Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Separation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Dissolved organic matter in pore water of freshwater sediments: effects of separation procedure on quantity, quality and functionality.

Pore water was separated either with or without water extraction prior to centrifugation (7600 or 20,000 x g) in order to investigate the effects of separation procedure on the amount and properties of dissolved organic matter (DOM i.e. the material passing through a 0.45-microm filter) in three freshwater sediments. On the basis of solubility in alkaline, organic matter was concluded to compose of humic substances in two (S1 and S3) and of humin (S2) in one of the sediments. DOM in the samples was quantified by total organic carbon measurement. Specific UV-absorption (SUVA) and high performance size exclusion chromatography (HPSEC) analyses were used to characterize DOM. Sorption of pyrene was used as a measure for functionality of DOM. Both water extraction and centrifugation speed were shown to affect the properties of DOM; however, the effects were sediment dependent. Water extraction increased the amount of DOM separated from the two sediments that had humic character (S1 and S3). In most cases water extraction increased SUVA and shifted the molecular size distribution of DOM towards larger sizes. The separation procedure had also an effect on the functionality of DOM. In water extracted samples of S2 and S3 the sorption of pyrene was higher than in the corresponding samples separated without water extraction, whereas in S1 similar effect was not found. Generally, centrifugation speed had smaller effects on the properties of DOM than water extraction. The fact that the effects of separation procedure on DOM depend on the sediment characteristics complicates the comparison between samples and evaluation of functionality in field conditions.

Adsorption↗

Separation of plastic mixtures using liquid-fluidized bed technology.

Separation of heavier-than-water plastic mixtures had been investigated via the fluidization of their packed beds induced by an upward flow of water. The samples examined were resin pellets and crushed plastic products including PVC, PET and PBT. On the onset of a flow, a mixed bed was swelled to the state of fluidization and separated into layers of respective resins depending on their density. The effects of the flow rate, an amount of the samples and their density difference were examined on the separation of resin pellets. Under an appropriate condition, the process was completed within a few minutes, and satisfactory separation was attained when the density difference of the samples exceeded 0.05 g cm-3. By using a column equipped with several sample outlets sorted resins could be recovered with their purity intact by withdrawing each layer successively from above through a suitable outlet. Multi-stage separation was also found to be effective in treating close-density samples. Compared with uniform-sized resin pellets, size distribution of crushed plastic samples deteriorated the separation to some extent.

Models, Theoretical↗

Advantages of the use of monolithic stationary phases for modelling the retention in sub/supercritical chromatography. Application to cis/trans-beta-carotene separation.

The low viscosity of supercritical fluids enables the coupling of columns, which favours both the high efficiency of separation and the ability of tuning the selectivity. However, it increases the inlet pressure then modifies the fluid density, i.e. the eluotropic strength of the mobile phase. In this case, the latter is rather different depending on the number of coupled columns. This fact prevents the calculation of the chromatographic parameters for coupled columns from the results obtained from one. In subcritical conditions, by using silica rod columns, which have bimodal porous structure, the flow resistance parameter is dramatically reduced. Consequently, the addition of monolithic columns induces only slight internal pressure changes and the fluid density does not vary with the column length. In this case, the calculation of retention factor and selectivity based on retention values obtained on each separate column provides accurate results allowing to determine the optimum column length in regard to the studied separation. After a better characterisation of the stationary phase included in the Chromolith column, this paper describes the beta-carotene isomers separation obtained by coupling up to six Chromolith columns to an octadecyl bonded particulate one. These compounds were studied because of the difficulty to separate these cis/trans isomers. No abnormal apparent dead volume change due to fluid density variation was reported, and good correlations between experimental and calculated retention factors and selectivities were observed. The optimum separation requires five highly porous columns coupled to a YMC Pack Pro. Moreover, the use of monolith packing allows to decrease both the retention factor and the analytical time by comparison to previous studies.

Chromatography, Supercritical Fluid↗

Use of reversed-phase high-performance liquid chromatography-diode array detection for complete separation of 2,4,6-trinitrotoluene metabolites and EPA Method 8330 explosives: influence of temperature and an ion-pair reagent.

Explosives such as 2,4,6-trinitrotoluene (TNT), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) are widely distributed environmental contaminants. Complete chromatographic separation is necessary in order to accurately determine and quantify explosives and their degradation products in environmental samples and in (bio)transformation studies. The present study describes a RP-HPLC method with diode array detection using a LC-8 guard column, a Supelcosil LC-8 chromatographic column, and a gradient elution system. This gradient method is capable of baseline separating the most commonly observed explosives and TNT transformation metabolites including 2,4,6-triaminotoluene (TAT) in a single run. The TNT metabolites separated were 2-hydroxylamino-4,6-dinitrotoluene, 4-hydroxylamino-2,6-dinitrotoluene, 2,4-dihydroxylamino-6-nitrotoluene, 4,4',6,6'-tetranitro-2,2'-azoxytoluene, 2,2',6,6'-tetranitro-4,4'-azoxytoluene, 4,4',6,6'-tetranitro-2,2'-azotoluene, 2,2',6,6'-tetranitro-4,4'-azotoluene, 2-amino-4,6-dinitrotoluene, 4-amino-2, 6-dinitrotoluene, 2,6-diamino-4-nitrotoluene, 2,4-diamino-6-nitrotoluene, and TAT. The same gradient method at a different column temperature can also be used to baseline separate the explosives targeted in the Environmental Protection Agency (EPA) Method 8330 with approximately 22% reduction in total run time and 48% decrease in solvent consumption compared to previously published methods. Good separation was also obtained when all TNT metabolites and EPA Method 8330 compounds (a total of 23 compounds) were analyzed together; only 2,6-DANT and HMX co-eluted in this case. The influence of temperature (35-55 degrees C) and the use of an ion-pair reagent on the chromatographic resolution and retention were investigated. Temperature was identified as the key parameter for optimal baseline separation. Increased temperature resulted in shorter retention times and better peak resolution especially for the aminoaromatics investigated. The use of an ion-pair reagent (octanesulfonic acid) generally resulted in longer retention times for compounds containing amine functional groups, more baseline noise, and decreased peak resolution.

Chromatography, High Pressure Liquid↗

Effects of the length and modification of the separation channel on microchip electrophoresis-mass spectrometry for analysis of bioactive compounds.

Analyses of amino acids and peptides were performed using a quartz microchip and an interface for microchip electrophoresis-electrospray ionization mass spectrometry (MCE-ESI-MS). In MCE-ESI-MS, negative pressure caused by ESI increased band broadening and deteriorated separation. We tried to suppress the negative pressure and improve separation using a microchip with a long separation channel. Separations of peptide standards were compared using two microchips with long separation channel (58.9 mm) and short one (22.9 mm). Theoretical plate numbers and resolution were improved significantly using the former. The theoretical plate numbers of [Val4]angiotensin was 8600 using the former and 1700 using the latter. When background electrolytes of low pH were used in an uncoated quartz microchip, electrokinetic injection was difficult because of weak electroosmotic flow. The use of successive multiple ionic polymer layers coating of the microchip channel stabilized electrokinetic injection and permitted analysis of amino acids and peptides even under low pH conditions. Separation of amino acids was successfully performed using formic acid solution (pH 2.5) as background electrolyte.

Electrophoresis↗

Analysis of synthetic peptides by capillary electrophoresis: effect of organic solvent modifiers and variable electrical potentials on separation efficiencies.

In this study, procedures based on volatile ammonium acetate buffer electrolytes of high pH value containing different organic solvent modifiers have been developed to achieve very high efficiency separations of histidine-containing synthetic peptides by high-performance capillary electrophoresis (HPCE) employing untreated fused silica capillaries. Different organic solvents, including acetonitrile, methanol and ethanol, at high volume fractions were used to modify the composition of the background buffer electrolyte. With the peptides investigated, it was found that methanol had the greatest effect in terms of enhancement of separation efficiency, as determined from the evaluation of theoretical plate numbers, N, of these HPCE systems. On the other hand, separation selectivities, e.g. the alpha(ij) values, did not change significantly as the volume fraction, psi, of the organic solvents was increased up to psi = 60% (v/v). Under these conditions, very rapid, e.g. 1-2 min, separation times could be still achieved. Compared to the effect of carrying out the separation of these peptides at constant voltage, a dramatic increase in the separation efficiency was also achieved by applying a linear voltage gradient during the HPCE experiment. Under optimal conditions of organic solvent composition and linear voltage gradient ramps, very high peak efficiencies for the studied set of synthetic peptides with N values of approximately 2-3 million theoretical plates per meter could be routinely obtained with fast analysis times. Moreover, these buffer electrolyte conditions are compatible with direct interfacing of the HPCE effluent to electrospray ionisation and ion trap mass spectrometers, thus expanding the analytical capabilities of these HPCE systems.

Electrophoresis, Capillary↗

High-speed gas chromatography with direct resistively-heated column (ultra fast module-GC)-separation measure (S) and other chromatographic parameters under different analysis conditions for samples of different complexities and volatilities.

The influence of GC speed on the separation capability of a chromatographic system is reported measuring a series of parameters including separation measure (S), peak capacity (n), peak width (w), analysis time, t(b) (determined on the last eluting compound) and separation measure/analysis time ratio (S/t(b)) determined by analyzing a bergamot essential oil sample and a standard mixture of pesticides. Conventional GC, fast GC (with 10 m (FGC10) and 5 m (FGC5) narrow-bore columns), and direct resistively-heated ultra fast module-GC (UFM-GC) were the GC speed approaches used. The influence of different heating rates with a constant flow for FGC5, FGC 10, and UFM-GC and with variable flows for UFM-GC on S, n, w, S/t(b), and t(b) was also studied. The results of this study show that: (a) separation capability of the chromatographic system (i.e. S and n) and analysis time depend on the GC approaches. Within each GC approach, S and n and analysis time depend on the heating rates, although to a different extent, and S and n decrease much less than the gain in analysis time, in particular when fast heating rates are applied; (b) in UFM-GC, the loss of separation capability with heating rate can also be partially compensated by the choice of an appropriate flow rate that, within each heating rate, may contribute to increase S while reducing t(b); (c) within a specific GC approach, the chromatographic system (column and stationary phase) and conditions (heating and flow rates) must be such to achieve a suitable S-value when two analytes must be separated with a given resolution in a minimum analysis time.

Chromatography, Gas↗

On the capillary gas chromatographic separation of enantiomers of N-trifluoroacetyl-O-alkyl esters of selected amino acids on 2,3-di-O-pentyl-6-O-acyl cyclodextrins.

In this work, the separation of enantiomers of N-TFA-O-alkyl amino acids on the 2,3-di-O-pentyl-6-O-acyl alpha-, beta- and gamma-cyclodextrin stationary phases has been studied. The influence of structure differences in the alkyl substituents bonded to the stereogenic carbon atom (R1), as well as in the ester group (R2) of the selected amino acid derivatives, and the selectivity of modified alpha-, beta- and gamma-cyclodextrin phases in gas chromatographic separation of derivatized amino acid enantiomers was studied in detail. A model set of N-TFA-alkyl esters of four amino acids was separated on five columns. The separation of enantiomers was evaluated in terms of the interactions of the alkyl substituents bonded to the stereogenic carbon (R1) and/or the ester group (R2) of the N-TFA-O-alkyl amino acid derivatives as well as the nature of the 3-O-acyl group in the 2,6-di-O-pentyl-3-O-acyl alpha-, beta- and gamma-cyclodextrins. It was shown that the variation in the enantiomeric separation with temperature and the retention order of enantiomers on a given cyclodextrin capillary column depends both on the nature of the bonded R1 and R2 alkyl groups. It was found that the temperature dependencies of selectivity factors, ln alpha on 1/T, were mostly non-linear. The thermodynamic data [delta(deltaS) and [delta(deltaH)] which characterize the chiral recognition were used to gain more insight into the mechanistic aspects of enantio separation of the N-TFA-O-alkyl amino acid derivatives on 2,6-di-O-pentyl-3-O-acyl-alpha-, beta- and gamma-cyclodextrins.

Amino Acids↗

Screening approach for chiral separation of pharmaceuticals. Part III. Supercritical fluid chromatography for analysis and purification in drug discovery.

High-throughput and performance analysis and purification of enantiomers are important parts of drug discovery and provide high-quality compounds for pharmacological testing. We have previously reported two parts describing chiral chromatographic screens using normal-phase (NPLC) and reversed-phase (RPLC) liquid chromatography, in order to cope with increasing numbers of new compounds generated by chemistry programs. We present in this part the development and implementation of a third faster screen using supercritical fluid chromatography (SFC) to maximize chance in achieving rapid enantiomer resolution of large numbers of compounds in a minimum of time. The SFC screen utilizes a narrow combination of only four columns (Chirlapak AD and AS, and Chiralcel OD and OJ) and two solvent modifiers (methanol and isopropanol). A modifier and column-switching setup was employed to allow the entire screening process to be serially run in the order AD> OD > OJ > AS and methanol > isopropanol, so that the screening for a given molecule can be stopped when separation is achieved. The switching system was fully automated for unattended operation of multiple compounds. An optimization procedure was also defined, which can be performed if needed for unsuccessful separations in the screening step. The chiral SFC strategy proved its performance and robustness in resolution of hundreds proprietary chiral molecules generated by drug discovery programs, with a success rate exceeding 95%. In addition, the generic capability of the strategy was evaluated by applying the screen and optimization methodology to a test set comprising 40 marketed drugs differing from proprietary compounds in terms of chemical diversity, revealing a similar high success rate of 98%. Chiral separations developed at the analytical scale work easily and equally well at the semi-preparative level, as illustrated with an example. The SFC screen allows resolution of compounds that were partially separated by NPLC or not separated at all by RPLC, demonstrating the utility of implementing complementary chromatographic techniques. The SFC screen is currently an integral part of our analytical support to discovery chemical programs and is considered the first try for chiral separations of new compounds, because it offers a higher success rate, performance and throughput.

Chromatography, Supercritical Fluid↗

Chiral separation of amines in subcritical fluid chromatography using polysaccharide stationary phases and acidic additives.

The chiral separation of basic compounds by subcritical fluid chromatography (SFC) is often unsuccessful, due possibly to multiple interactions of the analyte with the mobile and stationary phase. Incorporation of a strong acid, ethanesulfonic acid (ESA), into the sample diluent and mobile phase modifier gives a dramatic improvement in these separations. Screening with ethanol containing 0.1% ESA on CHIRALPAK AD-H gave separation of 36 of 45 basic compounds previously not separated in SFC. The mechanism appears to involve the separation of an intact salt pair formed between the basic compound and ESA. Other modifiers, other acids and one additional stationary phase were examined and found to yield additional separations.

Alkanesulfonates↗

Alternative high-performance liquid chromatographic peptide separation and purification concept using a new mixed-mode reversed-phase/weak anion-exchange type stationary phase.

This article describes a new complementary peptide separation and purification concept that makes use of a novel mixed-mode reversed-phase/weak anion-exchange (RP/WAX) type stationary phase. The RP/WAX is based on N-(10-undecenoyl)-3-aminoquinuclidine selector, which is covalently immobilized on thiol-modified silica particles (5 microm, 100 A pore diameter) by radical addition reaction. Remaining thiol groups are capped by radical addition with 1-hexene. This newly developed separation material contains two distinct binding domains in a single chromatographic interactive ligand: a lipophilic alkyl chain for hydrophobic interactions with lipophilic moieties of the solute, such as in the reversed-phase chromatography, and a cationic site for anion-exchange chromatography with oppositely charged solutes, which also enables repulsive ionic interactions with positively charged functional groups, leading to ion-exclusion phenomena. The beneficial effect that may result from the combination of the two chromatographic modes is exemplified by the application of this new separation material for the chromatographic separation of the N- and C-terminally protected tetrapeptide N-acetyl-Ile-Glu-Gly-Arg-p-nitroanilide from its side products. Mobile phase variables have been thoroughly investigated to optimize the separation and to get a deeper insight into the retention and separation mechanism, which turned out to be more complex than any of the individual chromatography modes alone. A significant anion-exchange retention contribution at optimal pH of 4.5 was found only for acetate but not for formate as counter-ion. In loadability studies using acetate, peptide masses up to 200 mg could be injected onto an analytical 250 mm x 4 mm i.d. RP/WAX column (5 microm) still without touching bands of major impurity and target peptide peaks. The corresponding loadability tests with formate allowed the injection of only 25% of this amount. The analysis of the purified peptide by capillary high-performance liquid chromatography (HPLC)-UV and HPLC-ESI-MS employing RP-18 columns revealed that the known major impurities have all been removed by a single chromatographic step employing the RP/WAX stationary phase. The better selectivity and enhanced sample loading capacity in comparison to RP-HPLC resulted in an improved productivity of the new purification protocol. For example, the yield of pure peptide per chromatographic run on RP/WAX phase was by a factor of about 15 higher compared to the standard gradient elution RP-purification protocol.

Anion Exchange Resins↗

Interpreting the effects of temperature and solvent composition on separation of amino-acid racemates by chiral ligand-exchange chromatography.

Routinely applied at both preparative and analytical scales, chiral ligand-exchange chromatography (CLEC) separates enantiomers capable of chelating a divalent transition-metal-ion through a pair of coordinating electronegative atoms. CLEC separation efficiencies are strongly dependent on column operating conditions, including temperature and mobile-phase solvent composition. Although previous empirical studies provide some useful guidelines for optimizing column operating conditions, the fundamental mechanisms underlying the unusually high sensitivity of CLEC performance to operating temperature and solvent composition remain poorly understood, limiting efforts to develop a comprehensive model for the technology. To address this problem, we report transport and chemical equilibria data for the separation of alpha-amino acids on a Nucleosil chiral-1 column presenting L-hydroxyproline as the immobilized ligand. Solute transport is found to be limited by pore diffusion at all column operating temperatures and solvent compositions, validating the existence of local equilibria throughout the column. Changes in separation performance are found to correlate with changes in chemical equilibria, emphasizing the need to carefully account for all speciation within the column when modeling CLEC and providing important fundamental data to achieve this goal. Each enantiomer participates in a large number of solution-phase complexes. As a result, the thermodynamic driving force for separation is unusually complex, allowing subtle changes in column operating conditions to mediate significant changes in speciation profiles and separation efficiency. A reaction-equilibria model accounting for all speciation within the CLEC column is proposed and used to estimate enantiomer partition coefficients and retention times.

Amino Acids↗

Separation of isomeric 2-aminopyridine derivatized N-glycans and N-glycopeptides of human serum immunoglobulin G by using a zwitterionic type of hydrophilic-interaction chromatography.

Isomeric oligosaccharides and isomeric glycopeptides are sometimes difficult to separate on normal-phase (NP) and reversed-phase (RP) columns. A zwitterionic type of hydrophilic-interaction chromatography column with sulfobetaine groups (called ZIC-HILIC column) was first applied to the separation of 2-aminopyridine derivatized (PA) N-glycans and tryptic peptides of human serum immunoglobulin G (IgG). It is shown that the ZIC-HILIC column has high capability for structural recognition of isomeric N-glycans as well as high selectivity for glycopeptides. The former feature (i.e., structural recognition) was proven by sufficient separation of neutral PA N-glycan isomers, which are usually difficult to separate on NP and RP columns. In addition, it is noteworthy that IgG glycopeptides consisting of isomeric N-glycans and the same peptide sequences can be sufficiently separated on a ZIC-HILIC column. The latter feature (i.e., selectivity) was also demonstrated by easily separating two peptide groups with/without N-glycans. Thus, we note that the ZIC-HILIC column is highly promising for a simple analysis of N-glycans and N-glycopeptide samples.

Aminopyridines↗

Continuous separation of particles using a microfluidic device equipped with flow rate control valves.

We propose herein an improved microfluidic system for continuous and precise particle separation. We have previously proposed a method for particle separation called "pinched flow fractionation." Using the previously reported method, particles can be continuously separated according to differences in their diameters, simply by introducing liquid flows with and without particles into a specific microchannel structure. In this study, we incorporated PDMS membrane microvalves for flow rate control into the microfluidic device to improve the separation accuracy. By adjusting the flow rates distributed to each outlet, target particles could be precisely collected from the desired outlet. We succeeded in separating micron and submicron-size polymer particles. This method can be used widely for continuous and precise separation of various kinds of particles, and can function as an important part of microfluidic systems.

Microfluidic Analytical Techniques↗

Multi-step dielectrophoresis for separation of particles.

A new concept for separation of particles based on repetitive dielectrophoretic trapping and release in a flow system is proposed. Calculations using the finite element method have been performed to envision the particle behavior and the separation effectiveness of the proposed method. As a model system, polystyrene beads in deionized water and a micro-flow channel with arrays of interdigited electrodes have been used. Results show that the resolution increases as a direct function of the number of trap-and-release steps, and that a difference in size will have a larger influence on the separation than a difference in other dielectrophoretic properties. About 200 trap-and-release steps would be required to separate particles with a size difference of 0.2%. The enhanced separation power of dielectrophoresis with multiple steps could be of great importance, not only for fractionation of particles with small differences in size, but also for measuring changes in surface conductivity, or for separations based on combinations of difference in size and dielectric properties.

Electrodes↗

Influence of pore size on the separation of random and block copolymers by interactive liquid chromatography.

Stationary phase materials with small pore diameters are often used for the separation of copolymers according to their chemical composition. The rationale for such a column selection is to minimize the influence of the molecular weight on the separation. In this paper, we describe a detailed study of the influence of the pore size on the retention and separation of poly(methylmethacrylate) (PMMA)-poly(butylmethacrylate) copolymers. We used normal-phase (NP) and reversed-phase (RP) columns with various pore diameters, as well as non-porous columns and a monolithic column. The pore size was found to affect the separation, especially for (co-)polymer molecules with characteristic diameters that roughly correspond to the exclusion limit of the column. Also possibilities to separate block copolymers according to block length are strictly investigated. The making of one block in a di-block (DB) copolymer "invisible" can only be fulfilled if the "invisible" block does not play any role in the separation.

Calibration↗

Increasing the scale of true moving bed electrophoretic separations using filtration to reduce solvent volumetric flows between sections II and III.

Over the past decade the moving bed process has become a commonly used tool for the continuous separation of chiral compounds, and its recent application to electrophoretic separations allows the technique to be used as a model system for moving bed method improvements. Much of the recent research on moving bed separations has focused on improving the technique's efficiency and increasing the maximum attainable throughput. This paper presents a novel method for reducing or reversing the increases in tailing that stem from the addition of the feed stream in a moving bed process by adding a filtration unit which retains the products while removing fluid from the boundary between the sections above and below the feed stream. This filtration-enhanced moving bed process was applied to a true moving bed (TMB) electrophoresis separation in the Vortex Stabilized Electrophoresis Apparatus, and its effect on a homatropine enantiomer separation was studied. Experiments showed that there is a 2.4-fold increase in the homatropine processing rate when 0.5 ml/h of water is removed through a reverse osmosis filter at the boundary between the sections above and below the feed stream. In order to further understand the process, filtration-enhanced TMB (FE-TMB) was also analyzed using a linear model of the system which shows that the 99% purity operating region of the separation is greatly increased even with moderate permeate flowrates.

Adsorption↗

Separation of craniopagus conjoined twins: an evolution in thought.

Advances in medicine have enabled more craniopagus twins to survive separation, but the ultimate goal, to have both twins emerge from their separation with full neurologic function and a chance at leading independent and productive lives, remains elusive. The authors were contacted to evaluate craniopagus conjoined male infant twins for separation. Once it was determined that the brains were separate, they reviewed the literature and elected to design an open-ended multistaged separation. Four major stages over 9 and a half months led to the successful separation and preservation of neurologic function. To the authors' knowledge, this is the first such outcome in such a case. This article reviews the pertinent literature and discusses the authors' rationale and methodology.

Head↗