E and A wave velocities and E/A were measured. The primary end point was all cause mortality in group III patients. RESULTS: Groups did not differ in age, gender or EF. Group III patients had larger LAD (4.6+-1.0 cm) compared with both Group I (3.7+/-0.6) and Group II (3.7+/-0.5 cm) (p<0.0001). A markedly enlarged (arbitrarily defined as LAD higher or equal 5 cm) had an odds ratio of 34 (95% CI 8-144) in distinguishing HF patients from normals. After a mean follow-up period of 29+/-27 months, 40 patients (21.9%) died. In Cox univariate analysis, NYHA class (HR 2.8 95% C.I. 1.8-4.3; p<0.0001), diastolic blood pressure (DBP) (HR 0.92 95% C.I. 0.88-0.96; p<0.0001), age (HR 1.059 95% C.I. 1.01-1.11; p=0.02) and LAD (HR 1.72 95% C.I. 1.27-2.3; p=0.0005) were predictors of mortality. LAD predicted survival independently of other variables. CONCLUSION: The left atrium is frequently dilated in HF patients compared with controls despite similar EF. LAD showed powerful prognostic value independent of clinical variables.

Aged↗

Optimizing the method to calculate right ventricular ejection fraction from first-pass data acquired with a multicrystal camera.

BACKGROUND: The advantage of radionuclide angiographic techniques used to measure right ventricular ejection fraction (RVEF) is geometry independence, but the weakness is right atrial (RA) overlap. To minimize the effect of RA counts on right ventricular time activity curve (TAC), two regions of interest (ROI), one drawn for the end-diastolic image and one for the end-systolic image, are used for the calculation of RVEF from equilibrium gated blood pool scans (GBPS) and from gated first-pass studies with an Anger camera. A multicrystal camera offers both temporal separation of the bolus to the right side of the heart and good count statistics; therefore first-pass studies performed on a multicrystal camera theoretically should yield the most accurate measurements of RVEF, but few studies have been performed to validate RVEF against a reliable gold standard. METHODS AND RESULTS: To develop and validate an accurate method to measure RVEF from multicrystal first-pass data, 25 patients underwent sequential cine-MRI, first-pass radionuclide angiography, and gated equilibrium imaging. Five additional healthy volunteers underwent cine-MRI alone. Right and left ventricular volumes were measured from serial short axis cine-MRI views according to Simpson's rule. Three methods were used to calculate RVEF from first-pass data: a single ROI method, a dual ROI method, and a method in which a single ROI is applied to RA subtracted first-pass dynamic data. Five additional healthy volunteers underwent cine-MRI alone. When right ventricular stroke volume was plotted versus left ventricular stroke volume for the 5 volunteers and the 15 patients without valvular regurgitation, the regression line was not significantly different from the line of identity, supporting the accuracy of cine-MRI to measure RVEF. The RVEF by cine-MRI ranged from 34% to 59%; first-pass RVEF with a single ROI from 26% to 48%; first-pass RVEF with two ROIs from 31% to 59%; first-pass RVEF with RA subtracted single ROI from 29% to 60%; and RVEF from GBPS with multiple ROIs from 28% to 55%. The regressions for all three of the first-pass methods versus cine-MRI were significant (p < 0.01) as was the regression for the equilibrium GBPS versus cine-MRI but the correlation was weaker. The regressions for the 2-ROI method and for the RA subtracted single ROI method were not significantly different from the line of identity, whereas the regressions for both the single ROI method and for equilibrium GBPS were significantly different from the line of identity (p < 0.01). CONCLUSIONS: Cine-MRI can be used to validate radionuclide algorithms. Of the four radionuclide methods for measuring RVEF that were assessed, the first-pass 2-ROI method and the first-pass RA subtracted single ROI are the most accurate, the first-pass single ROI method underestimates RVEF, and the RVEF values measured from GBPS are less accurate.

Adult↗

Evaluation of ventricular ejection fraction, wall motion, wall thickening, and other parameters with gated myocardial perfusion single-photon emission computed tomography.

Assessment of ventricular function (e.g., ejection fraction, wall motion, wall thickening) during myocardial perfusion single-photon emission computed tomography (SPECT) can serve as a cost-effective technique to provide more diagnostic data with fewer diagnostic tests. With the advent of 99mTc-labeled perfusion agents and advances in technology, myocardial perfusion studies can be augmented on a routine basis to provide additional diagnostic information on ventricular function by use of one gated SPECT acquisition. This technique has the potential to reduce health-care costs by reducing the number of unnecessary coronary angiographies that are now performed on patients with equivocal results of perfusion or incomplete risk stratification from standard myocardial perfusion SPECT.

Coronary Disease↗

The relation between ejection fraction and mitral annulus motion before and after direct-current electrical cardioversion.

Mitral annulus motion (MAM) and the relation between left ventricular ejection fraction (EF) and MAM has been shown to differ between patients with sinus rhythm and patients with atrial fibrillation. However, it has not been investigated how the relation between EF and MAM changes on direct-current (DC) electrical cardioversion to sinus rhythm. Therefore, 31 consecutive patients on the waiting list for DC electrical cardioversion were examined by echocardiography before DC electrical cardioversion, and those who maintained sinus rhythm (13 patients) were examined again 4-8 weeks after cardioversion. The conversion factor (CF) (ratio EF/MAM) decreased from 8.4 +/- 1.7 before to 5.8 +/- 0.8 SD after cardioversion (P<0.001). The EF increased slightly (P<0.05) but the MAM had a much greater increase (P<0.001), resulting in the decrease in CF. There was no significant difference in CF between patients after cardioversion and age- and gender-matched control patients with sinus rhythm, indicating that CF is normalized or almost normalized 4-8 weeks after cardioversion. This indicates that when MAM is used for investigation of the left ventricular function, and the function is expressed as EF, the same CF as in other patients with sinus rhythm can be used 4-8 weeks after DC electrical cardioversion.

Aged↗

Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods.

BACKGROUND: Two methods of computing left ventricular volumes and ejection fraction (EF) from 8-frame gated perfusion single photon emission computed tomography (SPECT) were compared with each other and with magnetic resonance (MR) imaging. METHODS AND RESULTS: Thirty-five subjects underwent 8-frame gated dual-isotope SPECT imaging and 12- to 16-frame gated MR imaging. Endocardial boundaries on short-axis MR images were hand traced by experts blinded to any SPECT results. Volumes and EF were computed with the use of Simpson's rule. SPECT images were analyzed for the same functional variables with the use of 2 automatic programs, Quantitative Gated SPECT (QGS) and the Emory Cardiac Toolbox (ECTb). The mean difference between MR and SPECT EF was 0.008 for ECTb and 0.08 for QGS. QGS showed a slight trend toward higher correlation for EF (r = 0.72, SE of the estimate = 0.08) than ECTb (r = 0.70, SE of the estimate = 0.09). For both SPECT methods, left ventricular volumes were similarly correlated with MR, although SPECT volumes were higher than MR values by approximately 30%. CONCLUSIONS: QGS and ECTb values of cardiac function computed from 8-frame gated perfusion SPECT correlate very well with each other and correlate well with MR. Averaged over all subjects, ECTb measurements of EF are not significantly different from MR values but QGS significantly underestimates the MR values.

Cardiac Volume↗

Right and left ventricular ejection fraction and left ventricular volume changes at rest and during exercise in normal subjects.

The effect of exercise upon right and left ventricular ejection fractions (RVEF and LVEF) as well as the changes upon left ventricular end-diastolic and end-systolic volume indices (LVEDVI and LVESVI) were investigated. Twenty-two normal subjects were studied at rest and during upright submaximal exercise. RVEF was determined using a first-pass method. LVEF was measured using multiple gated blood pool imaging. During the exercise test ECGs remained normal. HR and BP increased significantly (P less than 0.01). RVEF increased from 44% +/- 4 (mean +/- SD) to 60% +/- 6 (P less than 0.001). LVEF increased from 62% +/- 6 to 76 +/- 5 (P less than 0.001). A wider scatter was observed in delta RVEF than in delta LVEF. There was a 14% increase in LVEDV-index and a 14% decrease in LVESV-index (P less than 0.001). A multiple regression analysis with delta RVEF as the dependent variable and delta HR, delta systolic BP, delta LVEF, delta LVEDV-index and LVESV-index as independent variables showed a significant correlation between delta RVEF and delta LVEF and delta systolic BP (P less than 0.05). Our data provide insight into the mechanisms by which the pump performance is increased in normal subjects. The central mechanisms observed are the Starling effect and an increase in contractility of the myocardium. This is connected in the general circulation to an increase in afterload, indicating a redistribution of blood from the vascular beds to the muscles and to the heart.

Adult↗