Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AIR CONDITIONING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Effective temperature scale useful for hypo- and hyperbaric environments.

Basic physics of man's heat exchange by radiation, convection, evaporation, and conduction through clothing is used to define and establish a Standard Effective Temperature Scale (SET), with which sensory and physiological responses of sedentary and active personnel can be related. The standard environment chosen is the Effective Temperature (ET) Scale, used by the American Society of Heating, Refrigerating and Air-Conditioning Engineers; namely, as the temperature of an isothermal enclosure at sea level with 50% rh and still air (0.1-0.15 m/s) in which a clothed (0.6 clo) sedentary subject would exchange the same total sensible and insensible heat as in the actual test environment. Mean skin temperature (Tsk) and skin wettedness (w) can be associated at sea level with thermal comfort and neutrality and with heat exchange. For hypo- and hyperbaric environments, thermal equivalence between SET and any test environment occurs when mean body temperature (Tb) for each is identical. Comprehensive data, developed for a 2-node model of human temperature regulation and of the associated partitional calorimetry, demonstrates the expected interaction between SET and the basic environmental and clothing factors over the barometric range 0.33 to 30 ATA.

Air Movements↗

Experimental study of ventilation performance and contaminant distribution of underfloor ventilation systems vs. traditional ceiling-based ventilation system.

UNLABELLED: Ventilation performance and pollutant distribution in a traditional ceiling-type ventilation system, a top-return (TR)-type and a floor-return (FR)-type underfloor ventilation systems were performed in a controlled experimental room. Tracer gas method was utilized to determine the age of air and the contaminant removal effectiveness. Tobacco smoke was also introduced to study the particle-phase pollutant distribution. The TR system delivered conditioned air more efficiently in the occupied zone and exhibited higher gaseous contaminant removal effectiveness. It also showed the lowest smoke particle concentration compared with the other two systems. The FR system showed better ventilation performance over the mixing system at the space that was close to the floor supply outlet and at the lower height level. The FR system was less effective than the TR system in removing buoyant tobacco smoke particles at the upper part of the room indicating its highly localized characteristics. Differences in experimental conditions between the present and the previous studies and their effects on the experimental results are discussed. In general, the experimental data suggested that both types of the underfloor ventilation systems have the potential of improving air quality at the breathing zone over the ceiling-based mixing system with suitable designs. PRACTICAL IMPLICATIONS: This study shows the possibility of improving indoor air quality using underfloor ventilation systems compared with the traditional ceiling-based ventilation system. However, different configurations of the underfloor ventilation system show various ventilation characteristics. The engineers should consider these features when implementing an underfloor ventilation design. The top-return (TR) configuration improves indoor air quality by creating a displacement-like flow pattern while the floor-return (FR) configuration shows highly localized ventilation characteristics. The FR configuration improved the indoor air quality at spaces near the floor diffusers and up to certain heights.

Air Pollution, Indoor↗

Nasal anatomy, physiology, and function.

The nose in man, despite its unusual external appearance, has a variety of functions that are related to its unique internal anatomy and the vascular tone of its mucous membrane. In addition, it houses the receptor side of the first cranial nerve. This receptor is relatively primitive in man and probably less effective in monitoring his environment than that of other mammals. The nose is the portal by which the ambient air first enters the body. The nose functions as a "guard dog" or "watch dog" for the lungs. It conditions air to a specific range of temperature and humidity. Its protective filtration and ciliary mechanisms are abundant. Nasal reflex functions affect the lower respiratory tract and cardiopulmonary functions and respond to intense emotional situations. Since the time of Proetz' original essays on the physiology of the nose, a great deal of study has been done on the various and myriad functions of the nose. A working understanding of its peculiar anatomy and unusual functions are important for understanding the pathophysiology of nasal disease.

Airway Resistance↗

Bilateral hyperalgesia to chemical stimulation of the nasal mucosa following unilateral inflammation.

The aim of the present study was to investigate the bilateral sensory changes to chemical noxious stimuli in the trigeminally innervated areas following unilateral nasal inflammation. Twenty healthy volunteers took part in five experiments. Intranasal inflammation was induced by means of a constant flow of cold air (145 ml/s); temperature and humidity of the airstream were varied across experiments. For the non-inflamed (NOI) condition, air temperature was 36 degrees C and its humidity 80%. In the other experiments the airstream's humidity was either 25% or 80% with a constant temperature of 20 degrees C; the airstream was applied to the left or right nostril. In order to produce noxious chemical stimuli, gaseous CO2 was applied to the left nostril (36 stimuli of 200 ms; 65% v/v CO2; interstimulus interval 30 s). Subjects rated the pain intensity of the stimuli by means of a visual analogue scale (VAS). As an indicator for hyperalgesia, the subjective pain ratings to CO2 stimuli increased not only while they were applied at the inflamed site, but also during their application contralaterally to the inflamed side. These results demonstrate the occurrence of bilateral hyperalgesia to noxious chemical stimuli in the nasal mucosa following unilateral inflammation which indicates the involvement of central changes.

Adult↗

Anoxia-hyperoxia induces monocyte-derived interleukin-8.

Ischemia-reperfusion and hyperoxia-induced pulmonary injury are associated with the presence of activated neutrophils (PMN) and cellular injury. Although the signals orchestrating the directed migration of these PMN during the pathogenesis of these disease states remain to be fully elucidated, it appears they may be dependent upon the production of certain neutrophil activating/chemotactic factors such as C5a, leukotriene B4, platelet-activating factor, and IL-8. The production of the latter chemotaxin by mononuclear phagocytes is especially intriguing as these cells can mediate inflammatory cell migration by either directly generating IL-8, or by inducing its production from surrounding nonimmune cells. In light of these observations, we propose that ischemia-reperfusion and oxidant stress, in vivo, may be simulated by anoxia-hyperoxia induced stress in vitro, and that this stress may act as a stimulus for the production of IL-8. We now show that isolated human blood monocytes respond to such an oxygen stress with augmented production of IL-8. In initial studies, monocytes demonstrated an increase in the production of IL-8 under anoxic preconditioning. Subsequently, monocytes were cultured under one of the following conditions for 24 h: (a) room air/5% CO2; (b) 95% N2/5% CO2 for 6 h, followed by room air/5% CO2 for 18 h; (c) 95% N2/5% CO2 for 6 h, followed by 95% O2/5% CO2 for 18 h; (d) room air/5% CO2 for 6 h, followed by 95% O2/5% CO2 for 18 h; or (e) 95% O2/5% CO2. Supernatants were isolated and analyzed for IL-8 antigen by specific IL-8 ELISA, demonstrating the production of monocyte-derived IL-8: 5.9 +/- 0.9, 11.4 +/- 1.7, 21.1 +/- 2.3, 14.6 +/- 2.4, and 26.3 +/- 4.7, ng/ml by designated conditions a, b, c, d, and e listed above, respectively. This variance in IL-8 production reflects altered rates of transcription as shown by Northern blot analysis and nuclear run-off assay. Furthermore, when monocytes were concomitantly treated with LPS (100 ng/ml) under in vitro hyperoxic conditions, both IL-8 steady-state mRNA and antigenic activity were two- to threefold greater than under room air conditions. The association of anoxic preconditioning and oxygen stress with augmented production of monocyte-derived IL-8 support the potential role for ischemia-reperfusion and hyperoxia-induced IL-8 production in vivo, providing a possible mechanism for PMN migration/activation in disease states characterized by altered tissue oxygenation.

Animals↗

[Importance of the relative humidity values in determining thermohygrometric comfort].

A condition of discomfort with specific symptoms, such as throat dryness, eye irritation, in a group of workers of a small, air conditioned, working department, is described. Neither the measurements of the possible environmental pollutants concentrations, nor the assessment of the usually adopted comfort indexes (PMV-PPD) justified the worker's symptoms. They completely disappeared by means of appropriate environmental improvements aiming to increase the relative humidity values from 29% to 50-55% (drop of the amount of the hygroscopic material stored, setting up of an humidifier). The effects of the low humidity values on the hygrometric and thermal comfort are finally discussed.

Air Pollutants, Occupational↗

Reduced hyperpnea-induced bronchospasm following repeated cold air challenge.

This study assessed reduction in expiratory function in 12 asthmatic subjects both after 5 min of cold air provocation (CAP) with dry air conditioned to approximately 0 degrees C and after exercise (to 85% of predicted maximum heart rate) while breathing ambient room air (approximately 21 degrees C and 40% relative humidity). These assessments were done both before and after the following training protocol. Three 5-min periods of isocapnic cold air hyperpnea separated by 5-min rest periods were performed breathing 0 degrees to -10 degrees C air, for 36 sessions over 12 wk. As expected, pretraining expiratory function was significantly reduced (P less than 0.001) after both CAP and exercise. The posttraining reduction in expiratory function after CAP and exercise, however, was significantly less pronounced (largest P less than 0.05). These data support our hypothesis that repeated bouts of cold air challenge result in airway acclimatization to cold air and consequent decrease in exercise-induced bronchospasm. Acclimatization may result directly either by habituation of the airways or by vasodilation leading to increased bronchial blood flow and consequent reduced airway cooling. An unanticipated finding, though, is that repeated cold air challenge may also cause long-term inflammatory changes in the airways. A significant percentage of subjects experienced reduced base-line pulmonary function and overall exacerbation of asthma symptoms during the training period.

Acclimatization↗

Ascorbic acid concentration in Cv. conference pears during fruit development and postharvest storage.

L-ascorbic acid (L-AA) concentration changes during the development of cv. Conference pears and the influence of postharvest handlings (gas condition, cooling rate, cooling duration) on L-AA breakdown were studied. L-AA concentration fluctuates in young fruits, remains stable during fruit maturation, and starts to decline 1 week before commercial harvest. The most rapid decrease in L-AA concentration was found during immediate controlled atmosphere. During short-term storage, only the gas condition was found to influence L-AA breakdown; no significant difference between gradually or immediately cooled pears was determined. Under air conditions, both cooling strategies did not differ from the L-AA breakdown in pears allowed to ripen on the tree up until 3 weeks after the optimal harvest date. During long-term storage, the cooling duration (1-3 weeks) had no effect whereas both O2 and CO2 had a significant effect on L-AA retention. After 7 months of storage, no difference was found in dehydroascorbic acid concentration; the L-AA and total L-AA concentrations, in contrast, were significantly lower in the 5% CO2 conditions.

Ascorbic Acid↗

Air in the minor fissure: a sign of right-sided pneumothorax.

Pneumothorax in the critically ill patient may be difficult to detect when the air does not rise to the apex of the thorax. Several radiographic signs have been previously described to help recognize this condition. Air in the minor fissure, a previously unreported radiographic finding, is an additional sign of right-sided pneumothorax.

Humans↗

A technique to measure the ability of the human nose to warm and humidify air.

To assess the ability of the nose to warm and humidify inhaled air, we developed a nasopharyngeal probe and measured the temperature and humidity of air exiting the nasal cavity. We delivered cold, dry air (19-1 degrees C, <10% relative humidity) or hot, humid air (37 degrees C, >90% relative humidity) to the nose via a nasal mask at flow rates of 5, 10, and 20 l/min. We used a water gradient across the nose (water content in nasopharynx minus water content of delivered air) to assess nasal function. We studied the characteristics of nasal air conditioning in 22 asymptomatic, seasonally allergic subjects (out of their allergy season) and 11 nonallergic normal subjects. Inhalation of hot, humid air at increasingly higher flow rates had little effect on both the relative humidity and the temperature of air in the nasopharynx. In both groups, increasing the flow of cold, dry air lowered both the temperature and the water content of the inspired air measured in the nasopharynx, although the relative humidity remained at 100%. Water gradient values obtained during cold dry air challenges on separate days showed reproducibility in both allergic and nonallergic subjects. After exposure to cold, dry air, the water gradient was significantly lower in allergic than in nonallergic subjects (1,430 +/- 45 vs. 1,718 +/- 141 mg; P = 0.02), suggesting an impairment in their ability to warm and humidify inhaled air.

Adult↗

Will turbulence stall air medicine?

Conditions in the air medical industry have improved dramatically since the first hospital-based service was founded in 1972. Will the industry continue to soar in the 1990s, or is it heading for a nose dive?

Aircraft↗

Oxygen uptake capacity of the amphibious fish - Amphipnous cuchia (Ham) (Symbranchiformes, Amphipnoidae).

The O2 uptake capacity of Amphipnous cuchia has been determined in relation to standard temperature of 25 degrees C. The measurement of O2 uptake indicates nearly 75% of the oxygen demand to be met through the air breathing organs and 25% by the skin and vestigeal gill through water in a normal habitat. The total VO2 during aerial-aquatic gas exchange is 60.5 ml/kg/hr. The prevention of surfacing resulted in a lower O2 uptake rate (38.29 ml/kg/hr). During submergence, the utilisation of air sacs for extracting O2 by regular pumping of water in and out is peculiar to the fish. Under normal respiratory conditions (air + water), the slope for O2 uptake through air is 0.72, 0.23 for water and 0.57 for both air + water. The average ratio borne by the fish for aquatic/air breathing (ml/kg/min) is higher in fishes below 60 g body weight, and aquatic respiration predominates in fishes weighing less than 6.0 g.

Animals↗

CO(2)-responsive transcriptional regulation of CAH1 encoding carbonic anhydrase is mediated by enhancer and silencer regions in Chlamydomonas reinhardtii.

Chlamydomonas reinhardtii adapts to the stress of CO(2)-limiting conditions through the induction of a set of genes including CAH1, which encodes a periplasmic carbonic anhydrase. CAH1 is up-regulated under low-CO(2) conditions (air containing 0.04% [v/v] CO(2)) in the presence of light, whereas it is down-regulated under high-CO(2) conditions (5% [v/v] CO(2)) or in the dark. In an effort to identify cis-elements involved in the transcriptional regulation of CAH1, a series of 5'-nested deletions of the region upstream of CAH1 were fused to a promoterless arylsulfatase reporter gene (ARS). The upstream region from -651 to +41 relative to the transcription start site was sufficient to regulate the expression of ARS with kinetics similar to those of endogenous CAH1. Deletion of the region between -651 and -294 resulted in a significant decrease in the level of arylsulfatase activity expressed under low-CO(2) conditions. The 543-bp upstream region from -651 to -109, without any promoter elements, CAAT-box, or TATA-box, could confer CO(2) and light responsiveness on the beta(2)-tubulin minimal promoter. This 543-bp region was divided into two parts: a 358-bp silencer region from -651 to -294, which represses the minimal promoter activity under high-CO(2) conditions, and a 185-bp enhancer region from -293 to -109, which activates the promoter under low-CO(2) conditions in the presence of light.

5' Untranslated Regions↗

Effect of CO2 inhalation on central sleep apnea and arousals from sleep.

BACKGROUND: CO(2) inhalation reduces central sleep apnea (CSA) in patients with congestive heart failure (CHF) and idiopathic CSA. CO(2) is also a stimulus for cortical arousal, which has been linked to increased sympathetic nerve activity (SNA) and increased mortality in CHF patients with CSA. OBJECTIVE: We have tested the hypothesis that during sleep, inhalation of CO(2) sufficient to reduce the apnea-hypopnea index (AHI) would not reduce the arousal index (AroI). METHODS: In 10 male patients with CSA (7 with CHF and 3 with idiopathic CSA), the inspired CO(2) concentration was increased to raise the sleeping end-tidal CO(2) by 2-4 mm Hg during established stage 2 sleep. Each intervention was maintained for a 10-min period. Sleep stage was monitored with electroencephalograms, electrooculograms, submental electromyogram, airflow with pneumotachometer and respiratory effort and blood gases with oxygen saturation and end-tidal CO(2). During periods of air and CO(2) breathing, AHI and AroI were compared with paired t tests; patients acted as their own controls. RESULTS: Inhalation of CO(2) produced a significant reduction in AHI (mean +/- SEM) from 74.4 +/- 12.4 events/h during air breathing to 25.8 +/- 7.8 events/h with CO(2) inhalation (p = 0.002). However, the AroI was not significantly different between the two conditions, air 67.8 +/- 12.3 events/h and CO(2) inhalation 52.8 +/- 12.4 events/h (p = 0.264). CONCLUSION: CO(2) inhalation reverses CSA but not arousals from sleep. Our findings highlight the need for treatment options that reduce both respiratory events and decrease arousals from sleep, with their associated SNA sequelae.

Administration, Inhalation↗

Acute sensory responses of nonsmokers at very low environmental tobacco smoke concentrations in controlled laboratory settings.

The objective of this study was to provide a basis for effectively protecting nonsmokers from acute sensory impacts and for preventing deterioration of indoor air quality caused by environmental tobacco smoke (ETS) emissions. With an olfactory experiment we determined odor detection thresholds (OT) of sidestream ETS (sETS), and with a full-body exposure experiment we investigated sensory symptoms at very low sETS exposure concentrations. OT concentrations for sETS are three and more orders of magnitude lower than ETS concentrations measured in field settings and correspond to a fresh air dilution volume of > 19,000 m(3) per cigarette, over 100 times more than had previously been suggested for acceptable indoor air conditions. Eye and nasal irritations were observed at one order of magnitude lower sETS concentrations than previously reported, corresponding to a fresh air dilution volume of > 3,000 m(3) per cigarette. These findings have great practical implications for defining indoor air quality standards in indoor compartments where ETS emissions occur. Our study strongly supports the implementation and control of smoking policies such as segregating smoking areas from areas where smoking is not permitted or instituting smoking bans in public buildings.

Adolescent↗

Response to ozone in two lettuce varieties on chlorophyll a fluorescence, photosynthetic pigments and lipid peroxidation.

The effect of different O3 concentrations on two lettuce (Lactuca sativa L.) varieties (Valladolid and Morella) was investigated through chlorophyll (Chl) a fluorescence parameters, photosynthetic pigments (Chl a, b and total carotenoid), lipid peroxidation and crop yield. Ozone fumigation caused: a decrease in maximum quantum yield of photosystem II (PSII) photochemistry (Fv/Fm) in mature leaves, a reduction in the non-cyclic electron flow (phiPSII) and a lower capacity to reoxidize the QA pool (qP). These reductions were significant in the Valladolid var. but not in the Morella var. A significant decrease in Chl a, b and in the total carotenoids was observed in the Valladolid var. but not in the Morella var. mainly under O3 fumigation conditions. We observed that the NPQ parameter did not increase in parallel to the qP reduction seen in the Valladolid var. O3 fumigation with respect to air charcoal filtered air conditions. This fact could be associated with a lower capacity for dissipation of non-radiative excess energy and it may be closely correlated with significant decreases in photosynthetic pigment concentration. A decrease in NPQ from air ozone-free to ozone fumigation in the Morella var. can be explained by the need to maintain the photochemical quenching under O3 stress. It may also be associated with a slight increase in photosynthetic pigments. The differences between the two varieties may indicate that the Valladolid var. is more susceptible to O3 damage.

Chlorophyll↗

Plasma adenosine during investigation of hypoxic ventilatory response.

Adenosine, an endogenous nucleoside, is released by hypoxic tissue, causes vasodilation, and influences ventilation. Its effects are mediated by P1-purinoceptors. We examined to what extent the plasma adenosine concentration in the peripheral venous blood correlates with hypoxic ventilatory response (HVR) and ventilatory drive P0.1 to find out whether endogenously formed adenosine has an influence on the individual ventilatory drive under hypoxic conditions. While investigating the HVR of 14 healthy subjects, the ventilatory drive P0.1 was measured with the shutter of a spirometer. Determination of the ventilatory drive P0.1(RA) started under room air conditions (21% O (2)) and then inspiratory gas was changed to a hypoxic mixture of 10% O (2) in N (2) to determine P0.1(Hyp). At the time of the P0.1 measurements, two blood samples were taken to determine the adenosine concentrations. After removal of cellular components and proteins, samples were analyzed by high-pressure liquid chromatography (HPLC). Both adenosine concentrations in plasma under room air (r = 0.59, p < 0.05) and adenosine concentrations under hypoxia (r = 0.75, p < 0.01) correlated significantly with the ventilatory drive P0.1. In addition, plasma adenosine concentrations during hypoxic conditions showed a significant correlation with HVR on the 0.01 level (r = 0.71, p < 0.01). The results indicate a possible role of endogenous adenosine in the regulation of breathing in humans. We assume that endogenous adenosine influences the HVR and the ventilatory drive, probably by modulating the carotid body chemoreceptor response to hypoxia.

Adenosine↗

Aerobiology as a tool to help in episodes of occupational allergy in work places.

Over 80% of weekday time is spent indoors and the air quality of this environment may affect the incidence of symptoms in allergy sufferers. However, indoor/outdoor measurements have been jointly considered only in a few studies. The objective of this paper is to analyse indoor/outdoor biological and non-biological particle content togeher with other factors affecting the severity of symptoms during working periods in an Aerobiology Lab during the most troublesome period of the year for allergy sufferers. For this purpose, indoor/ outdoor air samples were taken using standard portable particle traps at the National Coordinating Centre of the Spanish Aerobiology Network, University of Cordoba. The analysis differentiated between biological and non-biological material, and the allergy symptoms suffered by workers were quantified and correlated accordingly. An inventory of the incoming and outgoing sources of emissions was done in order to identify agravating co-factors. The results showed that since there was very little air movement between indoors and outdoors, there was a significant difference in the amount of biological material present in the two areas. The presence of some indoor source of emissions, such as the Plant Collections property of the Department, the Air Conditioned System and the volatile compounds of the copying machine was responsible of high particle content. External factors such as weather conditions or human activities contributed exacerbating symptoms. As Conclusion, the knowledge of airborne biological particle content could be a useful tool in minimising allergy symptoms when environmental conditions render them inevitable.

Adult↗