Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Thermometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Patterns of thermal deposition in the skull during transcranial focused ultrasound surgery.

The induction of temperature elevation by focused ultrasound is a noninvasive surgical technique for destroying tissue. This technique has been used clinically in soft tissues such as liver, prostate and breast. It has long been desired to extend this technique to noninvasive treatment of brain tumors. Although the skull was once thought to be an unsurpassable barrier to focused ultrasound treatment, it has been shown that the distortion caused by the skull can be corrected to produce a useful intracranial focus. However, the attenuation experienced by the ultrasound in passing through cranial bone is large, and consequently the skull is subject to the deposition of acoustic energy as heat. The nature and extent of this heating process has been difficult to characterize empirically. It is practically difficult to implant a sufficient number of thermocouples to obtain detailed temperature data directly, and bone is an unsuitable medium in which to perform noninvasive thermometry using proton chemical shift magnetic resonance imaging. Furthermore, skull specimens used experimentally lack active blood perfusion of the skull and the overlying scalp. This paper describes the use of large-scale acoustic and thermal simulations to calculate the distribution of temperature within the skull and brain that can be expected to occur during therapeutically useful focused ultrasound sonications of the brain. The results demonstrate that standing waves may be formed within the skull during transcranial sonication leading to nonuniform skull heating. However, the results also show that these effects can be sufficiently controlled to allow therapeutic ultrasound to be focused in the cranial base region of the brain without causing thermal damage to the scalp, skull or outer surface of the brain.

Body Temperature↗

MRI-guided focused ultrasound: methodology and applications.

Focused ultrasound is very well suited for inducing noninvasive local hyperthermia. Since magnetic resonance imaging (MRI) may be employed to obtain real-time temperature maps noninvasively the combination of these two technologies offers great advantages specifically aimed toward oncological studies. Real-time identification of the target region and accurate control of the temperature evolution during the treatment has now become possible. Thermal ablation of pathological tissue, local drug delivery using thermosensitive micro-carriers and controlled transgene expression using thermosensitive promoters have recently been demonstrated with this unique technology. Based on these experiments combined focused ultrasound and MRI thermometry holds promise for future oncological diagnostics and treatment. In this paper, we review some of the recent methodological developments as well as experimental and first clinical studies using this approach.

Clinical Trials as Topic↗

Temperament, tympanum, and temperature: four provisional studies of the biobehavioral correlates of tympanic membrane temperature asymmetries.

Previous research in both humans and nonhuman primates suggests that subtle asymmetries in tympanic membrane (TM) temperatures may be related to aspects of cognition and socioaffective behavior. Such associations could plausibly reflect lateralities in cerebral blood flow that support side-to-side differences in regional cortical activation. Asymmetries in activation of the left and right frontal cortex, for example, are correlates of temperamental differences in child behavior and markers of risk status for affective and anxiety disorders. Tympanic membrane temperatures might thus reflect the neural asymmetries that subserve individual differences in temperament and behavior. This report merged findings from four geographically and demographically distinctive studies, which utilized identical thermometry methods to examine associations between TM temperature asymmetries and biobehavioral attributes of 4- to 8-year-old children (N = 468). The four studies produced shared patterns of associations that linked TM temperature lateralities to individual differences in behavior and socioaffective difficulties. Warmer left TMs were associated with "surgent," affectively positive behaviors, whereas warmer right TMs were related to problematic, affectively negative behaviors. Taken together, these findings suggest that asymmetries in TM temperatures could be associated with behavior problems that signal risk for developmental psychopathology.

Body Temperature↗

Changes in skin thermal clearance during anaesthesia.

Thermal and vascular side effects occurring during general anaesthesia are related to skin blood flow. A new, noninvasive probe which measures skin thermal clearance, a variable closely related to skin blood flow, was used in nine patients under phenoperidine, droperidol, propanidid anaesthesia. Statistically significant increases in skin thermal clearance clearly preceded the drop in mean arterial blood pressure and the rise in skin temperature. It is concluded that general anaesthesia induced an early increase in skin blood flow and that thermal clearance is a better technique than skin thermometry to monitor skin blood flow.

Adult↗

The Cyclops 33 radiation thermometer. An appraisal for use in anaesthesia.

The Cyclops 33 is a portable infrared radiation thermometer. It has many potential advantages over existing thermometers in anaesthetic practice. The technical details are described and the benefits over other instruments discussed. This apparatus offers considerable scope for advance in the field of thermometry in anaesthesia.

Anesthesiology↗

Irritant reactions to dithranol in normal subjects and psoriatic patients.

The irritant reaction to dithranol on normal forearm skin of forty psoriatics and forty controls was investigated by skin contact thermometry and ID50 values were calculated for each skin type (I to IV). We concluded that there is no difference between the irritant effects of dithranol in psoriatics and normal subjects. There was no correlation between irritant dose threshold and minimal erythema dose (MED) to ultraviolet radiation (UVR) but skin type I patients are the most sensitive. The irritant response to dithranol can be partially blocked by prior treatment with indomethacin.

Anthracenes↗

Effect of toothbrush stimulation on temperature of gingival and alveolar mucosae.

Thermometry was used to study the effect of applying a toothbrush to three types of oral mucosae, in forty dental students. Brushing with an electric tooth brush resulted in an immediate fall in temperature, but 3 min later the temperature was significantly higher than before stimulation. The temperature changes were greater in gingival crevice and attached gingiva compared with alveolar mucosa. Moreover, it was found that a static application of the toothbrush produced temperature changes which were equal to those following a dynamic application.

Adult↗

Pupillary reflex dilation and skin temperature to assess sensory level during combined general and caudal anesthesia in children.

BACKGROUND: Regional anesthesia causes sympathetic blockade, vasodilation and higher skin temperature in anesthetized dermatomes. Measurement of skin temperature changes might provide a useful estimate of the level of caudal anesthesia in children. Pupillary reflex dilation (PRD) allows estimation of the sensory level during combined general/epidural anesthesia in adults, but has not been assessed in children. This study was designed to evaluate skin temperature and PRD as methods of estimating sensory level in children receiving combined general/caudal epidural anesthesia. METHODS: Twenty ASA I and II children aged 10 months-5 years were enrolled. Anesthesia was induced with sevoflurane and N2O in O2 and maintained with 1 MAC isoflurane and air in O2. Caudal epidural anesthesia was achieved by injection of 1 ml x kg(-1) 0.25% bupivacaine. Skin temperature was measured by rapid response infrared thermometry. PRD was measured using an ophthalmic ultrasound biomicroscope (UBM). The three criteria used to estimate sensory level were a drop in skin temperature of 0.5 degrees C between dermatomes, PRD of 50% and PRD of 0.2 mm. RESULTS: A drop in skin temperature of 0.5 degrees C between dermatomes allowed estimation of the sensory level in only 20% of patients. PRD of 50%, and PRD of 0.2 mm allowed estimation of the sensory level in 45 and 100% of patients, respectively. PRD was significantly greater above the T10 dermatome compared with L2 (P < 0.01). The maximum pupillary dilation was significantly greater in children over 2 years of age [1.3 +/- 0.8 mm sd)] compared with children less than two years of age [0.6 +/- 0.3 mm sd)]. CONCLUSIONS: Skin temperature cannot be used to estimate sensory level during combined general/caudal epidural anesthesia. PRD of 0.2 mm is sensitive to the loss of analgesia but is not clinically useful. PRD may be useful above 2 years of age.

Analysis of Variance↗

Cerumen occlusion lowers infrared tympanic membrane temperature measurement.

OBJECTIVE: To examine the effect that cerumen occlusion of the ear canal has on infrared tympanic membrane temperature measurement. METHODS: A prospective, randomized, single-blind human study was carried out in a university hospital observation unit. The subjects were a convenience sample of human volunteers ages 18 years or older who did not have cerumen occlusion or scarred tympanic membranes. A paraffin-coated human cerumen plug was placed in one randomly chosen ear, and after 20 minutes of equilibration the temperature of each ear was measured with an infrared thermometer. Analysis of the difference in mean temperature between the occluded and nonoccluded ears was by Student's paired t-test. RESULTS: Infrared tympanic membrane temperatures were measured in 43 subjects aged 21 to 58 years. The mean temperature of the occluded ear canal was 0.3 degrees C lower than that of the opposite ear canal (p = 0.0001, 95% CI 0.16-0.45 degrees C). CONCLUSION: Cerumen occlusion of the ear canal causes underestimation of body temperature measure by infrared tympanic membrane thermometry.

Adult↗

Temperature and flow visualization in a simulation of the Czochralski process using temperature-sensitive liquid crystals.

There is no doubt today that thermal and thermocapillary convection play a dominant role in momentum, heat, and mass transfer in the Czochralski crystal growth method. Because of the complexity of the problems, measurements in one point of the volume are not sufficient to illuminate the flow topography or to compare the experimental results with real or numerically simulated data. Therefore, it is of great interest to measure the temperatures and velocities in the whole field in order to qualitatively analyze thermally driven convection. The new experimental particle image thermometry method, based on computer-aided color analysis of the TLCs reported here, enables the simultaneous determination of the temperature and velocity fields.

Computer Simulation↗

First in-vivo trials of a fiber Bragg grating based temperature profiling system.

We describe the results of in-vivo trials of a portable fiber Bragg grating based temperature profile monitoring system. The probe incorporates five Bragg gratings along a single fiber and prevents the gratings from being strained. Illumination is provided by a superluminescent diode, and a miniature CCD based spectrometer is used for demultiplexing. The CCD signal is read into a portable computer through a small A/D interface; the computer then calculates the positions of the center wavelengths of the Bragg gratings, providing a resolution of 0.2 degree C. Tests were carried out on rabbits undergoing hyperthermia treatment of the kidney and liver via inductive heating of metallic implants and comparison was made with a commercial Fluoroptic thermometry system.

Animals↗

Focal beam distortion and treatment planning in abdominal focused ultrasound surgery.

Recent clinical trials show promising results in using MRI and MRI-based thermometry to guide focused ultrasound surgery to treat uterine fibroids. During treatment, large variation in the focal temperature distribution has been observed. It is possible that some of this variation is due to abdominal tissue inhomogeneity, which might be causing focal beam distortion, and might largely decrease the focusing ability in deep-seated tissues. The purpose of this study was to numerically demonstrate this effect and also show the feasibility of restoring the focal beam patterns by employing the phase correction procedure for phased arrays. Abdominal MR data from four uterine fibroid patients were obtained to reconstruct the three-dimensional meshes of interfaces used in simulations, and one patient was selected to perform the analysis of key parameters in focused ultrasound surgery. Results show that, without phase correction, the focused beam can be severely distorted while using a frequency above 1 MHz or delivering ring-shape focal patterns. Different focal positions at the same depth may require a different power to induce the same ultrasonic intensity level (up to 179% among the different focal patterns). After adding a phase correction procedure, the distorted focal beams can be restored, and the peak intensity can be largely recovered (up to 85% among the different focal patterns). This study may offer important implications and information for treatment planning toward optimizing focused ultrasound surgery in uterine fibroid or other abdominal tumor treatments.

Abdomen↗

Treatment delivery software for a new clinical grade ultrasound system for thermoradiotherapy.

A detailed description of a clinical grade Scanning Ultrasound Reflector Linear Array System (SURLAS) applicator was given in a previous paper [Med. Phys. 32, 230-240 (2005)]. In this paper we concentrate on the design, development, and testing of the personal computer (PC) based treatment delivery software that runs the therapy system. The SURLAS requires the coordinated interaction between the therapy applicator and several peripheral devices for its proper and safe operation. One of the most important tasks was the coordination of the input power sequences for the elements of two parallel opposed ultrasound arrays (eight 1.5 cm x 2 cm elements/array, array 1 and 2 operate at 1.9 and 4.9 MHz, respectively) in coordination with the position of a dual-face scanning acoustic reflector. To achieve this, the treatment delivery software can divide the applicator's treatment window in up to 64 sectors (minimum size of 2 cm x 2 cm), and control the power to each sector independently by adjusting the power output levels from the channels of a 16-channel radio-frequency generator. The software coordinates the generator outputs with the position of the reflector as it scans back and forth between the arrays. Individual sector control and dual frequency operation allows the SURLAS to adjust power deposition in three dimensions to superficial targets coupled to its treatment window. The treatment delivery software also monitors and logs several parameters such as temperatures acquired using a 16-channel thermocouple thermometry unit. Safety (in particular to patients) was the paramount concern and design criterion. Failure mode and effects analysis (FMEA) was applied to the applicator as well as to the entire therapy system in order to identify safety issues and rank their relative importance. This analysis led to the implementation of several safety mechanisms and a software structure where each device communicates with the controlling PC independently of the others. In case of a malfunction in any part of the system or a violation of a user-defined safety criterion based on temperature readings, the software terminates treatment immediately and the user is notified. The software development process consisting of problem analysis, design, implementation, and testing is presented in this paper. Once the software was finished and integrated with the hardware, the therapy system was extensively tested. Results demonstrated that the software operates the SURLAS as intended with minimum risk to future patients.

Algorithms↗

Correction of microwave-induced thermistor sensor errors.

Accurate and reliable thermometry is essential in the development of microwave-induced hyperthermal cancer therapy. While temperature measurements in strong electromagnetic fields usually require special sensors, this does not hold true for interstitial radiator/sensor systems. Miniature thermistors (with metallic leads) bonded to invasive microwave applicators exhibit a sensor error linearly related to the radiator's transmitted power. This relationship permits thermistor sensor error correction and temperature measurements to within +/- 0.1 degrees C or better. The instrumental methods and empirical validation are presented.

Animals↗

Perturbation of the temperature distribution in microwave irradiated tissue due to the presence of metallic thermometers.

To date, satisfactory thermal dosimetry during the clinical application of localized hyperthermia can only be achieved using invasive thermometry. However the presence of commonly used metallic thermometers, such as thermocouples, may lead to the distortion of the temperature field due to self-heating of the probe under microwave irradiation. A computer simulation of the effect of this self-heating on the steady-state temperature distribution in plane-microwave irradiated homogeneous tissue has been undertaken and the significance of the effect for clinical hyperthermia dosimetry is assessed. The results indicate that a distortion of the temperature field in the neighborhood of the thermometer by several degrees can occur under adverse conditions.

Body Temperature↗

Aperture size to therapeutic volume relation for a multielement ultrasound system: determination of applicator adequacy for superficial hyperthermia.

Three-dimensional acoustic and thermal models were developed to simulate superficial hyperthermia treatments using a new multielement planar ultrasonic system. Typical power density and steady-state temperature distributions are presented. A parametric study was performed to determine the relationship between therapeutic volume (volume at and above 42 degrees C) and aperture size (number of active elements). The parameters investigated were: maximum allowable temperature, skin surface temperature, blood perfusion (thermal diffusion length), acoustic absorption, and frequency. Results showed that this device produces well distributed sound beams with lateral dimensions comparable to the aperture size. These simulated results were in agreement with experimental measurements. The simulated temperature distributions were uniform at each depth across the applicator's aperture. The main heating characteristics found were: (1) the therapeutic volume was directly proportional to the aperture size; (2) the lateral dimensions of the therapeutic volume were independent of the parameters studied and remained practically constant with depth for several centimeters, with a very rapid increase near the skin surface and a very rapid fall off at depth; and (3) therapeutic penetration was strongly dependent on maximum allowable temperature, frequency, and acoustic absorption; and weakly dependent on blood perfusion and skin surface temperature. These heating characteristics are new in commercial systems for superficial hyperthermia. Despite the well-distributed beams, it was found that in order to produce adequate hyperthermia with this device the lateral dimensions of tumors must be smaller than the applicator's active aperture and that thermal depth coverage must be monitored during treatments. Guidelines for aperture selection and thermometry strategies are discussed.

Acoustics↗

Long range source localization from single hydrophone spectrograms.

A source near the deep sound channel axis excites mode groups (or paths) that involve both deep sound channel and boundary interacting propagation. Dispersion from a broadband source as measured on a single hydrophone can be used to estimate source range. Furthermore, modal group speeds have a functional transition when passing through purely refractive to boundary reflecting phase speed regions which, under certain conditions, provides additional arrival structure to aid in source localization. This additional arrival structure is in the form of a focal region in a spectrogram. Indeed, different data sets from the Acoustic Thermometry of the Ocean Climate (ATOC) Program [ATOC Consortium, Science 281, 1327-1332 (1998)] show that localization can be accomplished using this focal region and/or the overall dispersion properties as originally suggested fifty years ago [M. Ewing and J. L. Worzel, Geo. Soc. Am., Memoir 27 (1948)].

Journal Article↗

Modal analysis of broadband acoustic receptions at 3515-km range in the North Pacific using short-time Fourier techniques.

In 1995-1996 the Acoustic Thermometry of Ocean Climate (ATOC) experiment provided an opportunity to study long-range broadband transmissions over a series of months using mode-resolving vertical arrays. A 75-Hz source off the California coast transmitted broadband pulses to receiving arrays in the North Pacific, located at ranges of 3515 and 5171 km. This paper develops a short-time Fourier transform (STFT) processor for estimating the signals propagating in the lowest modes of the ocean waveguide and applies it to analyze data from the ATOC experiment. The STFT provides a convenient framework for examining processing issues associated with broadband signals. In particular, this paper discusses the required frequency resolution for mode estimation, analyzes the broadband performance of two standard modal beamforming algorithms, and explores the time/frequency tradeoffs inherent in broadband mode processing. Short-time Fourier analysis of the ATOC receptions at 3515 km reveals a complicated arrival structure in modes 1-10. This structure is characterized by frequency-selective fading and a high degree of temporal variability. At this range the first ten modes have equal average powers, and the magnitude-squared coherence between the modes is effectively zero. The coherence times of the peaks in the STFT mode estimates are on the order of 5.5 min. An analysis of mean arrival times yields modal dispersion curves and indicates that there are statistically significant shifts in travel time over 5 months of ATOC transmissions.

Journal Article↗