At least 901 records · Page 50Linked to original sources

Speciation of arsenic in water, sediment, and plants of the Moira watershed, Canada, using HPLC coupled to high resolution ICP-MS.

High-performance liquid chromatography (HPLC) coupled with high-resolution sector field ICP-MS was applied to the speciation of arsenic in environmental samples collected from the Moira watershed, Ontario, Canada. Arsenic contamination in Moira River and Moira Lake from historic gold mine operations is of increasing environmental concern to the local community. In this study, the current arsenic contamination status in water, sediment, and plants was investigated. Elevated levels of arsenic in the surface water of up to 75 ng mL(-1) in Moira River and 50 ng mL(-1) in Moira Lake were detected, 98% of which was present as arsenate. High concentrations of arsenic (>300 ng mL(-1)), mainly present as arsenite, were detected in sediment porewaters. A sediment profile of As from the West basin of Moira Lake showed lower As concentrations compared with data from the 1990s. An optimized extraction procedure using a phosphoric acid-ascorbic acid mixture demonstrated that an unknown "As-complex" which may consist of As, sulfide and organic matter is potentially responsible for the release of arsenite from the sediment to the overlying water column. Arsenic concentrations in plant samples ranged from 2.6 to 117 mg kg(-1), dry weight. Accumulation of arsenic was observed in submerged plants collected from Moira River and Moira Lake. Only a small part of the arsenic (6.3-16.1%) in the plants was extractable with methanol-water (9:1), and most of this arsenic (70-93%) was inorganic arsenic. A variety of organic arsenic compounds, including simple methylated compounds (methylarsonic acid and dimethylarsinic acid), trimethylarsine oxide, and tetramethylarsonium cation were detected at trace levels. No arsenobetaine and arsenocholine was found in any plant sample. An unknown compound, most probably an arsenosugar was detected in the two submerged plants, coontail ( Ceratophyllum demersum) and long-stemmed waterwort ( Elatine triandra). These submerged plants are constantly exposed to high arsenic concentrations in the surrounding water. Apparently, they are able to grow in this environment without invoking the same biochemical defence known from marine algae to detoxify inorganic arsenic. The detoxification mechanism of these plants remains unknown.

Journal Article↗

The potential of arsenic speciation in molluscs for environmental monitoring.

This paper reports the assessment of total arsenic and six arsenic species (As(III), As(V), MMA, DMA, AsBet, AsCol) as contaminants of mussel samples collected around the island of Sardinia and in the Gulf of Venice. The samples were analysed using cation- and anion-exchange HPLC-HG-AFS for speciation and ICP-AES for the total As determination. To ensure the robustness of the routine analytical method, the technique was validated using a candidate reference material, BCR-710, and good agreement was obtained. It was recognised that higher total arsenic concentration in mussels does not necessarily result in higher toxicity of mussel samples.

Journal Article↗

Speciation analysis of chromium by separation on a 5-palmitoyl oxine-functionalized XAD-2 resin and spectrophotometric determination with diphenylcarbazide.

The method developed in this work for the separation and preconcentration of Cr(III) is based on its retention by an Amberlite XAD-2 copolymer resin functionalized with 5-palmitoyl-8-hydroxyquinoline (oxine), abbreviated XAD-POx, with the ligand covalently bound to the copolymer. Cr(III) sorption was quantitative within the pH range 4.5-7.0 and Cr(VI) was not retained. The Cr(III) held by the resin column was eluted with a hot solution of H(2)O(2) in pH>or=9.0 aqueous NH(3)-NH(4)Cl buffer, and Cr oxidized to CrO(4)(2-) was rejected by the chelating cation-exchanger column. Any Cr(VI) originally present with Cr(III) could be reduced with an acidic solution of H(2)O(2), and retained by the column yielding total Cr results, Cr(VI) being determined from the difference. The resin showed a maximal preconcentration factor of 60 for Cr(III), the LOD and LOQ being 9.3 and 30.1 nmol L(-1), respectively. The developed preconcentration-speciation analysis was finished with a diphenylcarbazide (DPC) spectrophotometric procedure suitable for conventional laboratories. The resin showed excellent salt tolerance, enabling Cr analysis in seawater, and was stable over extended use. All the interferents of this procedure that normally occur in an electroplating effluent, a blended coal CRM, and a standard steel sample could be removed by the recommended procedure, by use of partial and total selectivity at the adsorption and desorption stages, respectively, enabling preconcentration and colorimetric determination of chromium in various complex matrices.

Journal Article↗

Rapid speciation of Se(IV) and Se(VI) by flow injection-capillary electrophoresis system with contactless conductivity detection.

A flow injection-capillary electrophoresis system with contactless conductivity detection and hydrostatic-pressure-generated flow was used for the fast and sensitive speciation of Se(IV) and Se(VI). The sample throughput was 25 samples per hour using a background electrolyte solution containing 8.75 mM L-histidine (His) adjusted to pH 4.00 with acetic acid. The repeatability of peak areas (n=8) was better than 1.41% and the limits of detection were 190 microg L(-1) and 7.5 microg L(-1) for Se(IV) and Se(VI), respectively. The interference from carbonate, typically present in water samples, was eliminated by using a low-pH electrolyte in which carbonate is uncharged and migrates at the EOF front. The method was applied to the analysis of Se(IV) and Se(VI) in soil samples that were spiked with both selenium species and the results for recovery of both selenium species were in good agreement with their introduced concentrations.

Journal Article↗

Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method?

This critical review discusses the conditions under which inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) is suitable as a routine method for trace element and element-speciation analysis. It can, in general, be concluded that ICP-IDMS has high potential for routine analysis of trace elements if the accuracy of results is of predominant analytical importance. Hyphenated techniques with ICP-IDMS suffer both from lack of commercially available isotope-labeled spike compounds for species-specific isotope dilution and from the more complicated system set-up required for species-unspecific ICP-IDMS analysis. Coupling of gas or liquid chromatography with species-specific ICP-IDMS, however, enables validation of analytical methods involving species transformations which cannot easily be performed by other methods. The potential and limitations of ICP-IDMS are demonstrated by recently published results and by some unpublished investigations by our group. It has been shown that possible loss of silicon as volatile SiF4 during decomposition of a sample by use of hydrofluoric acid has no effect on trace silicon determination if the isotope-dilution step occurs during digestion in a closed system. For powder samples, laser ablation ICP-IDMS can be applied with an accuracy comparable with that only available from matrix-matched standardization, whereas the accuracy of electrothermal vaporization ICP-IDMS was strongly dependent on the element determined. The significance of easy synthesis of isotope-labeled spike compounds for species-specific ICP-IDMS is demonstrated for monomethylmercury and Cr(VI). Isotope-exchange reactions between different element species can prevent the successful application of ICP-IDMS, as is shown for iodinated hydrocarbons. It is also shown for monomethylmercury that species transformations during sample-pretreatment steps can be followed by species-specific ICP-IDMS without loss of accuracy. A relatively simple and time-efficient procedure for determination of monomethylmercury in environmental and biological samples is discussed. The method, which entails a rapid microwave-assisted isotope dilution step and in-situ extraction of the derivatized species, has good potential for routine application in the future.

Journal Article↗

Speciation studies by capillary electrophoresis - simultaneous determination of iodide and iodate in seawater.

A capillary electrophoresis (CE) method was developed for the simple and highly-sensitive determination of iodine species in seawater. The proposed method is based on the on-capillary preconcentration of iodide and iodate using the principle of transient isotachophoresis (tITP) stacking, and direct UV detection of the separated species at 226 and 210 nm, respectively. The preconcentration procedure takes advantage of the electrokinetic introduction of the terminating ion [2-( N-morpholino)ethanesulfonate (MES)] into the capillary, that enables a longer tITP state. The appropriate conditions for the tITP step were optimized by varying the MES and sample injection time and the concentration of cetyltrimethylammonium chloride (CTAC). The latter component of the separation electrolyte (SE) was shown to strongly affect the migration and therefore the enrichment of iodide due to specific ion-association. The optimized separations were performed in 12.5 mM CTAC, 0.5 M NaCl (pH 2.4). Valid calibration is demonstrated in the range 3-60 microg x L(-1) iodide ( R=0.9992) and 40-800 microg x L(-1) iodate ( R=0.9994). The detection limits achieved were 0.23 microg x L(-1) (2 nM) for iodide and 10 microg x L(-1) (57 nM) for iodate. Such sensitivity and linearity thresholds allowed the reported tITP-CE system to be applied to direct speciation analysis of surface and seabed seawater. The comparison of CE results with those of an ion-chromatography (IC) technique proved that the method has acceptable accuracy.

Journal Article↗

Novel separation method for highly sensitive speciation of cancerostatic platinum compounds by HPLC-ICP-MS.

A high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) method is presented for analysis of cisplatin, monoaquacisplatin, diaquacisplatin, carboplatin, and oxaliplatin in biological and environmental samples. Chromatographic separation was achieved on pentafluorophenylpropyl-functionalized silica gel. For cisplatin, carboplatin, and oxaliplatin limits of detection of 0.09, 0.10, and 0.15 microg L(-1), respectively, were calculated at m/z 194, using aqueous standard solutions. (3 microL injection volume). The method was utilized for model experiments studying the stability of carboplatin and oxaliplatin at different chloride concentrations simulating wastewater and surface water conditions. It was found that a high fraction of carboplatin is stable in ultrapure water and in solutions containing 1.5 mol L(-1) Cl-, whereas oxaliplatin degradation was increased by increasing the chloride concentration. In order to support the assessment of oxaliplatin eco-toxicology, the method was tested for speciation of patient urine. The urine sample contained more than 17 different reaction products, which demonstrates the extensive biotransformation of the compound. In a second step of the study the method was successfully evaluated for monitoring cancerostatic platinum compounds in hospital waste water.

Antineoplastic Agents↗

Simultaneous speciation of mercury and butyltin compounds in natural waters and snow by propylation and species-specific isotope dilution mass spectrometry analysis.

A robust method has been developed for simultaneous determination of mercury and butyltin compounds in aqueous samples. This method is capable of providing accurate results for analyte concentrations in the picogram per liter to nanogram per liter range. The simultaneous determination of the mercury and tin compounds is achieved by species-specific isotope dilution, derivatization, and gas chromatography-inductively coupled plasma mass spectrometer (GC-ICP-MS). In derivatization by ethylation and propylation, reaction conditions such as pH and the effect of chloride were carefully studied. Ethylation was found to be more sensitive to matrix effects, especially for mercury compounds. Propylation was thus the preferred derivatization method for simultaneous determination of organomercury and organotin compounds in environmental samples. The analytical method is highly accurate and precise, with RSD values of 1 and 3% for analyte concentrations in the picogram per liter to nanogram per liter range. By use of cleaning procedures and SIDMS blank measurements, detection limits in the range 10-60 pg L(-1) were achieved; these are suitable for determination of background levels of these contaminants in environmental samples. This was demonstrated by using the method for analysis of real snow and seawater samples. This work illustrates the great advantage of species-specific isotope dilution for the validation of an analytical speciation method-the possibility of overcoming species transformations and non-quantitative recovery. Analysis time is saved by use of the simultaneous method, because of the use of a single sample-preparation procedure and one analysis.

Hydrogen-Ion Concentration↗

Speciation analysis of calcium, iron, and zinc in casein phosphopeptide fractions from toddler milk-based formula by anion exchange and reversed-phase high-performance liquid chromatography-mass spectrometry/flame atomic-absorption spectroscopy.

Casein phosphopeptides (CPP) are phosphorylated casein-derived peptides that can be released by in-vitro or in-vivo enzymatic hydrolysis of alpha(s1)-casein, alpha(s2)-casein, and beta-casein (CN). Many of these peptides contain a highly polar acidic sequence of three phosphoseryl groups followed by two glutamic acid residues. These domains are binding sites for minerals such as calcium, iron, and zinc and play an important role in mineral bioavailability. The aim of this study was speciation analysis of calcium, iron, and zinc in CPP fractions from the soluble fraction of a toddler milk-based formula. Methods for CPP separation by anion-exchange high-performance liquid chromatography (AE-HPLC) were combined with CPP identification by reversed-phase high performance liquid chromatography-electrospray ionization mass spectrometry and determination of the calcium, iron, zinc, and phosphorus content of the fractions obtained by AE-HPLC. Calcium and phosphorus were detected in all the analyzed AE-HPLC fractions. Calcium and zinc could be bound to CPP derived from alpha(s1)-CN and alpha(s2)-CN in fraction 3. Iron could be bound to CPP in fraction 4 in which beta-CN(15-34)4P was present with the cluster sequence S(P)S(P)S(P)EE. The results obtained prove the different distribution of calcium, iron, and zinc in heterogeneous CPP fractions.

Amino Acid Sequence↗

Development of an on-line UV decomposition system for direct coupling of liquid chromatography to atomic-fluorescence spectrometry for selenium speciation analysis.

Speciation analysis of four selenium species (selenite, selenate, selenocystine, and selenomethionine) has been performed by on-line coupling of liquid chromatography (LC), UV decomposition, hydride generation (HG), and atomic-fluorescence spectrometry (AFS). Because only selenite (Se(IV)) can generate hydrides, on-line conversion of organic and inorganic selenium species is discussed. Preliminary study showed that the use of only UV light was not sufficient to reduce selenate, because no absorption is observed for this compound at the main wavelength of the low-pressure mercury lamp (253.7 nm). Thus, new conditions based on addition of a reducing reagent (I-) were developed. Mechanisms of action are proposed to explain selenium species conversions. Because of their compatibility with on-line treatment, phosphate buffers were used for chromatographic separation on an anion exchange column (Hamilton PRP-X100). Detection limits (19-60 pg Se) and repeatability of the technique were close to those obtained by conventional quadrupole ICPMS. Applications to real samples such as water and oysters are presented and emphasize the robustness of the system.

Journal Article↗

Liquid chromatography-mass spectrometry (LC-MS): a powerful combination for selenium speciation in garlic (Allium sativum).

Liquid chromatography (LC) hyphenated with both elemental and molecular mass spectrometry has been used for Se speciation in Se-enriched garlic. Different species were separated by ion-pair liquid chromatography-inductively coupled plasma mass spectrometry (LC-ICP-MS) after hot-water extraction. They were identified by on-line reversed-phase liquid chromatography-electrospray ionization tandem mass spectrometry (RPLC-ESI-MS-MS). Se-methionine and Se-methylselenocysteine were determined by monitoring their product ions. Another compound, gamma-glutamyl-Se-methylselenocysteine, shown to be the most abundant form of Se in the garlic, was determined without any additional sample pre-treatment after extraction and without the need for a synthesized standard. Product ions for this dipeptide were detected by LC-ESI-MS-MS for three isotopes of Se-78 Se, 80Se: and 82Se. The method was extended to the species extracted during in-vitro gastrointestinal digestion. Because both Se-methylselenocysteine and gamma-glutamyl-Se-methylselenocysteine have anticarcinogenic properties, their extractability and stability during human digestion are very important. Garlic was also treated with saliva, to enable detection and analysis of species extracted during mastication. Detailed information on the extractability of selenium species by both simulated gastric and intestinal fluid are given, and variation of the distribution of Se among the different species with time is discussed. Although the main species in garlic is the dipeptide gamma-glutamyl-Se-methylselenocysteine, Se-methylselenocysteine is the main compound present in the extracts after treatment with gastrointestinal fluids. Two more, so far unknown compounds were observed in the chromatogram. The extracted species and their transformations were analysed by combining LC-ICP-MS and LC-ESI-MS-MS. In both the simulated gastric and intestinal digests, Se-methionine, Se-methylselenocysteine, and gamma-glutamyl-Se-methylselenocysteine could be determined by LC-ESI-MS-MS by measuring their typical product ions.

Chromatography, Liquid↗

Extraction procedures for chemical speciation of arsenic in atmospheric total suspended particles.

An arsenic chemical speciation study was performed in 2000, using air filters on which total suspended particles (TSP) were collected, from the city of Huelva, a medium size city with huge industrial influence in SW Spain. Different procedures for extraction of the arsenic species were performed using water, NH2OH.HCl, and H3PO4 solutions, with either microwave or ultrasonic radiation. The best optimised extraction methods were use of 100 mmol L(-1) NH2OH.HCl and 10 mmol L(-1) H3PO4 and microwave radiation for 4 min. High-performance liquid chromatography coupled with hydride generation and atomic fluorescence spectrometry (HPLC-HG-AFS) was employed for determination of the arsenic species. The results from 12 TSP air filters collected on a monthly basis showed extraction was quantitative (94% with NH2OH.HCl and 86% H3PO4). Only inorganic arsenic species (arsenite and arsenate) were detected. The mean arsenite concentration was 1.2+/-0.3 ng m(-3) (minimum 0.3 ng m(-3), maximum 1.8 ng m(-3)). The mean arsenate concentration was 10.4+/-1.8 ng m(-3), with greater monthly variations than arsenite (minimum 2.1 ng m(-3), maximum 30.6 ng m(-3)). The high level of arsenic species in the TSP samples can be related to a copper smelter located in the region.

Air Pollutants↗

Effect of the interface on separation in multicapillary gas chromatography-based hyphenated techniques for speciation analysis of organometallic compounds.

This paper reports the effect of transfer line (TL) internal diameter (i.d.) on gas chromatographic separation characteristics such as efficiency and speed, when a multicapillary (MC) column is used for speciation analysis of mercury. Five different TL consisting of fused-silica capillaries with 0.15, 0.20, 0.25, 0.32, and 0.53 mm i.d. are compared. The separation efficiency and total chromatographic run time are critically affected by the i.d. of the TL. Narrow capillaries (i.d.< or =0.20 mm) produce minimum peak dispersion whereas wide capillaries result in narrow peaks and shorter chromatographic analysis times. A thermodynamic approach is proposed to describe the motion of the analytes through the separation column and TL. The model provides good agreement with the experimental data for high pressures (> or =35 psig) and wide TL (> or =0.25 mm i.d.).

Chromatography, Gas↗

Arsenic speciation in xylem sap of cucumber (Cucumis sativus L.).

Flow injection analysis (FIA) and high-performance liquid chromatography double-focusing sector field inductively coupled plasma mass spectrometry (HPLC-DF-ICP-MS) were used for total arsenic determination and arsenic speciation of xylem sap of cucumber plants (Cucumis sativus L.) grown in hydroponics containing 2 micromol dm(-3) arsenate or arsenite, respectively. Arsenite [As(III)], arsenate [As(V)] and dimethylarsinic acid (DMA) were identified in the sap of the plants. Arsenite was the predominant arsenic species in the xylem saps regardless of the type of arsenic treatment, and the following concentration order was determined: As(III) > As(V) > DMA. The amount of total As, calculated taking into consideration the mass of xylem sap collected, was almost equal for both treatments. Arsenite was taken up more easily by cucumber than arsenate. Partial oxidation of arsenite to arsenate (<10% in 48 h) was observed in the case of arsenite-containing nutrient solutions, which may explain the detection of arsenate in the saps of plants treated with arsenite.

Arsenates↗

Development of a rapid extraction procedure for speciation of arsenic in chicken meat.

A rapid extraction procedure has been developed for speciation of arsenic in chicken tissue. Water, methanol-water (1:1), and methanol-chloroform (1:1) were tested as extraction media. Individual use of an ultrasonic bath, a microwave oven, or an ultrasonic probe was not sufficient for quantitative recovery of As(III), dimethylarsinate, monomethylarsonate, As(V), and arsenobetaine in spiked samples of chicken tissue. A new extraction procedure using a methanol-water mixture and a microwave oven then an ultrasonic probe enabled extraction of the arsenic species in 7 min with efficiencies ranging from 80 to 100%. HPLC-UV-HG-AFS was used for the determinations. The extraction procedure was 100% efficient when applied to real samples of chicken tissue. AsB (48+/-5 microg As kg (-1)) and one containing-arsenic feed additive, Nitarsone (227+/-5 microg As kg (-1)) were detected.

Animals↗

Evaluation of a pulsed glow discharge time-of-flight mass spectrometer as a detector for gas chromatography and the influence of the glow discharge source parameters on the information volume in chemical speciation analysis.

The figures of merit of a pulsed glow discharge time-of-flight mass spectrometer (GD-TOFMS) as a detector for gas chromatography (GC) analysis were evaluated. The mass resolution for the GD-TOFMS was determined on FWHM in the high mass range (208Pb+) as high as 5,500. Precision of 400 subsequent analyses was calculated on 63Cu+ to be better than 1% RSD with no significant drift over the time of the analysis. Isotope precision based on the 63Cu+/65Cu+ ratio over 400 analyses was 1.5% RSD. The limits of detection for gaseous analytes (toluene in methanol as solvent) were determined to be as low as several hundred ppb or several hundred pg absolute without using any pre-concentration technique. Furthermore, the different GD source parameters like capillary distance, cathode-anode spacing, and GD source pressure with regards to the accessible elemental, structural, and molecular information were evaluated. It was demonstrated that each of these parameters has severe influence on the ratio of elemental, structural, and parent molecular information in chemical speciation analysis.

Journal Article↗

Speciation of phytate ion in aqueous solution. Cadmium(II) interactions in aqueous NaCl at different ionic strengths.

Interactions between myo-inositol 1,2,3,4,5,6-hexakis(dihydrogen phosphate) (phytic acid) and cadmium(II) were studied by using potentiometry (at 25 degrees C with the ISE-H+ glass electrode) in different metal to ligand (Phy) ratios (1:1< or =Cd(2+):Phy< or =4:1) in NaCl(aq) at different ionic strengths (0.1< or =I/mol L(-1)< or =1). Nine Cd(i)H(j)Phy((12-2i-j)-) species are formed with i=1 and 2 and 4< or =j< or =7; and trinuclear Cd3H4Phy2-. Dependence of complex formation constants on ionic strength was modeled by using Specific ion Interaction Theory (SIT) equations. Phytate and cadmium speciation are also dependent on the metal to ligand ratio. Stability of Cd(i)H(j)Phy((12-2i-j)-) species was modeled as a function of both the ligand protonation step (j) and the number of metal cations bound to phytate (i), and relationships found were used for the prediction of species other than those experimentally determined (mainly di- and tri-protonated complexes), allowing the possibility of modeling Phy and Cd(II) behavior in natural waters and biological fluids. A critical evaluation of phytate sequestering ability toward cadmium(II) has been made under several experimental conditions, and the determination of an empirical parameter has been proposed for an objective "quantification" of this ability. A thorough analysis of literature data on phytate-cadmium(II) complexes has been performed.

Cadmium↗

Kinetic speciation of nickel in mining and municipal effluents.

This study presents the results of kinetic speciation of nickel in undiluted mining and municipal effluents and effluents diluted with receiving freshwaters from the surrounding environment. The dilution ratios used for the dilution of the effluents were arbitrarily chosen, but were representative of the prevailing mining practices. The purpose of the this dilution was to mimic dilution with natural waters that result from dilution of the mining and municipal effluents with receiving freshwaters, so that this study would reveal environmental realities that are of concern to the managers and regulators of water resources. Ligand exchange kinetics using the competing ligand exchange method (CLEM) was studied using two independent techniques: graphite furnace atomic absorption spectrometry (GFAAS) with Chelex 100 resin as the competing ligand, and adsorptive cathodic stripping voltammetry (AdCSV) with dimethylglyoxime (DMG) as the competing ligand to determine the percentage of Ni metal released from Ni(II)-DOC complexes and the rate of dissociation of Ni(II)-DOC complexes. Using a sample containing a mixture of 30% Copper Cliff Mine effluent, 40% Sudbury municipal effluent and 30% Vermillion River water, both techniques gave results showing that the dilution of the effluent samples increased the percentage of nickel released from Ni(II)-DOC complexes. This increase in the release of nickel from the Ni(II)-DOC complexes may be of concern to managers and regulators of water resources. Agreement between the results of these two techniques has enhanced the validity of the competing ligand exchange method used by both techniques.

Journal Article↗